1. programmer is full It is not possible to save any more parameter files If necessary delete parameter files you do not need anymore TRANSFER FAILED INVALID OPTION CFG Lenze LAC Tech EPM MISSING Error in the data transmission to the EPM PORT because the memory chip is defective or is not placed correctly in the PORT Exchange the defective EPM or plug the EPM correctly in the PORT Attempted MASTER gt EPM transfer when the memory size of the MASTER EPM is different from that of the target Replace the EPM in the EPM PORT with an EPM of the same color as the Master Error in the data transmission to the EPM PORT because of an internal error in the EPM programmer Attempted to CREATE a new file from a servo drive EPM in the MASTER PORT Attempted to EDIT a non servo EPM or corrupted servo Attempting to EDIT DELETE or CREATE a file but there are no stored files in the EPM Programmer Attempt to LOAD CFG EPM without a valid configuration EPM in the MASTER PORT ENGLISH Please contact your Lenze representative Only inverter drive EPM s can be saved as files in the EPM Programmer Replace the EPM in the EPM PORT with a valid servo EPM Insert a configuration EPM into the MASTER PORT 21 For Sales and Support Contact Walker EMD gt Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 www walkeremd com Notes
2. 22 ENGLISH lenze For Sales and Support Contact Walker EMD gt Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 www walkeremd com For Sales and Support Contact Walker EMD gt Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 www walkeremd com AC Technology Corporation 630 Douglas Street Uxbridge MA 01569 USA Sales 800 217 9100 Service 508 278 9100 www actech com For Sales and Support Contact Walker EMD gt Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 www walkeremd com
3. 876 4444 Tel 203 426 7700 Fax 203 426 7800 www walkeremd com 4 7 Copy from one EPM to another EPM With this function it is possible to copy a parameter file directly from one EPM a to another EPM Plug the EPM containing the parameter file you want to copy into the MASTER PORT Plug the EPM to which you want to copy the parameter file into the EPM PORT Press The display shows Explanation 1 MASTER gt Press the key until the menu appears in the display 2 DEFAULTS 400 gt gt The name of the parameter file e g DEFAULTS of the EPM in the MASTER PORT is displayed The parameter version of the file is shown in parenthesis 0 TRANSFERRING 0 The parameter file is copied or TO EPM e E 9 3 DAT 400 EPM 312 if the parameter version of the file does not correspond with the parameter version of the EPM in the EPM PORT CONFIRM ENTER security check takes place concerning the existing data on the EPM Press the ENTER key to overwrite the existing data Press the MENU key if you want to abort the process 4 TRANSFERRING 100 The parameter file will be copied TIDEFAULTS 400 5 MASTER gt EPM Returns to the main menu Tip The file name on the MASTER EPM is only displayed if the user parameters exactly match the OEM Default parameters 71566 Section 1 3 EPM Technology and Operation f the
4. NEW FILE ENGLISH The EPM programmer automatically returns to the main menu Lenze LAC Tech For Sales and Support Contact Walker EMD gt Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 www walkeremd com Operation 4 12 Delete a file stored in the Programmer With this function you delete the parameter files stored in the EPM Programmer Press The display shows Explanation 1 DELETE FILE Press the key until the menu appears in the display 2 SELECT FILE his request is briefly shown in the display IDEFAULTS 400 lt he cursor is blinking in the display on the right 3 A v 6 400 lt Select the parameter file you want to delete e g aha a 4 CONFIRMZ ENTER Press the MENU key if you want to abort the process 5 DELETING FILE he parameter file is deleted FILE DELETED DELETE FILE he EPM programmer automatically returns to the main menu 4 13 Change EPM Programmer Internal Configuration With this function you can change the type of files that the EPM Programmer can EDIT by downloading the proper configuration for the file you will be working with from a Configuration EPM loaded in the MASTER PORT Press The display shows Explanation 1 LOAD CFG Press the key until the menu appears in the display 2 VERIFYING MASTER The programmer verifies that the EPM in the MASTER PORT is a valid Configuration EPM CONFIRM ENTER Press the ENTER button to conf
