CC-Link Safety System Remote I/O Module User`s Manual (Hardware)

image

Contents

1. nter 7 PART NAMES AND SETTINGS 4 1 Handling Precautions 4 2 Installation Environment 12 5 1 Precautions for Handling CC Link Dedicated Cables 5 2 Connecting CC Link Dedicated Cables 5 3 Precautions for Wiring Module Power Supply 14 5 4 Precautions for Wiring Safety Devices 5 5 Safety devices and wiring example T PRECAUTIONS FOR USE i cece t te ege perte 19 8 EC DECLARATION OF CONFORMITY FOR MACHINERY DIRECTIVE 20 A 14 ABOUT MANUAL The following manual is also related to this product In necessary order it by quoting the details in the table below Detailed Manual Manual name Manual No Model code CC Link Safety System Master Module User s Manual SH 080600ENG QS0J61BT12 13JR88 SH 080612ENG CC Link Safety System Remote I O Module User s Manual 13JR89 COMPLIANCE WITH THE EMC LOW VOLTAGE AND MACHINERY DIRECTIVES 1 Method of ensuring compliance To ensure that Mitsubishi programmable controllers maintain EMC Low Voltage and Machinery Directives when incorporated into other machinery or equipment certain measures may be necessary Please refer to the manual included with the base unit The CE mark on the side of the programmable controller indicates compliance with EMC Low Voltage and Machinery Directives Additional measures This product com
2. Description LED name Indication Indicates the power status of the safety remote I O module POWER ON green Normally powered OFF Powered off or error occurred blown fuse Indicates the operating status of the safety remote I O module ON green Normally operating or moderate error occurred Flashing at 500ms intervals green Switch setting has been registered but not fixed RUN yet or reading of error history data have been Indicator completed normally LEDs Flashing at 100ms intervals green Setting has been registered normally OFF Major error occurred Indicates the CC Link Safety system connection status of the safety remote 1 module ON green Connected to CC Link Safety system or self SAFETY loopback test completed normally Flash green Self loopback test in execution OFF Not connected to CC Link Safety system or self loopback test completed in error Description Indicates failure or error status of the safety remote I O module ON red Major error occurred or self loopback test completed in error RUN LED OFF Major error occurred Flashing at 500ms intervals red Moderate error occurred or reading of error history data have been completed abnormally Flashing at 100ms intervals red The registered switch setting differs from the actual switch setting OFF Normally operating L RUN
3. A hole used when installing a module directly to a panel 10 4 MOUNTING AND INSTALLATION 4 1 Handling Precautions This section provides handling precautions for use of the safety remote module 1 Do not drop the safety remote I O module or apply any strong impact to it 2 Do not remove the printed circuit board PCB of the safety remote module from the case Doing so may cause failure 3 Carefully prevent any dust or wiring chips from entering the safety remote I O module Failure to do so may cause a fire failure or malfunction 4 When installing the safety remote I O module to a control panel provide clearance of at least 60mm between the module s top bottom and any other structure or component to ensure proper airflow and to make module replacement easy 5 Install the safety remote I O module to a flat surface If it is not flat an excess force may be applied to the PCB causing failure 6 Tighten the module mounting screws and terminal screws within the following torque range Overtightening may result in damage to the screws or the module case Serrer les vis de fixation du module et les vis de borne dans les limites du couple de serrage prescrit Un serrage excessif peut endommager les vis ou le boitier du module Screw Specified torque range Module mounting screw M4 screw with plain washer finished round 0 824 to 1 110N m Terminal screw M3 screw 0 425 to 0 5
4. Double input output wiring Execution of the self diagnostic function dark test The following shows an example of wiring between the safety remote I O module and the safety device to meet the above points For details on the wiring with safety devices refer to the Safety Application Guide 1 Wiring example of the QSOJ65BTS2 8D a Wiring example with a safety switch 2 NC contacts and a safety sensor 1Insulation 24VDC rH oe avoc 24VDC 3 4 i 1 7248 F 1 s CC Link te 200v dedicated cable Ta 2 08 4 DG i 1 Sr rr A 4 0 EFS 1 qed 1 71 1 1 9 Internal circuit 1 XIA 1 EE Safety sensor etc 1 IN Control 2 1 output 1 9 l Control x3 1 TOVIN output 277 1 9 coma anne CC Link terminal 3 T DA DG r24V 24G 4 2 DB SLD FG Terminal block No Line C Line B Line A 1 Empty Empty Empty 2 TO KO 3 T1 x1 4 TO x2 5 T1 6 TO X4 COM 7 T1 X5 8 TO
5. Indicates the communication status of the safety remote module in the CC Link Safety system ON green Normally communicating in the CC Link Safety system OFF Communication failure in the CC Link Safety system Timeout error Indicator LEDs L ERR Indicates the communication error status of the safety remote I O module in the CC Link Safety system ON red Value set by link ID station No or transmission setting switch is out of range Flash regularly red Setting of link ID station No and or transmission setting switch is different from that of the internal nonvolatile memory Flash irregularly red Wrong terminating resistor setting or noise influence OFF Normally operating SD Indicates the sending status of the safety remote module in the CC Link Safety system ON green Data being sent RD Indicates the receiving status of the safety remote I O module in the CC Link Safety system ON green Data being received to XE Indicates the Input status of the safety remote I O module ON red Input ON OFF Input OFF Link ID setting switch Setting Description 0107 Link ID setting EL Setting for reading error logs LBT Setting for self loopback test To refresh the switch setting perform the reset operation or turn the power OFF ON of the safety remote I O module Description Set station No of the s
6. MITSUBISHI ELECTRIC Mitsubishi Safety Programmable Controller MELSEC QS NEN CC Link Safety System Remote Module User s Manual Hardware QS0J65BTS2 8D Thank you for purchasing the Mitsubishi safety programmable controller MELSEC QS series The MELSEC QS programmable controller is suitable for establishing safety functions for general industrial machinery Prior to use please read both this manual and detailed manual thoroughly and familiarize yourself with the product QS0J65BTS2 8D U HW MODELE 13JY66 CC Link Safety e memorie IB NA 0800414 G 1406 MEE 2008 MITSUBISHI ELECTRIC CORPORATION SAFETY PRECAUTIONS 6 Always read these instructions before using this equipment Before using the product please read this manual the relevant manuals introduced in this manual standard programmable controller manuals and the safety standards carefully and pay full attention to safety to handle the product correctly In this manual the safety instructions are ranked as AN WARNING and A CAUTION Indicates that incorrect handling may cause A WARNING hazardous conditions resulting in death or severe injury Indicates that incorrect handling may cause 1 1 I I A CAUTION hazardous conditions resulting in minor or moderate injury property damage Note that the Z CAUTION level may lead to a serious consequence
