Home
Digitilt AT System Manual
Contents
1. 33 Digitilt AT Inclinometer System 2014 6 04 About the Symbols Danger High Voltage ZN Warning Warning 6 ER Safety Guide WARNING Before using read the entire user manual After reading store it in a safe place for future reference Incorrect handling of this product could possible result in personal injury or physical damage The manufacturer assumes no responsibil ity for any damage caused by mishandling that is beyond normal usage as defined in this manual NOTE The information in this manual is subject to change without notice The manufacturer assumes no responsibility for any errors that may appear in this manual Various symbols are used in this manual and on the product itself to ensure correct usage to prevent danger to the user and other and to prevent property damage The meanings of these symbols are described below It is important that you read the descriptions thoroughly and fully understand the contents This symbol indicates information that if ignored could possi bly result in personal injury or even death due to electrocution If these warnings are not observed considerable physical injury or property damage may occur as a result of burns electrocu tion fire or injury If these warning are not observed considerable phsical injury or property damage may occur as a result of burns electrocution fire or injury Digitilt AT Inclinometer System 2014 6 04 Saf
2. Display Unit Tap to switch between mm and Digi metric or between inch and Digi English Digi units are explained in a later chapter Depth Unit Fixed to meters or feet Interval Typically 0 5 for metric and 2 for English Top Depth Typically 0 5 for metric and 2 for English Bottom Depth Enter a multiple of 0 5 for metric systems or a multiple of 2 for English systems The reader turns a field red if it finds an unacceptable entry Check that you have entered no spaces punctuation or special characters Also check that top and bottom depths are multiples of the interval Digitilt AT Inclinometer System 2014 6 04 12 Inclinometer Surveys A Grooves Orientation of Probe for O Pass Orientation of Probe for 180 Pass Survey Basics During a survey the probe is drawn from the bottom to the top of the inclinometer casing This is called a pass A complete survey consists of two passes a 0 pass and a 180 pass Inclinometer casing is installed with one set of grooves aligned with the expected direction of movement downhill or towards the excavation These are the A grooves Only the A grooves are used in the survey The AO groove is usually marked for easy identification For the 0 pass insert the probe with the mark facing the AO direction The mark appears on the body of the probe above the top wheels For the 180 pass remove the probe rotate it 180 and insert it with
3. mark is engraved on the body of the probe Use this mark to orient the probe during a survey There are two tilt sensors inside the probe The A axis sensor measures tilt in the plane of the wheels The B axis sensor measures tilt in the plane perpendicular to the wheels When the top of the probe is tilted in the direction tilt values are positive and when the probe is tilted toward the direction tilt values are negative A A A Probe viewed from top The inclinometer probe is a sensitive measuring instrument Handle it with care e Transport the probe in its carrying case if applicable If you drive to the site carry the casing in the passenger compart ment preferably on a passenger seat e For systems with a removable probe avoid over tightening the nut when connecting the control cable to the probe since this will flatten the O ring and reduce its effectiveness e When you insert the probe into the casing cup the wheels with your hands to compress the springs and allow smooth insertion e When you lower the probe into the borehole do not allow it to strike the bottom e When you withdraw the probe from the casing again cup the Digitilt AT Inclinometer System 2014 6 04 Control Cable Cable Gate wheels with your hands to prevent them from snapping out When you rotate the probe keep it upright and perform the rotation smoothly The probe is
