1. ro Y Fill media Drain and Clean Note Please degas after filling media liquid Open reservoir cover in case hard to generate pressure Se vent valve 4 ones Remark 4 4 Unscrew with A Additel has made a concerted effort to provide hex wrench i i do mai complete and current information for the proper pen reservoir cover vent valve 4 Fill media NY use of the equipment The product specifications and other information contained this manual are subject to change without notice B Above pictures are just for reference n drain valve 6 Co 2 Collect media using a container Additel Corporation Jens www additel com
2. x 9 65 245 mm Weight 35 5 Ib 16 kg Views and Hydraulic Schematic 1 Reservoir shut off valve 2 Over flow reservoir 3 Positional Autoclave F 250 C 9 16 18UNF female n or customized female connector 5 ais 4 Reservoir cover vent valve 5 Reservoir 6 Liquid drain valve Hydraulic Schematic SY S 7 Pre pressurization shut off valve Le 8 High pressure Pressurization and fine pressure adjustment handle 9 Pre pressurization handle Troubleshooting Reservoir shut off valve 1 is not closed Close shut off valve 1 Pre pressurization shut off valve 7 is closed Open pre pressurization shut off valve 7 The media is not enough Fill more media and keep media level between 1 4 and 3 4 of the liquid reservoir filled Too much air in the pump Turn the handle anticlockwise to vacuum the pump open reservoir shut off valve 1 to have air released The pre pressurization shut off valve 7 is not closed completely Close pre pressurization shut off valve 7 Reference gauge or devices under test DUTs are not connected tightly Check connector replace the PTFE type re tight using a wrench The connector of DUT is not matched to connector Use proper adapter Close pre pressurization shut off valve 7 open reservoir shut off valve 1 turn pre pressurization handle Too much air in the pump 9 clockwise fully close reservoir shut off valve 1 and then open pre pressurization shut off v
3. Warnings and cautions Operate the pump in the rated pressure range 37 500 psi DO NOT over the safety pressure 40 000 psi When the system pressure is greater than 10 000 psi you must close the pre pressurization shut off valve 7 and then pressurize the system Always tighten the gauges using two wrenches Close all valves and handles of the pump and tighten the plugs on the connectors during transportation Always keep the reservoir cover vent valve 4 open during operation Do not over tighten the valves connectors and handles to avoid any damage Change media immediately if it is contaminated Keep media level between 1 4 and 3 4 of the liquid reservoir filled Keep the threads clean and lubricious and remove any dirt on threads Used by Trained Personnel only Any security problems or damages caused by incorrect operations are beyond Additel s responsibility Specification Pressure range 12 5 psi 0 85 bar vacuum to b 37 500 psi 2500 bar positive pressure 9 4 9 Remark Iflocal atmosphere pressure is 1 bar the vacuum can reach to 0 85 bar If local atmosphere pressure is P the vacuum can reach to P 85 bar Hydraulic Ultra High Pressure Test Pump User s Manual Temperature 5 50 C Version number 1306V01 Adjusting fineness 0 015 psi 1 mbar Safety pressure lt 40 000 psi Pressure media Diethylhexyl Sebacate Size Height 10 43 265 mm Base 20 71 526 mm
4. alve 7 4 valve is not open Open the 4 valve Step 1 Turn pre pressurization handle 9 clockwise fully close pre pressurization shut off valve 7 open reservoir shut off valve 1 Large cavity of DUT and pressurize the system too slow Step 2 Turn pre pressurization handle 9 anticlockwise fully close reservoir shut off valve 1 Step 3 Open pre pressurization shut off valve 7 pressurize the system Step 4 Repeat step 1 to 3 4 valve is not open Open the 4 valve Too tight in last operation Do not close shut off valves and handles too tightly Hard to turn pre pressurization handle 9 at high pressure It is normal Please use high pressure pressurization handle to increase reduce the pressure Lack of lubrication on threads Lubricate the threads Connection Note 4 Gauge positions are exchangeable If only one device under test DUT is connected the third connector on pump should be closed by a plug provided 2 Connect the gauges on pump by fingers tighten the connectors using two wrenches Z dial gauge pressure switch pressure transmitter flexible hose Pressurizing procedure Depressurizing procedure Note Skip step for dial gauge calibration in a narrow pressure range Sopen Maz U high ly N CLL A Wi R high pressure F LANN gt Es NZ 1 A y A LAN ressurizing f m R OW iq J Open to atmosphere Ventin Vacuum procedure and Zeroing

Download Pdf Manuals

image

Related Search

Related Contents

MEMORIAL DESCRITIVO ESC. ANTONIOG. PENIDO – Rev03  S.H.Figuarts ライダーマンマシン 取扱説明書  Philips 4000 series 47PFL4007H 47" Full HD Smart TV Black  Samsung GE89MST Εγχειρίδιο χρήσης  Symbol LS2208 製品取扱説明書  Benchmark Technical User Manual  PMA 7000B Installation Manual  Samsung SP-L331 Felhasználói kézikönyv  User Manual 1.2  PP150  

Copyright © All rights reserved.
Failed to retrieve file