7. Soi Serithai 54 T Kannayao A Kannayao Bangkok 10230 Thailand Tel 66 2906 3238 P T Autoteknindo Sumber Makmur Muara Karang Selatan Block A Utara No 1 Kav No 11 Kawasan Industri Pergudangan Jakarta Utara 14440 P O Box 5045 Indonesia Tel 62 21 663 0833 Mitsubishi Electric India Pvt Ltd 2nd Floor Tower A amp B Cyber Greens DLF Cyber City DLF Phase lll Gurgaon 122002 Haryana India Tel 91 124 463 0300 Mitsubishi Electric Australia Pty Ltd 348 Victoria Road PO 11 Rydalmere N S W 2116 Australia Tel 61 2 9684 7777 MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 HIGASHI KU NAGOYA JAPAN ication to the Ministry issi of Economy Trade and Industry for service transaction peri Specifications subject to change without notice
8. Placing an object on the cable Scratching the cable sheath 5 2 Connecting CC Link Dedicated Cables The following figure shows how safety remote modules connected with CC Link dedicated cables Safety remote Safety remote Safety master module y module module Terminating 4 DA P P Fr i DA p Terminating resistor DB DB X DB resistor 1 YH DG Ft DG ccu NSF ccu SUD FG dedicated cable FG dedicated i FG English French English French Module ma tre de R sistance Safety master module s curit Terminating resistor d extr mit Safety remote I O Module E S de CC Link dedicated C ble d di pour CC module s curit distant cable Link Blue Bleu White Blanc Yellow Jaune 13 1 Connect the shielded wire of the CC Link dedicated cable to SLD terminal of each module and ground both ends to the protective ground connectors via FG terminals The SLD and FG terminals are connected inside the module 2 Always connect terminating resistors to the modules located on both ends of the data link network Connect a terminating resistor between DA and DB terminals 1 Raccorder le fil de blindage du cable d di CC Link a la borne SLD de chaque module et mettre les deux extr mit s a la masse sur les connecteurs de mise la terre via les borne FG Les bornes S
9. X6 9 T1 X7 10 TO X8 11 T1 X9 12 TO XA COM 13 T1 XB 14 TO XC l O24V 15 T1 XD 16 TO XE 1 024G 17 T1 XF QSOJ65BTS2 8D ggggoogggggogggg 17 6 EXTERNAL DIMENSIONS 48 Mounting pitch 188 4 2 4 5 0 18 mounting hole 7 42 M4 mounting screw 9 0 35 555255554555555 7 s e e 5 197 zi DIN rail center 7 76 Unit mm inch 18 7 PRECAUTIONS FOR USE Users must prove that their entire safety system complies with the safety standards and the Machinery Directive The third party certification organization will validate the safety of product for the entire safety system including a safety programmable controller and safety components To establish a safety system calculate the target failure measure PFD PFH for each safety application safety function based on the PFD PFH values of the safety programmable controller and connected safety components The target failure measure PFD PFH is the reliability target value for each Safety Integrity Level SIL defined in IEC61508 and can be ca
10. according to the circumstances Always follow the instructions of both levels because they are important to personal safety Please save this manual to make it accessible when required and always forward it to the end user A 1 Design Precautions AWA WARNING When a safety programmable controller detects an error in an external power supply or a failure in programmable controller main module it turns off all the outputs Create an external circuit to securely stop the power of hazard by turning off the outputs Incorrect configuration may result in an accident Create short current protection for a safety relay and a protection circuit such as a fuse and breaker outside a safety programmable controller If load current more than the rating or overcurrent due to a short circuit in the load has flowed in the CC Link Safety remote module the module defines it as a fault and turns off all the outputs However if overcurrent flows in the CC Link Safety remote module for a long time it may cause smoke or a fire To prevent it create a safety circuit Such as a fuse outside the module When a safety remote I O module has detected CC Link Safety error it turns off all the outputs Note that the outputs in a sequence program are not automatically turned off If CC Link Safety error has been detected create a sequence program that turns off the outputs in the program If the CC Link Safety is restored wit
11. liable for failure to do 50 b Products stored at the request of Customer because Customer refuses or delays shipment shall be at the risk and expense of Customer c MELCO shall not be liable for any damage to or loss of the Products or any delay in or failure to deliver service repair or replace the Products arising from shortage of raw materials failure of suppliers to make timely delivery labor difficulties of any kind earthquake fire windstorm flood theft criminal or terrorist acts war embargoes governmental acts or rulings loss or damage or delays in carriage acts of God vandals or any other circumstances reasonably beyond MELCO s control 5 Choice of Law Jurisdiction These terms and any agreement or contract between Customer and MELCO shall be governed by the laws of the State of New York without regard to conflicts of laws To the extent any action or dispute is not arbitrated the parties consent to the exclusive jurisdiction and venue of the federal and state courts located in the Southern District of the State of New York Any judgment there obtained may be enforced in any court of competent jurisdiction 6 Arbitration Any controversy or claim arising out of or relating to or in connection with the Products their sale or use or these terms shall be settled by arbitration conducted in accordance with the Center for Public Resources CPR Rules for Non Administered Arbitration of International Disputes by a
12. or one year from date of Customer s purchase whichever is less Mitsubishi MELSEC Safety programmable logic controllers the Products will be free from defects in material and workmanship b At MELCO s option for those Products MELCO determines are not as warranted MELCO shall either repair or replace them or issue a credit or return the purchase price paid for them c For this warranty to apply 1 Customer shall give MELCO i notice of a warranty claim to MELCO and the authorized dealer or distributor from whom the Products were purchased ii the notice shall describe in reasonable details the warranty problem iii the notice shall be provided promptly and in no event later than thirty 30 days after the Customer nows or has reason to believe that Products are not as warranted and iv in any event the notice must given within the warranty period 2 Customer shall cooperate with MELCO and MELCO s representatives in MELCO s investigation of the warranty claim including preserving evidence of the claim and its causes meaningfully responding to MELCO s questions and investigation of the problem grant MELCO access to witnesses personnel documents physical evidence and records concerning the warranty problem and allow MELCO to examine and test the Products in question offsite or at the premises where they are installed or used and 3 If MELCO requests Customer shall remove Products it claims are defective and ship hem to MEL