4. Mett folder This folder a a SO E Bak KA _ Search Folders holds any updated G 0 leen By roves S d fil Address ICH My Computer Transformer Prime TF201 Internal storage Digi e ux illes ES CH Incinometer Data File Folder Outbox File Folder 5 Copy all the dux files in the Outbox Qm O Glen Er tege 1yntemai storage D 6 Paste the files into a folder on your PC If you are using Digi Pro2 paste them into the default import folder Digitilt AT Inclinometer System 2014 6 04 30 Options User Survey Mode Sound Battery Probe Share About Themes Survey Control Options Menu Tap the Options icon i ah Options icon A user name is saved with the survey Choose a name from the list Tap and hold to edit the list Choose Tap mode if you want to tap the record button to record readings Choose Hands Free if you want to pull the cable rather than tap the button to record readings Choose the sound that the reader makes when you record a reading You can add your preferred sounds by saving a sound file to the reader s Notification folder The sound file will then appear in the list of selectable sounds Displays battery level of the Reader but not the Reel Displays live readings from the probe Tap the units label to specify different units Keep in mind that metric units should be used with metric probe
5. readings Tap or Pull The record button is green when readings are ready to record Tap the button or pull the cable hands free mode to save the readings The button is dark green after readings are saved Tap to record Tap mode Pull cable to record Hands free mode Digitilt AT Inclinometer System 2014 6 04 15 Survey Modes Tap the options icon to change survey mode oe Reader Options icon Choose Tap or Hands Free In Tap mode you tap the record button to save a reading In hands free mode you pull the cable to record the reading There is no need to hold the tablet or tap the screen except at the beginning and end of a pass Survey Mode Tap Hands Free Cancel OK Changing Ifcable depth and active depth get out of sync the Active Depth 1 Tap amp hold the active depth until arrows appear 2 Tap the arrow to change the depth 3 Move the probe to the new depth 4 Tap OK to resume the survey The new in sync readings overwrite the previous out of sync readings e Digitilt Reader AlphaSite Inclin01 AN 0 D D 0 1 Tap amp hold the active depth V 2 Tap arrow to change the depth 15 5 0 00 mm 0 00 3 Move the probe to the new depth then tap OK to resume the survey Digitilt AT Inclinometer System 2014 6 04 16 Resuming an Interrupted Survey Halting a Survey The Reader keeps a book
6. susceptible d en compromettre le fonctionnement CCE X This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This Class B digital apparatus complies with Canadian ICES 003 Contains IC ID 65144 RN411 Model T9JRN41 1 A Contains FCC ID T9JRN41 1 3 Polarity CA Do not charge with AC power in a wet location Input I5V 1A Digitilt AT Inclinometer System 2014 6 04 38
7. that time the app will not accept new input The default is 2 seconds Pull Lockout Same as above but used for hands free mode Lockout is more important for hand free mode Experiment to find the right lockout timing New users may be more comfort able with a lockout of 3 seconds or more Expert users who develop a rythm may prefer a 2 second lockout Turns off the Bluetooth connection and closes the reader app Digitilt AT Inclinometer System 2014 6 04 32 Inspection amp Maintenance Probe Inspection Wheel yoke all systems Wheel all systems Connector keyways connector systems only Connector O ring connector systems only Connector pins connector systems only Probe Maintenance Moisture Management all systems Wheels all systems O Ring connector systems only Yoke does not return to fully extended position If yoke is dirty clean it If problem persists spring may be broken or weak Does not turn freely Lubricate wheel bearings with light machine oil Wear or corrosion Worn keyway may degrade O ring seal Learn how to connect cable without hunting Remove corro sion and change practice allow connector to dry after use Flattened split Replace if flattened or split Bent pins Bent pins are easily broken when straightened Replacement of connector requires recalibration of probe Change connection practice Wipe off the control cable and probe when you fin
8. the mark facing the A180 groove AO Groove G ap E we IS vis el z JE Ue st IO U OI E QO toward A180 groove Digitilt AT Inclinometer System 2014 6 04 13 The Survey Screen The survey screen guides you through the survey bass Screen The elements of the survey screen are explained below e Digitilt Reader Inclinometer Name alphasite inclino2 D 18 5 Pass Active Depth 19 0 Last Recorded Depth A 0 5 __ A Reading Unit mm B 0 0 B Reading Progress Bar Record button 180 Pass Screen The 180 Pass screen adds checksums and a second progress bar AlphaSite Inclino2 1s0 180 Pass D 4 0 4 5 A 2 80 0 14 A Checksum mm B 5 01 0 22 B Checksum 2nd Progress Bar Digitilt AT Inclinometer System 2014 6 04 14 The Record Button The record button has multiple colors and functions Start amp End The record button is orange at the start and end of each pass Tap Start to enable recording Tap End to disable recording This prevents accidental recording of readings when you position the probe for each pass Tap to start recording Tap to end recording Wait The record button is yellow when readings are not stable You can tap the Wait button to record a reading if necessary Wait for stable