5. higher value Menu level Select submenu file v Parameter level Enter a lower value Switch on off background illumination for the display TO EM Copy data to EPM PORT 8 ENGLISH lenze For Sales and Support Contact Walker EMD gt Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 www walkeremd com Operation 4 3 Switch on off EPM Programmer Switch on with unprotected access without password Press The display shows Explanation 1 PROGRAMMER 2 INTERN CFG 400 Shows the parameter version that the EPM programmer is configured with e g 400 3 Shows the parameter version of the EPM e g 400 MASTER CFG 400 plugged into the MASTER PORT 4 Shows the name of the parameter file e g MSTFILE DEFAULTS DEFAULTS stored in the EPM plugged into the MASTER PORT This message is displayed if no EPM is plugged MASTER MISSING into the MASTER PORT Switch on with protected access with password Steps 1 4 as above 1 Section 4 16 Enter change password Press The display shows Explanation 5 The cursor is blinking in the display on the right PASSWORD 0008 Enter the password using the AW buttons If you do not enter a password you have restricted PASSWORD xxxx access to the main menus after confirmation only the menus CONTRAST DISPLAY and MASTER gt EPM are available If you enter a wrong password WRONG PASSWORD will be displayed If you press
6. power 7 3 8 4 Olbpertation rini eterni aine zesa seinen erus 4 1 Overview of operating elements 42 KeyFunctions 4 3 Switch on off EPM Programmer 44 Select Language 45 Switch on off display background illumination Le ICR stern a pas 4 7 Copy from one EPM to another EPM 48 Copy a file stored in the Programmer to an EPM 49 Edit the EPM 4 10 Edita file stored in the Programmer 4 11 Create new file 4 12 Delete a file stored in the Programmer 4 13 Change EPM Programmer Internal Configuration 4 14 Contrast setting 4 15 Display status messages 48 Entenchange PassWord 5 Troubleshooting rosis indio kata nun nuu iu gr inna nra E do Ra Ra 20 20 lenze ENGLISH 1 For Sales and Support Contact Walker EMD gt Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 www walkeremd com Preface and general information 1 Preface and general information The EEPM1RA EPM programmer enables you to easily duplicate and archive the memory and configuration of inverter drives and servo controllers that utilize the EPM feature The EPM programmer enables you to copy the contents of one EPM to another EPM read out contents of EPMs and save them to a PC or the EPM programmer as files edit files stored in the EPM programmer store edited files under anothe
7. the MENU key the process is aborted and you have only restricted access to the main menus see Section 4 16 If you have forgotten your password please contact your Lenze representative 20 ENGLISH Lenze LAC Tech For Sales and Support Contact Walker EMD gt Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 www walkeremd com Troubleshooting and fault elimination Display MASTER DAMAGED The EPM in the MASTER PORT is defective Press the menu key to return to the main menu Plug an EPM in the MASTER PORT The EPM is not placed correctly in the MASTER PORT he message does not indicate an error but only serves as a note he message is only displayed for a short time MASTER MISSING Seen on power up if there is no EPM in the MASTER PORT nformation only Programmer is trying to read data from the MASTER PORT but cannot detect an EPM in this PORT a valid EPM into the MASTER PORT INVALID MASTER he EPM you are attempting to read in he MASTER PORT is defective or 5 no valid data he EPM in the MASTER PORT is a onfiguration EPM Press the menu key now to return to the main menu Exchange the EPM in the MASTER PORT A Configuration EPM cannot be copied NAME EXISTS he file name you want to allocate to a parameter file already exists Select another file name MEMORY FULL he internal memory of the
8. EPO1E en Lenze CEN Operating Instructions mmm 001 EPM Programmer EEPMTRA For Sales and Support Contact Walker EMD gt Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 www walkeremd com 2004 Lenze gmbH 8 00 KG No part of this documentation may be copied or made available to third parties without the explicit written approval of Lenze GmbH amp Co KG All information given in this documentation has been carefully selected and tested for compliance with the hardware and software described Nevertheless discrepancies cannot be ruled out We do not accept any responsibility nor liability for damages that may occur Any necessary corrections will be implemented in subsequent editions For Sales and Support Contact Walker EMD gt Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 www walkeremd com Contents 1 Preface and general information 2 1 1 About these Operating Instructions 12 Terminology used 1 8 EPM Technology and Operation 14 Pictographs used in these Operating Instructions 1 5 Scope of delivery 2 Technical data 2 1 General data and application conditions 22 Electrical Data 2 3 5 Battery Operation 3 1 Changing Batteries 3 2 Operation with external
