         Contents
1.   Sand  Soil  Water  Ice  Snow  Glass  Ceramic  Marble  Plaster  Mortar  Brick      0 90 to 0 98  0 94    0 96  0 90  0 92 to 0 96  0 92 to 0 96    0 96 to 0 98    0 83      0 90 to 0 95    0 90 to 0 94  0 94   0 80 to 0 90    0 89 to 0 91  0 93 to 0 96    Cloth  black    Skin  human   Leather   Charcoal  powder   Lacquer   Lacquer  matt   Rubber  black   Plastic   Timber   Paper   Chromium Oxides  Copper Oxides  lron Oxides    Textiles       0 98  0 98    0 75 to 0 80  0 96  0 80 to 0 95  0 97  0 94    0 85 to 0 95    0 90  0 70 to 0 94  re   0 78    0 78 to 0 82  0 90    Model 42515 V4 1 1 08    Specifications    Infrared Thermometer  Non contact  Specifications    Range   Resolution   58 0 to 1472 0  F   50 0 to 800 0  C  Resolution  0 1      Accuracy     58 to 30  F   50 to  1   C    2 0 rdg or  6  F 3  C  whichever is greater    31  F to 150  F   0 5 to 65  C    2 0 rdg or  4 5  F 2 5  C  whichever is greater    151   F to 600  F  66 to 315  C    2 0 rdg or  4  F 2  C  whichever is greater    600F to 1472  F  316 to 800  C       2 5 rdg   5  F 2 5  C     Field of View    Note  Accuracy is specified for the following ambient temperature  range  73 to77  F  23 to 25  C     D S   Approx  13 1 ratio  D   distance  S   spot or target     0 10 to 1 00 adjustable  Automatic adjust above 212  F or 100  C     Class 2 laser  lt  1mW power  Wavelength is 630 to 670nm  IR Spectral response  8 to 14 um  wavelength        Type K Thermocouple  Contact  Specifications    Range   Resolut
2. 02451       Copyright    2008 Extech Instruments Corporation  All rights reserved including the right of reproduction in whole or in part in any form     10 Model 42515 V4 1 1 08    
3. 1 1 08    Operating Instructions    IR  non contact  Measurements    1   2     Hold the meter by its handle and point it toward the surface to be measured     Pull and hold the trigger to turn the meter on and begin testing  The temperature  reading  the flashing    SCAN    icon  the emissivity  and the unit of measure will appear   Note  Replace the 9V battery if the display does not switch on     Release the Trigger and the reading will hold for approximately 7 seconds  HOLD will  appear on the LCD  after which the meter will automatically shut off  The only  exception to this is if the TEST LOCK switch is set to ON     Note  Select the temperature units    F   C  using the top switch inside the battery  compartment    Backlight Laser Pointer    1     2    3   4     While pulling the Trigger  push the backlight laser button TA once to turn on the  backlight     Press it again to turn on the laser pointer  When the laser is ON the laser icon    will  appear in the LCD     Press the laser button to turn the backlight off   Pressing it again turns the laser off   Note  Backlight and Laser settings will be retained after the meter powers down     Type K  contact  Measurements    le    wo N    4     Plug the Type K thermocouple sensor into the jacks at the bottom of the instrument   The jack accepts a standard sub miniature connector  Note that one plug spade is  wider than the other and the plug can only be inserted into the meter in one direction     Pull the trigger to turn t
4. User Manual             EXT    INSTRUMENTS    Wide Range InfraRed  IR  Thermometer  with Type K input and Laser Pointer    MODEL 42515       Introduction    Congratulations on your purchase of the Model 42515 IR Thermometer  The Model 42515  IR thermometer measures and displays non contact  infrared  temperature readings up to  1472  F  800  C   The built in laser pointer increases target accuracy while the backlit LCD  and handy push buttons combine for convenient  ergonomic operation  The Type K  thermocouple input provides contact measurements up to 2498  F  1370  C    The  adjustable emissivity feature allows the IR thermometer to measure the temperature of  virtually any surface  Proper use and care of this meter will provide years of reliable  service       The supplied thermocouple is rated for 482  F  250  C      Warranty    EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and  workmanship for three years from date of shipment  a six month limited warranty applies on sensors and  cables   If it should become necessary to return the instrument for service during or beyond the warranty  period  contact the Customer Service Department at  781  890 7440 ext  210 for authorization or visit our  website at www extech com  click on    Contact Extech    and go to    Service Department    to request an RA  number   A Return Authorization  RA  number must be issued before any product is returned to Extech  The  sender is responsible for shi
