1. panel 7 TEMP WATE I HUMI P SPEED i i pra ale TIMER 1 Humidity selection button 8 Low speed indicator 2 Speed ventilation button 9 Timer 3 Display window 10 Water full indicator 4 Temperature display button 11 ON OFF indicator 5 ON OFF button 6 Humidity indicator 7 High speed indicator Operation 1 Plug the unit into a correct mains socket Please refer to the rating label at the rear of the unit 2 Press button ON OFF to turn on the unit The compressor will start to work in continuous Mode lonizer optional will start running automatically 3 Press button HUMI to set the room humidity you need continuous de humidifying 40 50 60 or 70 When the room humidity is under 35 the display will show LO and if the room humidity is over 95 it will snow HI 4 Press the Speed button to choose the ventilation speed high or low 5 Press the temperature button to display the room temperature It will revert to display the room humidity after 12 seconds 6 Press the timer button to set up the time for turn on turn off 1 24hr The unit will be continuous de humidifying without timer setting 7 To turn off the unit press button ON OFF again While the water tank is full fhe compressor will stop for self protection and water full indicator will turn into red wa AA The water full indicator will turn into red The unit will buzz For stopping the buzz you may press
2. FF switch is turned on e Check the water tank is positioned properly in the unit and it is not full Make sure the air inlet and outlet are not obstructed THE UNIT SEEMS TO DO NOTHING e isthe filter dusty contaminated Is the air intake or outlet blocked up e Is the room humidity already quite low THE UNIT SEEMS TO DO LITTLE Are too many windows or doors open Is there something in the room producing lots of humidity THE UNIT IS TOO NOISY Check whether the unit is sitting on a level surface THE UNIT IS LEAKING Make sure the unit is in good shape If you are not using continuous drainage make sure the rubber plug at the bottom of the unit is in its position Technical specification T Netto weight 18 5 kg NOTE CONCERNING PROTECTION OF ENVIRONMENT This product must not be disposed of via normal household waste after its service life but Must be taken to a collection station for the recycling of electrical and electronic devices The symbol on the product the operating instructions or the packaging indicate such disposal procedures The materials are recyclable in accordance with their respective symbols By means of re use Material recycling or any other form of recycling old appliances you are making an important contribution to the protection of our environment Please ask your local council where your nearest disposal station is located INFORMATION CONCERNING USED REFRIGERANT MEDIUM This un
3. OPERATION MANUAL SINCLAIR AIR CONDITIONING Before use Caution Always keep the unit in vertical position Leave the unit to stand for one hour before connecting to the mains supply after transport or when it has been tilted e g during cleaning Keep all foreign objects away from the air intake or output openings The mains supply must conform to the specification shown on the rating plate at the back of the unit If the supply cord is damaged it must be replaced by an approved service representative or a similar qualified person in order to avoid a hazard Never use the plug to start and stop the unit Always use switch on the control panel Before moving the unit first switch off then unplug and empty the water tank Don t use bug sprays or other flammable cleaners on the unit Never pour or spray water over the unit THIS APPLIANCE IS NOT INTENDED FOR USE BY PERSONS INCLUDING CHILDREN WITH REDUCED PHYSICAL SENSORY OR MENTAL CAPABILITIES OR LACK OF EXPERIENCE AND KNOWLEDGE UNLESS THEY HAVE BEEN GIVEN SUPERVISION OR INSTRUCTION CONCERNING USE OF THE APPLIANCE BY A PERSON RESPONSIBLE FOR THEIR SAFETY CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH APPLIANCE IMPORTANT Do not use this unit at ambient temperatures below 5 C to prevent the possibility of a heavily ice up evaporating coll Please take time to read this manual carefully before use and save it for future reference Where to po
