Home
EUREKA FORBBES WATER PURIFICATION
Contents
1. Eureka Forbbes Water Purification System Remedy Turn on feed water Open tank valve Change or realign O ring Wrap the thread with Teflon tape and tight evenly and firmly Realign and cut the tube Sanitize the tank Change pre filter cartridge first If bad tasting condition persists replace the membrane Change pre filters amp check pump output pressure which should be about 80 100 psi Replace the brine seal Replace the membrane Pump air pressure in the tank up to 8 psi Change check valve or replace the membrane Replace the O ring Check and replace the cartridge Check and replace the solenoid valve Adjust low pressure switch to 10 psi setting Replace the pump Replace the transformer Change the filter or adjust low pressure switch to 10 psi setting Set high pressure switch to 40 psi setting 11 7 Stage Reverse Osmosis System SYSTEM OPERATION First time Operation 1 Plug in the power supply Allow several minutes for the system to flush and fill 2 Do not drink the first tank of water About one to two hours after the system has started turn on the faucet and drain the first tank full of water completely When Abnormal Conditions Occur 1 Shut off the system Unplug power supply and then turn off feed water adapter valve 2 Call authorized service centre of distributor Before calling please try your best to determine exactly the problem you have countered by refe
2. Diagram Microscopic enlargement portion of R O Membrane to show the filtration pattern across it Eureka Forbbes Water Purification System R O PROCESS DIAGRAM DIAGRAM 1 DIAGRAM 2 PI Water Energizer 24 Eureka Forbbes Water Purification System 5 Water Polishing In line Carbon Filter Cartridge Unit Treatment water is further polished and purified in the 5th stage just before it is drawn for drinking or cooking purpose Cartridge type Taste and odor removal and polishing Replacement cartridge i GACIOROD So Safe PRODUCS Enlargement of Activated Carbon Granule to show the absorption of organic pollutants on it DIAGRAM Eureka Forbbes Water Purification System SYSTEM CONTROLLERS 1 Automatic Flush Restrictor 2 Electronic Shut off Valve 3 Tank Level Controller 4 Low Pressure Switch 5 Tank Shut off Switch 6 Pressure Booster Pump 7 High pressure Switch POWER SUPPLY Input Single phase 220 VAC 50 Hz 110 also available Output DC 24V 1 2A WATER TREATMENT PARAMETERS Water Treatment Capacity 50 GPD Feed Water parameters Turbidity i 5 NTU max Chlorine Levels 0 5 PPM max Temperature Range i 100 F 38 C Line Pressure Range 10 to 40 psi Total Dissolved Solids 2000 ppm max Eureka Forbbes Water Purification System TREATMENT EFFICIENCY RESULTS Rejection Solute Bicarbonate HCO3 95 96 Sodium Na 9
3. and others We strive to improve the quality of life and the environment and durable and innovative p r o d u c t S Eureka Forbbes Water Purification System Dear Valued Customer Congratulations You are now the owner of worlds finest water purification unit manufactured by Eureka Forbbes Water Technologies a world leader in the water purification industry We take pride in our solid reputation for product quality and industry proven performance We are certain that your decision to own Eureka Forbbes Water Purification System will go a long way towards keeping you and your family in good health With the scarcity of water and increase in water pollution problem it is hard nowadays for one to rely on conventional source of water supply More and more people are looking for reliable water treatment systems which can tackle ever increasing known and unknown pollutant problems in water and procure safe water We are confident that you will be satisfied with its working and that it will serve your needs for safe supplies for a long time It is worth mentioning here that water from Eureka Forbbes Water Purification System has been designed keeping the above in mind and can be used not only for drinking and cooking needs but also for a number of other requirements as well You can use treated water to prepare you baby s feed wash vegetable and fruits and for many more purposes This manual tells you about Eureka Forbbes Water Puri
