Home

Instructions

image

Contents

1. Back View Quick Release ES Button AF M 1 External Strobe Connector and Waterproof Cap Mode Dial Delete Playback Menu White Balance ISO Quality Optical Viewfinder O o N o oe a 10 11 2 13 14 15 16 17 18 Main Command Dial Live View Button Multi selector Up A Multi Selector Left lt q OK Button Multi Selector Right gt Multi Selector Down W Flash Compensation Dial 34 Info Quick Settings Initial Camera Setup Insert a fully charged battery Insert SD memory card 2GB or greater capacity recommended Set Time Zone and Date Set the Mode dial to M manual or A aperture priority Set shutter speed to 1 60th second or 1 125th second for fast moving subjects in M mode In A mode shutter speed is automatically locked at 1 60 second Set aperture to F8 for general photography or F22 for macro photography close ups Set red eye reduction and FP to OFF in the Menu Settings Set image resolution to highest jpeg setting or RAW Set ISO to 100 Set Metering to center weighted Opening the Housing Lid Snaps have a Lock To open push Lid Snap Lock forward and lift as shown Keep pressure on the Lid Snap so it does not fly open quickly Push Forward
2. Rotate the Dial to switch between TTL and Manual Modes TTL Mode compensation values are indicated in the yellow band Place the Setting Indicator to TTL for NO Compensation Rotate the Dial either direction to select compensation Place the Setting Indicator to the desired compensation value Note that in TTL compensation values are in 1 3 f stops Manual Mode compensation values are indicated in the black band Rotate the Dial to place the Setting Indicator to the desired compensation value Note that in Manual Mode compensation values are in 1 2 f stops from F full power to 3 f stops Set DS Substrobe to TTL mode This will allow the strobe power to be varied in manual mode 17 Mode and Compensation Dial TTL Flash Scale yellow 1 3 stops Setting Indicator Manual Flash Scale black 1 2 stops DS50 and DS125 Substrobe Compatibility Older DS50 Substrobes with Serial Number below 63 850 can NOT be updated to operate correctly with the latest TTL conversion circuitry Older DS50 Substrobes with Serial Number between 63 850 and 69 999 require upgrade of electronics to operate Cost of update depends on strobe circuitry Strobe must be returned to Ikelite for evaluation to provide an estimate of upgrade cost Older DS125 Substrobes with Serial Number below 2 500 can NOT be updated to operate correctly with the latest TTL conversion circuitry Older DS125 SubStrobes with Serial Number between 2 500 and 4 999 require
3. could vibrate loose during travel Keep the back and port o ring clean and lightly lubricated To lubricate remove the o ring from the back Put a small amount of Ikelite lubricant on your fingers Pull the o ring through your fingers to apply a light coating of lubricant Only apply enough lubricant to make the o ring feel slick Do Not stretch the o ring This light coating of lubricant will help to keep the o ring from drying out and will help to show a dark sealing line when the housing back is properly sealed Keep the area where the o ring fits and the sealing surface clean Rinse the housing exterior thoroughly in freshwater after each saltwater use Depress push buttons several times during rinse Dry with a soft cloth Dry port to eliminate water spotting After several uses in saltwater soak the housing in a mild soap solution rinse and dry Although not recommended if it is necessary to remove a housing push button Do Not re use the E clip Contact Ikelite for replacement E clips part 0319 12 CAUTION Never use spray lubricants as the propellant ingredient can cause the plastic housing to crack Use only Ikelite lubricant 25 Photo Tips 26 The number one rule in underwater photography is to eliminate as much water between the camera and subject as possible Get as close as you can to the subject then use the zoom If you are using flash for still photos subjects beyond 6 feet 1 8m will not have much co