5. ensor to the surface and  at the same time  take an IR reading     5  When both the IR and the Type K measurements stabilize  press the UP or DOWN  arrow button  The new emissivity value will now be displayed     6  Proceed to take measurements     5 Model 42515 V4 1 1 08    Over range Indicator    If the temperature measurement exceeds the specified temperature range  the thermometer  will display dashes in place of a temperature reading     High and Low Alarm Feature    The Model 42515 has an alarm feature whereas a High Alarm setting and a Low Alarm  setting can be programmed by the user  When either Alarm point is reached the meter will  alert the user via an audible beep and LCD display icon  Follow the steps below     1  Press the MODE button until the HAL  High Alarm  parameter is displayed  Use the  UP and DOWN arrow keys to set the desired High Alarm setting     2  Press the MODE button until the LAL  Low Alarm  parameter is displayed  Use the  UP and DOWN arrow keys to set the desired Low Alarm setting     3  When an alarm limit is reached  the audible alarm will sound and the display icon  HIGH or LOW will appear in the lower right hand corner of the LCD     4  Note that if the bottom dip switch  located in the battery compartment  is set to OFF   the audible alarm will be disabled     Battery Replacement    When the low battery symbol    appears on the lower left side of the  display  replace the meter   s battery  9V   The battery compartment is  located behind t
6. function   In the MIN mode  only the lowest reading is displayed  DIF  Max minus Min value   In the DIF mode  the MAX less the MIN is displayed   AVG  Average value     In the AVG mode  all of the readings in the current measurement session are  averaged and the value is displayed     HAL  High Alarm setting   The temperature that  when exceeded  causes the audible visual alarm to trip    LAL  Low Alarm setting   The temperature that  when exceeded high to low  causes the audible visual alarm to  trip    T k  Type K contact thermocouple sensor function     The temperature reading of the Type K contact probe is shown next to the    T k    icon display   lf the sensor is not correctly inserted to the meter the display will show all dashes              The  supplied thermocouple is rated for 482  F  250  C      Automatic Emissivity Adjustment    The 42515 has the ability to automatically calibrate the emissivity setting  However  in  order to do so  the temperature of the measured surface must be above 212  F  100  C      Follow the steps below to use the automatic emissivity adjustment feature   1  Press the MODE button until the EMS  Emissivity  icon appears on the lower LCD line   2  Press and hold the Laser Backlight button until the EMS icon begins to blink and the    emissivity value is displayed as    __        3  The IR temperature will be displayed on the middle line of the LCD and the Type K  temperature will be displayed on the lower LCD line     4  Touch the Type K s
7. he instrument ON     In order to keep the instrument   s power on while testing  the user can a   hold the  trigger or b   lock the instrument on by setting the center dip switch to the ON position   switches are located inside of the battery compartment      Repeatedly press the MODE button until the bottom display line of the LCD reads    T K   The temperature shown to the right of the    T k    symbol is the temperature that the  Type K thermocouple is sensing     Hold the thermocouple in air or touch the tip of the sensor to the device that is to be  tested  The LCD   s bottom temperature display will provide the measurement value       The supplied thermocouple is rated for 482  F  250  C      4 Model 42515 V4 1 1 08    The MODE button options    The MODE button is used to access the programming functions of the instrument  The  selected function is displayed on the bottom line of the LCD  Each parameter is listed  below with a detailed account of its use  Press the MODE button to step from one  parameter to the next     EMS  Emissivity Value     To change the emissivity value  use the UP and DOWN arrows  the range is 0 10 to  1 00   The current emissivity setting is always shown at the top of the LCD display  A  setting of 0 95 covers about 90  of all applications  Emissivity is discussed in a  dedicated section of this manual     MAX  Maximum function   In the MAX mode  only the highest reading encountered in the current measurement  session is displayed  MIN  Minimum 
8. he light green panel that surrounds the meter   s trigger   see diagram   Open the compartment by pulling the light green panel  down from the trigger area  Replace the 9V battery and close the  battery compartment cover        6 Model 42515 V4 1 1 08    IR Measurement Notes    1     The object under test should be larger than the spot  target  size calculated by the field  of view diagram  printed on the side of the meter and in this guide      Before measuring  be sure to clean surfaces that are covered with frost  oil  grime  etc     If an object s surface is highly reflective  apply masking tape or flat black paint to the  surface before measuring  Allow time for the paint or tape to adjust to the temperature  of the surface it is covering     Measurements through transparent surfaces such as glass may not be accurate   Steam  dust  smoke  etc  can obscure measurements     The meter automatically compensates for deviations in ambient temperature  However   it can take up to 30 minutes for the meter to adjust to extremely wide changes     7  To find a hot spot  aim the meter outside the area of interest then scan across  in an up  and down motion  until the hot spot is located   Field of View    The meter   s field of view is 13 1  For example  if the meter is 13 inches from the target   spot   the diameter of the target must be at least 1 inch  Other distances are shown in the  field of view diagram  Note that measurements should normally be made as close as  possible to 