4. in industry it makes possible a better preparation of water with less chemical substances and energy 13 Pi Water energizer Pi water is water which is extremely similar to water in living body and it is induced from very small quantity of iron ferric furious ions in their excited state System This system employs multiple unique layers of filtration combined with magnetism It is filtration includes coral reef coral sand natural active calcium BCS ceramic and power full magnet The cluster chains of the H2O are also reducing It NMR from 128 Hz to reduce it become 53 Hz Procedure Cartridge of for pi water is divided in three parts in first part is of coral reef second is of coral sand third is of bio ceramic which have highly magnetic charge The passage of flowing water through coral sand and reef and from ceramic balls energizes it Benefits Promotion for adaptability Enhance the larger scope of application for temperature and light Purification of environment Improve the quality of bad water and soil Normal growth Improvement of living body functions Improve various body functions Obtaining regeneration ability Helps and restore the damages cells and tissue Inhibition of harmful ions Metal ions Inhibition of Pathogenic Organisms Proliferations Stops viruses Promotion of growt 19 Eureka Forbbes Water Purification System Auto Flushing System Low Pressure Switch High Pressure Switc
5. the membrane surfaces In order to avoid such a situation the system should be flushed with low pressure water at high velocity so as to ensure that no salt deposits are formed on the membrane surfaces during the period when the plant in not operating The flushing operation provided in the system is automatic and is carried out every time plant stops or starts during automatic operation mode More over A manual button is also provided on control panel for any time additional flushing if required Manual Flush button to flush the membrane immediately Press the Manual Flush to flush the membrane immediately to keep its best RO performance This function can be used when you exchange the pre cartridge filter and want to flush the pre carbon before using the water for food or drinking Indicators shows how it works Tank Full System Flush Pump working Manual Flush and membrane change indications make it easy to control the RO system and help the user to understand the RO system and will warn the user if operation is affected for any reason 21 Eureka Forbbes Water Purification System Sediment filter he e Dual Booster Se E en Pup Pump ilter Hydronc Vitalizer a Reverse 2222 Osmosis Ultra Violet Sterilizer Pi water energizer Drain Faucet STAGES OF WATER TREATMENT 1 Pre filtration removal of sediments 2 3 Purification taste and odor removal double treatment in 2 stages 4 Desalinati
6. 0 Ppm Nitrates plus 10 00 as N ppm Lead 0 015 Ppm Nitirites 1 00 ppm Boron 1 00 Ppm Selenium 0 01 ppm Cadmium 0 01 Ppm Silver 0 05 ppm Chromium Hexavalent 0 05 Ppm Zinc as Zn 5 00 ppm Copper 1 00 Ppm Strontium 10 0 pc L Less than Eureka Forbbes Water Purification System 10 Symptoms No water production Less water production Leaking filter housing or membrane vessel Leakage at threaded connection Leakage at tubing Bad tasting water High TDS in products water Nominal or no purified water flow from the faucet Pump functioning but not producing purified water Pump not functioning Abnormal cycling of pump Abnormal shutdown or pump after short while TROBLESHOOTING Causes Feed water shut off low pressure Tank valve closed Defective or misaligned O ring Connection nut loosen or not properly tightened There is a bend in the tubing Tank contaminated Pre filters of membrane fouled Cross membrane pressure is too low Brine seal on membrane is leaking Membrane has expired Loss of air pressure in the tank Check valve failed or membrane fouled Valve stucks at O ring Pre filter carbon clogging Water inlet solenoid valve failed cartridge Low water supply pressure High low pressure switch not working Burnt boosting pump Burnt transformer Pre filter clogging or low feed pressure Inadequate high pressure switch setting
7. 5 97 Fluoride F 95 96 Chloride C1 95 97 Silicate S102 95 97 Nitrate No3 93 96 Magnesium Mg 96 98 Nickel Ni 98 99 Copper Cu 98 99 Urea 40 60 Glucose 99 Sucrose 99 Bacteria s amp Viruses 99 27
8. 7 Stage Reverse Osmosis System EUREKA FORBBES WATER PURIFICATION SYSTEM AQUA GAURDrrss OWNER S MANUAL N Third Generation Reverse Osmosis System for Prime Quality Water Eureka Forbbes Water Purification System TABLE OF CONTENTS Introduction sisi sr et eiie Aen en 02 Installation Instruction 2 ertet eter eI ea nenn 03 Start up of the Purification ss essensen nennen nennen enne 04 Answer to Some Questions You May Have on the Potability of Water 06 Recommended Procedures for Water Testing esee 08 Recommended Test for Waste Analysis eres 08 Standards for Potable W ter au 0 n2 2 80 8822 09 Trouble Shooting aaen t ihe HERE e eine age 10 System Operation tee Cds ie eles a eee Ede EO Le ete Sates 12 System Maintenance i ettet e eeu enu 13 System Flow Chart ute eere oe E e HR Ride 14 Stages Of Water Treatment caede de i eese ind 15 Replacement Components Cartridges eese 15 Reverse Osmosis Process 1 isd Lett ee be td etes 17 System Controllers dad e e eee an RU TE eaten ose 19 POWer SUPPLY nne ernennen Rare 19 Water Treatment Parameter eese nennen nennen trennen 19 Treatment Efficiency Result eren 20 We Care About the Water You Drink esee eene 21 Mission of Eureka Forbbes is to be respected company world wide Dedicated to serve and supply water purification products to individual industries
