1. AutomationDirect com Automation Direct E SWO5U Industrial Ethernet j LE LE E SWO5U 4 Real time Switch e Contents at a Glance Section 1 General Information Page 5 Section 2 LED Indicators Page 6 Section 3 Installation Page 7 Section 4 Power Wiring Page 8 Section 5 Ethernet Wiring Page 9 Section 6 Switching Features Page 11 Section 7 Technical Specifications Page 13 CE O A This manual applies to the Industrial Ethernet 5 port Switch E SWOSU E SWOSU User Manual Rev 1 Page 1 WARNING Thank you for purchasing automation equipment from Automationdirect com We want your new automation equipment to operate safely Anyone who installs or uses this equipment should read this publication and any other relevant publications before installing or operating the equipment To minimize the risk of potential safety problems you should follow all applicable local and national codes that regulate the installation and operation of your equipment These codes vary from area to area and usually change with time It is your responsibility to determine which codes should be followed and to verify that the equipment installation and operation are in compliance with the latest revision of these codes At a minimum you should follow all applicable sections of the National Fire Code National Electrical Code and the codes of the National Electrical Manufacturer s Association NEMA There may be local
2. This LED will be on solid when proper power has been applied to the unit ACT LNK The activity ACT and link LNK indication is combined into one LED on the Industrial LEDs Ethernet Switch There is one of these LEDs per port OFF This would indicate that there is not a proper Ethernet connection Link between the port and another Ethernet device Make sure the proper cable type is in use and that it has been plugged securely into the ports at both ends See section 5 for proper Ethernet cabling ON Solid not flashing This would indicate that there is a proper Ethernet connection Link between the port and another Ethernet device but no communications activity 1s detected Flashing This would indicate that there is a proper Ethernet connection Link between the port and another Ethernet device and that there is communications activity 10 100 This LED indicates what speed of communications is detected on the port There is one of these LEDs LEDs per RJ45 port OFF A 10 Mbps 10BaseT connection is detected ON A 100 Mbps 100BaseTx connection is detected Mbps Megabits per Second E SWOSU User Manual Page 6 of 13 Section 3 Installation Overview The Industrial Ethernet Switch can be snapped onto a standard DIN rail EN50022 or screwed directly to a flat panel Refer to the mechanical drawings below 0 28 1 10 LO 7 1cm gt CAC 2 92 Automation Direct 7 4
3. applicables r gissant l installation et le fonctionnement de votre quipement Ces codes diff rent d une r gion l autre et habituellement voluent au fil du temps I vous incombe de d terminer les codes respecter et de vous assurer que l quipement l installation et le fonctionnement sont conformes aux exigences de la version la plus r cente de ces codes Vous devez tout le moins respecter toutes les sections applicables du Code national de pr vention des incendies du Code national de l lectricit et des codes de la National Electrical Manufacturer s Association NEMA Des organismes de r glementation ou des services gouvernementaux locaux peuvent galement vous aider a d terminer les codes ainsi que les normes respecter pour assurer une installation et un fonctionnement s rs L omission de respecter la totalit des codes et des normes applicables peut entra ner des dommages l quipement ou causer de graves blessures au personnel Nous ne garantissons pas que les produits d crits dans cette publication conviennent votre application particuli re et nous n assumons aucune responsabilit l gard de la conception de l installation ou du fonctionnement de votre produit Nos produits ne sont pas insensibles aux d faillances et ne sont n1 con us n1 fabriqu s pour l utilisation ou la revente en tant qu quipement de commande en ligne dans des environnements dangereux n cessitant une s curit absolue par
4. exemple l exploitation d installations nucl aires les syst mes de navigation a rienne ou de communication le contr le de la circulation a rienne les quipements de survie ou les syst mes d armes pour lesquels la d faillance du produit peut provoquer la mort des blessures corporelles ou de graves dommages mat riels ou environnementaux activit s a risque lev La soci t Automationdirect com nie toute garantie expresse ou implicite d aptitude l emploi en ce qui a trait aux activit s risque lev Pour des renseignements additionnels touchant la garantie et la s curit veuillez consulter la section Modalit s et conditions de notre documentation Si vous avez des questions au sujet de l installation ou du fonctionnement de cet quipement ou encore si vous avez besoin de renseignements suppl mentaires n h sitez pas nous t l phoner au 770 844 4200 Cette publication s appuie sur l information qui tait disponible au moment de l impression la soci t Automationdirect com nous nous effor ons constamment d am liorer nos produits et services C est pourquoi nous nous r servons le droit d apporter des modifications aux produits ou aux publications en tout temps sans pr avis n1 quelque obligation que ce soit La pr sente publication peut aussi porter sur des caract ristiques susceptibles de ne pas tre offertes dans certaines versions r vis es du produit MARQUES DE COMMERCE La pr sente pu
