Home
Alert Eagle® 100 and 120 Decoders 07/21/15
Contents
1. The user configures a text file of events and locations to match against the incoming alert SAME EAS alert message Upon detecting a match the AE will close a relay and if connected to a Weather Eagle WEATHER EAGLE will unmute the WEATHER EAGLE for a period of time until either end of message signal is decoded or the timeout which default is 90 seconds At the end of the alert period the relay will open and the WEATHER EAGLE will re mute As a result of years of research and development the AE has many patented diagnostic features that provide the user with positive feedback about the operation of the system These include a FSK Lock detect LED digitally saving the last alert into the AE including each SAME EAS burst and the event and location matched and whether the End of Message signal has been decoded An Audio In port is provided to enable the user to test the system with recorded wav audio files The operation of these features will be described in this document The AE may be installed as a filter to automatically place selected weather warnings and live weather reports on other communication systems such as public address systems and police fire public utility radio systems etc in manners that should minimize disruption of the other communication system The AE is engineered for durability with modern surface mount technology and few moving parts The AE has special audio filters and amplifiers to provide the m
2. protection for the unit The AE is operational as soon as it receives power There is NO on off switch If the AE is used with the WEATHER EAGLE the power from the AE will power the WEATHER EAGLE and NO second power supply is needed The unit may also be operated from any 12 volt DC negative ground system in a car boat or other vehicle Vehicle connections should be protected by a 1 amp fast blow fuse An optional fused cigarette lighter adapter is available from the Thunder Eagle Inc 2 Programming the Match Events and Locations The user can select any combination of the 53 possible events and any of the over 5500 location codes to match BOTH the event and the location need to match for the AE to activate the alert sequence The AE can hold up to approximately 2000 match codes although most users will usually have less than 31 match locations programmed into the AE as each NWS transmitter can transmit up to a maximum of 31 locations Each transmitter only transmits the locations in the transmitter s broadcast coverage area Check www weather gov nwr for transmitter county code coverage All events and the nationwide 000000 code are defaults It is highly recommended to also include each statewide alert code for every state that you can monitor These are in the FipsFilemaker database and are in the format of OXX000 where the XX is the state code For example 051000 is the statewide code for Virginia Many important alerts suc
3. S EOM signal to reset the AE 5 Reset Button Pressing the reset button resets the AE mutes the WEATHER EAGLE opens the alert relay and sends a reset message to comm port and Hyperterminal 9600 baud 8 N 1 NO flow control 6 Last Alert Button Pressing the Last Alert button sends the details of the last received alert to the AE comm port 1 and Hyperterminal 9600 baud 8 N 1 NO flow control with the following information a Each of the 3 possible 3 bursts received ZCZC WXR RWT 011001 024009 02401 7 024021 024031 024033 024037 051013 051043 0510 47 051059 051061 051099 051 107 051 113 051137 051153 051157 051177 051179 0 051510 051600 051610 051630 051683 051685 054037 0030 2761515 KLWX NWS A ZCZC WXR RWT 011001 024009 02401 7 024021 024031 024033 024037 051013 051043 0510 47 051059 051061 051099 051 107 0511 13 051137 051 153 051 157 051 177 051 179 051 187 051510 051600 051610 051630 051683 051685 054037 0030 2761515 KLWX NWS ZCZC WXR RWT 011001 024009 02401 7 024021 024031 024033 024037 051013 051043 0510 47 051059 05106 1 051099 051 107 0511 13 051137 051 153 051 157 051177 051179 051187 051510 051600 051610 051630 051683 051685 054037 0030 2761515 KLWX NWS A b Whether an Event match was found and which one 2004 2015 Thunder Eagle Inc All rights reserved worldwide Alert Eagle 100 and 120 Instruction Manual Page 8 EventMatchFound RWT RWT RWT 2 c Whether a Location Match was found and wh
4. Thunder Eagle Inc P O Box 625 b Vienna VA 22183 2 Q tel 703 242 0122 Mase uae toll free 1 888 553 2928 Senan fax 703 281 7459 email support thuneagle com website www thuneagle com ALERT EAGLE 100 and 120 Diagnostic SAME EAS Decoder and System Interface 07 21 15 The Alert Eagle 120 is an upgraded version of the ALERT EAGLE 100 Most of the features are the same in both units The Alert Eagle 120 has a smaller foot print approx 6 x 4 75 vs 7 x 6 and diodes have been added to the output lines to make interfacing easier The test button has been added to the outside of the case Instruction Manual 1 Power Supply 12VDC Wall Transformer Battery Backup UPS 2 Programming the Match Events and Locations 3 Readback the AE Match Database 4 Set the Alert Activation Time 5 Reset Button 6 Last Alert Button 7 Test Button 8 Audio Input and FSK Lock LED 9 Description of Front Panel LEDs 10 Description of Rear Panel Connections 11 Location of Decoder 12 Upload New Firmware 13 WEATHER EAGLE 110 Settings for Use with AE 120 14 Specifications 15 Warranty Product Description The patented AE diagnostic SAME EAS Specific Area Message Encoded Emergency Alert System decoder monitors unmuted audio and decodes SAME EAS alert messages 2004 2015 Thunder Eagle Inc All rights reserved worldwide Alert Eagle 100 and 120 Instruction Manual Page 2