9. Do not use the appliance where the water is microbiologically unsafe or the TDS level is above 2 000 ppm Use the unit with cold water only Water Temperature Do not filter water with temperature higher than 38 C Water Pressure Do install the appliance only on water lines with a pressure of 10 to 40 psi Installation Location Do not place the appliance at a location with high humidity to prevent damages to the electrical components Do not place the system under sun light or any light sources Do not spray water or liquid on the appliance Replacement of Filter Cartridge Replace filter cartridge as recommended The replacement of filter cartridge is essential for the appliance to perform as intended Please read and follow the instruction closely to ensure that you R O drinking water appliance operate effectively Failure to install operate and maintain the appliance as instructed will void the warranty Eureka Forbbes Water Purification System INSTALLATION INSTRUCTIONS Eureka Forbbes Water Purification System has been designed for under the sink installation System is supplied with most of the built in connection A few connections however need to be made by customers themselves Our technicians are also available to do the job for you Kindly follow the flow chart and complete the connections Mount the system on to the wall where it has to be installed Slot holes are present in the back plate of the system for mo
10. al as that is carbon particles washing away a ESCUTCHEON PLATE r PA WHITE EVA WASHER P P um COUNTER TOP d KITCHEN CABINET BLACK LOCATION WASHER LOCK WASHER NUT HEXAGONAL BRASS NUT 1 1 4 PLASTIC FERRULE 1 4 COMPRESSION NUT Eureka Forbbes Water Purification System ANSWERS TO SOME QUESTIONS YOU MAY HAVE ON THE POTABILITY OF WATER Aren t domestic filters good enough Filters trap dirt particles However these dirt particles so trapped can serve as breeding grounds for bacteria This bacterium multiplies at a phenomenal rate which flows out along with the drinking water Eureka Forbbes Water Purification System effectively destroys microscopic bacteria and viruses by the R O treatment What about filtration after boiling Micro organisms are inactivated if the water is heated to boiling temperature However subsequent cooling and handling can lead to re contamination Filtering again will trap dirt particles and bacteria will again breed on these dirt particles multiply and flow out along with the output water Eureka Forbbes Water Purification System avoids all this by purifying water just before you drink it What about chemical treatment like addition of chlorine tablets drops to drinking water Chlorine is a toxic chemical Its use requires utmost care and caution Besides chlorine gives water a peculiar taste and odor which also forms cancerous compounds Eureka Forbbes Water Purif
11. ated in the process of natural osmosis Benefits RO removes ionized salts colloids and organic molecules down to a molecular weight of 100 It gives zero tds with out bacteria or any other virus You can test the water if you feel water is not good its life is 1600 gallon and pressure is 125 psi Procedure The TFC membrane can separate up to 99 of remaining unwanted impurities from your water including tribal methane bacteria guardian etc The post filter can also remove the remaining impurities in your pure water and also make water taste sweeter With a protect booster pump it can boost your system and make it produce pure water more efficiently 9 Water Tank Its storage capacity is 4 four Gallons its height is 11 2 inches and weight is 3 2 kg Air charge is 8 psi This tank is rust proof and also approved from FDA 10 Post Carbon Filter It is an inline filter for post filtration for reverse osmosis e Install the cartridge according to the recommended flow pattern Cartridge will get chocked and flow rate will drop in case of wrong connection e Flush 4 gallons of water through the filter before use e Do note use where the water is microbiologically unsafe or of unknown quality without adequate disinfection before or after the unit 17 Specifications e Flow rate e Pressure rating e Temp rating e Service life e Port fitting e Burst Pressure 11 Ultra Violet Sterilizer Eureka Forbbes Water Purificat