5. regulatory or government offices that can also help determine which codes and standards are necessary for safe installation and operation Equipment damage or serious injury to personnel can result from the failure to follow all applicable codes and standards We do not guarantee the products described in this publication are suitable for your particular application nor do we assume any responsibility for your product design installation or operation Our products are not fault tolerant and are not designed manufactured or intended for use or resale as on line control equipment in hazardous environments requiring fail safe performance such as in the operation of nuclear facilities aircraft navigation or communication systems air traffic control direct life support machines or weapons systems in which the failure of the product could lead directly to death personal injury or severe physical or environmental damage High Risk Activities Automationdirect com specifically disclaims any expressed or implied warranty of fitness for High Risk Activities For additional warranty and safety information see the Terms and Conditions section of our Desk Reference If you have any questions concerning the installation or operation of this equipment or if you need additional information please call us at 770 844 4200 This publication is based on information that was available at the time it was printed At Automationdirect com we consta
6. 0 30 VDC see Section 7 for current draw Ethernet Standards IEEE 802 3 10BaseT 802 3u 100BaseTX 802 3x Full Duplex Ethernet Protocols All standard IEEE 802 3 protocols supported Speed Per Port RJ45 10 or 100 Mbps half duplex 20 or 200 Mbps full duplex Ethernet Isolation 1200 Volts RMS for 1 minute Operating Temp 40 to 85 C Humidity 5 to 95 non condensing Screw Terminals 5 port switch 14 AWG max tighten to 3 48 in lbs max The Industrial Ethernet Switch meets the following standards Electrical safety UL 508 CSA C22 14 EN61010 1 IECI010 EMI emissions FCC part 15 ICES 003 EN55022 Class B EMC immunity EN61326 1 EN61000 4 2 3 4 and 6 Hazardous locations UL 1604 CSA C22 2 213 Class 1 Div 2 Groups A B C D Cenelec EN50021 Zone 2 Install the Industrial Ethernet Switch in accordance with local and national electrical codes Lightning Danger Do not work on equipment during periods of lightning activity Do not connect a telephone line into one of the Ethernet RJ45 connectors E SWOSU User Manual Page 5 of 13 Section 2 LED Indicators Overview The Industrial Ethernet Switch has communication LEDs for each port and a power LED A Yi H 100 Miila z Supports Doterminisiic Etherwet LE hy a Open Ethernet Compatible elele AUTOMATIONDIREET ofa vee Wautomationdirect com Sales 1 800 633 0405 Support 770 844 4200 FIVE PORT SWITCH
7. HAZARD SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS 1 DIVISION 2 WARNING EXPLOSION HAZARD WHEN IN HAZARDOUS LOCATIONS DISCONNECT POWER BEFORE REPLACING OR WIRING UNITS WARNING EXPLOSION HAZARD DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NONHAZARDOUS FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help E SWOSU is not intended for residential use Copyright amp Tr
8. Pcn Sos Max r git ot Panel CH E SWOSU2 170 4450 8 05cm 4 47 T1135cm 4 7 o L 12 0 cm E SW05U clear for 8 screw 167 A een E SWOSU User Manual Page 7 of 13 Section 4 Power Wiring The Industrial Ethernet Switch can be powered from the same DC source that 1s used to power your I O devices 10 to 30 VDC needs to be applied to terminals 2 and 3 Refer to the wiring diagram below s s O N K ia N K o LN K Uplink Port Overview NK E oWo 10 30 VDC The screw terminals should be tightened to a maximum 3 48 in lbs 0 4 Nm E SWOSU User Manual Page 8 of 13 Section 5 Ethernet Wiring Overview The Industrial Ethernet Switch provides connections to Ethernet devices on the factory floor Typically the uplink port is used to connect to another Ethernet switch or hub that is connected to the main Ethernet backbone The other four Ethernet ports are then connected to Ethernet devices such as PLCs Ethernet I O or industrial computers Electrical isolation is provided on the Ethernet ports for increased reliability Please follow normal 10 100BaseT x wiring practices when installing the Industrial Ethernet Switch Main Ethernet Backbone ice grade switch EEEE E 2 eee ee ere Typical Industrial Industrial switch Ethernet Switch DL Installation E FACTORY FLOOR a Ethernet enabled lt YFE use Ndustria