9. ORT Press The display shows Explanation 1 CREATE NEW FILE Press the key until the menu appears in the display 2 ENTER FILE NAME This request is briefly shown in the display NAHE nn The cursor is positioned under the first character of the file name A file name can consist of 8 characters maximum 3 Use the AW buttons to select value To scroll quickly to a value keep the key pressed The scroll rate increases as you hold the button 4 The cursor is positioned under the next character of the file name 5 _____ Repeat step 3 until the desired name is entered 6 NAME _____ Press ENTER until the cursor is positioned on the eighth character position If you re press ENTER the file name is stored COPY DATA FROM Press MENU at any time to abort the file creation and return to the main menu 7 4 v 1 FI The cursor is blinking the display on the right Select a source e g FILE whose parameters you want to copy into your new file 1 FILE 2 MASTER 8 SELECT FILE this message is not displayed when selecting MASTER and steps 8 and 9 are skipped gt DEFAULTS 4008 lt The cursor is blinking in the display on the right 9 gt ABC__ 400 lt Select a parameter file you want to copy e g ABC___ Press the MENU key if you want to abort this proceedure 10 TRANSFERRING 100 The new file has been created 16 FILE CREATED CREATE
10. e parameter NETWORK ADDRESS Stores the new value onto the EPM ENTER EDIT EPM Returns to the main menu MENU 1 The only be edited if the configuration of the Programmer and the parameter version of the EPM are identical See section 4 13 for changing the configuration of the EPM Programmer 14 ENGLISH lenze For Sales and Support Contact Walker EMD gt Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 www walkeremd com 4 10 Edit a file stored in the Programmer With this function it is possible to edit an Inverter Drive controller parameter file stored in the EPM programmer Press The display shows EDIT FILE SELECT FILE gt DEFAULTS 400 lt ABC 4008 FILE NAME 4 M0P SAVED FREQ or KEYPAD SPEED A DIRECTION EIX PARAMETER EDIT FILE Operation Explanation Press the key until the menu appears in the display This request is briefly shown in the display The cursor is blinking in the display on the right The file name of a parameter file e g DEFAULTS is displayed Select the parameter file you want to edit The cursor is blinking in the display on the left The first entry which can be edited is displayed e g DATA FILE NAME Press ENTER to edit the file name Use AV buttons to change letters Use ENTER to move to next letter Pressing ENTER at the last character st
11. er is displayed The cursor is blinking in the display on the right Select the parameter file you want to copy 6 0 The parameter file is copied if the parameter version of the file does not correspond with the parameter version of the EPM in the EPM PORT security check takes place concerning the existing data on the EPM Press the ENTER key to overwrite the existing data Press the MENU key if you want to abort the process The parameter file will be copied Returns to the main menu 13 For Sales and Support Contact Walker EMD gt Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 www walkeremd com 4 9 Edit the EPM This menu item is only displayed when the Programmer is configured for a Servo product With this function it is possible to edit BAUDRATE NETWORK ADDRESS CAN NODE ID and CAN BAUDRATE for Model 94 Servo drives Press The display shows Explanation 1 EDIT EPM Press the key until the menu appears in the display 2 EPM INFO This request is briefly shown in the display 16384 gt The EPM parameter version is displayed CAN NODE ID Displays the parameters that can be edited ENTER 3 A v NETWORK ADDRESS Select the parameter file you want to Edit NETWORK ADDRESS is shown as an example 4 NET ADDR 3H The cursor is blinking in the display on the right A v NET ADDR Change th