4. lenses Manual focusing is not recommended In some cases if you desire to manually focus a lens the zoom clamp must be moved onto the lens Manual Focus Ring and you must use the housing zoom control knob to manually focus This will result in loss of zoom capability Figure G Mesh Gear Sleeve teeth with Black Housing Drive Gear 14 Installing the Port LD re fe OC There are four port locks on the an E Release utton front of the housing see figure G page 14 Each port lock has a Release Button Lift the Locked Position release button and slide each Lift Release Port Lock away from the port Ze Button to ee Unlock opening In the unlocked position the Release Button will remain in the up position as Pull Back to shown 2 Disengage Port To prepare the port for installation remove the port o ring and lightly lubricate it The port seal is a side to side seal and requires the o ring to be lightly lubricated for easy installation Put a small amount of lubricant on your fingers and pull the o ring through your fingers to lightly lubricate it Do not stretch the o ring Check that the lip of the port where the o ring fits and the sealing surface on the housing are clean Place the port with o ring into the housing port opening Press down on the port firmly and evenly until you feel the port slide into place Continue to push down on the port and push each port lock forward until the lock f
5. the empty housing completely in water before installing a camera If any fogging occurs or droplets of water enter the housing do not install a camera Clean the housing main o ring and retest to make sure that it is watertight Refer to the Troubleshooting section page 20 We suggest that you read this instruction booklet thoroughly before use to have a full understanding of where each camera control is located and what function each control provides Please read your camera manual thoroughly to have a full understanding of each camera function If you are new to underwater photography be sure to read the Photo Tips section Due to the power required to operate the camera and LCD screen start each dive with a fully charged camera battery Parts of the Housing Front View Quick Release On Off Strobe Arm AF Release Buttons Flash Mode Mount id Shutter AE L Release arp Zoom KI Drive Gear Port Sub command Opening Dial Lid mE Aluminum Tray Side View AF Release Buttons Lid Snap o Meter 4d Optional cr Lock Port AE L AF L 9 Shutter Release f Main Housing r O ring Sub command Dial Camera Tray 4 Gear al Sleeve c a aS Port O ring Leveling Screw Factory Pre set Camera Mounting do 4
6. upgrade of electronics to operate Cost of update depends on strobe circuitry Strobe must be returned to Ikelite for evaluation to provide an estimate of upgrade cost Using Non lIkelite or Ikelite Non DS Substrobes Substrobe 50 100A 200 400 with this Housing The Conversion Circuitry is automatically disabled when used with a Non lkelite or Non DS Substrobe These Substrobes can be used in their manual mode utilizing any power settings provided on the Substrobe 18 Pre Dive Your System It is recommended that you take the complete system into a swimming pool before use in open water This will give you a chance to become familiar with the handling and operation of your housing and strobe s As soon as you enter the water take a moment and check the housing to see that it is properly sealed Next check to see if there are any bubbles on the face of the port If there are take your fingers and remove them If there are bubbles on the lens port they can produce soft focus spots in your photographs Lubricants Ikelite provides silicone lubricant with the housing We recommend that you use only Ikelite lubricant Other brands may cause the o ring to swell and not seal properly Use only enough Ikelite lubricant to lightly cover control shafts and o rings Wipe off any excess lubricant with a clean cloth Lubricant is not a sealant and is used to reduce friction Excessive lubricant can collect sand and dirt which may interfere wit
7. P 10 Installing th POM renesse tinon inaina a P 15 Housing Conversion Circuitry cccceeeeceeeeteeeeeeteees P 17 DS50 and DS125 Substrobe Compatibility 0 P 18 Using Non lkelite or Ikelite Non DS Substrobes P 18 E E A P 19 Pre Dive your System ssssssessssrseserrerieserrnssrerrernsene P 19 LUDRICAINS scearon a siintsacind are meunen P 19 e E tae ad P 20 Replacement Parts 2 1511511111sistisirsitsi trte raent P 22 Recommended Accessories soca irinel P 22 Accessory Mounting Points EV Controller Use P 22 Ae et tana ta aaa P 23 PO TIDS sven eck tern A CE tans P 26 StOning the HOUSING ssnstinin P 27 Technical Support 00 0 0 eee eeeeeeneeeees P 27 Limited Warranty 0 0 0 eee e eee eee P 27 Returning Products for Service c ccceeeeeeeeeteeees P 28 2 Product Registration Please take a moment to fill out the online Ikelite Product Registration form at http www ikelite com forms regForm htm Package Contents _ SLR DC Housing Aluminum Tray amp Dual Handles Envelope containing tray Silicone Lubricant installation hardware Std Zoom Clamp amp Sleeve Set maintenance kit and extra 5509 28 Large Diameter Zoom control end tips Clamp amp Sleeve Set Preparation This product has been water pressure tested at the factory and is depth rated to 200 ft 60m Thoroughly inspect and immerse
