Liebert® PSP™

image

Contents

1. centers If this unit must be dismantled this must be done by specialized personnel who are properly trained and qualified The unit must be taken to a center specialized in collection and disposal of dangerous substances e For technical support e Visit www liebert com or e Send an e mail to upstech emersonnetworkpower com Step 5 Connect the Loads The UPS has three battery backup sockets that provide power when the UPS operates on bat tery There is also one surge only socket see Figure 2 below Erer I e Plug the loads into the battery backup sockets on the rear of the UPS Caution Do not connect a laser printer to the UPS Step 6 Connect the Network Surge Protection The UPS has two network cable jacks for network lines see Figure 2 below e Connect a single line network cable into the network surge protection IN jack on the rear of the UPS e Connect a network cable from the OUT jack on the rear of the UPS to a port on a PC or network device such as a router Step 7 Set Up Liebert MultiLink software To start using the Liebert MultiLink software Install the software See the Liebert MultiLink quick start guide or user manual for installation instructions e Connect one end of the USB cable supplied to the USB port on the rear of the UPS Connect the other end to a USB port on the computer See the Liebert MultiLink user manual for operating instructions Note Emerson recommends connect
2. 77 Via Leonardo Da Vinci 8 7 F Dah Sing Financial Centre 1050 Dearborn Drive y Liebert is a registered trademark of Liebert Corporation Outside U S 614 841 6755 Zona Industriale Tognana 108 Gloucester Road P O Box 29186 E RSON All names referred to are trademarks or registered trademarks upstech emersonnetworkpower com 35028 Piove Di Sacco PD Italy Wanchai Hong Kong Columbus OH 43229 of their respective owners Web site www liebert com 39 049 9719 111 852 2572 2201 IN T J SLI 23285_REV01_05 09 Fax 39 049 5841 257 Fax 852 2519 9210
3. Liebert PSP Quick Start Guide IMPORTANT SAFETY INSTRUCTIONS e Do not connect equipment that may overload the UPS or demand half wave rectification such as a laser printer e Connect the UPS only to an earthed grounded socket that meets electrical safety guidelines e Locate the UPS near a wall socket Do not use an extension cord between the UPS and the socket e Use CE marked cables only for connections between mains the UPS and equipment e The Liebert PSP has been designed for small office nome office use only it is NOT recommended for use in life support applications e Inthe event of an emergency press the On Off button and disconnect the power cord from the AC mains to properly disable the UPS SETUP Step 1 Inspect the Package Inspect the package and the UPS upon receipt Notify the carrier and dealer of visible damage The package includes e Liebert PSP e USB cable e Quick start guide 2 IEC e 2 IEC output cables output ices cables The Liebert MultiLink software may be Quick downloaded from the Liebert Web site at UPS start multilink liebert com guide See Step 7 for installation instructions Step 2 Decide Where to Place the UPS The UPS must be placed indoors protected from water direct sunlight and excessive heat Provide at least 100mm 4 of clearance on all sides of the unit for proper ventilation Step 3 Charge the UPS Battery Before Use The UPS battery is not charg
4. circuit breaker TE eres cen EVET poe cones SULINETES Battery voltage may be too low e Recharge the UPS for 8 hours no output power Alarm buzzer beeps continuously although mains is normal UPS does not provide expected backup time The UPS battery reached end of life e Replace the internal battery The UPS is on and connected to mains but fails to 7 l e f mains is normal try reconnecting mains and Mains power may be outside the unit s operating range operate properly restarting the UPS SPECIFICATIONS On Battery Wave Form Stepped sinewave o w O s e 350 Agency Safety IEC EN AS 62040 1 1 Note All run times are in minutes assume fully charged EN 62040 2 2005 Class B batteries and are typical at 25 C 77 F with resistive loads IEC 61000 4 2 Electrostatic discharge IEC 61000 4 3 Radiated E RFI fields IEC 61000 4 4 Fast E transients IEC 61000 4 5 Surges Lightning IEC 61000 4 6 Conducted RFI Transportation ISTA Procedure 1A Certification Note The Liebert PSP is compliant with the Restriction of Hazardous Substances Directive ROHS prohibiting use of six hazardous materials manufacturing of electronics including lead free solder Ronge The UPS may be overloaded check LED 2 e Disconnect some equipment from the UPS 2009 Liebert Corporation All rights reserved throughout the Technical Support Service Europe Asia United States world Specifications subject to change without notice 800 222 58