12. es not contain the selected language English will be displayed 4 5 Switch on off display background illumination Press The display shows Explanation 1 The background illumination is switched on LIGHT 2 The background illumination is switched off LIGHT 1 f you operate the EPM programmer with a power supply unit the background illumination will always be switched on 10 ENGLISH lenze For Sales and Support Contact Walker EMD gt Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 www walkeremd com Operation 4 6 Menu Overview After power is switched on and the initialization screens have been displayed the primary functions of the EPM Programmer accessed by pressing the MENU button MASTER gt EPM SECTION 4 7 MENU FILE gt SECTION 4 8 MENU EDIT EPM SECTION 4 9 servo config only MENU EDIT FILE SECTION 4 10 MENU CREATE NEW FILE SECTION 4 11 MENU DELETE FILE SECTION 4 12 MENU LOAD CFG EPM SECTION 4 13 MENU DISPLAY CONTRAST SECTION 4 14 MENU MISCELLANEOUS SECTION 4 15 MENU 1 When copying to an EPM using MASTER gt EPM or FILE gt EPM all data on the target EPM will be overwritten ENGLISH 11 For Sales and Support Contact Walker EMD gt Toll free 800
13. et is not used 1 4 Pictographs used in these Operating Instructions Pictograph used Signal words Stop Warns of possible malfunctions of the EPM Programmer due to electrostatic discharge ESD e Tip Designates a general and useful note If observed it will make using the 1 EPM Programmer easier 1 5 Scope of delivery Scope of delivery Important e 1 EPM programmer with 4 batteries already After receipt of the delivery check immediately whether installed the items delivered match the accompanying papers e 1 Operating Instructions Lenze does not accept any liability for deficiencies claimed subsequently Claim Visible transport damage immediately to the forwarder visible deficiencies incompleteness immediately to your Lenze representative lenze ENGLISH 3 For Sales and Support Contact Walker EMD gt Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 www walkeremd com Technical data 2 Technical data 2 1 General data and application conditions Field Values Type of Protection IP20 Permissible temperature ratings Operation 0 50 Transport 20 60 C Storage 20 60 C Humidity lt 85 without condensation Weight 1 3 kg with batteries Applied Standards Noise emission to EN 50081 2 1993 Noise immunity to EN 61000 6 2 1999 Approvals UL 508C Underw
14. irm this action 3 TRANSFERRING 0 100 The new configuration is loaded into the EPM Programmer s memory and verified 4 WAIT LOADING CFG Messages are displayed briefly then the EPM CFG LOADED automatically returns to the main LOAD CFG EPM Changing the EPM Programmer s internal configuration is only required if you are going to EDIT an inverter drive file stored in the EPM Programmer or EDIT a servo drive EPM The Programmer must be configured for the parameter version of the file Configuration EPM s can be purchased from Lenze AC Tech or your local distributor Configuration files can be downloaded into the EPM Programmer from your PC via RS232 connection using TECHLINK software lenze ENGLISH 17 For Sales and Support Contact Walker EMD gt Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 www walkeremd com 4 14 Contrast setting With this function you can adjust the viewing angle for the EPM Programmer display Press The display shows Explanation 1 DISPLAY CONTRAST Press the key until the menu appears in the display 2 CONTRAST MEDIUM The currently set value is indicated e g MEDIUM 9 CONTRAST MEDIU The cursor is blinking in the display on the right 4 CONTRAST XXXXX Select the setting wanted CONTRAST LOW CONTRAST MEDIUM CONTRAST HIGH 5 CONTRAST LOW The setting selected e g LOW is accepted The cursor stop
15. ogrammer 007 Open the battery compartment of the programmer 1 Remove the 5 screws on the bottom of the EPM programmer 2 Remove the EPM Programmer base plate carefully v T y om 1 aed epm004 Insert the batteries into the battery compartment 1 Insert the batteries into the battery compartment as shown in figure above Pay attention to the correct polarity of the batteries 2 Replace the base plate carefully and secure the housing with the 5 screws Lenze 6 ENGLISH lenze For Sales and Support Contact Walker EMD gt Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 www walkeremd com Commissioning 6 n ON 3 3 Operation with external power supply Stop 4 Avoid electrostatic discharges ESD at the connector for the voltage supply EPM programmer malfunction may occur Take appropriate measures to avoid electrostatic conditions Occasionally occurring malfunctions can normally be remedied by switching the EPM Programmer off and then on again It is also possible to operate the EPM programmer with an external power supply Power supply output data Output voltage 6 VDC stabilized Output current 300 mA Power supply connector plug details For connections to the EPM programmer the power suppl