13. programmable il d sactive toutes les sorties Constituer un circuit externe coupant infaillilement l alimentation en cas de danger pour d sactiver les sorties Une configuration incorrecte peut tre l origine d un accident Pr voir l ext rieur de l automate programmable de s curit une protection contre les courants de court circuit pour les relais de s curit et un circuit de protection avec fusible ou disjoncteur Sile courant de charge exc de la valeur nominale ou si une surintensit due un court circuit la charge circule dans le module E S distant de s curit CC Link le module d tecte l anomalie et d sactive toutes les sorties Cependant une surintensit circulant pendant longtemps dans le module E S distant de s curit CC Link peut tre l origine d un d gagement de fum e ou d un d part de feu Pour viter cela pr voir un circuit de s curit ext rieur au module avec un fusible par exemple Quand le module E S distant de s curit d tecte une erreur de s curit CC Link il d sactive toutes les sorties On remarquera que dans un programme s quentiel les sorties ne sont pas toujours automatiquement d sactiv es Pr voir dans le programme s quentiel la d sactivation des sorties dans l ventualit une erreur de s curit CC Link serait d tect e Le r tablissement de la s curit CC Link alors que les sorties sont actives pourrait causer un brusque mouvement l origi
14. 25N m Vis de borne Vis M3 0 425 0 525 Nem 2 piece terminal block mounting screw M3 5 screw 0 680 to 0 920N m 11 7 When using a DIN pay attention to the following a Applicable DIN rail model conforming to IEC 60715 TH35 7 5Fe TH35 7 5Al b Installation screw intervals Tighten the screws at pitches of 200mm 7 88 inch or less 8 When installing the safety remote I O module to the DIN rail press the center part of the hook located on the bottom of the module until a click is heard Note Do not press the front face as shown below Doing so may cause failure Front face 9 If the mechanical power supply switch is used for the safety remote 1 O module in rare cases it does not operate when the excessive chattering is generated at power on and safety diagnostics function operates due to the unstable status of the input power supply voltage In this case turn on power supply again 4 2 Installation Environment For installation environment refer to 2 1 General Specifications 5 5 1 Precautions for Handling CC Link Dedicated Cables This section explains how to handle CC Link dedicated cables Do not perform any of the following as each of them will damage CC Link dedicated cables Compressing the cable with a sharp object Twisting the cable excessively Pulling the cable too hard exceeding the allowable tension Stepping on the cable
15. C Ripple ratio 596 or less 2 For module technical version C or earlier the number of input points is 8 points Two inputs terminals are assigned for each input since dual wiring is supported 3 Do not insert two or more wires into one terminal 8 Ne pas introduire deux fils ou plus de deux dans une m me borne 2 3 Cable Specifications Use CC Link dedicated cables for the CC Link Safety system The performance of the CC Link Safety system cannot be guaranteed when any other cables are used For the specifications or any other inquiries visit the following website CC Link Partner Association http www cc link org Remark For details refer to the CC Link Cable Wiring Manual issued by the CC Link Partner Association 2 4 Confirming Production Information The production information of the QSOJ65BTS2 8D can be confirmed on the rating plate located on the side of the module Safety EISE QS MITSUBISHI Model name MODEL QSOJ65BTS2 8D TECH VERIA Module technical version SERIAL000000000000000 A Production information pe i 1 Standard symbol for conformance is described MITSUBISHI ELECTRIC MADE IN JAPAN 2 5 Safety Standards Normes de s curit Use the product according to the following safety standards Region Safety Standards 1EC61508 Parts 1 7 1998 2000 1 5013849 1 2006 International 1EC61131 2 2007 IEC61000 6 2 2005
16. CO or MELCO s authorized representative for examination and if found defective for repair or replacement The costs of removal shipment to and from MELCO s designated examination point and reinstallation of repaired or replaced Products shall be at Customer s expense 4 If Customer requests and MELCO agrees to effect repairs onsite at any domestic or overseas location the Customer will pay for the costs of sending repair personnel and shipping parts MELCO is not responsible for any re commissioning maintenance or testing on site that involves repairs or replacing of the Products d Repairs of Products located outside of Japan are accepted by MELCO s local authorized service facility centers FA Centers Terms and conditions on which each FA Center offers repair services for Products that are out of warranty or not covered by MELCO s imited warranty may vary e Subject to availability of spare parts MELCO will offer Product repair services for 7 years after each Product model or line is discontinued at MELCO s or its FA Centers rates and charges and standard terms in effect at the time of repair MELCO usually produces and retains sufficient spare parts for repairs of its Products for a period of seven 7 years after production is discontinued f MELCO generally announces discontinuation of Products through MELCO s Technical Bulletins Products discontinued and repair parts for them may not be available after their production is discontin
17. IEC61000 6 4 2006 1EC61784 3 2010 IEC60204 1 2006 E EN954 1 1996 EN 1S013849 1 2008 EN61131 2 2007 61000 6 2 2005 61000 6 4 2007 01508 79 2007 Utiliser le produit dans le respect des normes de s curit suivantes R gion Normes de s curit 1 61508 Parts 1 7 1998 2000 15013849 1 2006 International 61131 2 2007 IEC61000 6 2 2005 61000 6 4 2006 1 61784 3 2010 60204 1 2006 954 1 1996 EN 15013849 1 2008 EN61131 2 2007 urope 61000 6 2 2005 EN61000 6 4 2007 Am rique du UL508 NFPA79 2007 Nord 2 6 Module Replacement Replace the module according to the following replacement cycle Replacement 0755 CC Link Safety system remote I O module 3 PART NAMES AND SETTINGS The name of each part in the QSOJ65BTS2 8D is shown 1 1 Y MITSUBISHI asovesars200 6 1105 10 DA Loc av 246 OPOWER GLRUN 5 sto are ORUN OLERR 8 oak OR meme DOOOC axe o a i5
18. LD et FG sont raccord es l int rieur du module 2 Toujours placer des r sistances d extr mit sur les modules plac s aux deux extr mit s de la liaison de donn es Raccorder une r sistance d extr mit entre les bornes DA et DB 5 3 Precautions for Wiring Module Power Supply When wiring the module power supply of the safety remote module note the following Cable length of the module power supply must be within 10m 32 81 ft 5 4 Precautions for Wiring Safety Devices This section describes the precautions for wiring to each safety device 1 Wiring of the input terminal section a Combinations of input terminals Input terminals can be used in the following combinations only Using them in any other combination will result in a moderate error X0 and X1 X2 and X3 X4 and X5 X6 and X7 X8 and X9 and XB XF t remote I O ms b Combinations of the test pulse output terminals Using the same test pulse for one device is not allowed If the same test pulse is used in combinations such as XO TO and X1 TO a moderate error will occur remote 1 0 15 5 5 Safety devices and wiring example This section describes the wiring between the safety remote I O module and safety devices To satisfy the wiring requirements specified in Category 4 the following two points must be executed in the safety remote I O module