9. ion  58 0 to 1999 9  F   50 0 to 1370 0  C     Accuracy       1 5  of rdg   2  F or 1  C     Note  Accuracy is specified for the following ambient temperature  range  64 to 82  F  18 to 28  C          The supplied thermocouple is rated for 482  F  250  C      General Specifications  Display  Display update rate  Operating Temperature  Operating Humidity  Power Supply  Automatic Power Off  Weight    Dimensions    Backlit LCD display with function indicators  1 second approx     32  F to 122  F  0  C to 50  C    80  Relative Humidity max    Oy battery      Meter shuts off automatically after 7 seconds  6 4 oz    180g  3 2 x 1 6 x 6 3     82 x 42 x 160mm        9 Model 42515 V4 1 1 08    Calibration and Repair Services    Extech offers repair and calibration services for the products we sell  Extech also  provides NIST certification for most products  Call the Customer Service Department for  information on calibration services available for this product  Extech recommends that  annual calibrations be performed to verify meter performance and accuracy     T  Support line  781  890 7440  Technical support  Extension 200  E mail  support  extech com  Repair  amp  Returns  Extension 210  E mail  repair  extech com    Product specifications subject to change without notice  For the latest version of this User   s Guide  Software updates  and other  up to the minute product information  visit our website  www extech com  Extech Instruments Corporation  285 Bear Hill Rd   Waltham  MA 
10. pping charges  freight  insurance and proper packaging to prevent damage in  transit  This warranty does not apply to defects resulting from action of the user such as misuse  improper  wiring  operation outside of specification  improper maintenance or repair  or unauthorized modification  Extech  specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be  liable for any direct  indirect  incidental or consequential damages  Extech   s total liability is limited to repair or  replacement of the product  The warranty set forth above is inclusive and no other warranty  whether written or  oral  is expressed or implied     Safety  e Use extreme caution when the laser pointer is on  e Do not point the beam toward anyone s eye or allow CAUTI    N  the beam to strike the eye from a reflective surface  LASER RADIATION  DO NOT STARE INTO BEAM  1 DIODE LASER   lt 1mW Output at 675nm    CLASS II LASER PRODUCT          e Do not use the laser near explosive gases or in other  potentially explosive areas                2 Model 42515 V4 1 1 08    Meter Description    Laser pointer   IR Sensor   Measurement Trigger   Battery and Switch compartment  LCD Display   Function Buttons   Type K thermocouple    St oe ea a    Temperature units    C or   F  switch   Test lock ON   OFF switch   10  Alarm ON   OFF switch   Note that switches are located in the battery compartment behind the battery                                3 Model 42515 V4 
11. the device under test  The meter can measure from moderate distances but the  measurement may be affected by external sources of light  In addition  the spot size may  be so large that it encompasses surface areas not intended to be measured     Diameter of Spot 4     3          2       eseo    sosesocosososososososososososososososososoosse N  coesesesesese    sosesocososososososocososocosososeoooososooosoceososooooosososososososokn J seseseresresere      Distance to Object                      7 Model 42515 V4 1 1 08    Emissivity and IR Measurement Theory  IR Thermometers measure the surface temperature of an object  The thermometer   s optics  sense emitted  reflected  and transmitted energy  The thermometer   s electronics translate  the information into a temperature reading which is then displayed on the LCD     The amount of IR energy emitted by an object is proportional to an object s temperature  and its ability to emit energy  This ability is known as emissivity and is based upon the  material of the object and its surface finish  Emissivity values range from 0 1 for a very  reflective object to 1 00 for a flat black finish  For the Model 42515  the emissivity is  adjustable from 0 1 to 1 00  Most organic materials and painted or oxidized surfaces have  an emissivity factor of 0 95  When in doubt  set the emissivity to 0 95     Emissivity Factors for Common Materials    Material under test   Emissivity Material under test    _ Emissivity    Asphalt  Concrete  Cement
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
84100 carillon filaire chacon manuel fr    SERIE TAZIO 40/45/50 MANUALE USO E    Thermaltake TR2 Qfan 300W  Sussex Historic Landscape Characterisation: Volume I  ニア織田剛ロ勿ロ』ロ -  CEPEX CTD075.indd  intext:Bedienungsanleitung filetype:pdf  Systèmes de paiement: mOde d`emplOi    Copyright © All rights reserved. 