8. Postage prepaid to Ikelite Underwater Systems Attention Service Department 50 West 33 Street Indianapolis IN 46208 USA No reimbursements for return freight will be issued Returning Products for Service outside the United States For the separate international customs documentation form that you complete to accompany the shipment please state or designate that the enclosed products were originally manufactured in the USA and are being returned to the manufacturer for repair service Value of the equipment listed for customs purposes should be zero Ikelite Underwater Systems 50 West 33rd Street Indianapolis IN 46208 USA 28 6809 1_Nikon_D90_02 1011
9. SLR DC Housing instruction manual ik li ine ite 6809 1 Nikon D90 Thank you for your purchase of Ikelite equipment Please read this instruction manual completely before attempting to operate or dive with this product 10 in 250mm including controls vite 13 7 in 348mm with Tray and Handles sates 7 0 in 178mm including controls ere 7 4 in 188mm with Tray and Handles weds 6 5 in 165mm including controls Weight 5 5 Ib 2595g housing only ET 7 3 Ib 3311g housing with tray amp handles Buoyancy Neutral to slightly negative in freshwater dependent on choice of lens and lens port Table of Contents Product Registration c ccccceeseeeeeeeeeeeeeeeeeseneeeeeeeeees Pe Package Contents 00 0 cece eee eeee een eenees P 3 ee S P 3 Parts 08 the HOUSING secst2hs ure asio chi cueltebe ees a P 4 Initial C amefa SetUpirsrsassnennordrarnsanoi nsa P 6 Opening the HOUSING ecinsnsniupesias anisa P 6 Setting the Conversion Circuitry Strobe ID Switch P 7 Attaching Camera to Camera Tray P 7 Attaching the Flash Connection for External Strobes P 8 Installing Camera in HOUSING ccceeeeeeeeeteeeteeteeees P 8 Closing the HOUSING issiria kabel ees P 9 Installing Zoom Clamp and Gear Sleeve 0
10. alling the Zoom Clamp amp Gear Sleeve On Type 2 Lenses Due to the larger diameter lens opening on Type 2 lenses the Zoom Clamp and Gear Sleeve need to be installed from the rear bayonet end of the lens Use the housing Lens Release Control and remove the camera lens from the camera body after the camera and lens have been installed in the housing Place the Gear Sleeve in the housing opening as shown Install the black Zoom Clamp on the Lens Zoom Ring and lower the lens into the housing opening Make sure the Zoom Clamp grooved tabs align with the Gear Sleeve ribs If necessary install rubber strips to expand the Zoom Clamp so it meshes properly with the Gear Sleeve Bayonet lens into camera body and align Gear Sleeve teeth with Black Housing Gear Teeth Type 2 lens E Lens Zoom Ring Lens Manual Focus Ring Zoom Clamp Align Zoom Clamp grooved tabs with Gear Sleeve Ribs Gear Sleeve TOP OF HOUSING 13 Installing Zoom Clamp Sleeve on Type 2 Lenses cont Before installing the lens port and checking operation make sure the teeth on the Gear Sleeve mesh with the teeth on the housing Drive Gear shown below When the port is installed pages 15 amp 16 it will lock the Gear Sleeve in place After installing the port rotate the housing Zoom Control Knob to see that the Gear Sleeve is properly rotating the Lens Zoom ring Manual Focusing Note Ikelite DSLR housings are designed for auto focus DSLR cameras and
11. h proper sealing Note Lubricant is not needed on the main housing o ring to maintain a housing seal however lightly lubricating this o ring can extend it s life and aid in seeing a good housing seal Too much lube can attract debris increasing the potential for a leak CAUTION Never use spray lubricants as the propellant ingredient can cause the plastic housing to crack Use ONLY Ikelite lubricant 19 Troubleshooting Problem Solution Push buttons or Remove the camera and rinse the closed housing controls are sticky in fresh water Vigorously press each push button and hard to operate in and out several times to release any trapped saltwater or debris Press a sticky push button all the way in and place a small amount of lube on the small end of the push button shaft at it s base Release and operate the push button several times to distribute the lube If a control is sticky grab the control knob pull it out and then push back in If still sticky see the Control Maintenance section pages 23 amp 24 Return housing to Ikelite for routine maintenance Image is over or Check that the strobe s are firing when taking under exposed a picture When using an external strobe make sure it is turned on set properly and it s battery is charged Check any corded connection points Adjust camera shutter speed aperture or exposure compensation Move closer to or further away from the subject Wa
