1. Enable SSL for web communication nueutronics User must input the correct ID and password to enable SSL function The ID and password must be the same as the Total load 0 0 A Status Normal User Setting Information PDU Enable SSL Confirmation System Configuration ID Threshold Password User Network END OF DOCUMENT
2. MIB Management Information Base for Network http www a neutronics com Software ANI 15115 08xxx MIB zip PDU Software PDU Utility zip file http Awww a neutronics com Software ANI 15115 08xxx PDU Utility zip Or visit our website A Neutronics com to download directly from the product page SAFETY PRECAUTIONS Please read all instructions before attempting to unpack install or operate this equipment and before connecting the power supply Please keep the following in mind as you unpack and install this equipment Always follow basic safety precautions to reduce the risk of fire electrical shock and injury to persons To prevent fire or shock hazard do not expose the unit to rain moisture or install this product near water Never spill liquid of any kind on or into this product Never push an object of any kind into this product through any openings or empty slots in the unit as you may damage parts inside the unit Do not attach the power supply cabling to building surfaces Use only the supplied power supply unit PSU Do not use the PSU if itis damaged Do not allow anything to rest on the power cabling or allow any weight to be placed upon it or any person walk on it To protect the unit from overheating do not block any vents or openings in the unit housing that provide ventilation and allow for sufficient space for air to circulate around the unit DISCLAIMERS The information in this
3. PDU System Configuration Threshold User PDU 0 0 A Normal Threshold Warning Overload Network ail NMP SL INFORMATION SYSTEM Indicates PDU system information including Model No Q A Neutronics Firmware Version Total load 0 0 A Status Normal MAC Address Information Model No ANI 15115 08MTH Firmware Version s4 82 091012 1cb System Contact System MAC Address 00 16 18 77 0 04 PDU Location Configuration System Name PDU Threshold System Contact pem User Locati Network a Office Apply WEB INTERFACE CONFIGURATION THRESHOLD Set the warning and overload threshold for each circuit Q A Neutronics Set lower and upper threshold for temperature and humidity EXE GEN ISIN Information Threshold Amp Name PDU Warning Overload Configuration pl Threshold User Network CONFIGURATION USER Change ID and password Q Default is Total load 0 0 A Status Normal User Name snmp io Information Original Password 1234 PDU ID sd System Configuration Password Threshold New User ID Network ail Password WEB INTERFACE CONFIGURATION NETWORK PDU network information Enable DHCP Change the way to get IP address for PDU CONFIGURATION MAIL When event occurs PDU can send out an email message to pre defined account Email Server The Email Server only supports the domain name not IP address e
4. Sender s Email Input the sender email address Email Address Input the recipient email address The message in the email Indicate OutletA H XXXXXXXX status in order X 0 means the power off X71 means the power on Note Make sure DNS server can resolve the Email Server s domain name Total load 0 0 A Status Normal Information IP Address PDU Host Name DIGIBOARD IP Address 192 168 1 103 System Subnet Mask Configuration Gateway 192 168 1 1 Threshold Enable DHCP 2 DNS Server IP Network Primary DNS IP 192 168 0 1 Mail Secondary DNS IP 192 168 0 1 SNMP SSL Total load 0 0 A Status Normal Email Setting PDU l Email Server System Configuration Sender s Email Threshold Recipient s Email Address User Email Address Network Vai WEB INTERFACE CONFIGURATION SNMP When event occurs PDU can send out trap message to pre defined IP address neutronics Trap Notification Set receiver IP for trap Community Set SNMP community Read Community is public and fixed Default Write Community is public and can be modified POY Receiver IP 192 168 0 1 by user System Configuration Apply Total load 0 0 4 Status Normal Information Trap Notification Threshold Community User Read public Network Write public Mail Apply SNMP SSL CONFIGURATION SSL