19. VDC all points ON excluding external load current power Protection supply function External power supply overvoltage overcurrent protection function Fuse 8A Not replaceable Wiring method for common 16 input points per common Spring clamp terminal block 2 wire type Number of occupied stations 1 station Number of accesses to nonvolatile memory inside 1012 times module Safety refresh response 9 6ms processing time Voltage 19 2V to 28 8V DC Ripple ratio 5 or less Current 120mA or less 24V DC all points ON Module freuen Module power supply overvoltage overcurrent protection function power supply 1 Fuse 0 8A Not replaceable Momentary power failure 10ms or less period Noise immunity Tested by a DC type noise simulator with noise voltage of 500Vp p noise width of 1 5 and frequency of 25 to 60Hz Dielectric withstand voltage 500V AC between all external DC terminals and ground for 1 minute Insulation resistance DC input module QS0J65BTS2 8D 10M Q or more between all external DC terminals and ground by a 500VDC insulation resistance tester Level of protection IP2X Weight 0 46kg External connection system Syst me de connexion externe Communication section module power supply section Section communication section alimentation du module 7 two piece terminal block Transmission circuits module powe
20. afety remote I O module within a range Station No setting from 0 to 64 switch 4 Tens place of station No is set by X10 Units place of station No is set by X1 Setting Transmission speed 0 156kbps Transmission speed 1 625kbps setting Switch 4 2 2 5Mbps 3 5Mbps 4 10Mbps Always set this switch within a range of 0 to 4 Saves the values set by switches 2 to 4 into the nonvolatile Setting saving switch memory inside the safety remote I O module Reset switch 4 Resets the hardware of the safety remote module Two piece spring clamp terminal block for connection of external YO terminal block power supply and I O signals Power supply transmission terminal block Two piece terminal block for connection of module power supply and transmission signal Hook used for installing the module to a DIN rail Flook Tor DIN Tail Press the center part of the hook until a click is heard Mounting hole for screw installation 1 Although the RUN SAFETY and ERR LEDs momentarily turn on immediately after power ON or reset it does not mean any fault 2 The SAFETY LED is off when no safety remote station parameters have been received during connection to the CC Link Safety system 3 Duplicate station number setting is not allowed 4 For the switch setting methods refer to the CC Link Safety System Remote 1 Module User s Manual
21. d as a guide for Customer s use They do not constitute warranties and are not incorporated in the contract of sale for the Products h These terms and conditions constitute the entire agreement between Customer and MELCO with respect to warranties remedies and damages and supersede any other understandings whether written or oral between the parties Customer expressly acknowledges that any representations or statements made by MELCO or others concerning the Products outside these terms are not part of the basis of the bargain between the parties and are not factored into the pricing of the Products i THE WARRANTIES AND REMEDIES SET FORTH IN THESE TERMS ARE THE EXCLUSIVE AND ONLY WARRANTIES AND REMEDIES THAT APPLY TO THE PRODUCTS j MELCO DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE 24 3 Limits on Damages a MELCO S MAXIMUM CUMULATIVE LIABILITY BASED ON ANY CLAIMS FOR BREACH OF WARRANTY OR CONTRACT NEGLIGENCE STRICT TORT LIABILITY OR OTHER THEORIES OF RECOVERY REGARDING THE SALE REPAIR REPLACEMENT DELIVERY PERFORMANCE CONDITION SUITABILITY COMPLIANCE OR OTHER ASPECTS OF THE PRODUCTS OR THEIR SALE INSTALLATION OR USE SHALL BE LIMITED TO THE PRICE PAID FOR PRODUCTS NOT AS WARRANTED b Although MELCO has obtained the certification for Product s compliance to the international safety standards 61508 EN954 1 18013849 1 from Rheinland his fact does not guarante
22. e The user of this Product shall comply with any and all applicable safety standard regulation or law and take appropriate safety measures for the system in which the Product is installed or used and shall take the second or third safety measures other than the Product MELCO is not liable for damages that could have been prevented by compliance with any applicable safety standard regulation or law 2 MELCO prohibits the use of Products with or in any application involving and MELCO shall not be liable for a default a liability for defect warranty a quality assurance negligence or other tort and a product liability in these applications a power plants b trains railway systems airplanes airline operations other transportation systems c hospitals medical care dialysis and life support facilities or equipment d amusement equipments e incineration and fuel devices f handling of nuclear or hazardous materials or chemicals g mining and drilling h and other applications where the level of risk to human life health or property are elevated REVISIONS The manual number is given on the bottom right of the cover Print Date Manual Number Revision Apr 2008 IB NA 0800414 A First printing Jul 2009 IB NA 0800414 B Correction COMPLIANCE WITH THE EMC AND LOW VOLTAGE DIRECTIVES Section 2 2 2 3 2 4 Chapter 3 Section 4 1 4 2 Chapter 5 Jun 2010 0800414 Correctio
23. e that Product will be free from any malfunction or failure The user of this Product shall comply with any and all applicable safety standard regulation or law and take appropriate safety measures for the system in which the Product is installed or used and shall take the second or third safety measures other than the Product MELCO is not liable for damages that could have been prevented by compliance with any applicable safety standard regulation or law c MELCO prohibits the use of Products with or in any application involving power plants rains railway systems airplanes airline operations other transportation systems amusement equipments hospitals medical care dialysis and life support facilities or equipment incineration and fuel devices handling of nuclear or hazardous materials or chemicals mining and drilling and other applications where the level of risk to human life health or property are elevated d MELCO SHALL NOT BE LIABLE FOR SPECIAL INCIDENTAL CONSEQUENTIAL INDIRECT OR PUNITIVE DAMAGES FOR LOSS OF PROFITS SALES OR REVENUE FOR INCREASED LABOR OR OVERHEAD COSTS FOR DOWNTIME OR LOSS OF PRODUCTION FOR COST OVERRUNS OR FOR ENVIRONMENTAL OR POLLUTION DAMAGES OR CLEAN UP COSTS WHETHER THE LOSS IS BASED ON CLAIMS FOR BREACH OF CONTRACT OR WARRANTY VIOLATION OF STATUTE NEGLIGENCE OR OTHER TORT STRICT LIABILITY OR OTHERWISE e In the event that any damages which are asserted against MELCO arising out of or rela
24. ent ou effort de traction exerc accidentellement sur le c ble tout mauvais contact d un c ble pouvant tre l origine de dysfonctionnement Pour d brancher les c bles de communication ou d alimentation ne pas tirer sur le c ble proprement dit Retirer le c ble raccord au bornier apr s avoir desserr les vis de bornes Tirer sur un c ble raccord au module peut endommager le c ble ou le module et tre l origine de dysfonctionnements Pr cautions de d marrage et de maintenance A AVERTISSEMENT Ne pas toucher aux bornes quand l appareil est sous tension Cela pourrait tre l origine de chocs ou d un fonctionnement erratique Couper l alimentation externe utilis e par le syst me sur toutes phases avant de nettoyer le module ou de resserrer les vis de fixation du bornier les vis de bornes ou les vis de fixation du module Faute de quoi il y a risque de choc lectrique Serrer les vis de fixation du bornier les vis de borne et les vis de fixation du module dans les limites du couple de serrage prescrit Une vis de fixation de bornier ou un vis de borne mal serr e peut tre l origine d un court circuit d un d part de feu ou de dysfonctionnements Un serrage excessif peut endommager la vis et ou le module et une chute de vis ou de module risque d entra ner un court circuit ou des dysfonctionnements Un serrage insuffisant des vis de fixation de module peut tre l origine d une chute de