5. arantee that ThunderEagle products will perform flawlessly in all circumstances If the Buyer cannot accept this risk the products should not be purchased In no event shall ThunderEagle be liable for any special indirect incidental or consequential damages arising out of or as a result of the sale delivery servicing or loss of use of the equipment or any part thereof or for any charges or expenses of any nature incurred This warranty is in lieu of all other warranties including without limiting the generality of the foregoing warranties of merchantability and fitness for a particular purpose express or implied Printed in U S A 2004 2015 Thunder Eagle Inc All rights reserved worldwide Connection From WE110 to Audio Amplifier Using AE120 Relay to Gate the Audio for Alerts Active Only AE120 WE110 Relay Green Connector Center 2 pins NO Common RCA cable to Unmuted Audi Only closes on Weather Alert Match Event and Location Audio is line level full time for 90 seconds Green UnMuted ag Gnd Ground Is Continuous ONLY break center conductor through relay l Gnd xxMake sure FSK lock led is still flashing after connection has been made Audio In To Amp Press the test button on the AE120 to test the audio to the PA system Press the reset button on the AE120 to reset the system Audio Amplifer All Audio is Broadcast Copyrig
6. audio to the decoder to be attenuated and will make the AE not perform properly The FSK lock light MUST be flashing to decode the NWS EAS SAME signal c Remote Control This is a db15 The pin out is as follows 1 WEATHER EAGLE Manual channel change 5 VDC active high 2 WEATHER EAGLE Scan 5 VDC active high 3 Reset pulse to the WEATHER EAGLE on alert 5 VDC active high 4 Live pulse to the WEATHER EAGLE on alert 5 VDC active high 5 Relay common 6 Relay normally open 7 Relay normally closed 8 Busy Input into the WEATHER EAGLE 9 Unmuted SAME EAS audio input 10 Muted audio from the WEATHER EAGLE 11 12 VDC from the WEATHER EAGLE or AE 2004 2015 Thunder Eagle Inc All rights reserved worldwide Alert Eagle 100 and 120 Instruction Manual Page 11 12 N C 13 WEATHER EAGLE play 5 VDC active high 14 N C 15 Ground See the interface schematic on www wxeagle com d Audio In Place SAME EAS high impedance audio into this port CAUTION DO NOT leave this test connected to an external audio source if you plan to receive alert audio from the WEATHER EAGLE It is permissible to insert external text audio into this port for testing while the AE is connected to the WEATHER EAGLE e 12VDC Power In 11 Location of Decoder Like any piece of electronic equipment the AE should be kept in a warm and dry location away from direct heat sources and out of direct sun
7. cal character echo and add line feeds to incoming data c Hold in the Last Alert button on the AE while you power up the unit and the programmed database should appear on your Hyperterminal Review the match events and locations for accuracy 4 Set the Alert Activation Time a Connect the AE to your workstation s comm port b Open a Hyperterminal session start programs accessories communications Hyperterminal Create and save a new connection with the following parameters 9600 baud 8 N 1 NO flow control c Hold in the Reset Program button AND the Last Alert button on the AE while you power up the unit and the Alert Time menu should appear on your Hyperterminal 2004 2015 Thunder Eagle Inc All rights reserved worldwide Alert Eagle 100 and 120 Instruction Manual Page 7 d The default setting for the relay to close and the WEATHER EAGLE to unmute on an alert is 1 minute and 30 seconds You can reset the time by choosing menu option 1 and N for new Then press in the hours minutes and seconds of the alert time Then press E to end the menu session The alert time can be set from 1 second to 2 minutes e Power down and power up the AE Note In addition to the timeout menu the AE will automatically reset upon decoding the NWS End of Message signal The NWS signal should issue not more than two minutes after the beginning of the alert If the timeout is set for more than two minutes it will act as a backup to the NW
8. ceiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help 2004 2015 Thunder Eagle Inc All rights reserved worldwide Alert Eagle 100 and 120 Instruction Manual Page 14 Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device 15 Warranty Procedure 1 Refer to Operating Instructions Section of this User s Manual for proper operation 2 If the above procedures do not correct the problem you are experiencing with your unit return the unit with proof of purchase to where purchased for warranty exchange or further warranty instructions Limited One Year Warranty Equipment manufactured and sold by Thunder Eagle Inc ThunderEagle is warranted to be free from defects in workmanship and materials for a period of one 1 year from date of shipment If dissatisfied with the equipment within thirty 30 days of receipt the Buyer may return the equipment freight pre paid to ThunderEagle for a refund The Buyer MUST contact ThunderEagle for a RMA Return Merchandise Authorization before returning any equipment Shipments received without a RMA will