9. the tablet and reel to connect and communicate 1 Switch on the Bluetooth reel The blue LED starts blinking 2 Switch on the tablet 3 Tap the Settings icon and find Wireless and Network 4 Enable Bluetooth 5 Enable Search for devices If you dont see this setting try tapping the Bluetooth entry 6 After a short delay the tablet shows Bluetooth devices that are available for pairing Each device has an ID or name 7 Tap the ID that matches the Bluetooth label on the back 903301 00 100 ft side of the reel The example ee at right shows FireFly 4DC9 as the Bluetooth ID 8 The tablet will either a ask for a PIN Enter 1234 b show the image below Press Pair d To pair with FireFly 334E Make sure it is showing this passkey 169686 Cancel 9 Finally look for a message confirming that the devices is paired Digitilt AT Inclinometer System 2014 6 04 Installing the Reader App Downloading amp Installing The Digitilt Reader app is available from the Google Play Store the Reader App 1 Start the Google Play app on your Android device 2 Search for Digitilt Reader 3 Tap Install when the app appears Digitilt Reader DURHAM GEO SLOPE INDICATOR Divas Oct 29 2012 12mg DESCRIPTION The Digitilt Reader app transforms a qualified Android RATE amp REVIEW device into a full featured inclinometer readout for use with the Digitilt AT Incli
10. 46 0 16 7 Tap the record button when it is green D 0 5 1 0 A 5 28 0 01 B 4 47 0 17 8 Tap End 180 Pass TS The survey is complete The Reader saved p 0 5 readings during the survey so there is no need to save anything now When you tap the End button the Reader takes you to the Plots screen Digitilt AT Inclinometer System 2014 6 04 22 Plotting Inclinometer Surveys Introduction The Reader app can display four types of plots These are useful for validating the survey The Reader cannot print plots Use DigiPro2 for that e Digitilt Reader X Change From Initial A B 0 0 6 6 12 12 5 S 30 15 0 15 30 30 15 0 millimeters millimeters Current 2012 10 08 16 11 Last 2012 10 05 13 58 Initial 2012 10 03 10 34 Checksums Checksums are the sum of the 0 and 180 reading at each depth The ideal checksum is 0 In practice checksums are typically some non zero value Checksum plots are displayed in the read ing units used in the survey Change from Initial This plot shows changes in profile cumulative displacement current initial last initial and initial initial which plots on the 0 line Change from Last This plot shows change in profile from the last survey Calcula tions are current last and last last which plots on the 0 line Profile This plot shows the casing profile cumulative deviation D
11. A Regulatory Notices This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio commu nications NOTICE This Class B digital apparatus complies with Cana dian ICES 003 This device complies with Industry Canada licence exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Le pr sent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radio lectrique subi m me si le brouil lage est
12. Digitilt AT System Manual 50330999 Copyright 2014 DGSI All Rights Reserved This equipment should be installed maintained and operated by technically qualified personnel Any errors or omissions in data or the interpretation of data are not the responsibility of Durham Geo Slope Indicator DGSI The information herein is subject to change without notification This document contains information that is proprietary to DGSI and is subject to return upon request It is transmitted for the sole purpose of aiding the transaction of business between DGSI and the recipient All information data designs and drawings contained herein are proprietary to and the property of DGSI and may not be reproduced or copied in any form by photocopy or any other means including disclosure to out side parties directly or indirectly without permission in writing from DGSI SLOPE INDICATOR 12123 Harbour Reach Drive Mukilteo Washington USA 98275 Tel 425 493 6200 Fax 425 493 6250 E mail solutions slope com Website www slopeindicator com Contents Safety Guide 1 System Components 3 Pairing Tablet amp Reel 8 Installing the Reader App 9 Reader App Overview 10 Adding Inclinometers 11 Survey Basics 13 Survey Run Through 18 Plotting Surveys essneennnen 23 Sending Data 25 Options Menu cee cece 31 Inspection amp Maintenance