16. ores the name press MENU to abort This parameter sets the initial run speed when the speed source is either MOP or KEYPAD Press ENTER to access and AW to adjust Selects default direction for the motor when controlled by a remote keypad Sequence through the parameters available for the configuration loaded into the programmer Press ENTER to edit the parameter Use AV buttons to change selection or value Press ENTER to store the new value or press MENU to abort Returns to the main menu 1 Lenze Tip The parameter file DEFAULTS is write protected f you want DEFAULTS to be the basis for editing create copy of this file see section 4 11 A file can only be edited if the configuration of the EPM Programmer and the parameter version of the file shown in parenthesis are identical If these two are not the same this will result in the error message FILE VER INCOMP See section 4 13 for changing the configuration of the EPM Programmer ENGLISH 15 For Sales and Support Contact Walker EMD gt Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 www walkeremd com 4 11 Create a new file With this function you create a new parameter file in the EPM programmer Data for your new file can be copied from the following sources Parameter files available on the EPM programmer Parameter file from an EPM mounted in the MASTER P
17. ou can only edit a file if the parameter version corresponds to the configuration file of the EPM programmer See Section 4 13 on changing the programmers internal configuration READ ONLY FILE You have tried to edit or delete the file DEFAULTS The file DEFAULTS cannot be edited or deleted sufficient memory for the file you are attempting to copy EPM DAMAGED The EPM in the EPM PORT is Exchange the defective EPM defective The EPM is not placed correctly in the Plug the EPM correctly in the PORT EPM PORT EPM MISSING There is no EPM in the EPM PORT to Press the menu key now to return to which you are attempting to transfer the main menu data or edit Plug an EPM the PORT EPM TOO SMALL EPM in EPM PORT does not have Replace the EPM in the EPM PORT with an EPM that has a higher memory capacity INTERNAL ERROR Internal device error Please contact your Lenze representative INVALID INT CFG The configuration file of the EPM programmer is invalid Attempting to reconfigure the EPM programmer without a valid configuration EPM Please contact your Lenze representative Insert a valid configuration EPM into the MASTER PORT See section 4 13 WRONG PASSWORD The access protection is activated and you have entered the wrong password after switch on Only if you enter the correct password will you have full access to the main menus If you press
18. r file name and create new files copy files stored in the EPM programmer into EPMs 1 1 About these Operating Instructions This documentation applies to the EPM Programmer as of version B Lenze ceris For detailed nfdrmation refer to instructior nual EP O1x Made in USA SVDC 150mA min EEMPIRA EPM Programmer Power Supp y DRA FRIWO 7207 06 15 0791 15 6 0 ES epm0i0 A Type 1 B Hardware version 1A Software version 10 These Operating Instructions are designed to ensure safe and trouble free working with the EEPM1RA programmer Before you start working with the EEPM1RA EPM programmer please read the Operating Instructions carefully and follow the notes These Operating Instructions must always be kept as a complete legible document 1 2 Terminology used Term Meaning in this document Drive controller Lenze AC Tech submicro frequency inverter Servo controller Lenze AC Tech SimpleServo PositionServo 2 ENGLISH Lenze For Sales and Support Contact Walker EMD gt Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 www walkeremd com Preface and general information 1 3 EPM Technology and Operation The EPM uses EEPROM technology housed in a removable plastic od casing for protection and ruggedness A removable memory BLS structu
