Home
TverTrip Profi v3.5 User Manual
Contents
1. TIS key to decrease it by 10 Frozen distance values recounted by the new calibration number To store new calibration number press F key or CLR STR1 to cancel 4 F CAL Start calibration kilometer calibration mode At the begining of calibration kilometer press F CAL and in the third line C00000 will be shown After passing calibration kilometer press F CAL in the third line new calibration number will be shown To store new calibration number press F key or CLR STR1 to cancel PAS Show in the third line speed average speed deviation from the mean speed Setup the mean speed In the first line current mean speed value will be shown Enter 3 digits of mean speed value with leading zero in kilometers per hour To store the mean speed press F key or CLR STR1 to cancel Show and change the current calibration number Press once to show the current calibration number press second time to change to another calibration number Exit from this mode will be done automatically after 3 seconds Current distance does not recalculated with a new calibration number Set calibration number Enter 5 digits with leading zeros To store new calibration number press F key or CLR STR1 to cancel Current distance does not recalculated with a new calibration number Set the total distance counter in the first line in tens meters Local distance from the second line will be added to this value Enter 5 digits with leading z
2. NOOSE the PD o 8 5 3 Calibration number SUD iS AS A AS R S 8 5 3 1 Ge A E O 9 5 3 2 E A A tude aout 9 5 3 3 Known distanc NN vend er ieo E TEA A iO loan E EER EE E EA ETERS 9 So Using GPS rec iyei nurni oe do 9 ia 9 Gel Commands dt a O dias 9 G2 Remote USA depa 12 E A gententbone clues Gia OREORE T REE RAS 13 1 Introduction TverTrip Profi is a rally computer purposed to help in the navigation in a difficult environment of any auto sports competitions which use roadbook s navigation such as rally rally raids trophy raids car orienteering It s already been used in world famous famous rally raids such Dakar Africa Race Silk Way It is very reliable lightweight and easy to use device If you are beginner in a navigation you will need only few buttons to control it during the race For skillful navigators it will help to control many parameters like speeding or average speed or distance limits 2 Technical specifications Operating temperature range 30 50 C Voltage 10 15V DC Current consumption less than 270mA Current consumption power save mode less than 40mA Nonvolatile memory battery CR2032 Battery resource more than one year Car s power network malfunction protection Yes Wrong polarity protection Yes Overvoltage protection Yes Device stores all current values in nonvolatile memory it allows to use TverTrip Profi without first setup procedures after its reconnection to power supply 3 Warranty The
3. kilometers per hour To F STR3 1 Set the maximum speed limit In case of exceeding of this speed limit external relay will be switched on continuously Enter 3 digits of speed limit value with leading zero in kilometers per hour To store it press F key or CLR STR1 to cancel 29 F STR3 3 Set the low speed limit In case of exceeding of this speed limit external relay will be switched in a pulse mode with a long period between pulses Enter 3 digits of speed limit value with leading zero in kilometers per hour To store it press F key or CLR STR1 to cancel F STR3 7 Set the current time value in 6 digit HHMMSS format hours minutes seconds Enter the leading zeros if hours or minutes values are less than 10 TverTrip uses 24h time format F STR3 9 Show the device firmware version Press any key to return back 6 2 Remote display control TverTrip Profi may be used with additional display for drivers TverTrip Pilot It helps to a driver to control current speed and local distance interval or any other parameters described in the table 4 To setup TverTrip Pilot you should do next steps on the TvetTrip Profi control panel 1 Press F CLR STR2 keys to set remote display control mode In the third line of TverTrip Profi El X will be shown where X is a parameter s number shown on the first line of remote display 2 Enter parameter number by pressing according number key On the third line E2 X will be shown w
4. two keyboard sections Left keyboard section has ten keys which work as function keys to change device s parameters display values and as numpad to enter numbers Right keyboard section consists of three clearing keys to zero different counters and F key used as Function key to change function keys behavior and as Enter key to finish commands 6 1 Commands list Some commands demands only one key some demands keys combination To enter keys combination you should press one key after another as described in a commands list For example F DST command means you should press F key release it then press DST key and release it You should not press several keys simultaneously only one by one If command demands some additional numbers input it is usually finished by F ENTER key or you may cancel command by CLR STR1 key Table 3 contains full commands descriptions listed by function keys numbers Table 3 Commands list Temen eos S S S FRZ Freeze Unfreeze values in the first and second display lines Reset local distance interval in the second line 2 F FRZ Switch off the display for power saving Only one point stays visible To turn on the display press any button besides F 3 CAL Start known distance calibration mode Freezes the first and second lines To change current calibration number press key to raise its value by 1 or PROBE to lower its value by 1 Press TIME key to increase it by 10 and