13. ICATOR AlphaSite Inclin01 dux AlphaSite Inclin02 dux AlphaSite Inclin03 dux BetaSite Inclin01 dux BetaSite Inclin02 dux BetaSite Inclin03 dux DeltaSite Inclin12 dux DeltaSite Inclin14 dux DeltaSite Inclin70 dux GammasSite Inclin01 dux KappaSite Inclin06 dux ZetaSite Inclin58 dux AlphaSite Inclin02 0 D 20 0 the survey Insert the probe with mark facing the A AO groove and lower it to the start depth mm 5 Place the cable gate onto the casing and lock in the cable 6 Wait ten minutes for temperature adjustment You can switch off the Reader while you wait Digitilt AT Inclinometer System 2014 6 04 Run the 0 Pass 1 Switch on the Reader and tap Start 0 Pass 2 The A and B readings appear Readings are stable so the record button is green Tap to record 3 The Reader displays the next active depth Raise the probe to this depth and wait for stable readings The last recorded depth appears just below the new active depth 4 Tap the record button when it is green 5 The Reader displays the next active depth Raise the probe to this depth wait for stable readings and then tap the record button 6 Repeat these operations until the probe reaches the top depth AlphaSite Inclin02 D 20 0 A 2 42 B 6 72 eo D 19 5 20 0 A 1 84 B 6 91 D 19 5 20 0 A 1 85 B 6 91 Digitilt AT Inclinome
14. erge the reel If it is necessary to clean the connector use a cotton swab moist ened with alcohol Sockets can be cleaned with a brush Do not use spray lubricants or electric contact cleaners Solvents contained in such products will attack the neoprene inserts in the connectors Digitilt AT Inclinometer System 2014 6 04 35 Technical Details Reading Units The Digitilt AT stores tilt readings as 100000 x sine 9 where 0 is the angle of tilt During the survey the Reader app displays the following units Metric Units e mm of deviation assuming a 500 mm gauge length e digi metric 25000 x sine 0 the metric unit displayed by the Digitilt DataMate readout English Units inches of deviation assuming a 24 inch gauge length digi English 20000 x sine 0 the English unit displayed by the Digitilt DataMate readout Inclinometer dux Files The Digitilt Reader app creates a file for each inclinometer The file has a dux extension For convenience it is called a dux file The dux file contains the parameters of the inclinometer depth etc and all the surveys for that inclinometer New surveys are appended to the end of the file Folders The Digitilt Reader app creates the following folders within the Android system Download Folder Digitilt Reader Top Level folder Inclinometer Data This folder holds all the inclinometer dux files The Reader app scans the Inclinometer Data folder to create its li
15. ety Precautions Warning Warning l Warning When unit is connected via the charger to high voltage AC mains the possibility of personal injury or even death due to electrocution exists Charge only indoors Do NOT charge when wet Digitilt AT Inclinometer System 2014 6 04 About Inclinometers System Components system Components An inclinometer system includes inclinometer casing and a portable probe control cable and readout Inclinometer casing is permanently installed in a near vertical borehole that passes through a zone of suspected movement The probe cable and readout are used to survey the casing The first survey establishes the baseline profile of the installed casing Subsequent surveys will reveal changes in the profile if ground movement has occurred Plotting these changes reveals the rate depth and magnitude of ground movement The Digitilt AT system includes an inclinometer probe control cable a Bluetooth reel a cable gate the Digitilt Reader app for certified Android based tablet computer and DigiPro2 software that runs on Windows Digitilt AT gt emm a a H e e E E 5 Digitilt AT Inclinometer System 2014 6 04 Inclinometer Probe Measurement Axes Handling the Probe The Digitilt AT inclinometer probe is supplied in metric and English versions The metric version has a gauge length of 0 5m The English version has a gauge length of 2 feet A
16. igitilt AT Inclinometer System 2014 6 04 23 View Data This shows a table of data If your checksum plot shows a bad reading look at the data table to identify the depth and pass 0 or 180 of the bad reading If you are still on site you can reopen the survey and make the correction with the inclinometer probe The steps are 1 Tap and hold the depth the bad reading 2 Choose 0 or 180 3 The Reader displays that depth and a live reading Orient the probe for 0 or 180 insert it into the casing and lower it to the depth displayed on the Reader 4 Click OK to enable recording Tap the record button to record a replacement reading Continue upwards as needed or tap the Pause button to exit the survey Digitilt AT Inclinometer System 2014 6 04 24 Sending Data Files to a PC Introduction Inclinometer data files have a dux extension For convenience we call them dux Digitilt Uniform eXchange files You can send dux files to the PC by email or Dropbox Or you can transfer files by USB cable and a Windows file manager Email or Dropbox Send by Email Email transfers require an internet connection and an email program The instructions below assume you have a Gmail account since that is usual with Android devices Set Email Recipients 1 Setup is a one time task Tap Options Share oi Reader Options User Survey Mode NIT Battery Probe Share About Theme