19. re as provided by an EPM include Programming a drive without power Easily duplicate proven programs using the EPM Programmer Reduce down time and troubleshooting The EPM feature is included with several Lenze and AC Tech inverter drive controllers and in the new SimpleServo products Operation and some functionality differ between the Drive and Servo product lines m PM Color Blue PM files can be stored in EPM Programmer Drive Controllers m m Servo Controllers PM Color Blue Model 94 PM files cannot be stored in EPM Programmer m OEM Defaults The EPM when used in Inverter Drive Controllers actually contains two sets of drive parameters The USER memory is the memory the drive typically uses for operation and is actually the drives operating memory that can be accessed and changed from the front of the drive a remote keypad or serial communications The OEM Default values can only be written by the EPM Programmer and cannot be altered through normal drive operation or programming This provides a benefit in that an OEM using the EPM Programmer to quickly copy the drive configuration actually ships the drive with their own Factory Defaults Lenze Servo Controllers are programmed using MotionView94 Software via serial link with a PC Field reprogramming from the front of the controller is not possible As such resetting to OEM defaults is impossible and this second memory s
20. ress The display shows 16 MISCELLANEOUS 2 B W VERSION X XX 3 BlAsSWwORD 0000 4 PASSWORD 000 5 PASSWORD 6 BASSWORD XXXX 7 MISCELLANEOUS Lenze LAG Tech ENGLISH Operation Explanation Press the key until the menu appears in the display akes you to the submenu The cursor is blinking in the display on the left Displays the set password for the access protection Factory setting 0000 When the password is set to 0000 the access protection is deactivated he cursor is blinking in the display on the right Enter a password Any value between 0000 and 9999 Use the AW buttons to select a value To scroll quickly to a value keep the key pressed The scroll rate increases as you hold the button The cursor is blinking in the display on the left The new password has been stored Returns to the main menu 19 For Sales and Support Contact Walker EMD gt Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 www walkeremd com 5 Troubleshooting 9 1 Error messages Display Troubleshooting and fault elimination CHANGE BATTERY The battery voltage is 3 6V the message is displayed after switching on the EPM programmer Change the batteries See Section 3 2 FILE VER INCOMP The parameter file or servo you are attempting to edit has a different parameter version than the configuration file of the EPM programmer Y
21. riters Laboratories Power Conversion Equipment Conformity CE EMC Directive 89 336 CEE 2 2 Electrical Data Field Values DC Voltage Supply 6 VDC min 150 mA Internal Batteries 4 mono cells type D 1 5 VDC each External power supply unit 6 VDC 300 mA Display ype LCD Display format Text Lines x characters 1x16 Contrast setting Via menu Memory Data Memory up to 120 parameter files for inverter drive controllers Serial Interface DB9 Connector RS232 4 ENGLISH Lenze For Sales and Support Contact Walker EMD gt Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 www walkeremd com Technical data 2 3 Dimensions 4 Lm d ET 9855888858888588 d d Bet T 5 Ll 1 155 g 76 001 Dimensions mm lenze ENGLISH 5 For Sales and Support Contact Walker EMD gt Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 www walkeremd com Commissioning 3 Commissioning 3 1 Battery Operation The EPM programmer is immediately ready for operation It is delivered with 4 batteries 1 5 V mono cells 3 2 Changing Batteries For battery operation you need four mono cell D size with 1 5V each In order to access the battery compartment you must open the housing of the EPM pr
22. s blinking 6 DISPLAY CONTRAST Returns to the main menu 4 15 Display status messages With this function you can set the Programmer s password and view other important information Press The display shows Explanation 1 MER MISCELLANEOUS Press the key until the menu appears in the display 2 B w VERSION X XX Takes you to the submenu The software version e g 1 00 of the EPM programmer is displayed 3 With the AW you can select the status messages 4 INTERN CFG 400 Shows the parameter version that the EPM programmer is configured for 9 400 5 ii LES 1 Indicates the number of parameter files saved in the A EPM programmer 6 BATTERY 5 8VDC Displays the current voltage level of the 4 internal batteries To guarantee safe operation the battery voltage must not fall below 3 6 VDC 7 BASSWORD 0000 Displays the set password for the access protection A Lenze setting 0000 entering and changing the password is described in the next section 8 MER MISCELLANEOUS Returns to the main menu 18 ENGLISH For Sales and Support Contact Walker EMD gt Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 www walkeremd com 4 16 Enter change password When a password has been set only the main menus can be accessed until the correct password has been entered MASTER lt EPM DISPLAY CONTRAST MISCELLANEOUS without the submenu PASSWORD P