12. es should not contain Coliform No E Coli in 100 ml GENERAL STANDARDS FO SOME WATER CHARACTERISTIC AND CONSTITENTS EXPRESSED AS PPM Chlorides as CaCo3 Color as APHA units Fluoride as F Hydrogen sulfide H2S Iron as Fe MBAS Manganese as Mn Ph Sulphates as CaCo3 TDS as CaCo3 Lead Radium 226 228 Silver Excellent Less than 100 Less than 3 Less than 0 1 Less than 0 05 Less than 0 05 Less than 0 2 Less than 0 01 7 0 7 4 Less than 100 Less than 200 Good 100 250 3 15 0 1 0 3 0 05 0 1 0 05 0 3 0 2 0 5 0 01 0 05 7 0 8 5 100 250 200 500 Usable 250 500 15 30 0 3 0 8 0 1 0 2 0 3 0 4 0 5 10 0 05 0 10 6 5 9 0 250 500 500 1 000 Passable 500 1 000 30 50 0 8 12 0 2 0 5 0 4 0 5 1 2 0 10 0 15 6 5 9 0 500 1 000 1 500 Generally Unacceptable Over 1 000 Over 50 Over 1 3 Over 0 5 Over 0 5 Over 2 0 Over 0 155 Less than 6 5 or more than 9 5 Over 500 Over 1 500 Over 0 05 Over 5 0 Over 0 10 Current U S EPA Drinking Water Range 250 15 color units Quei 0 3 0 05 6 5 8 5 250 500 0 05 5 0 pCi L 0 05 OTHER GENERAL LIMITS OF WATER CHARATERISTCS OR CONSTITUENTS Chemicals Permissible Criteria Chemicals Permissible Criteria Arsenic As As As 0 05 Ppm Cyanide 0 20 ppm Barium 1 0
13. fication System in details and will provide tips on installation along with useful information in Reverse Osmosis Technique With best wishes Pure Water Healthy Life Eureka Forbbes Water Technologies Consumer Products Division Eureka Forbbes Water Purification System INTRODUCTION Eureka Forbbes Water Purification System has been designed to tackle most of water pollution problems System is made in modular form to treat individual pollutant problems Sediments Taste Odor Organic Chemicals and Salt one by one in different stages Considering the importance of aesthetic value of fresh and smell free water purification removal of taste and odor producing chemicals is done in more than one stage For removing excessive amount of salt brackishness from water best quality reverse Osmosis Membrane TW30 1812 50 has been incorporated in the system Your Reverse Osmosis System has been thoroughly tested and inspected for leaks product water quality product water output and shut off function for at least 48 hours at our factory Therefore the system may have some water in it You may install the R O System on either side of the cabinet panels underneath your kitchen sink Important Reminder The Undersink Reverse Osmosis drinking water appliance is designed to connect permanently to home plumbing system The appliance should only be connected to municipal water supply under the following conditions Water Condition
14. h Flushing Selonoid Powe PUMP Pump Inlet Selonoid MANUAL TANK FULL NOWATER FLUSH Q CLEAN CHANGE FILTRATION RESET REVERSE OSM S CONTROL R Grev Grey Pump Black EI ck Transformer Auto Flushing System Sequence of Operation When turn the power on the system intellect the incoming tap water supply pressure through a low pressure switch and if the pressure is in the safe working range the system will start Pump inlet solenoid will open The flushing solenoid will open for 60 seconds and close High pressure switch will check the in let water pressure to ensure the pressure will not crossing the safety limit for the membrane System will run until the product tank full signal achieved though the high level switch The system will automatically restart when demand signal generate with low level from product tank Features Auto Flushing It is the world most modern technologies for RO systems Built in the self clearing procedure so the membrane remains clean Raw water contains high amount of salt particles These particles are separated and washed away continuously during the normal operation A situation may arise however when the plant is stopped for a long time for some reason or the other and that there is no water flow This may result in the settling of some of the Eureka Forbbes Water Purification System salts on
15. ication System does away with the addition of chlorine to your drinking water It purifies water without using any chemicals Does one have to boil water before consumption Eureka Forbbes Water Purification System purifies water in following stages 1 Pre filtration removal of sediments 2 3 Purification taste and odor removal double treatment in 2 stages as well as color 4 Desalination removal of salt 5 Polishing and purification taste and odor improvement and polishing Thus providing you potable drinking water at the flick of a switch So you don t have to worry about the cumbersome process of boiling and also risk of re contamination while cooling Eureka Forbbes Water Purification System Does Eureka Forbbes Water Purification System have a pre filter The pre filter is very much a part of the system which is provided with a Poly Propylene Yarn Cartridge of 5m Five Micron The pre filter cartridge strains out all physical impurities present in water and improve the appearance of water The pre filtration cartridge also prolongs the life of the Activated Carbon Cartridge which is used in the second stage The pre filtration cartridge is replaced after every 3 4 months average or when there is a significant decrease in the amount of water being treated by the unit due to clogging of the cartridge What does Granular Activated Carbon GAC Cartridge do GAC Cartridge absorbs dissolved organic impurities like col