17. ish the day s final survey Do not store wet cloth with the probe Allow the connector to dry thoroughly remove connector cap and allow connector to air dry for a number of hours Lubricate the wheels This helps displace moisture Lubricate the wheels by applying drops of a light machine oil on the wheel bearings Do not use WD 40 or any other lubricant spray that contains chlorinated solvents Wheels should be lubricated at the end of each day of usage prior to storage of the probe Lubricate regularly with O ring lube or silicone based grease Do not use WD 40 or any other lubricant spray that contains chlorinated solvents Digitilt AT Inclinometer System 2014 6 04 33 Connectors connector systems only Storage all systems Control Cable Inspection Cable all systems Connector key connector systems only Connector rubber insert connector systems only Connector for Probe connector systems only Clean connectors as necessary Use a slim cotton swab moist ened with alcohol Be careful not to bend pins Do not use electrical contact cleaners especially sprays Solvents in these products will attack the neoprene inside the connectors When attacked the neoprene swells and reduces the effective ness of the O ring seal Store probe in dry place Be sure that the box is dry the wheels are oiled the connector is dry Twists Twists indicate poor coiling technique Change practice do not pul
18. itched off automatically if there is no bluetooth con nection for 5 minutes or if there is no communication between reader and probe for 10 minutes The power switch can also be used to reset the reel if necessary Check that the charge cable is disconnected then press and hold the power switch for about 10 seconds The Battery LED blinks once after the reset The Bluetooth LED blinks while the Bluetooth radio waits for a connection Blinking is rapid at first and then slows When a connection is made the bluetooth LED glows a steady blue The Battery LED stays off during normal use A fully charged battery provides about 40 hours of operation If the battery charge is too low for operation the Battery LED and Power LED blink rapidly for a few seconds and then turn off Charge the battery as soon as possible Digitilt AT Inclinometer System 2014 6 04 Charging the Battery Reader DigiPro2 Software Plug the AC adaptor into a wall socket Insert the barrel plug into the charge socket on the back side of the reel The Battery LED first blinks and then changes to a steady red glow when the battery is charging When charging is finished the green Power LED blinks slowly You can charge the battery every night A charging circuit inside the reel limits charge time to 5 hours If the battery is fully discharged a full recharge may take longer than 5 hours In that case it is possible to reset the charge timer by discon
19. l the cable over the side of the reel reel off and reel on Worn markings user is dragging cable through cable gate Change practice pull cable out then up Kinks and or gouges if kinks do not straighten there is proba bly internal damage and likelihood of intermittent reading fail ures If any deep gouges water can enter cable In both cases bad section of cable must be removed either by shortening the cable or replacing the cable Wear Change connection practice use witness marks Corrosion Remove corrosion and change practice allow con nector to dry after use Swelling poor seal Rubber swells when attacked by WD 40 or contact cleaners Swelling may prevent good seal and allow water to enter connector Return for service if sealing is compro mised Check O ring Do not disassemble this connector Requires about two hours and a pressure test to reassemble Digitilt AT Inclinometer System 2014 6 04 34 Control Cable Maintenance Moisture Management all systems Cable all systems Connectors connector systems only Wipe off the control cable as you draw the probe up on the last run of the day When you return to the office remove connector caps and allow connectors to air dry for a number of hours When necessary rinse cable but not connectors in clean water or wash the cable in a laboratory grade detergent such as Liqui nox Do not use solvents to clean the cable Do not subm