12. id Snap Lock Lid Snaps have a lot of spring tension once they go over center so havea Lift firm grip on the Lid Snap Lid Snaps may be opened one at a time Setting the Conversion Circuitry Strobe ID Switch On the inside of the housing back is a switch DS DS for setting the DS Substrobe ID Set the switch to the Model of DS Substrobe being Vie m ey used 160 161 80 200 When using dual strobes of different models age TIL Moda such as a DS51 and a DS161 set the ID switch to DS51 or the smaller strobe Attaching Camera to the Camera Tray Remove the back from the housing The mounting tray for the camera is secured to the housing back Position the camera and lens on the camera tray and then secure it with the mounting bolt which threads into the camera s tripod fm socket Use a flathead screwdriver recommended or coin to tighten the mounting bolt so the camera bottom is flush against the tray Mounting Bolt Camera Tray Attaching the Flash Connection for External Strobes When using an external strobe connect the housing hotshoe connector Slide the connector into the hotshoe mount on the camera from the back of the camera as shown Slide the connector forward until it stops Due to limited clearance between the External Strobe Connector and Waterproof Cap camera hotshoe mount and the housing back the hotshoe connector should be attached before the camera i
13. ing surfaces of the housing Pictures are too blue or too green Use custom manual white balance if available Add an external strobe Move in closer to your subject when taking a picture Replacement Parts _ 0132 59 Spare Main Housing O ring 0105 Spare Port to Housing O ring 5020 Silicone Lubricant in 4 1cc Tubes 5512 68 O ring Kit with Main O ring Port O ring amp 1 cc Lubricant 0333 6 Tray Mounting Screw 12 24 x 1 2 in Stainless 0212 12 1 4 in Shoulder Washer for 12 24 Screw 9104 5 Waterproof Bulkhead Cap 0200 91 Body Cap d Recommended Accessories Accessory Mounting Points The top of the SLR DC housing features a 1 4 20 threaded mounting point for the attachment of a focus light video light or other lightweight accessories DO NOT attach heavy items to this mount and always use the correct length screw to attach a component The bottom of the SLR DC housing tray also features five 1 4 20 threaded mounting points for attachment of a tripod or other accessories A full range of accessories is available to support your housing Please visit http www ikelite com web_two nik_d90 html to see the most current information about recommended accessories Please Read If Using an EV Controller TTL flash control is not available when using an EV Controller and therefore an EV Controller is not recommended for use with this housing Note The EV Controller cannot be used as a slave If hard
14. lor regardless of strobe power Photograph in clear water do not stir up the sand or silty bottom If backscatter becomes a problem in the environment you are photographing an external flash will help eliminate much of the backscatter Many digital cameras have a slight lag time between when you press the shutter release button and the camera actually takes the picture Hold the camera steady a second or two after pressing the shutter release button Do not shoot down on subjects as they will quite often blend into the background and be difficult to see in the photograph Shoot subjects straight on or shoot up at a slight angle using the blue water as a contrasting background When using daylight or flash if your camera consistently over or underexposes the image you may want to adjust your camera s exposure compensation settings If you err in exposure it is better to have the image slightly underexposed rather than overexposed An overexposed image is missing color information which cannot be adjusted in a photo processing program A slightly underexposed image has color information that can be adjusted It is important to respect all living creatures underwater including people marine life and coral While we encourage people to get close to their subjects when taking a photograph they should not touch lie on or in any way disturb the things they find underwater Storing the Housing When the housing is going to be stored f