5. Press PROBE again to leave this mode To change active probe press 1 or 2 key accordingly 21 CLR In different setup modes is used to escape from value setting or exit to standard STR1 mode first line total distance second line local interval distance third line current speed To reset total distance counter in the first line press and hold this key more than 3 seconds 22 CLR Reset local distance counter in the second line STR2 F STR2 Remote display TverTrip Pilot control See section 6 2 for more details F STR2 Change remote display brightness 3 values 23 CLR Reset mean speed STR3 _ To reset all counters press and hold this key more than 5 seconds After reset the first probe and the first calibration number will be used as active 26 F STR3 0 Set and turn on the distance limit Enter 5 digits with leading zeros To store this value press F key or CLR STR1 to cancel If distance limit is set in the first digit in the third line symbol will be shown If this limit is reached external relay will be switched on To turn off alarm when it s on press CLR STR1 key To turn off distance limit press F CLR STR3 0 if distance limit is on 11 store it press F key or CLR STR1 to cancel F STR3 2 Set the medium speed limit In case of exceeding of this speed limit external relay will be switched in a pulse mode Enter 3 digits of speed limit value with leading zero in
6. TVERTRIP PROFI PROBE PRB1 CALI TSD CAS PRB 2 CAL2 AVR RS485 USER MANUAL TverTrip model Profi Firmware version 3 5 Manual edition 1 0 TverTrip Profi v 3 5 User manual www tvertrip com All product information may be changed without prior notice All statements information and recommendations in this guide are assumed correct but given without warranty of any kind express or implied Users must assume full responsibility for their use Developers manufactures and distributors of TverTrip devices are not liable for any indirect special or consequential damages including without limitation lost profits loss of or damage any cars equipment and any property arising from the use of or inability to use this guide even if developers manufactures of TverTrip devices its suppliers partners or distributors have been advised of the possibility of such damages TverTrip 2011 Contents WS SERNA CON st ea AN 4 2 Technical specifications enceinte o iS 4 Wafanya E O do 4 4 Installation ofthe A a nian ae oe ieee 4 4 1 WALES CES CHIPULOM jas sszoe5nldns cay htasecs bang Dd sled A EE EA Renu EE EA 4 A A O eRe lech tse ese meAta taal 5 Eo PODES CONDE CLOMN cr aisia a n os i a a a oath cede a aa aa e a 6 4 4 External relay only for TverTrip Profi Dakar editiOM ooooonnccninnononaconccooncconanccnonancncnannconnns 7 4 5 TVer NP SPOLb CONNECIOT it e aae A A NS AST 7 FICS Setup A ee a EA 8 SS US IS ASS 8 5 2 E
7. eros For example 05023 means 50 km 230 m To store distance press F key or CLR STR1 to cancel 10 F DST Show in the first line total distance current time 10 11 Change the total distance counter in the first line Distances in first and second lines will be frozen Press key to increase distance value by 10 meters or PROBE to decrease distance value by 10 meters TIME key increases by 100 meters TIS decreases by 100 meters All changes are saved immediately To exit from this mode press F or CLR STR1 key 12 F DSS Set the total distance counter in the first line in tens meters Enter 5 digits with leading zeros For example 05023 means 50 km 230 m Local distance counter will be zeroed To store distance press F key or CLR STR1 to cancel 13 TIME _ Show in the second line local distance stopwatch 14 F TIME Show in the third line deviation from the mean speed in seconds speed Value of the deviation may be positive or negaite as TIS Start Stop stopwatch fens Switch the direct or reverse distance count If a distance is displayed minus sign in its line will be shown KORZENI Change display brightness 3 values PROBE Switch on off speeding alarm via external relay When speeding alarm is on in the first digit of the third line symbol L will be shown 20 F PROBE Show the active probe in the third line P1 means first probe P2 means second probe is used
8. here X is a number of parameter shown on the second line of remote display 3 Enter second parameter s number by numpad Device will return back from this mode automaticaly Table 4 Remote display parameters Remote display parameter po itm SS 6 Deviation fom te mean ye ndo O a becal distance menad 12 7 Additional information Latest news documentation and additional information about TverTrip products you can get on the web site www tvertrip com Feel free to ask any questions via e mail by address info tvertrip com 13
9. hown on the third line To save it press F key or CLR STR1 to cancel 5 3 3 Known distance If there is a some known distance you may calibrate TverTrip Profy by this method Drive to the beginning of the distance reset local distance counter in the second line by pressing CLR STR2 key drive smoothly known distance and stop Press CAL key values on the first and second distance lines will be frozen now you may change calibration number by pressing key to increase it by 1 and PROBE key to decrease it by 1 use TIME key to increase it by 10 and TIS key to decrease it by 10 Frozen distances will be recounted with a new calibration number When you will get exact distance on a second line press F key to store calibration number or CLR STR1 to cancel any changes When you will have some experience in this method you may drive without stops through known distance You just have to press CLR STR2 and CAL keys in exact road points and adjust calibration number You even don t have to reset distance counter if you know distance value at the end of the used distance 5 3 4 Using GPS receiver This method suitable for both setup and check of the calibration number On a smooth and straight road drive a car with constant speed and set calibration number by any previously discussed ways thus both speeds on GPS receiver and TverTrip were equal 6 User interface TverTrip Profi has digit LED display with three lines and