20. mark with each recorded reading Ifa survey is interrupted the bookmark lets you resume from the last recorded depth 1 Display the inclinometer list 2 Tap the inclinometer to start a survey A dialog appears 3 Tap OK to start the survey from the bookmark To abandon the bookmarked survey and start a new survey choose New Start Survey kmark Use Bookmar Ss New 1 Tap Pause to halt the survey for any reason be NI el Dan Reader Pause 2 Make a choice then tap OK Or tap Cancel to resume the survey Pause Survey Abandon Bookmark Done Abandon Deletes the current survey Bookmark Sets a bookmark at the last recorded reading Done Saves the current survey as is This is useful if you are correcting a few readings and then want to stop Digitilt AT Inclinometer System 2014 6 04 17 Set Up 1 4 The Reader displays the start depth for Tap Survey Tap an inclinometer to survey SE Survey Run Througn Switch on Reel and Reader Tap the Digitilt Reader icon to start the app Wait for a steady blue glow from the Bluetooth LED to show that a connection has been made Gs Digitilt Reader Digitilt Reader oo m E Scan Survey You can switch between Tap mode and Hands free mode at any time The examples here show Tap mode ej el Plot Send dk LZal JI DURHAM GEO SLOPE IND
21. necting and then reconnecting the AC adaptor The adaptor provides 12 Vdc Polarity of barrel connector is inside and outside The Reader readout device is an Android tablet running the Digitilt Reader app Android Tablet Not all Android devices can run the Reader app A list of certified devices can be found on the Digitilt AT page on the Slope Indicator website Battery life varies with the device We recommend that you charge the device every night A typical survey requires 30 to 60 minutes If you have a demanding survey schedule an accessory battery pack or a sec ond battery may be useful Digitilt Reader App The Reader app is software that transforms the Android device into a full featured inclinometer readout The Reader app is available from Play Google Instructions are provided later DigiPro2 is a Windows program that creates a database to hold inclinometer surveys and generate plots for data analysis and printing To download DigiPro2 and the DigiPro2 manual 1 Direct your browser to www slopeindicator com 2 Click Downloads Software 3 Download both the software and the manual 4 Run the setup program for DigiPro2 Digitilt AT Inclinometer System 2014 6 04 About Pairing How to Pair Pairing Tablet amp Reel Pairing is normally a one time process During the pairing process the tablet and the reel exchange Bluetooth IDs and store them in memory Pairing essentially gives permission to
22. nometer System DEVELOPER Version 2012 10 02 Visit webpage Updated on Oct 29 2012 4 Tap Accept amp download after reviewing permissions 5 The Digitilt Reader icon appears on the tablet home screen 7 If the icon does not appear find the icon in the Digitilt Reader app drawer Then tap and hold the icon releasing it on one of the home screens Digitilt AT Inclinometer System 2014 6 04 9 Reader App Overview Digitilt Reader App Tap the Digitilt Reader icon to open the app Distt Reader Action Bar See below Drot Reader Survey Tap to start a survey from the inclinometer list Scan Tap to start a survey from a QR code Send Tap to send new surveys by email or Dropbox Plot Tap to show plots and data 1 D LJV Ji DURHAM GEO SLOPE INDICATOR System Bar Back Home Recent Action Bar Tap icon to take action Icons vary with screen ei Digitilt Reader i Options 4 Digitilt Reader Ka _ Add inclinometer aa ot Reader Ka Seen Done Cancel N Ss Digitilt Reader Ou Pa use s u rvey Digitilt AT Inclinometer System 2014 6 04 10 Adding an Inclinometer The Inclinometer List The Reader keeps a list of inclinometers along with the survey data for each inclinometer To see the list tap the Survey icon e To add an inclinometer to the list tap e To
23. o 5 dux __ 8 5 KB modified 13 seconds ago Digitilt AT Inclinometer System 2014 6 04 28 USB Transfers This method requires the USB cable supplied with your Reader device and the Windows file manager Windows Explorer Use the USB cable supplied with the Android device 1 Connect the Reader to the PC using the USB cable Choose Open device 2 The Reader device appears in the address line Click on Internal storage 3 Click on the Download folder Then click on the Digitilt Reader folder Portable Device x a Windows can perform the same action each time you What do you want Windows to do Open device to view files using Windows Explorer gt Sync digital media files to this device using Windows Media Player OE Treno actor TI Always perform the selected action L el e SR My Computer Transformer Prime TF201 File Edit View Favorites Tools Help Om O A Dee Ere Address i My Computer Transformer Prime TF201 Internal storage Generic hierarchical My Computer Transformer Prime TF201 Internal storage File Edit View Favorites Tools Help ES Digitilt Reader Documents K File Folder ownload File Folder Digitilt AT Inclinometer System 2014 6 04 29 USB Transfers Continued 4 Click on the Outbox fia My Computer Transformer Prime TF201 Internal storage