4. it is containing fluorinated gases included in the Kyoto protocol The maintanance and the liquidation must be carried out by qualified personel Type of refrigerant R410A The composition of the cooling Medium R410A 50 HFC 32 50 HFC 1 25 The quantity of the refrigerant please see the unit label Hermetically sealed system The value GWP 2088 GWP Global Warming Potential In case of quality problem or other please contact your local supplier or authorized service center Emergency number 112 PRODUCER Producer SINCLAIR CORPORATION Ltd 1 4 Argyll St London W1F 7LD UK www sinclair eu com This product was manufactured in China Made in China REPRESENTATIVE AND TECHNICAL SUPPORT NEPA spol s r o Purkynova 45 612 00 Brno Czech Republic Tel 420 800 100 285 WWW NepbA CZ a CE
5. on t ever use volatile chemicals gasoline detergents chemically treated clothes or other cleansing solutions These all could possibly hurt the cabinet CLEANING THE AIR FILTER Remove the filter from the unit back FIG 4 FIG 4 For washable filter Use a vacuum cleaner or tap the filter lightly for easy cleaning If the filter is particularly dirty use warm water with a small amount of Medium strength FIG 5 ee x 2 x a a Pa Su N e FIG 5 N 1 ba Make sure the filter is completely dry before replacing Do not expose the filter to sunlight For active carbon filter This filter is not washable Its life soan is variable and depends on the ambient conditions where the appliance is used The filter should be checked periodically about every 6 months and replaced if necessary filter fixer washable filter active carbon filter STORAGE If not use the unit for an extended period of time Please Turing the unit off unplug and tidy AC cord Completely empty the water tank and wipe it clean Put the AC cord into the empty water tank FIG 7 and then put pack the water tank into the unit Cover the unit and store where it will not receive direct sunlight 7 Trouble shooting THE UNIT DOES NOT OPERATE Is the unit plugged in e Is the house electricity on e Is the room temperature below 5 C or above 35 C If so then it is out of the working range of the unit Ensure the ON O
6. sition Excess moisture will travel throughout your home in the same way that cooking smells waft to every room in the house For this reason the dehumidifier should be positioned so that if can draw this moist air towards it from all over the home Alternatively if you have a serious problem in one area you can begin by positioning the dehumidifier close to this area and later moving it to a more central point water tank emptied When positioning the dehumidifier We do not recommend the use of an ensure that if is placed on a level extension lead so please try to ensure surface and that there is a minimum of that the unit is sufficiently close to a 10 cm 4 of space on either side of fixed mains socket If it is necessary to the unit to allow for efficient airflow use am extension lead please ensure This dehumidifier is fitted with castors for the diameter of the wires of the cable extra Mobility if you move the unit it is at least 1 mm should first be switched off and the When the dehumidifier is in operation outside doors and windows should be closed when necessary for most efficient use Front 1 Control panel 2 Air outlet 3 Front plate 4 Air inlet filter 5 Handle 6 Rear plate 7 Drain hole for continuous drainage 8 9 Water tank Caster 0 Power cable Assembly of the filters washable filter active carbon filter Control
7. the ON OFF button to turn off the unit To move the water tank pull it out squarely from the unit by using the handle at the water tank FIG 1 After empting the water tank place the water tank into space Make sure it is properly positioned in order for the water full sign to go out and your dehumidifier is operating FIG 2 Please note in case the water tank has not been positioned well the water full indicator will turn into red FIG 2 As the water tank is full or has not been positioned well the water level window will turn into red To move the water tank pull it out squarely from the unit by using the handle at the water tank Continuous drainage When the dehumidifier is operated at very high humidity levels the water tank will require more frequent drainage In this situation it may be more convenient to set the unit up for continuous drainage with the following procedures 1 Connect the drain hole with a water tube of inner diameter 12mm FIG 3 Please note the water tube is not supplied with the Unit 2 Ensure the water will always drain away freely and the tube will remain in right place Note In very cold weather conditions precautions should be taken to prevent the water tube from freeing FIG 3 Maintenance Always unplug the unit from the mains before carrying out any maintenance or cleaning of the unit CLEANING THE BODY Use soft cloth to wipe the unit clean D