10. ll three display lines should show zeros Time setup is not necessary for simple navigation but they are very helpful in competitions where time limits are used Calibration number setup is mandatory without correct calibration number TverTrip can t show correct distance and speed Calibration number depends on the probe s type car s transmission parameters wheels diameter and should be checked before an every race TverTrip Profi has two calibration numbers which may be swap or changed very quickly for example in case of the tires change during the race 5 1 Time setup To change a current time press in sequence F STR3 7 keys After that enter 6 digits of current time in HHMMSS format hours minutes seconds Enter the leading zeros if hours or minutes values are less than 10 To save the time value press F key or CLR STR1 to cancel 5 2 Choose the probe In case you have two probes connected to TverTrip Profi you have to choose one of them to operation Depending on probes types you may need to have different calibration numbers for different probes If both probes measure the same value for example they both installed on the one wheel you may use one calibration number for both probes To check which probe is being used now you have to press F and PROBE key In the third line will be shown P1 for first probe or P2 for second probe Press PROBE key again to return to normal display mode To change the curre
11. m shown on pictures depending on used probe types Refer to probe s documentation for details Picture 3 Universal speedometer probe connector 2 Picture 4 Hall effect sensor connector 2 Picture 5 VDO sensor connector 2 Warning VDO sensors have a low loading capacity We recomend to connect HALL1 and HALL2 inputs to different VDO sensor outputs In such scheme is permitted to connect in parallel up to 3 TverTrip Profi devices to one VDO sensor 4 4 External relay only for TverTrip Profi Dakar edition TverTrip Profi Dakar edition has additional connector for external relay which may switch on any alarm devices in cases of speeding or exceeding of other specified limits Picture 5 Connection of external alarm relay Relay should be for 12V DC Additional protection diode should be used according recommendations of relay manufacturer 4 5 TverTrip Sport connector If you already have previos version of TverTrip TverTrip Sport you may use its connector to connect TverTrip Profi In this case you have to solder TverTrip Profi wires to DB9 connector as shown in the table 2 Table 2 TverTrip Sport connector HALLI PROBEI Input Probe 1 HALL2 PROBE2 Input Probe 2 nd Power supply connect to car s 12V via 5A fuse DISP2 Remote display TverTrip Pilot data channel A 100mA max MEA 5 First setup After connecting the device check again all wires and connectors Switch power on a
12. manufacturer guarantees fault free operation of the TverTrip Profi within 12 months period from the date of manufacture Date of manufacture is determined by electronic mark stored inside the unit During warranty period repairing of TverTrip Profi is free of charge in the case of manufacturing defects In the case of physical damage claims for quality are not accepted Warranty does not apply to the battery 4 Installation of the device To use TverTrip Profi you have to install a device on car s dashboard at easy accessible to the navigator place then connect it to probes and car s electric network 4 1 Wires description Connect TverTrip Profi wires as decribed in the table 1 Power supply may be connected via a switch to power down the device when it s not used P N SSCS Table 1 Wires description Power supply connect to car s 12V via 5A fuse Car s ground Remote display TverTrip Pilot data channel 4 2 Connectors On the picture 1 jumper 5 9V sets the Hall s probe DC voltage on UHALL wire With jumper set on default UHALL 5V without jumper UHALL 9V Use the Hall s probe manual for reference Connector is used to connect standard inductive probes Connector 2 is used for power supply remote button remote display Connector 3 is used to connect standard probes Picture 1 Connectors 4 3 Probes connecton You may choose any connection variant suitable for your car Wires colors may differ fro
13. nt probe press F PROBE and 1 or 2 keys for the first or second probe accordingly 5 3 Calibration number setup Calibration number is a distance in millimeters which car passes from one pulse of probe to the next one To choose which calibration number will be used as active press CAS key the current calibration number will be shown To switch to another number press CAS key again Exit from this mode will be done automatically after 3 seconds If calibration number was changed current distance does not recalculated 5 3 1 Known calibration number If calibration number is known press F CAS keys and enter 5 digits of calibration number with leading zeros and press F key to store this number or CLR STR1 to cancel Current distance does not recalculated with a new calibration number In case of unknown calibration number it may be measured by different methods described below 5 3 2 Calibration kilometer In some races roadbooks are made by using so called calibration kilometer which may differ from the real one To setup TverTrip in such case you have to drive to the beginning of calibration kilometer some sign chosen by race organizer Stop the car press F CAL keys on third display line will be shown C00000 Drive car smoothly to the end of calibration kilometer stop the car and press F CAL keys Calibration number is fixed at the moment of pressing on CAL key New calibration number will be s