24. or the User ID then create a Dropbox password User ID and password are used again in the next steps 2 Download Dropbox for Windows Run the setup program and then log in to Dropbox using your User ID and pass word Now your PC is linked to Dropbox in the cloud 3 If you are using DigiPro2 create a default import folder in Dropbox See the DigiPro2 manual Otherwise just create a folder in Dropbox to hold the dux files 4 Visit the Google Play store using your Android device Search for Dropbox and install it You already have a Dropbox account so login using your User ID and password Now the Android device is linked to Dropbox too 5 The Dropbox file listing on your Android device now shows the folder you created in step 3 That is where the Reader app will send dux files Digitilt AT Inclinometer System 2014 6 04 27 Sending by Dropbox 1 Tap Send 2 Tap Share e Digitilt Reader Send Files Empty Outbox 3 Tap Dropbox Send E Mail 4 Tap Upload The Choose upload location Reader uploads the EE dux files to the T hetae specified folder Cancel Upload 5 Soon afterwards the files appear in the Dropbox folder rr on your PC We B modified 17 seconds ago Mukilteo 2 dux 7 1 KB modified 16 se Mukilteo 3 dux 7 1 KB mod Look in Arie med cn Mukilteo 4 dux My Documents 7 1 KB modified 14 seconds ago e Mukilte
25. rated for temperatures from 20 to 70 C 4 to 158 F Avoid using the probe in temperatures outside this range Control cable is used to control the depth of the inclinometer probe It also conducts power and readings between probe and reel The cable gate is pushed onto the top of the inclinometer cas ing to serve as the reference for the depth graduations During the survey successive cable graduations are locked into the cable gate to hold the Metric control cables have half meter graduations with labels every meter The first graduation is 0 5 meters from the top wheels of the probe English control cables two foot graduations with labels every four feet The first graduation is 2 feet from the top wheels of the probe probe steady for readings The cable gate fits three diameters of casing 85 70 and 48 mm 3 34 2 75 and 1 9 inch Digitilt AT Inclinometer System 2014 6 04 Bluetooth Reel Front Panel LEDs Bluetooth LED Power Switch amp Power LED Bluetooth LED Battery LED The Bluetooth reel transmits commands and readings between the Reader and the probe A battery pack inside the reel powers both the reel and the probe The front panel has three LED lamps and a power switch Digitilt AT Battery LED Power Switch SLOPE INDICATOR Made in USA Press to switch on Press again to switch off The Power LED glows green when power is on Power is sw
26. s 2 Enter one or more email addresses Then tap Done Visit Reader x Va Done Send Files Email Addresses Email name company com ___ _ Enter up to four Email addresses Email Email Digitilt AT Inclinometer System 2014 6 04 25 Sending by Email 1 Tap Send 2 Tap Share oe Reader Send Files Empty Outbox 3 Tap Gmail Send E Mail 4 Tap Send ae Tap Send l slope dev gmail com The Reader SS S attaches dux files niena m automatically nterne 7 Mukilteo 2 dux Ka Mukilteo 3 dux x Mukilteo 4 dux Ka Mukilteo 5 dux x 5 When the email arrives the recipient saves the attached files into a folder on the PC If you are using DigPro2 paste the files into your default import folder Digitilt AT Inclinometer System 2014 6 04 26 Send by Dropbox Set Up Dropbox Dropbox is a cloud service Dropbox transfers are more automated than email transfers No user actions are required The dux files sent from the Reader simply appear in the Drop box folder on your PC Dropbox Account Reader linked PC linked to Dropbox Ko Do e ole The convenience of Dropbox is well worth the time that it takes to set up Other cloud services such as Google Drive can be set up in a similar way 1 Visit Dropbox com using your web browser Create a free Dropbox account Enter an email address f
27. s and English units should be used with English probes Set default email addresses for sending data files by email Displays embedded serial number and firmware version Light theme shows black text on a light background Dark theme shows white text on a black background Choose theme that provides best visibility These settings can improve your surveys Stability This is the variation allowed for stable readings The default value is 6 sine units equivalent to 0 03mm or 001 inch The Digitilt DataMate which is the defacto standard uses a stability threshold that is two times larger If your readings take a long time to stabilize consider using a value up to 12 Digitilt AT Inclinometer System 2014 6 04 31 Exit Motion When a reading exceeds this number the reader app assumes the probe is in motion Used for hands free mode If the reader fails to detect your pulls try setting a lower number Users who pull slowly need a lower number Users who pull quickly can use a higher number Normal values are 80 to 100 If there is a lot of vibration at the site tap mode may be your only choice but you could try setting motion to a higher number and then make your pulls quick rather than slow The higher number decreases sensitivity to the ground vibration but you must accelerate the probe faster so that a pull can be detected Tap Lockout This tells the reader how long to display the saved message During