25. ge of the screw or module Do not directly touch the module s conductive parts or electronic components Touching the conductive parts could cause an operation failure or give damage to the module Wiring Precautions Completely turn off the externally supplied power used in the system when placing wiring Not completely turning off all power could result in electric shock or damage to the product When energizing or operating the module after installation or wiring be sure to close the attached terminal cover Not doing so may result in electric shock A 3 Wiring Precautions NCAUTION Be sure to ground the FG terminals and LG terminals to the protective ground conductor Not doing so could result in electric shock or erroneous operation When wiring in the programmable controller be sure that it is done correctly by checking the product s rated voltage and the terminal layout Connecting a power supply that is different from the rating or incorrectly wiring the product could result in fire or damage Tighten a terminal block mounting screw terminal screw and module mounting screw within the specified torque range If the terminal block mounting screw or terminal screw is too loose it may cause a short circuit fire or malfunctions If too tight it may damage the screw and or the module resulting in a drop of the screw or module a short circuit or malfunctions If the module mounting screw is too
26. h the outputs on it may suddenly operate and result in an accident To inhibit restart without manual operation after safety functions was performed and outputs were turned OFF create an interlock program which uses a reset button for restart NCAUTION Do not bunch the wires of external devices or communication cables together with the main circuit or power lines or install them close to each other They should be installed 100 mm 3 94 inch or more from each other Not doing so could result in noise that would cause malfunctions Select the external devices to be connected to the CC Link Safety remote module considering the maximum inrush current with reference to the CC Link Safety System Remote Module User s Manual A 2 Installation Precautions NCAUTION Use a safety programmable controller in the environment that meets the general specifications described in the QSCPU User s Manual Hardware Design Maintenance and Inspection Using this programmable controller in an environment outside the range of the general specifications could result in electric shock fire erroneous operation and damage to or deterioration of the product Make sure to fix the CC Link Safety remote module with a DIN rail or mounting screws and tighten the screws with the specified torque If the screws are too loose it may cause a drop of the screw or module Overtightening may cause a drop due to the dama
27. in Appendix These products comply with the following European directives Name 2008 42 Machinery Directive Further details of conformity to these directives are contained in the appendices 8 9999 0618 8 later Authorised Signature T Takahashi Senior Manager FA System Department Date signature fgaf2oe GA Authorised Representative Mitsubishi Electric Europe in the European Community Gothaer Str 8 40880 Ratingen Germany through Responsible person Signature P tz Executive Vice President amp Deputy Product Marketing Director FA European Business Group Date signafure O2 B Ramn The appendices are part of this declaration This declaration certifies the conformity with the directives mentioned but does not contain any warranted qualities The installation usage and safety directions of the product documentation have to be observed 9999 0617 20 QS0 Series Programmable Controllers Range of products QS001CPU 5 QS061P A1 K 5 050 65 2 120 5 QS001CPU K 5 QS061P A2 5 QS0J65BTS2 4T 5 050348 5 QS061P A2 K 5 QS0J65BTS2 8D 5 QS034B E 5 QS0J61BT12 5 QS0J71GF11 T2 5 QS034B K 5 QS0J61BT12 K 5 QS061P A1 5 QS0J65BTB2 12DT 5 The conformity of the above mentioned products with the regulations of the directive 2006 42 EC for machinery is shown by the application of a Technical Construc
28. ique ou peut endommager ou d t riorer le produit est indispensable de fixer le module E S distant de s curit CC Link sur rail DIN pour par des vis de fixation serr es au couple prescrit Si le serrage est insuffisant les vis ou le module risquent de tomber Un serrage excessif peut endommager la vis ou le module et entrainer leur chute viter tout contact direct avec les parties conductrices ou les composants lectroniques du module Toucher aux parties conductrices pourrait endommager le module ou provoquer des dysfonctionnements A 8 P cautions de cablage A AVERTISSEMENT Couper compl tement l alimentation externe utilis par le syst me avant de mettre avant raccorder les c bles Ne pas couper compl tement toutes les alimentations expose au risque de chocs lectriques et d endommagement du produit Avant de mettre sous tension et de mettre en marche le module la fin des travaux d installation et de c blage ne oublier de refermer le couvre bornes fourni Faute de quoi il y a risque de choc lectrique A 9 P cautions c blage A ATTENTION 1 est indispensable de mettre les bornes FG et les bornes LG la masse sur le conducteur de terre faute de quoi il y a risque de choc lectrique ou de fonctionnement erratique Pour tout c blage dans l automate programmable s assurer que c est possible compte tenu de la tension nominale du produit et de l affectatio
29. lculated by the following formula PFD PFH A B C D Calculation formula of PFD PFH Variable Definitioi Total PFD PFH of the safety CPU module safety power supply module safety main base unit and CC Link Safety system master module PFD PFH of the CC Link Safety system remote module 1 When safety input device s and safety output device s are connected to the same CC Link Safety system remote I O module B B1 2 When safety input device s and safety output device s are connected to different CC Link Safety system remote I O modules B B1 B2 PFD PFH of the CC Link Safety system remote module to which safety input device s is connected PFD PFH of the CC Link Safety system remote module to which safety output device s is connected PFD PFH of safety input device s PFD PFH of safety output device s 1 For the values refer to the manual for the safety component used The following tables show the PFD PFH values for the safety remote I O module PERI PFD PFH of the QSOJ65BTS2 8D 1 68 107 7 46x10 10 19 8 DECLARATION OF CONFORMITY FOR MACHINERY DIRECTIVE EC Declaration of Conformity Manufacturer Mitsubishi Electric Corporation Nagoya Works Address 1 14 5 chome Yada Minami Higashi ku Nagoya 461 8670 Japan Products Type Programmable Controller Open Type equipment Installation category 11 Model QS0 Series Applicable units identified
30. lectric Europe B V French Branch 25 Boulevard des Bouvets F 92741 Nanterre Cedex France Tel 33 1 5568 5568 Mitsubishi Electric Europe B V o s Czech office Avenir Business Park Radicka 751 113e 158 00 5 Czech Republic Tel 420 251 551 470 Mitsubishi Electric Europe B V Polish Branch ul Krakowska 50 32 083 Balice Poland Tel 48 12 630 47 00 Mitsubishi Electric Europe B V Russian Branch St Petersburg office Piskarevsky pr 2 bld 2 lit Sch BC office 720 195027 St Petersburg Russia Tel 7 812 633 3497 Country Region Sales office Tel South Africa China Taiwan Korea Singapore Thailand Indonesia India Australia CBI Electric Private Bag 2016 ZA 1600 Isando South Africa Tel 27 11 977 0770 Mitsubishi Electric Automation China Ltd No 1386 Hongqiao Road Mitsubishi Electric Automation Center Changning District Shanghai China Tel 86 21 2322 3030 Setsuyo Enterprise Co Ltd 6F No 105 Wugong 3rd Road Wugu District New Taipei City 24889 Taiwan R O C Tel 886 2 2299 2499 Mitsubishi Electric Automation Korea Co Ltd 1480 6 Gayang Dong Gangseo Gu Tel 82 2 3660 9530 Mitsubishi Electric Asia Pte Ltd Industrial Division 307 Alexandra Road Mitsubishi Electric Building Singapore 159943 Tel 65 6470 2308 Mitsubishi Electric Automation Thailand Co Ltd Bang Chan Industrial Estate No 111
