USER`S MANUAL

image

Contents

1. AC BATTERY OUTPUTS INTERNET NEMA5 15R 6 321 IS FT a E il REMOTE AC BATTERY OUTPUTS Y ats IN OUT gt Ob INTERNET AC INPUT 3 owo REMOTE AC BATTERY OUTPUTS O INTERNET AC INPUT INSTALLATION AND OPERATION Upon receipt of the UPS inspect the shipping carton for damage If there is any obvious damage immediately report it to the selling dealer or the delivering carrier If there is no damage to the shipping carton unpack the unit and inspect the unit for damage The UPS is designed for installation in a protected environment within a temperature range from 32 F to 104 F and relative humidity of 0 90 without condensation Do not block inlets and outlets Install the system in a location free from excessive dust and chemical fumes Check the identification label to verify the UPS voltage and power rating match the available line voltage and load requirements Installation 1 Check
2. EN ED RN a Emergency Backup Power Supply For Use With Computer Loads Only 5 Power Surge Noise Protection Intelligent Auto Shutdown Software ey 7 Internet Line Protection gt gt Compact 8 Reliable Design gt lt D y Q oO 2 o 5 7 SD USER S MANUAL Uninterruptible Power System IMPORTANT SAFETY INSTRUCTIONS Thank you for selecting this uninterruptible power system UPS It provides you with better protection for connected equipment Please read this manual This manual provides safety installation and operating instructions than will help you derive the fullest performance and service life that the UPS has to offer Please save this manual It includes important instructions for the safe use of this UPS and for obtaining factory service should the proper operation of the UPS come into question Please save or recycle the packaging materials The UPS s shipping materials were designing with great care to provide protection from transportation related damage There materials are invaluable if you ever have to return the UPS for service Damage sustained during transit is not covered under the warranty NOTES 42 CAUTION The UPS contains voltage that are potentially hazardous All repairs should be performed by qualified service personal The UPS has its own internal energy source battery The output receptacles may be alive even when the UPS is not connected to an
3. if the main switch on the UPS front panel is in the off position and insure that the voltage of the AC utility source corresponds to the nameplate on the UPS rear panel 2 Connect the power cord to a verified grounded 3 wire receptacle 3 Turn on the power switch of UPS the green LED will be lit indicating AC utility voltage is present 4 Charge the batteries for ten 10 hours before use You may use the UPS immediately without recharging but the backup time maybe less than the rating 5 Connect your computer to the output receptacles of the UPS 6 To test backup function you may disconnect the power cord of the UPS from wall outlet The Yellow LED will light on and alarm will beep every 3 seconds 7 When battery approaches low level alarm will beep every second until auto shut down 8 The 4 conditions UPS will automatically shut down a Battery low b Short circuit c Overload d UPS fault
4. AC supply The UPS is suitable for computers and electronic equipment with substantially rectifier or capacitive loads not suitable for electronic equipment with significant inductive loads such as motors amp fluorescent lamps Be sure to operate within the power rating of the UPS Below 1 2 or 1 3 of rated power is recommended for longer backup time amp longer battery life Do not place the UPS near excessive humidity under sunshine or close to heat emitting sources If the UPS is out of order please detach power cord and consult your dealer right away Do not remove cover if there is no serviceable part inside The unit should be supplied by grounded source Do not operate the unit without ground source The socket outlet should be installed near the equipment and be easily accessible Do not plug the UPS power cord into itself That will result in a safety hazard Installation should be performed by a qualified technician or electrician in accordance with local electrical codes SPECIFICATIONS Capacity VA 800VA 1000VA 100VAC 110VAC 120VAC 220VAC 230VAC or 240VAC Voltage Input 425 Frequency 50Hz or 60Hz 5 100VAC 110VAC 120VAC 220VAC 230VAC or 240VAC Voltage Batt Mode 10 Output Frequency 50Hz or 60Hz 1Hz Waveform Modified sine wave Transfer Time Less than 4ms typical Sealed maintenance free lead acid batteries with 3 5 Battery Type Batter
5. BLE SHOOTING If the UPS failed to operate properly please review the following checks firstly If the problem remain please consult sales agent for service Is the Master power switched on Is the UPS plugged into a correctly working outlet Is the line voltage within the rating specified Is the fuse on the rear panel blown Is the UPS over loaded Is battery not fully charged Dead battery Charger failure Please provide the following information when call for service 1 Model number serial number 2 Date of the problem occurred date of purchase 3 Full description of the problem including load LED and alarm status installation condition working environment etc Trouble Shooting Chart Problem Possible Cause Caution To Take Front panel switch Turn on switch in off position No light and no alarm Rear panel fuse UPS not on Replace fuse restart UPS burnout Power cord lose Check input power No Green LED Power cord lose Check input power light and alarm beeps Replace fuse if problem AC Fuse burnout every 3 seconds remains call for service Recharge the battery for at Backup time is less Battery is not fully least 6 hours re test the than the rating charger failure backup time If problem remains call for service 11 3 AC Utility Failure If AC utility fails the UPS quickly detects the problem and activates the inverter Th