9. This time stamp 1s used with the aging feature which will remove unused MAC addresses from the table after 300 seconds If a device moves the associated port on the switch will be changed migrated as needed Up to 1 024 MAC addresses can be stored and monitored at any time Auto sensing speed and flow control The RJ45 ports of the Industrial Ethernet Switch will auto negotiate with the connected device to determine the optimal speed 10 Mbps vs 100 Mbps and flow control for each port Automatic power saving If there 1s no cable on a port most of the circuitry for that port is disabled to save power Backoff operation The Industrial Ethernet Switch will drop a packet after 16 collisions Back pressure for half duplex The Industrial Ethernet Switch will apply back pressure when necessary with half duplex operation This back pressure will reduce congestion on busy networks Broadcast storm protection Broadcasts and multicasts are limited to 25 of the available bandwidth Buffering SRAM is used for buffering the messages There are 1024 128 bytes each buffers available Each port 1s allocated 205 buffers E SWOSU User Manual Page 11 of 13 Unmanaged operation The Industrial Ethernet Switch requires no supervisory processor to operate properly Flow control The Industrial Ethernet Switch automatically supports flow control frames on both the transmit and receive sides Forwarding The Industrial Ethernet Switch
10. ademarks Copyright 2001 All Rights Reserved Note All information in this document is subject to change without notice E SWOSU User Manual Page 4 of 13 Section 1 Overview Operation Performance Specifications Standards and Safety CE AN ZA A General Information This manual will help you install and maintain the Industrial Ethernet Switch This unmanaged switch is extremely easy to install and operate because little or no user configuration is required Once the Ethernet connections are made and the unit is powered up it will immediately begin to operate Unlike an Ethernet hub that broadcasts all messages out all ports the Industrial Ethernet Switch will intelligently route Ethernet messages only out the appropriate port The major benefits of this are increased bandwidth and speed reduction or elimination of message collisions and deterministic performance when tied with real time systems The Industrial Ethernet Switch supports both 10BaseT 10 Mbps and 100BaseTx 100 Mbps on its RJ45 ports Each of these ports will independently auto sense the speed allowing you to interface to regular or fast Ethernet devices Refer to Section 6 for more information on Industrial Ethernet Switch operation and features These general specifications apply to the Industrial Ethernet Switch Refer to Section 7 for complete technical specifications Ports 10 100BaseT x Shielded RJ45 Required Voltage 1
11. blication peut contenir des r f rences des produits fabriqu s ou offerts par d autres entreprises Les d signations des produits et des entreprises peuvent tre des marques de commerce et appartiennent exclusivement leurs propri taires respectifs Automationdirect com nie tout int r t dans les autres marques et d signations Copyright 2001 Automationdirect com Incorporated Tous droits r serv s Nulle partie de ce manuel ne doit tre copi e reproduite ou transmise de quelque fa on que ce soit sans le consentement r r err e M pr alable crit de la soci t Automationdirect com Incorporated Automationdirect com conserve les droits exclusifs l gard de tous les renseignements contenus dans le pr sent document E SWOSU User Manual Page 3 of 13 INSTALLATION AND HAZARDOUS AREA WARNINGS This switch should not be used to replace proper safety interlocking No software based device or any other solid state device should ever be designed to be responsible for the maintenance of consequential equipment or personnel safety In particular no responsibility for damages either direct or consequential that result from the use of this equipment in any application will be taken by the distributor of this product All power input and output I O wiring must be in accordance with Class I Division 2 wiring methods and in accordance with the authority having jurisdiction WARNING EXPLOSION
12. kets of different protocols simultaneously E SWOSU User Manual Page 12 of 13 Section 7 Technical Specifications Technical Here are the technical specifications for the Industrial Ethernet Switch covered by this manual Specifications 10 100BaseT x Ports 10 100BaseT x ports Protocols supported Ethernet compliancy Auto sensing operation Auto negotiating Flow control Ethernet isolation Plug and play Cable requirements Max cable distance Shielded RJ45 All standard IEEE 802 3 IEEE 802 3 Full and half duplex 10BaseT and 100BaseTX Automatic 1200 VRMS I minute S Twisted pair Cat 5 shielded recommended 100 meters oO Store and forward 1 4 Gbps Forwarding mode Memory bandwidth MAC addresses Address learning Address aging Address migration Backoff operation Back pressure Automatic Remove old address after 300s Automatic Drops after 16 collisions Automatic for half duplex Buffering Illegal frames Late collisions 205 buffers per port 128 bytes per buffer Dropped per 802 3 Dropped after 512 bit times lt Environmental terminal torque UL1604 CSA C22 2 213 Class 1 Div 2 Cenelec EN50021 Zone 2 E SWOSU User Manual Page 13 of 13