31. loose it may cause a drop of the screw or module Overtightening the screw may cause a drop due to the damage of the Screw or module Do not install the control lines or communication cables together with the main circuit lines or power cables Failure to do so may result in malfunction due to noise Be sure there are no foreign substances such as sawdust or wiring debris inside the module Such debris could cause fires damage or erroneous operation Be sure to fix the communication cables or power cables by ducts or clamps when connecting them to the module Failure to do so may cause damage of the module or cables due to a wobble unintentional shifting or accidental pull of the cables or malfunctions due to poor contact of the cable When removing the connected communication cables or power cables do not pull the cable with grasping the cable part Remove the cable connected to the terminal block after loosening the terminal screws Pulling the cable connected to a module may result in malfunctions or damage of the module or cable 4 Startup Maintenance Precautions WARNING Do not touch the terminals while power is Doing so could cause shock or erroneous operation Turn off all phases of the external supply power used in the system when cleaning the module or retightening the terminal block mounting screws terminal screws or module mounting screws Not doing so could result i
32. n SAFETY PRECAUTIONS Chapter 4 Additions CONDITIONS OF USE FOR THE PRODUCT Section 1 1 2 5 2 6 Chapter 7 8 Apr 2011 IB NA 0800414 D Correction SAFETY PRECAUTIONS Section 2 2 2 5 Chapter 8 Aug 2011 IB NA 0800414 E Correction SAFETY PRECAUTIONS Section 2 1 4 1 Additions SAFETY PRECAUTIONS Chinese Nov 2013 IB NA 0800414 F Correction Section 2 1 Additions Section 5 5 Jun 2014 1B NA 0800414 G Correction Section 2 1 2 2 2 5 4 1 5 2 Chapter 8 Additions SAFETY PRECAUTIONS French This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual 2008 MITSUBISHI ELECTRIC CORPORATION A 13 CONTENTS 4 MOUNTING AND INSTALLATION 6 EXTERNAL DIMENSIONS WIRING OVERVIEW e tete pee test 1 1 1 Safety Programmable Controller Product List SPECIFICATIONS 2 1 General Specifications 2 2 2 Performance Specifications 3 2 3 Cable Specifications 2 4 Confirming Production Information 2 5 Safety Standards 5 ode eee eges 7 2 6 Module Replacement
33. n des bornes Le raccordement d une alimentation d une tension autre que la tension nominale ou une erreur de c blage du produit peut tre l origine d un d part de feu ou d une panne Serrer les vis de fixation du bornier les vis de borne et les vis de fixation du module dans les limites du couple de serrage prescrit Une vis de fixation de bornier ou un vis de borne mal serr e peut tre l origine d un court circuit d un d part de feu ou de dysfonctionnements Un serrage excessif peut endommager la vis et ou le module et une chute de vis ou de module risque d entrainer un court circuit ou des dysfonctionnements Un serrage insuffisant des vis de fixation de module peut tre l origine d une chute des vis ou du module Un serrage excessif peut endommager la vis ou le module et entrainer leur chute Ne pas entrem ler les lignes de commandes ou c bles de communication avec les lignes des circuits principaux ou les c bles d alimentation Faute de quoi il y a risque de dysfonctionnement par un bruit 0 Veiller ce qu il n y ait pas de sciure ou autre d bris de c blage dans le module Tout d bris pourrait tre l origine d un d part de feu d une panne ou d un dysfonctionnement Les c bles de communication ou c bles d alimentation raccord s au module doivent tre plac s dans des conduits de c bles ou doivent tre attach s Faute de quoi il y a risque d endommagement du module ou du c ble par ballottem
34. n electric shock Tighten a terminal block mounting screw terminal screw and module mounting screw within the specified torque range If the terminal block mounting screw or terminal screw is too loose it may cause a short circuit fire or malfunctions If too tight it may damage the screw and or the module resulting in a drop of the screw or module a short circuit or malfunctions If the module mounting screw is too loose it may cause a drop of the screw or module Overtightening the screw may cause a drop due to the damage of the screw or module Do not disassemble or modify the modules Doing so could cause a failure malfunctions injury or fire If the product is repaired or remodeled by other than the specified FA centers or us the warranty is not covered Do not mount remove the module to from the base unit or terminal block more than 50 times IEC61131 2 compliant after the first use of the product Failure to do so may cause module malfunctions Since the module case is made of resin do not drop or apply any strong impact to the module Doing so may damage the module Completely turn off the externally supplied power used in the system before mounting or removing the module to from the panel Not doing so could result in damage to the product Disposal Precautions NCAUTION When disposing of this product treat it as industrial waste A 5 PRECAUTIONS DE S CURIT Toujours lire ces instructi
35. ne d un accident Pour interdire tout red marrage sans intervention manuelle apr s d clenchement de la fonction de s curit du module et mise hors tension des sorties pr voir un circuit de mise en s curit avec poussoir de r armement A 7 N ATTENTION Ne pas grouper les fils des dispositifs externes ou cables de communication avec les fils des circuits principaux ou de l alimentation et ne pas les installer proximit les uns des autres Ils doivent tre install s une distance de 100mm 3 94 pouces les uns des autres Faute de quoi il y a risque de bruit entra nant des dysfonctionnements 0 En choisissant les dispositifs externes raccorder au module E S distant de s curit CC Link prendre en compte l intensit maximum admissible du courant d appel en se reportant au manuel de l utilisateur du module E S distant pour syst me de s curit CC Link Pr cautions d installation N ATTENTION Un automate programmable de s curit doit tre utilis dans un environnement conforme aux sp cifications g n rales expos es dans le QSCPU User s Manual Hardware Design Maintenance and Inspection le Manuel de l utilisateur QSCPU conception du mat riel maintenance et inspection L utilisation de cet automate programmable dans un environnement autre que celui pr vu dans les sp cifications g n rales peut tre l origine d un choc lectrique d un d part de feu ou d un fonctionnement errat