23. the MENU key you abort the process and get the restricted access to the main menus Tip After the initialization the main menu shown last is automatically called up f you lose or forget your password please contact your Lenze representative Hio Switch off Press The display shows Explanation The shutdown process takes 5 seconds SHUTDOWN 5SEC If you press any key within these 5 seconds the shutdown process is aborted e Tip 1 The EPM programmer automatically turns off after 5 minutes if operation takes place during this time lenze ENGLISH 9 For Sales and Support Contact Walker EMD gt Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 www walkeremd com 4 4 Select Language You can choose between English German French Italian and Spanish languages The language change over can be carried out on the menu level and parameter level The language set remains stored even after switching off the EPM Programmer Press The display shows Explanation 3 Press and hold the ON button The languages will scroll in 5 second intervals in the sequence English German French Italian Spanish Release ON button when desired language is displayed 1 Languages are part of the product Configuration File If when changing the internal configuration section 4 13 the new configuration file do
24. user and OEM memory areas do NOT match the name of the parameter file of the EPM in the MASTER PORT will be displayed as fF 400 This indicates that the user parameters have been changed from the OEM defaults or the Factory Defaults Copy from MASTER gt EPM will copy only the user parameter file from the MASTER and save this to both the user and OEM memory locations of the EPM in the EPM PORT The parameter file name of the new EPM will be Servo controllers do not store OEM defaults so the parameter file name in the master will always be displayed as 16384 lt 12 ENGLISH For Sales and Support Contact Walker EMD gt Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 www walkeremd com Operation 4 8 Copy a file stored in the Programmer to an EPM With this function it is possible to copy a parameter file saved in the EPM programmer to an EPM Plug the EPM to which you want to copy the parameter file into the EPM PORT Lenze The display shows FILE gt EPM 5 400 gt gt HDEFAULTS 4008 gt gt 400 gt gt TRANSFERRING 0 DAT 400 EPM 312 CONFIRM ENTER TRANSFERRING 100 400 gt gt FILE gt EPM ENGLISH Explanation Press the key until the menu appears in the display The stored name of a parameter file e g DEFAULTS stored in the EPM programm
25. y unit requires an extra low voltage plug with the following 6 VDC dimensions 2 1 5 5 x 9 5 mm 005 Connect the power supply unit Lenze wre semra 6 9 For deta led formation refer Made in USA DC 150m min Programmer 5 1410 ma ni MPP 006 Plug the extra low voltage plug of the power supply into the connector at the back of the EPM Programmer lenze ENGLISH 7 For Sales and Support Contact Walker EMD gt Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 www walkeremd com 4 Operation 4 1 Overview of operating elements Display MASTER PORT Plug in station for EPM from which the data is to be read EPM Port Plug in station for memory chip on which the data is to be written Operator Keypad 001 4 2 Key Functions Key Level Function ON Switch on EPM programmer OFF Switch off EPM programmer Menu level Select menu quit submenu MENU Parameter level Return to the main menu without saving changes Menu level Select submenu execute menu command ENTER Parameter level Select parameter to enter a value accept a value entered pomo Menu level Select submenu file A Parameter level Enter a
Download Pdf Manuals
Related Search
Related Contents
DEPRO AGROFER 14 MANUAL DE USUARIO - Gobierno de la Provincia de Córdoba BILL STUMP G2K Day Night Cam OmniSwitch AOS 6 Switch Management Guide - Alcatel Egg Boiler - Clas Ohlson Sevin 100047720 Instructions / Assembly Samsung VLUU L100 User Manual Manual do Usuário Techno-Solis inc. - Techno Solis USA warning - Jacobsen Copyright © All rights reserved.