9. ches BOTH the last Event and Location c FSK Lock Lights when the input audio is in the alert audio passband See above description of operation d Relay Lights during the alert cycle when the relay is closed and the WEATHER EAGLE is unmuted e EOM Lights when the EOM signal has been detected f Data Flashes as data is moved in and out of the digital memory This is a great diagnostic You will see this LED flash briefly at the end of each SAME EAS burst 2004 2015 Thunder Eagle Inc All rights reserved worldwide Alert Eagle 100 and 120 Instruction Manual Page 10 as the data is saved to memory and you will see this light flash during the match sequence at the end of each new alert sequence g Power This light indicates that the AE has power 10 Description of Rear Panel Connections a Commi This is a standard 3 wire serial port using pins 2 3 and 5 Pins 2 and 3 are transmit and receive but can be reversed instead of using a null modem cable by reversing the position of jumpers J66 and J71 Change both settings so one jumper is from pins 1 2 and the other are from pins 2 3 Pin 5 is a ground b Relay Output A removable green screw terminal wire connector has outputs for 1 Ground 2 Relay Normally Open 3 Relay Common and 4 Audio Out which can be either muted audio or unmuted audio CAUTION Connect this output to ONLY a high impedance audio device Low impedance audio devices will cause the
10. e These files can be edited by the user to add new alerts and locations so there will be no delay in decoding new alerts as the SAME EAS system evolves The alert match text file is easily uploaded from a user s workstation using the Thunder Eagle free FipsFileloader software These software programs are available to Thunder Eagle customers at www wxeagle com login User names and passwords will be provided to Thunder Eagle clients A watch means that conditions are favorable for the occurrence of severe weather A warning means that severe weather is imminent You may which to contact your local forecast office or www weather gov for further information The NWS normally tests the tone alert system once per week on Wednesdays between the hours of 11 a m and noon if no severe weather is anticipated Please make sure that your AE receives the weekly alert message 1 POWER SUPPLY The AE is powered by 12 volts DC The unit draws about 100 milliamps Plug the wall transformer into 120 volt AC 60 Hz and plug the 2 1 mm plug center positive 2004 2015 Thunder Eagle Inc All rights reserved worldwide Alert Eagle 100 and 120 Instruction Manual Page 4 connector into the rear panel of the unit Where available it is recommended that the AE be plugged into an uninterruptable power system to provide service during power failures A computer UPS of 500VA should power the AE for 24 to 36 hours and will also provide power surge
11. e manager ports comm lpt and the comm port numbers should be listed f Press the FipsLoader connect button and a green icon indicating that the Alert Eagle is Ready to Program should appear g Press the Erase button and OK in the confirmation message box and the AE memory should erase This should take less than 90 seconds The memory must be erased before programming to prevent prior information stored in the memory from causing unreliable operation Once the memory has been erased the new match file MUST be uploaded for any matches to occur 2004 2015 Thunder Eagle Inc All rights reserved worldwide Alert Eagle 100 and 120 Instruction Manual Page 6 h Click the Select File button and navigate on your drives to the text file you created with the FipsFileMaker i Click the Upload button and the uploading progress should take less than one minute and is tracked by the progress bar and by the byte counter j When the file has been successfully uploaded a green success icon will appear If it does NOT appear retry the above steps k Power up the AE Close FipsFileLoader 3 Readback the AE Match Database a Connect the AE to your workstation s comm port b Open a Hyperterminal session start programs accessories communications Hyperterminal Create and save a new connection with the following parameters 9600 baud 8 N 1 NO flow control In Hyperterminal setting asci set up you should check lo
12. ed worldwide Alert Eagle 100 and 120 Instruction Manual Page 13 14 Specifications Specifications are nominal unless otherwise indicated and are subject to change without notice General Input voltage 12 volts DC adapter or battery Dimensions 3 25 x 8 x 6 H x W x D Alarms relay text and visual DC input power 12 volts DC less than 100 milliamp draw FCC Industrie Canada Compliance Statements FCC Part 15 21 requires that the Manual include the following statements Changes or modifications not expressly approved by the manufacture could void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the re