6. e inverter The DC AC inverter changes DC power from the batteries into AC and provides continuous uninterruptible power to load Fig 3 shows how the UPS works when AC Utility Failure BATTERY FACTS The battery is the only periodically serviceable parts in the UPS An expected life is approx 3 5 years However frequent long discharges or ambient temperatures above 80 F will shorten battery life Therefore it is recommended to replace the batteries every 3 years after initiating the unit Recharge batteries every 3 months is necessary if it is not in use because it may cause batteries over drain WARNING Only a qualified technician should replace the battery Batteries have high short circuit current capacity mistakes in connecting or disconnecting can cause connections to arc or weld and could cause severe burns STORAGE The UPS should only be stored if the battery is fully charged Avoid storage temperatures above 80 F as battery life is significantly shortened Every 90 days remove the unit from storage and plug it in for 24 hours to recharge the batteries Batteries may be damaged if left in storage and not recharge every 90 days IMPORTANT NOTICE Please use same type and same rating of batteries for replacement Do not replace it with the battery that exceeds specified rating AC BATTERY OUTPUTS 321 TO mt 3 P REMOTE IN OUT OC INTERNET
7. ogaaisa untada 5 REAL PANEL 2 aa a oi a 5 PICTURE sere sats ies ra E A e EE COENE 5 5 INSTALLATION AND OPERATION ceeeeeeeeeeeeee eee ee ees 7 6 COMPUTER INTERFAGE sei ae 8 Ys BATTERY FACTS A ls 9 8 SPECIFICATIONS vi coo 10 9 TROUBLE SHOOTINGE sn ea era 11 10 NOTES 2 12 INTRODUCTION System Description The product is line interactive UPS with the newest technology and powerful function The Line Interactive UPS is with AVR function allows input voltage range from 75 to 125 including on line voltage boost up amp buck down An ideal protection equipment for critical connected loads In addition This UPS provides advanced single telephone line or modem surge suppression through the modular connectors on the back panel The Line Interactive UPS and RUPS2000 monitoring software Optional kits makes our computer operate intelligent and provides you with the ability of perfect protection of your critical devices Features gt Line interactive design gt Easy LED display gt Provide boost and buck AVR to stabilize input voltage gt Provides lightning surge overload and short circuit protection gt Built in CCCV battery charger and battery over drain protection gt Auto restart when AC recovery gt Cold start function Dip power on gt Tel Modem Fax Internet surge suppression gt Option Bundle software Automatically save your valuable files before auto shutdown TROU
8. the computer to monitor the status of the UPS and control the operation of the UPS Pin out information PIN Description 1 0 PIN1 Battery low normally open active close Output PIN2 N C PIN3 Common Ground PIN4 Remote shut down keep this pin high Input 5 12V for 3S will turn off the UPS PIN5 N C PIN6 N C PIN7 Must keep in high state Input PIN8 Line fail normally open active close Output PIN9 N C D SUB 9 Pin Female Connector Contacts Normally o 1 Low Battery 8 Mains Failure UPS Shut Down Pin Number OVERVIEW Front Panel 1 Master Power Switch Turn on off the UPS 2 Green LED AC Normal 3 Vellow LED Battery in back up 4 Red LED UPS Cut off ear Panel Input IEC type connector to connect the power cable AC Fuse Protection against short circuits electronic fuse Data line protection Filtering of electrical noise on data transmission lines Communication port Basic communications AC Battery outputs Output protected for critical loads that require additional electrical power 6 UPS function setup No load auto shut down Dc start On and Buzzer Alarm auto reset 7 USB PORT OPTION Picture ae aoa y Aa CONTENTS PAGE Te CAUTION aa ae A ISA 1 2 INTRODUCTION SYSTEM BESCHIPTION a2 2 ee 2 FEATURES ana re 2 3 SYSTEM CONCEPT BLOCK DIAGRAM aaa be 3 NORMAL OPE RATION sea ass 3 AC UTILITY FALUR E Sacris 4 4 OVERVIEW FRONT PANEL cudri
9. y years typical lifetime Recharge Time 5 hours to 90 of full capacity Indicator LED LED indicator for line on battery back up UPS cut off Battery Back up Sounding every 3 seconds Alarm Battery Low Sounding every 1 second Overload Continue beeping sound Overload Fuse amp current limited Protection Short Circuit Fuse amp current limited amp cut off Batt Low Cut off No battery drain after cut off Physical Dimension D W H 385 94 170 mm Environment Operating Temperature 32 F 104 F at full load 0 90 relative humidity non condensing Noise Level Less than 40db at 1 meter Interface Contact Closure DB9 connector for connecting with Rups 2000 software Software Rups 2000 Option 10 SYSTEM CONCEPT The purpose to present this chapter is to give you more precise conception about how UPS works 1 Block Diagram OUTPUT Fig 1 shows how UPS works 2 Normal Operation There are two main loops when AC Utility normal the AC output loop and the battery charging loop The AC output gets power from AC utility input and pass through AVR to support power to load In the same time the AC utility input is converted by AC DC CHA and support charging power to charge batteries OUTPUT Fig 2 shows how the UPS works when AC Utility normal de COMPUTER INTERFACE The computer interface DB9 port on the back of the UPS may be connected to a host computer This port allows

Download Pdf Manuals

image

Related Search

Related Contents

User manual Upright bikeProDyaco-20140509-new display  102189801 0800B00000  Télécharger le dossier d`inscription  StarTech.com 6 ft Gray Flat Molded RJ45 UTP Cat 5e Patch Cable - 6ft Patch Cord  Samsung AQ09ESAX User Manual      Instrucciones  95-113364 US EN R2 STATIM 2000 G4 5000 G4 OpMan 20140904  User Manual_SNB-1000,SND-1010  