36. nection with improperly designed incompatible or defective hardware or software 5 that fails because consumable parts such as batteries backlights or fuses were not tested serviced or replaced 6 operated or used with equipment production lines or systems that do not meet applicable and commensurate legal safety and industry accepted standards 7 operated or used in abnormal applications 8 installed operated or used in contravention of instructions precautions or warnings contained in MELCO s user instruction and or safety manuals technical bulletins and guidelines for the Products 9 used with obsolete technologies or technologies not fully tested and widely accepted and in use at the time of the Product s manufacture 10 subjected to excessive heat or moisture abnormal voltages shock excessive vibration physical damage or other improper environment or 11 damaged or malfunctioning due to Acts of God fires acts of vandals criminals or terrorists communication or power failures or any other cause or failure that results from circumstances beyond MELCO s control f All Product information and specifications contained on MELCO s website and in catalogs manuals or technical information materials provided by MELCO are subject to change without prior notice 9 The Product information and statements contained MELCO s website and in catalogs manuals technical bulletins or other materials provided by MELCO are provide
37. ons avant utilisation de l quipement Avant d utiliser le produit pri re de lire ce manuel et la documentation laquelle il renvoie les manuels des automates programmables standard et les normes de s curit pertinentes et toujours consid rer la s curit comme de la plus haute importance en manipulant le produit correctement Dans ce manuel les instructions de s curit sont class es AVERTISSEMENT ou ATTENTION ewe ee ee Attire l attention sur le fait qu une n gligence peut 1 AVER TISSEMENT cr er une situation de danger avec risque de mort ou de blessures graves Attire l attention sur le fait qu une n gligence peut ATTEN TION cr er une situation de danger avec risque de blessures l g res de gravit moyennes ou risque de d g ts mat riels J gp On remarquera que m me au niveau ATTENTION les cons quences peuvent tre graves dans certaines circonstances Les instructions de ces deux niveaux doivent toujours tre respect es car elles concernent la s curit des personnes Pri re de lire attentivement ce manuel et veiller le transmettre l utilisateur final qui doit pouvoir s y r f rer autant que de besoin A 6 Pr cautions lors de la conception A AVERTISSEMENT Quand l automate programmable de s curit d tecte une erreur dans une alimentation externe ou une panne de module principal d automate
38. plies with the EMC Low Voltage and Machinery Directives Before using this product please read this manual the relevant manuals the manuals for standard programmable controllers and the safety standards carefully and pay full attention to safety to handle the product correctly The descriptions are based on the requirements of the Directives and the harmonized standards However they do not guarantee that the entire machinery constructed according to the descriptions complies with the EMC Low Voltage and Machinery Directives The manufacture of the machinery must determine the testing method for compliance and declare conformity to the EMC Low Voltage and Machinery Directives 2 15 1 OVERVIEW This manual describes the specifications and handling and wiring methods of the safety remote I O module of the CC Link Safety system After unpacking confirm that the following are included Item Quantity QS0J65BTS2 8D CC Link Safety System Remote 1 Module User s Manual Hardware QS0J65BTS2 8D 1 1 Safety Programmable Controller Product List Product Name Model Description A safety input module connected to external siu ah QS0J65BTS2 8D devices The module has eight safety input points yA module sends receives safety data to from the safety programmable controller over CC Link Safety 2 SPECIFICATIONS 2 1 General Specifications The general specifications of the QS0J65BTS2 8D a
39. r FG M3 x 5 2 Tightening torque 0 425 to 0 575N m 2 solderless terminals or less Bornier 7 points deux pi ces Circuit de transmission alimentation module FG M3 x 5 2 Couple de serrage 0 425 0 575 Nem 2 bornes sans soudure ou moins External power supply section input section Section alimentation externe section entr e Two piece spring clamp terminal block External power supply input section Bornier trier deux pi ces Alimentation externe section entr e Module mounting screw M4 screw with plain washer finished round Tightening torque 0 824 to 1 11 Mountable with a DIN rail and in 6 orientations Applicable DIN rail TH35 7 5Fe TH35 7 5Al Compliant with IEC 60715 Applicable wire size Taille du fila utiliser Item Communication section module power supply DC input module QS0J65BTS2 8D Section 0 3 to 2 0mm Section me 0 3 2 0 mm communication section alimentation du module RAV1 25 3 Applicable Applicable wire size 0 3 to 1 25mm solderless 7 2 53 JST Mfg Co Ltd RAP2 3SL Nippon Tanshi Co Ltd terminal TGV2 3N Nichifu Applicable wire size 1 25 to 2mm Borne sans RAV1 25 3 soudure Taille du fil utiliser 0 3 1 25 mm utiliser V2 MS3 JST Mfg Co Ltd RAP2 3SL Nippon Tanshi Co Ltd TGV2 3N Nichifu Taille de fil utiliser 1 25 2mm External power supply section inp
40. re shown below Item Specification Operating ambient temperature 0 to 55 C Temp rature ambiante de 0 55 fonctionnement Storage ambient 40 to 75 C temperature Operating ambient humidity 5 to 95 RH non condensing Storage ambient humidity Constant Half Sweep acceleration amplitude count 5 to 8 4Hz 3 5mm 10 times Compliant Under Sachin with JIS intermittent to 2 XYZ vibration 9 8m s e 3502 and 150Hz directions IEC 61131 2 Frequency Vibration resistance Under 5 to 8 4Hz Fia continuous 8410 vibration 150 2 4 9m s Compliant with JIS 3502 and IEC 61131 2 147m s duration of action 11ms Shock resistance 3 times each in 3 directions X Y Z by sine half wave pulse Operating atmosphere No corrosive gases Operating altitude 0 to 2000m Installation location Inside a control panel 1 ll or less Overvoltage category Pollution degree 2 or less Equipment class Class 1 This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution network and the machinery within premises Category II applies to equipment for which electrical power is supplied from fixed facilities The surge voltage withstand level for up to the rated voltage of 300V is 2500V 2 This index indicates the degree to which conductive material i
41. s generated in terms of the environment in which the equipment is used Pollution degree 2 is when only non conductive pollution occurs A temporary conductivity caused by condensing must be expected occasionally 3 Do not use or store the programmable controller under pressure higher than the atmospheric pressure of altitude Doing so may cause malfunction When using the programmable controller under pressure please consult your local Mitsubishi representative 2 2 Performance Specifications The performance specifications of the QSOJ65BTS2 8D are shown below Item No of input points DC input module QS0J65BTS2 8D 8 points doubling input 16 points single input Isolation method Photocoupler Rated input voltage 24V DC Rated input current Approx 5 9mA Operating voltage range 19 2V to 28 8V DC Ripple ratio 5 or less Maximum number of simultaneous input points 10096 ON voltage ON current 15V DC 2mA or more OFF voltage OFF current 5V DC 0 5mA or less Input resistance Approx 4 3k Q Input format Negative common source type Response 0 4ms or less at 24V DC time OFF 0 4ms or less at 24V DC Safety remote station input response time 11 2ms or less time of noise removal filter 1ms 5ms 10ms 20ms 50ms Voltage 19 2V to 28 8V DC Ripple ratio 5 or less External Current 40mA 24