13. h as the Amber missing child alert are transmitted with the 0XX000 statewide code The FipsFileMaker software will verify the format of the file 2004 2015 Thunder Eagle Inc All rights reserved worldwide Alert Eagle 100 and 120 Instruction Manual Page 5 before it permits the file to be saved Save the file in a location on your workstation where you can find it with the FipsFileLoader software If needed the user can edit the text file in the FipsFileMaker to add new event codes or location codes This will be very important as the SAME EAS system evolves and changed With this field upgrade system there should be no need to have your unit out of service or to be returned for upgrade Use the following steps to load the match text file into the AE a Unplug the AE b Open the FipsFileLoader software on your workstation c Connect the supplied standard serial cable between your workstation s comm port and the comm1 port on the rear of the AE d HOLDING IN the AE Reset Program button plug the power into the AE The AE should enter programming mode as shown by the Match and No Match LEDs staying lit e Open the FipsLoader software and open the comm port on your workstation Make sure you get a green confirmation light that the comm port is open On XP you can quickly find which comm ports are installed on your workstation by right clicking on the My Computer desktop icon then go to properties hardware devic
14. ht 2015 Thunder Eagle Inc All rights reserved worldwide DESION TILEE WE110 Relay Audio Connection Date Created REVISION A SHEET OF 04 12 15
15. ich one Location Match Found 051059 051059 051059 2 d Whether the End of Message signal was decoded End of Message Signal Received This information provides a wonderful diagnostic for the entire system If a good signal is being received at least two of the three bursts should regularly decode If one or no bursts are decoded try to improve your signal quality by changing antenna location or using an outside and or directional antenna By reviewing the SAME EAS Location codes you will learn what codes are being transmitted on your local transmitter and you can adjust your match files accordingly 7 Function Test Button The function test button is located INSIDE the AE 100 and outside the AE120 and provides a way to quickly test the core functions of the AE Pressing the function test button causes a The Match No Match Relay and EOM leds to light b The WEATHER EAGLE to unmute and then remute c The relay to close d The match database to output on the rs232 port 9600 8 N 1 e The software version number to output on the rs232 port This button will be very useful for system diagnostics 8 Audio Input and FSK Lock LED The AE needs clean filtered audio with an amplitude of about 100mV millivolts peak to peak The audio is input into the AE from ONE use only one audio input at a time source a RCA connector on the rear of the AE b DB15 connector on the rear of the AE pi
16. light Better reception may be obtained by moving the AE to a different location away from operating equipment Computers and monitors generate significant RF and compete against the relatively weak NOAA All Hazards radio signals to capture the receiver Always verify that you have good reception in order to receive severe weather alerts Make sure you receive the weekly test 12 Upload New Firmware The AE is operated by a powerful computer microcontroller with electronically flash program memory You need the ICD 40S programmer to update the firmware Install the ICD 40S on your workstation Open the AE case With the AE powered on plug the ICD 40S into the RJ 45 on the AE and plug the serial connector into your workstation 2004 2015 Thunder Eagle Inc All rights reserved worldwide Alert Eagle 100 and 120 Instruction Manual Page 12 MAKE SURE YOU ONLY UPLOAD AE SOFTWARE TO THE AE A progress bar should appear and the download and file verification should take less than 30 seconds Click the Run Program button The AE should come to life Press the buttons on the AE to make sure the download was successful and to test the unit with a test wav audio file Unplug the ICD 40S from the AE and from your workstation Reassemble the AE case and close the ICD 40S software 13 WEATHER EAGLE Settings for Use with AE Holding in the Manual button on the WEATHER EAGLE during powerup with the WEATHER EAGLE connected to Hy
17. n 9 or c a ribbon cable to the WEATHER EAGLE inside the AE 2004 2015 Thunder Eagle Inc All rights reserved worldwide Alert Eagle 100 and 120 Instruction Manual Page 9 When the unit is powered up and audio is applied to the AE the FSK Lock LED on the front panel should flash each time the audio passes through the SAME EAS audio passband Thus by looking at the FSK Lock LED you can tell if the decoder is receiving audio and whether the unit is locked onto a SAME EAS alert during which the LED should stay on solidly for the duration of each SAME EAS burst The decoder can be tested by placing a recorded wav audio file into the rear RCA audio in jack of the AE using a standard workstation s Sound Recorder start programs accessories communications sound recorder Connect a cable between the workstations speaker output 1 8 phono the RCA jack on the rear of the AE Audio cables and adapters are available from many electronic stores The audio volume on your workstation should be set no higher than 1 3 of maximum volume The AE responds well to low audio level signals High level signals despite the AE s filters may cause distortion of the signal and a failure to properly decode Sample wav files are posted on www wxeagle com support audiofiles 9 Description of Front Panel LEDs a No Match Lights when the last alert does NOT match EITHER the Event or the Location b Match Lights when the last alert mat