15. lt or dirt build up on the exposed control shaft clean the shaft Open the housing and gently slide the control shaft out of the control gland Clean and lightly lubricate the shaft including the end of the shaft Slide the shaft back into the control gland and gently slide it back and forth a few times without fully removing the shaft from the gland Replace the knob noting the flat area on the shaft The set screw in the knob should tighten down against the flat area on the control so the knob does not turn on the shaft 23 Diagram A Housing Gland Control Shaft Tighten set screw down against this flat area Lubricate end of shaft Loosen set screw when replacing the knob before reinserting into allen wrench required gland Diagram B Lubricate Shaft Housing Pull out to expose shaft 24 Housing Maintenance Your Ikelite Housing should be given the same care and attention as your other photographic equipment In addition to normal maintenance we recommend your housing be returned to Ikelite every 2 3 years or 50 dives to be checked and pressure tested Do Not leave the camera and housing in direct sunlight for prolonged periods Heat may damage the camera Do Not ship the camera in the housing Before using the housing always check the tightness of the set screw in each control knob Check each control gland penetrating the housing to make sure they are tight There is a slight chance that either
16. m clamp large diameter zoom clamp 9059 8 9059 9 Figure A Figure B 10 Installing the Zoom Clamp amp Gear Sleeve On the Type 1 Lenses The Zoom Clamp has springs so it can be expanded to fit over the Zoom Ring of the lens figure C page 11 Install the Zoom Clamp with the extension tabs toward the rear element of the lens After installing the Zoom Clamp and Gear Sleeve figures D amp E page 12 install the Lens Port and rotate the Zoom Ring on the lens If the Zoom Ring and Gear Sleeve do not mesh properly install the rubber strips supplied to the inside diameter of the Zoom Clamp as shown in figure F page 12 Two thicknesses of rubber strips are provided Start by installing the thinnest rubber strips If the Zoom Clamp still is not tight enough and meshes improperly with the Gear Sleeve use the thicker rubber strips Reinstall the Zoom Clamp Sleeve Mesh Gear Sleeve teeth with Black Housing Drive Gear figure G page 14 and then install the Lens Port After installing the port pages 15 amp 16 rotate the housing Zoom Control Knob to see that the Gear Sleeve is properly rotating the lens Zoom ring Type 1 lens mounted to camera Figure C 11 Type 1 Lenses cont Gear Sleeve Ribs Align Ribs with Zoom Clamp grooved tabs F apply rubber strips to inside of A i j me E Figure E Figure F 12 Inst
17. ntering the water Ikelite DSLR housings DO NOT come with a lens port You must select the correct port for each lens you will be using underwater For complete lens port information and compatibility with your Ikelite system go to http www ikelite com web_pages sIrport html Housing Conversion Circuitry This housing has Conversion Circuitry built into the housing When used with Ikelite DS Substrobes the Conversion Circuitry provides real Nikon iTTL flash exposure with over and under exposure compensation from 1 1 3 to 1 1 3 f stops in 1 3 stop increments The Conversion Circuitry also offers Manual exposure control with 3 1 2 f stops of under exposure control in 1 2 stop increments The Conversion Circuitry is powered by the Ikelite DS Substrobe when connected to the housing with the 4103 51 single or 4103 52 dual sync cord When using two strobes with the dual sync cord the primary strobe connected to the cord without the red band must be turned on to power the Conversion Circuitry Always keep both strobes connected to your dual sync cord underwater Do not exchange your secondary strobe for a dust cap which may not be waterproof See page 18 for DS50 and DS125 Substrobe compatibility with the Conversion Circuitry Using the Conversion Circuitry Set Ds Substrobe to TTL mode Mode and Compensation Dial Note that the TTL compensation values are located in the yellow band Manual compensation values are located in the black band