5. manual has been carefully checked and is believed to be accurate We assume no responsibility for any infringements of patents or other rights of third parties which may result from its use We assume no responsibility for any inaccuracies that may be contained in this document We make no commitment to update or to keep current the information contained in this document We reserve the right to make improvements to this document and or product at any time and without notice COPYRIGHT NOTICE No part of this document may be reproduced transmitted transcribed stored in a retrieval system or any of its part translated into any language or computer file in any form or by any means electronic mechanical magnetic optical chemical manual or otherwise without express written permission and consent Copyright 2015 All Rights Reserved Version 1 2 DEC 2014 TRADEMARK ACKNOWLEDGMENTS All products or service names mentioned in this document may be trademarks of the companies with which they are associated FEATURES FEATURES Built in web server manager monitors the current consumption of the power strip in real time Built in true RMS current meter Easy setup meter can read directly or VIA the IP address Homepage support SSL Provides audible alarm when the power consumption goes beyond the threshold of warning and overload Sends an email and traps when the power consumption exceeds the trigger value
6. of warning or overload to the PDU Provided software utility it can monitor multiple PDU s at the same time Supports SNMP and provides MIB for the PDU to be monitored by NMS Provide per outlet power protection by the circuit breaker TOTALPDU PER OUTLET TIME TEMPERATURE iene CURRENT CURRENT or REFERENCE VIA amp HUMIDTY MONITORING MONITORING TIME SERVER OPTION ANI 15115 08MTH wem LL Ll FUNCTION INTERFACE METER i Ethernet RJ45 port for network communication port Audible Alarm Warning 1 beep in 1 second Overload 3 beeps in 1 second Note The audible alarm will keep beeping until the current returns to normal and the current is lower than the threshold of 0 5 amps Function Button Press and release to turn off the warning beep The overload beeping can not be cancelled Hold the button and release after 1 beep The meter will show the current information temperature and humidity in sequence Hold the button and release after 2 beeps The meter will show the IP address Hold the button and release after 4 beeps It will change the IP from DHCP or fixed IP Hold the button and release after 6 beeps It will reset the PDU back to factory setting o Meter 3 digits to display current IP Address and temperature and humidity ID The identification of power bank or PDU Q LED Indicator SSL yellow Light on means that web access is protected by SSL DHCP green
7. ANI 15115 08MTH PDU Total Current Monitoring INSTRUCTION MANUAL n Neutronics 122 Rose Ln Suite 303 Frisco Texas 75034 TOLL FREE 1 877 ANEUTRON TOLL 469 362 9228 Email sales a neutronics com A Neutronics com 16 17 18 SAFETY INFORMATION To ensure the best results from this product please read this manual and all other documentation before operating your equipment Retain all documentation for future reference Follow all instructions printed on unit chassis for proper operation To reduce the risk of fire do not spill water or other liquids into or on the unit or operate the unit while standing in liquid Make sure power outlets conform to the power requirements listed on the back of the unit Keep unit protected from rain water and excessive moisture Do not attempt to clean the unit with chemical solvents or aerosol cleaners as this may damage the unit Dust with a clean dry cloth Do not use the unit if the electrical power cord is frayed or broken The power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them paying particular attention to cords and plugs convenience receptacles and the point where they exit from the appliance Do not force switched or external connections in any way They should all connect easily without needing to be forced Always operate the unit with the AC ground wire connected to the electrica
8. Light on means that PDU gets IP address through DHCP PDU green Indicate each output power status Status red Indicate each circuit status 7 ENV RJ11 for option ENV probe attached to detect temperature and humidity O Circuit Breaker Overload power protection INSTALLATION RACK MOUNT INSTRUCTIONS This section will provide a quick instruction to install the PDU A Elevated Operating Ambient If installed in a closed or multi unit rack assembly the operating ambient temperature of the rack environment may be greater than room ambient Consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature specified by the manufacturer B Reduced Air Flow Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised C Mechanical Loading Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading D Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on over current protection and supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this concern E Reliable Grounding Installation should be in accordance with all governing entities to include but not limited to yo