5. ed before shipping It MUST be charged before use e Use the input power cord from computer equipment as the input power cord of UPS Connect a user supplied power cord from the UPS to a wall socket and charge for at least eight hours Unit can be charged in the on or off state Note If battery is placed in storage charge the battery every six months if kept at 15 C to 29 C 5 F to 85 F or every three months if kept at 30 C 86 F or higher Step 4 Start the UPS After the battery is fully charged e Turn on the UPS by pressing the On Off button see Figure 1 below LED 1 should be illuminated green indicating the UPS is operating in Normal Mode UPS CONTROLS AND CONNECTIONS Figure 1 Front Panel LEDs On Off button Overload LED 1 symbol raan LED 2 red fault Mains amber overload gympa Fault symbol EMERSON Network Power Liebert PSP AC Power System UPS Status Alarm Conditions and Alerts EMERSON Network Power 500VA 650VA 230V e Do not attach power strips or surge suppressors to the UPS e Do not attempt to service any parts inside the UPS except when replacing the batteries Failure to adhere to this could cause personal injury or equipment malfunction and void the warranty e This unit uses components that are dangerous for the environment such as electronic cards and other electronic components Any component that is removed must be taken to specialized collection and disposal
6. ing the USB cable directly to the computer WITHOUT using a USB hub Figure 2 Rear Panel RJ 45 jacks 2 lt Network protection USB interface Mains breaker AC mains inlet Battery backup sockets 3 S IEC 320 C13 Surge socket 1 IEC 320 C13 Battery Mode LED 1 Flashes every 3 seconds Every 3 seconds Battery Low LED 1 Flashes every 1 second till end of discharge EOD Every 1 second Overload Battery Replacement LED 2 Red LED 2 Solid steady glow until load drops or breaker trips Continuous Flashes every 1 second for 5 seconds only Every 1 second for 5 seconds only LED 2 Red Solid steady glow until UPS shuts down after 5 seconds Continuous until UPS shuts down REPLACING THE BATTERY Servicing of batteries should be performed or supervised by personnel knowledgeable about batteries and required precautions When replacing batteries replace with the same type and size battery CAUTION A Do not dispose of batteries in a fire The batteries may explode A Do not open or mutilate batteries Released electrolyte is harmful to the skin and eyes It is toxic This product is designed for IT power systems with 230V To replace the battery 1 Turn off all connected loads then turn off the UPS and unplug the input a power cord Batteries are NOT hot swappable Electric Shock 2 Carefully lay the UPS on its left side as shown in the diagram 3 Use a 1 Phillips head screwd
7. river to remove the four screws from the right side cover then pull up the right side cover and remove it 4 Remove the black wire from the negative terminal and the red wire from the positive terminal 5 Gently remove the battery from the UPS Attention Risk of Electric Shock 6 Verify that the replacement battery matches the dimensions and battery specifications 7 Connect the battery leads to the new battery Be sure to reconnect the red wire to the positive terminal and the black wire to the negative terminal Note Small sparks may occur at the battery connectors during reconnection Take care not to short circuit the positive and negative battery terminals while replacing the battery 8 Place the battery in the UPS 9 Ensure correct alignment of front panel then reattach the right side cover Evenly tighten the four screws from Step 3 Do NOT overtighten screws Dispose of the old battery properly at an appropriate recycling facility TROUBLESHOOTING If the UPS detects a fault consult the table below for possible causes and solutions For further assistance please contact your local Emerson Network Power representative The UPS may not be turned on e Press the On Off button to turn on the UPS Mains is normal but LED 1 is not illuminated The power cord may not be connected properly e Connect the power cord securely into a wall socket The upstream mains circuit breaker may be tripped e Reset the

Download Pdf Manuals

image

Related Search

Related Contents

TRIAGE FORESTIER INTERCOMMUNAL DU SIGNAL DE BOUGY  user manual  Model 5500 Receiver Model 5700 Transmitter User`s  GWY-300 (CAN Gateway) - Renu Electronics Pvt. Ltd.  dry:soon 2 tier heated tower airer  CBP-2001CI+ User Guide  télécharger le programme du salon de la création  Smithco 72-000-A User's Manual  Mode d`emploi site Internet Charte qualité.pub  documentazione - Brinkmann Pumps  