18. not be accepted by ThunderEagle Should any item manufactured by ThunderEagle become defective during the warranty period it will be repaired or replaced at ThunderEagle s sole discretion Warranty repairs made at ThunderEagle s factory or in the field shall be at no charge to the customer ThunderEagle shall pay SURFACE transportation charges both ways within the contiguous United States if the equipment proves to be defective WITHIN 30 DAYS from the date of shipment Throughout the remainder of the warranty period the customer shall pay transportation charges to return the equipment to ThunderEagle and ThunderEagle shall pay SURFACE transportation charges to return the repaired equipment to the customer All requests for warranty service must be received within the warranty period All ThunderEagle warranties are contingent upon the proper use of the equipment and will not apply if the equipment is subjected to unusual physical stress neglect misuse or inadequate storage Damage caused by electrical power surge lightning water temperature and or other environmental causes are SPECIFICALLY EXCLUDED from this warranty The Buyer by acceptance of the equipment assumes all liability for consequences of its use or misuses by the Buyer the Buyer s employees and or all others No amount of engineering will 2004 2015 Thunder Eagle Inc All rights reserved worldwide Alert Eagle 100 and 120 Instruction Manual Page 15 gu
19. ost reliable SAME EAS decoding capabilities The AE is especially useful for emergency operations centers security offices mobile communications vehicles command posts and search and rescue units when combined with audio supplied by the WEATHER EAGLE The firmware in the AE is flash memory for customer field upgrade using the optional Thunder Eagle programmer Upgraded firmware may be posted on www wxeagle com login and downloaded by the client and then programmed into the 2004 2015 Thunder Eagle Inc All rights reserved worldwide Alert Eagle 100 and 120 Instruction Manual Page 3 AE This feature will prevent unit downtime and will eliminate shipping time and expense in keeping the unit in operation The AE has many different configurations It can be standalone in a plastic case 19 rack mounted alone and 19 rack mounted with the WEATHER EAGLE NWR is broadcast from over 1000 transmitters located throughout the United States and Canada on seven FM channels operating between 162 400 MHz and 162 550 MHz Most populated areas of the United States and Canada are covered by at least one channel Some areas are covered by more than one channel Maps and a database of the NWR transmitters and a listing of the county location codes and which location codes are broadcast on each transmitter are located at www weather gov nwr The alert match text file is easily created by using the Thunder Eagle free FipsFilemaker softwar
20. perterminal 9600 baud 8 N 1 NO flow control Suggested menu options appear below 1 Channel on powerup Last Selected 2 RSSI Tone diagnostics on RS232 port Disable 3 Remote Unmute Logic in Disable 4 Rescan for strongest signal every 60 seconds Disable 5 Relay closure on 1050 alert Disable 6 Live audio on 1050 alert Disable 7 Beep on 1050 alert Disable 8 Set hrs min sec of live audio on 1050 Hz alert or live timeout At least 1 min 30 seconds 9 Set hrs min sec of relay closure on 1050 Hz alert n a A Close relay on Live and Play Enabled D Restore default settings n a E End menu setup routine n a F Live Timeout Reset Enable G Beep channel number Disable The theory of operation is that on a match event and location the AE sends a pulse 5 signal to the Weather Eagle as if the Weather Eagle live button was pressed electronically If the Weather Eagle is also interfaced to an outside remote control and this line is held logic low the AE will be unable to activate the Weather Eagle The solution is to place a diode on the incoming logic line into the Weather Eagle for live and reset See the interface schematic At the end of the alert timeout or EOM decoded the AE sends a reset signal to the Weather Eagle The backup is the live timeout timer which times out a set period after the Weather Eagle goes live 2004 2015 Thunder Eagle Inc All rights reserv
Download Pdf Manuals
Related Search
Related Contents
Linksys DMRW1000 User's Manual iMed 6.1 User Manual Technical Reference Manual Intel Core U1300 500 Amp Carbon Pile Battery Tester User`s Manual UVC-XP4DN-HR(-P) Kamera Benutzer Handbuch Dossier d`information Euro Pharmat - Energie WTP-9A66 Series User`s Manual HP Universal Remote multimedia User's Manual Copyright © All rights reserved.