42. s vis ou du module Un serrage excessif peut endommager la vis ou le module et leur chute N ATTENTION Ne pas d monter ni modifier les modules Cela pourrait tre l origine de pannes de dysfonctionnements de blessures ou d un d part de feu dysfonctionnements Si le produit est r par ou modifi par quiconque autre que nous m mes ou un de nos centre d automatisation industrielles agr s il n est plus couvert par la garantie 0 Apr s la mise en service du produit ne pas installer retirer le module de l unit de base ou de la plaque bornes plus de 50 fois selon IEC61131 2 Faute de quoi il y a risque de dysfonctionnements du module Ne pas faire tomber ou soumettre le module des chocs car son boitier en plastique est fragile Cela risquerait d endommager le module Couper compl tement toute alimentation externe utilis e par le syst me avant de mettre en place ou de retirer le module du tableau Faute de quoi il y a risque d endommagement du produit Pr caution de mise au rebut A ATTENTION Lors de sa mise au rebut ce produit doit tre trait comme un d chet industriel A 11 CONDITIONS OF USE FOR THE PRODUCT 6 1 Although MELCO has obtained the certification for Product s compliance to the international safety standards IEC61508 EN954 1 18013849 1 from TUV Rheinland this fact does not guarantee that Product will be free from any malfunction or failur
43. sole arbitrator chosen from the CPR s panels of distinguished neutrals Judgment upon the award rendered by the Arbitrator shall be final and binding and may be entered by any court having jurisdiction thereof The place of the arbitration shall be New York City New York The language of the arbitration shall be English The neutral organization designated to perform the functions specified in Rule 6 and Rules 7 7 b 7 8 and 7 9 shall be the CPR 26 Country Region Sales office Tel USA Brazil Germany UK Italy Spain France Czech Republic Poland Russia When exported from Japan this manual does not require Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 USA Tel 1 847 478 2100 MELCO TEC Representacao Comercial e Assessoria Tecnica Ltda Av Paulista 1439 cj74 Bela Vista Sao Paulo CEP 01311 200 SP Brazil Tel 55 11 3146 2200 Mitsubishi Electric Europe B V German Branch Gothaer Strasse 8 D 40880 Ratingen Germany Tel 49 2102 486 0 Mitsubishi Electric Europe B V UK Branch Travellers Lane Hatfield Hertfordshire AL10 8XB UK Tel 44 1707 27 6100 Mitsubishi Electric Europe B V Italian Branch Viale Colleoni 7 20864 Agrate Brianza Milano Italy Tel 39 039 60531 Mitsubishi Electric Europe B V Spanish Branch Carretera de Rubi 76 80 AC 420 E 08190 Sant Cugat del Valles Barcelona Spain Tel 34 93 565 3131 Mitsubishi E
44. ting to the Products or defects in them consist of personal injury wrongful death and or physical property damages as well as damages of a pecuniary nature the disclaimers and limitations contained in these terms shall apply to all three types of damages to the fullest extent permitted by law If however the personal injury wrongful death and or physical property damages cannot be disclaimed or limited by law or public policy to the extent provided by these terms then in any such event the disclaimer of and limitations on pecuniary or economic consequential and incidental damages shall nevertheless be enforceable to the fullest extent allowed by law f In no event shall any cause of action arising out of breach of warranty or otherwise concerning the Products be brought by Customer more than one year after the cause of action accrues g Each of the limitations on remedies and damages set forth in these terms is separate and independently enforceable notwithstanding the unenforceability or failure of essential purpose of any warranty undertaking damage limitation other provision of these terms or other terms comprising the contract of sale between Customer and MELCO 25 4 Delivery Force Majeure a Any delivery date for the Products acknowledged by MELCO is an estimated and not a promised date MELCO will make all reasonable efforts to meet the delivery schedule set forth in Customer s order or the purchase contract but shall not be
45. tion File This is supported by selected product tests to the following standards directly and indirectly when Generic standards are used Note The mentioned products must be used as direcled by the associated documentation in order to provide full compliance Harmonized European Standards Reference No Date of Issue EN 15013849 1 2008 Modules marked with a mark 5 have been tested to EN 15013849 1 2008 This declaration is based on the conformity assessment of following Notified Body RHEINLAND INDUSTRIE SERVICE GMBH Rheinland Group NB 0035 Am Grauen Stein D 51105 K ln Germany Phone 49 221 8060 49 221 806114 is de tuv com Website http www tuv com EC Type Examination Certificate 01 205 5201 01 13 Ji n Mitsushiro Fujishima Manager Safety Products Strategy planning group FA Systems Dept 2 Revision record 30 March 2011 QS0J71GF11 T2 added to the list C 12 June 2013 EC Type Examination Certificate has been updated D 20December2013 Type Examination Certificate has been updated BCN P9999 0618 D 21 22 WARRANTY Please confirm the following product warranty details before using this product 1 Limited Warranty and Product Support a Mitsubishi Electric Company MELCO warrants that for a period of eighteen 18 months after date of delivery from the point of manufacture
46. ued 23 2 Limits of Warranties a MELCO does not warrant or guarantee the design specify manufacture construction or installation of the materials construction criteria functionality use properties or other characteristics of the equipment systems or production lines into which the Products may be incorporated including any safety fail safe and shut down systems using the Products b MELCO is not responsible for determining the suitability of the Products for their intended purpose and use including determining if the Products provide appropriate safety margins and redundancies for the applications equipment or systems into which they are incorporated c Customer acknowledges that qualified and experienced personnel are required to determine the suitability application design construction and proper installation and integration of the Products MELCO does not supply such personnel d MELCO is not responsible for designing and conducting tests to determine that the Product functions appropriately and meets application standards and requirements as installed or incorporated into the end user s equipment production lines or systems e MELCO does not warrant any Product 1 repaired or altered by persons other than MELCO or its authorized engineers or FA Centers 2 subjected to negligence carelessness accident misuse or damage 3 improperly stored handled installed or maintained 4 integrated or used in con
47. ut section Section alimentation externe section entr e Twisted wire 0 08 to 1 5mm 28 to 16AWG 3 Applicable wire strip length 8 to 11mm Fil torsad 0 08 1 5mm 28 16AWG 3 Longueur de fil d nuder 8 11mm Applicable solderless terminal Borne sans soudure utiliser TEO 5 Nichifu Applicable wire size 0 5mm TEO 75 Nichifu Applicable wire size 0 75mm TE1 Nichifu Applicable wire size 0 9 to 1 0mm TE1 5 Nichifu Applicable wire size 1 25 to 1 5mm FA VTC125T9 Mitsubishi Electric Engineering Co Ltd Applicable wire size 0 3 to 1 65mm FA VTCW125T9 Mitsubishi Electric Engineering Co Ltd Applicable wire size 0 3 to 1 65mm TEO 5 Nichifu Taille de fil utiliser 0 5mm 0 75 Nichifu Taille de fil utiliser 0 75mm Nichifu Taille de fil utiliser 0 9 1 0mm 1 5 Nichifu Taille de fil utiliser 1 25 1 5mm 12579 Mitsubishi Electric Engineering Co Ltd Taille de fil utiliser 0 3 1 65mm FA VTCW125T9 Mitsubishi Electric Engineering Co Ltd Taille de fil utiliser 0 3 1 65mm 1 The power supply connected to the QS0J65BTS2 8D must satisfy the following conditions 1 Reinforced insulation SELV Safety Extra Low Voltage Hazardous potential part 48V or more 2 Compliance with the LVD Low Voltage Directive 3 Output voltage within 19 2V to 28 8V D