9. l system ground Precautions should be taken so that the means of grounding of a piece of equipment is not defeated AC voltage must be correct and the same as that printed on the rear of the unit Damage caused by connection to improper AC voltage is not covered by any warranty Turn power off and disconnect unit from AC current before making connections Never hold a power switch in the ON position This unit should be installed in a cool dry place away from sources of excessive heat vibration dust moisture and cold Do not use the unit near stoves heat registers radiators or other heat producing devices Do not block fan intake or exhaust ports Do not operate equipment on a surface or in an environment which may impede the normal flow of air around the unit such as a bed rug carpet or completely enclosed rack If the unit is used in an extremely dusty or smoky environment the unit should be periodically blown free of foreign dust and matter To reduce the risk of electric shock do not remove the cover There are no user serviceable parts inside Refer all servicing to qualified service personnel There are no user serviceable parts inside When moving the unit disconnect input ports first then remove the power cable finally disconnect the interconnecting cables to other devices Do not drive the inputs with a signal level greater than that required to drive equipment to full output The equipment power cord should be
10. unplugged from the outlet when left unused for a long period of time Save the carton and packing material even if the equipment has arrived in good condition Should you ever need to ship the unit use only the original factory packing Service Information Equipment should be serviced by qualifier service personnel when A The power supply cord or the plug has been damaged B Objects have fallen or liquid has been spilled into the equipment C The equipment has been exposed to rain D The equipment does not appear to operate normally or exhibits a marked change in performance E The equipment has been dropped or the enclosure damaged THIS SAFETY INFORMATION IS OF A GENERAL NATURE AND MAY BE SUPERSEDED BY INSTRUCTIONS CONTAINED WITHIN THIS MANUAL TABLE OF CONTENTS CONTENTS Introduction Features Function Installation WebInterface INTRODUCTION The PDU is an Internet ready device designed and equipped with an intelligent current meter True RMS that will indicate the total power consumption of the power strip The PDU offers an easy set up and user friendly communication software This software provides the ability to remotely monitor and evaluate current power consumption INCLUDED The standard PDU package contains a Power Distribution Unit with supporting hardware The components of the package are Power Distribution Unit e Rack mount Brackets rack screws not provided Quick Start Guide AVAILABLE FOR DOWNLOAD
11. ur local electric code etc DIAGRAM i PDU Install In the Rack PDU Install In the Rack PDU Install In the Rack PDU Install In the Rack Local Monitor n PDU Install In the Rack PDU Install In the Rack Remote Monitor d 2 The multiple PDU power m2 5 HARDWARE 1 Install mounting brackets 2 The PDU comes with brackets for mounting in a rack To mount the PDU into a rack perform the following procedure e Attach the mounting brackets to the unit using the four retaining screws provided for each of the brackets Choose a location for the brackets e Align the mounting holes of brackets with the notched hole on the vertical rail and attach with the retaining screws 3 Connect input and output power 4 Connect Ethernet cable to the PDU 5 Switch on the PDU Note 1 The default setting IP address is DHCP If PDU can not get the IP address from DHCP server the IP address will stay at 192 168 0 216 WEB INTERFACE LOGIN Input the PDU IP address in web browser User Name snmp Password 1234 Note Screen shots for reference only Actual prompts might du iani diee vary slightly Warning This server is requesting that your username and password be sent in an insecure manner basic authentication without a secure connection User name INFORMATION PDU Displays total PDU and each outlet power consumption Q A Neutronics Total load 0 0 A Status Information PDU
Download Pdf Manuals
Related Search
Related Contents
AVIATION C I V I L E CATSIM Manual - International Association for Computerized Manual - Keene Electronics HYPOnet-Retail User Manual_20100204_ENGv1.20 CD-212 Aspen - Ditália Móveis attachment_id=1051 - Buckner Blog ダウンロード Nieco Ex6220 Toaster 6220-FR_Nieco MPB94 Manual CD5 - CEC Copyright © All rights reserved.