18. or a prolonged period it should be soaked in a mild soap solution rinsed and dried thoroughly Remove the back and port from the housing Remove the back and port o rings lightly lubricate them and place them in a plastic ziploc bag Place the plastic bag inside the housing for storage Operate the push buttons periodically Technical Support Email ikelite ikelite com Phone 317 923 4523 Fax 317 924 7988 Limited Warranty This Ikelite product is warranted against any manufacturing defects for a period of one year from the original date of purchase Defective products should be returned prepaid to Ikelite Ikelite will at its discretion repair or replace such products and will return to customer prepaid All other claims of any nature are not covered Except as mentioned above no other warranty expressed or implied applies to this Ikelite product 27 Returning Products for Service Ikelite is most interested in performing any service to ensure that all products perform as intended Evidence of purchase date must be provided to obtain warranty service No prior authorization is required You may return directly to Ikelite or through your dealer Please include a brief description of the problem any relevant e mail correspondence and or instructions on requested service Always include name shipping address email address and phone number inside of the package You may also want to insure the package Send
19. s secured with the mounting bolt Housing Back Hotsh O Wo deel l OnO Caution Do not remove the External Strobe Connector s waterproof cap unless an external sync cord is going to be plugged in Do not remove waterproof cap or sync cord underwater Installing Camera in Housing Before installing the camera pull out on the controls in the front section of the housing This will allow the camera to slide in easier Once the camera is installed and the lid snaps have been closed return the controls to their operating position Closing the Housing 1 2 housing back Place housing face down in your lap Check to see that there is an o ring on the housing back that is clean and in its proper location Guide the back onto the housing The o ring should touch the housing all the way around There should y o ring be an even gap all the way around between the housing and the housing housing back Lift the lid snaps so they are extended and place the lid snap into the corresponding hook on the housing back housing back To close the housing push down on the lid snaps until they snap into place Lid snaps on opposite sides of even gap the housing should be closed allg sides j YO at the same time Be sure they are down far enough to engage the lid snap lock housing Double check Once the housing is closed check the o ring seal Check the gap bet
20. ter enters the Remove clean and properly lubricate the main housing housing and port o rings Look for hairs dirt or foreign debris crossing the o ring seal Reassemble the housing without a camera installed and pressure test or take diving Return housing to Ikelite for routine maintenance Problem Camera does not take a picture Solution Install a fully charged battery A housing control is engaging a camera function and will not allow the shutter to fire There is not enough available light for the camera to properly focus Add a focusing light or strobe with a built in focusing light to your system Select a center focus point in your camera menu Housing is hard to close Make sure the camera is mounted properly on the camera tray and housing controls are out of the way Fogging occurs on the Lens Port Humid air is trapped inside the housing The camera produces heat and may condense any trapped moisture forming fog on the lens port Close the housing in an air conditioned room or vehicle or in front of an air conditioner The housing should not be in direct sunlight for an extended period of time Purchase desiccant packs from a local camera store and place one or two packs in your housing before each day of diving If moisture or water droplets are present around the controls or sealing areas return the housing to Ikelite for evaluation Clean the main housing o ring port o ring and seal