28. st of inclinometers Outbox This folder holds a copy of any dux file that has been updated with a new survey All the file transfer methods use files from the Outbox folder System Holds system files It contains the bookmark file which allows any interrupted survey to be restarted with no loss of data Most files are machine readable not human readable Digitilt AT Inclinometer System 2014 6 04 36 File Management FCC notice The final repository for your inclinometer data should be a database on your PC or network The dux files on the Reader should be regarded as temporary not long term Inclinometer Data This folder holds the original files As mentioned above the Reader scans the inclinometer folder to create its list of inclinometers e If you want two Readers to have the same list of inclinome ters copy the dux files from one Reader to the other e If you want to remove an inclinometer from the list delete its dux file in the Inclinometer data folder Outbox After you transfer the files from the Reader to the PC you can delete the files in the Outbox either with the Empty Outbox button on the Reader or via a file manager The Digitilt AT system reel contains a Bluetooth wireless mod ule FCC ID T9JRN41 1 The module label may be viewed by removing the Reel control panel Digitilt AT Inclinometer System 2014 6 04 37 FCC Statement Warning WARNING For Customers in CANAD
29. start a survey tap the inclinometer e To edit an inclinometer tap and hold the inclinometer oi Reader x aaa Tap to add Inclinometer List AlphaSite InclinO1 dux AlphaSite Inclin02 dux Tap to start survey AlphaSite Inclin03 dux BetaSite InclinO1 dux BetaSite Inclin02 dux BetaSite Inclin03 dux Tap and hold to edit DeltaSite Inclin 2 dux DeltaSite Inclin14 dux DeltaSite Inclin70 dux GammasSite Inclin01 dux KappaSite Inclin06 dux ZetaSite Inclin58 dux Digitilt AT Inclinometer System 2014 6 04 11 Adding an Inclinometer Fields on the inclinometer form Note 1 Tap Survey to display the list of inclinometers 2 Tap Add to display an inclinometer form ou Reader Ka 3 Make entries as explained below If the keyboard hides part of the form slide the form upwards with your finger eS Digitilt Reader Ka Vv Add Inclinometer Site Inclinometer Description AO Direction 0 Units metric Display Unit mm Depth Unit m Interval 0 5 Top Depth 0 5 Bottom Depth 4 Tap Done when the form is complete non Reader xX 1 wi Site amp Inclinometer These two fields are used together to identify an inclinometer Each field can contain 12 characters Spaces punctuation and special characters are not allowed Description Optional AO direction Optional Compass heading 0 to 359 Units Tap to switch between metric and English units
30. ter System 2014 6 04 0 Pass continued Now the Reader displays the top depth Raise the probe to this depth and wait for a stable reading 7 Tap when the record button is green 8 Tap End 0 Pass This disables recording so you can handle the probe 9 Now the Reader displays the start depth for the 180 Pass Recording is still disabled Remove the probe rotate it 180 degrees and insert it with the mark facing the A180 groove Lower it to the start depth eo D 0 5 1 0 A 5 33 B 4 25 ooe D 0 5 1 0 A 5 30 B 4 30 Digitilt AT Inclinometer System 2014 6 04 l w 3 gt D No 3 Run the 180 Pass 1 Tap Start 180 Pass This enables recording 2 Tap the record button when it is green You can see checksums now 3 The Reader displays the next active depth Raise probe to this depth and wait for a stable reading 4 Tap the record button when it is green 5 The Reader displays the next active depth Raise the probe to this depth wait for stable readings and then tap the record button Repeat these operations until the probe reaches the top depth 180 20 0 229 0 12 6 94 20122 Digitilt AT Inclinometer System 2014 6 04 21 180 Pass continued 6 Now the Reader displays the top depth Wait for a stable reading D 05 1 0 A 5 28 Sc 0 01 B 4
Download Pdf Manuals
Related Search
Related Contents
User Manual ResMed Oxygen Equipment Elisee 150 User's Manual Terminal User Guide iWL220/250G Pay@Taxi ENET-AP001A-EN-P 登録工場の社内検査記録を法定自主検査記録とされる場合の言語について Addenda to the Capture NX 2 User`s Manual En Picture Controls Sony CMD-J6 User's Manual Copyright © All rights reserved.