13. l Control Cabinet A VS Computer Ethernet Ethernet RJ45 Cable Type RJ45 Wiring Use data quality not voice quality twisted pair cable rated category 5 with standard RJ45 Guidelines connectors For best performance use shielded cable Please note that these cables are available as straight thru or cross over configurations The following 1s a guide for when to use each type Ethernet Switch Cable Type Ethernet Switch Cable Type STANDARD Port to to Use UPLINK Port to to Use Straight thru PC card Cross over Ethernet I O Straight thru Ethernet I O Cross over Straight thru PLC Cross over Other Ethernet enabled Straight thru Other Ethernet enabled Cross over devices devices Uplink port on another Straight thru Standard port on Straight switch or hub see note another switch or hub thru Note Some Ethernet switches and hubs have a settable switch on their Uplink port that will change how the port is internally wired Make sure this switch is set in the To Hub Switch MDI position as opposed to the To PC MDI X position Cross over Cable Wiring E SWOSU User Manual Page 9 of 13 Ethernet Connector Pin Positions Assignment TAi Ethernet Connector TX Su ses Cable Distance The maximum cable length for 10 100BaseT x is typically 100 meters 328 ft Refer to the following chart for some general guidelines Switch or Hub 100 meters 328 feet Switch or Hub PLC Ethernet I O PC etc 100 me
14. ntly strive to improve our products and services so we reserve the right to make changes to the products and or publications at any time without notice and without any obligation This publication may also discuss features that may not be available in certain revisions of the product TRADEMARKS This publication may contain references to products produced and or offered by other companies The product and company names may be trademarked and are the sole property of their respective owners Automationdirect com disclaims any proprietary interest in the marks and names of others Copyright 2001 Automationdirect com Incorporated All Rights Reserved No part of this manual shall be copied reproduced or transmitted in any way without the prior written consent of Automationdirect com Incorporated Automationdirect com retains the exclusive rights to all information included in this document E SWOSU User Manual Page 2 of 13 AVERTISSEMENT Nous vous remercions d avoir achet l quipement d automatisation de Automationdirect com Nous tenons ce que votre nouvel quipement d automatisation fonctionne en toute s curit Toute personne qui installe ou utilise cet quipement doit lire la pr sente publication et toutes les autres publications pertinentes avant de l installer ou de l utiliser Afin de r duire au minimum le risque d ventuels probl mes de s curit vous devez respecter tous les codes locaux et nationaux
15. supports store and forward mode It will forward messages with known addresses out only the appropriate port Messages with unknown addresses broadcast messages and multicast messages will get forwarded out all ports except the source port The Industrial Ethernet Switch will not forward error packets 802 3x pause frames or local packets Full Half duplex operation The RJ45 ports of the Industrial Ethernet Switch automatically support auto sense both full and half duplex flow control Illegal frames Illegal frames as defined by IEEE 802 3 will be dropped This includes short frames long frames and FCS error frames IEEE 802 3 compliant The Industrial Ethernet Switch strictly abides to the IEEE 802 3 standard for 10BaseT and 100BaseTX Ethernet communications Late collision If a packet experiences collisions after 512 bit times of transmission the packet will be dropped Plug and play This means that most functions or features of the Industrial Ethernet Switch are automatic and that there are minimal or no optional parameters that need to be set Just plug in your Ethernet cables apply power and the unit will immediately begin to operate Protocol independent The Industrial Ethernet Switch will work with all popular Ethernet protocols and networks such as TCP IP the Internet IP UDP NetBEUI IPX and many more It 1s compatible with all protocols that run over standard Ethernet IEEE 802 3 In fact it will support pac
16. ters 328 feet Note Hubs and Switches are different devices Hubs simply broadcast all messages out all ports Switches intelligently route messages only out the appropriate port All the devices described in this manual are Switches Full or Half The RJ45 ports will auto sense for Full or Half duplex operation No user configuration 1s Duplex necessary Operation E SWOSU User Manual Page 10 of 13 Section 6 Switching Features Switching Here s a brief explanation of the features found in the Industrial Ethernet Switch documented by Features this manual 10BaseT and 100BaseTx Autodetection Standard Ethernet 10BaseT has a maximum speed of 10 Mbps megabits per second Fast Ethernet 100BaseTx has a maximum speed of 100 Mbps The RJ45 ports on the Industrial Ethernet Switch automatically supports both types 1 4 Gbps combined bandwidth With full duplex and 100BaseTX communications each port can provide a full 200 Mbps of data throughput IK MAC addresses with automatic learning aging and migration Each Ethernet device inserts its unique MAC address into each message it sends out The port on the switch used for a given MAC address is automatically learned when a frame is received from that address Once an address is learned the switch will route messages to only the appropriate port instead of broadcasting messages out all ports like a hub A time stamp is also placed in memory when a new address 1s learned