21. ully engages It may help to slightly rotate the port as you push in on the port lock Visually inspect each port lock and confirm that the Port Lock Release Button is seated flush against the Port Lock Body Do not rely on an audible click to indicate that the lock is engaged Check around the perimeter of the port seal to see that the o ring is properly sealed and not extruded figure 2 page 16 It is NOT necessary to tighten housing port locks after installing a port Port locks are factory adjusted Slight port movement is normal after port locks have been closed and port has been secured to the housing 15 Installing the Port cont To Remove Port Port Seal Inside View To remove the port lift up on each Release Button and slide the port lock away from the port If the port is installed before the camera is Fig 1 inserted into the housing look from the inside of the housing at the port seal Check to see that the o ring is properly seated as shown in figure 1 and not extruded as shown in figure 2 Fig 2 Caution After installing the port turn the Zoom Control knob on the housing If the Zoom Control is difficult to turn the gear sleeve may be warped If necessary reduce or omit any rubber installed on the Zoom Clamp figure F page 12 If the Zoom Clamp is still warped use of the 5509 28 package may be required see page 10 Lens Ports 16 A lens port must be secured to the housing before e
22. ween the housing back and the housing it should be even all the way around Look through the clear plastic back at the o ring You should see a darkened area where the o ring is compressed against the housing back If you do not see an even black compression seal all the way around the back open the lid snaps reseat the housing back and then close the lid snaps Visually check the seal again Preparing to Install Zoom Clamp amp Gear Sleeve Determine the type of lens being used on the camera Type 1 Lenses have a lens opening that is NOT larger in diameter than the i SS zoom ring Fig 1 Type 1 lens Type 2 lens Figure 1 Figure 2 Type 2 Lenses have a lens opening that IS larger in diameter than the zoom ring Fig 2 Zoom Clamps amp Gear Sleeves Included with Housing Normally used with Normally used with There are 2 different Type 1 lens Fig 1 Type 2 lens Fig 2 Zoom Clamps and 5509 28 Package 9059 8 small diameter clamp 9059 9 large diameter clamp Gear Sleeves For use with 0073 sleeve For use with 0073 1 sleeve provided with the M gi housing Start with P E a the suggested Zoom Clamp and Gear at yy H wide narrow Sleeve depending grooved ila on the Type of extension extension tabs lens being used n See Fig A or B T ma B or OE IA TA gu i 0073 sleeve Use with 0073 1 sleeve Use with small diameter zoo
23. wired to the housing set the EV Controller to Non pre flash 22 Maintenance Control Maintenance Ikelite controls are designed to provide years of reliable service with minimal maintenance Push button controls require no maintenance other than rinsing in fresh water after saltwater use If a push button control becomes difficult to push or if it sticks when depressed soak the housing in luke warm fresh water After a few minutes operate the push button If this does not correct the problem return the housing to Ikelite for maintenance Some of the controls have long shafts These controls can be pulled out exposing the shaft diagram B page 24 To lubricate the control gently pull on the knob until the stainless steel shaft is exposed Lightly lubricate the shaft then move the shaft in and out several times This will lubricate the x ring in the Ikelite control gland This should be done before using the housing after a prolonged storage period or once a week when the housing is in constant use Some of the controls have a short shaft and cannot be pulled out exposing the shaft for lubrication In the unlikely event one of these controls sticks or becomes difficult to operate you can remove the control from the housing and lubricate it or return the housing to Ikelite for maintenance To remove the control diagram A page 24 loosen the set screw in the knob allen wrench required remove the knob If there is sa

Download Pdf Manuals

image

Related Search

Instructions instructions synonym instructions not included movie instructions for 1040 2024 instructions in spanish translation instructions for form 8962 instructions brp instructions meaning instructions for 1040 instructions unclear meme instructions for form 941 instructions for schedule c instructions for form 720 instructions for form ss-4 instructions for 1040 2023 instructions for form 1040 instructions for submitting certain i-589 instructions in writing adr instructions synonyme instructions to candidates

Related Contents

  Betriebshandbuch zu Taurus  USER MANUAL  USETEL-ACISML  PDF版プラネタリウム・たぐちえつお作  User Manual KG 934  RapID NH System - Thermo Scientific  『てのりちゅっちゅ』7 月 12 日先 行行発売開始@銀座博品館  pag 5-2 09  

Copyright © All rights reserved.
Failed to retrieve file