16. ion System 0 75GPM 125 psi max 100 F 52 C Quarterly 3 8 NPT Internal 500 Psi A lamp producing Ultraviolet radiation in the 200 300 nanometer range is emitted through clear profiteered particle free water This UV light is extremely effective in killing and eliminating bacteria yeasts viruses molds and other organisms harmful to a human body Ultraviolet systems UV expose supply water to intense ultraviolet radiation which kill pathogenic bacteria cholera typhoid salmonella dysenteries etc virus however is not effective against cysts It has low power consumption Its flow rate is 1 0 GPM 3 8lit min lamp life is 10 000 hours 1 2 Hydronic Vitalizer It is all about the information in the water and its cluster sequence The information which is good for human body is transferred to water water memorizes it and affects the human body in a positive way Procedure The Hydronic vitalizer is a tube made of stainless steel inox used in pharmaceutical and food industry covered with informed glass informed quartz sand informed water and some other carriers of information which are inserted in a larger tube made from the same material The vitaliser like the informed glass does not need to contain energy or any other substances Glasses and vitalisers are manufactured according to the original Hydronic technology which is based exclusively on information The information is captured by means of special de
17. n 1 Water should be collected in a sterile container impervious to light min quantity 125 ml 2 The container should be maintained at 4 C to 10 C during transportation 3 Water should be transported within one hour and tested in the next two hour of sampling i e analyzed within 3 hours of sampling RECOMMENDED TESTS FOR WATER ANALYSIS Water should be tested for 1 Total plate count by membrane filtration technique 2 Total coliform count Detailed procedures to be followed are as per Standard Methods for Examination of Water amp Wastewater 1985 16th Edition prepared amp published by the American Public Health Association USA Pages 860 901 Water testing if any shall be done as per procedure specified in the User Manual and comparison if any shall be done only against W H O standards as specified in the User Manual Documents pertaining to the efficacy of ultraviolet light in water purification system are available at Eureka Forbbes Office NOTE Modification in the production may be introduced from time to time and consequently the details given in this manual are subject to alteration without pervious notice STANDARDS FOR POTABLE WATER Standard for drinking water W H O U S E P A A P H A A W W A Total Bacteria Count E Coli Test not specified by W H O 95 of the samples should not contain coliform No E Coli in 100ml 5 Organisms ml 95 of the sampl
18. n 5 Micron WPP 1 05E Cartridge with Plastic Mounting Bracket PB Graduated sediment removal 100 polypropylene construction Cartridge free of surfactants binders and adhesives The age of filter depends upon the condition of water which is coming from municipality water pipe lines If water is more contaminated so filter will be changed earlier The life of filter depends upon condition of water Its life span is 3 4 month 3 Booster Pump It enhances the water pressure to the desired pressure required for the system product It is a positive displacement diaphragm pump Santoprene and polypropylene materials High safety Driver 24 VDC soft mounting for less noise and vibration Port fitting 3 8 X 1 4 inches tube elbows Its maximum pressure allowed is 120 psi 4 Opaque Housing This housing is for granular cartridge this is also poly carbonate but not transparent 5 Dual purpose Cartridge This cartridge is made of spun polypropylene it again does the same filtration which was done earlier by two cartridges for further purification more 6 Housing This housing is for granular dual cartridge It is made up of reinforced polypropylene material but not transparent 7 Granular Activated Carbon Cartridge GAC Series cartridges effectively reduce discarded tastes odors and chlorine from your drinking water They are designed to allow maximum contact between the water and carbon ensuring maximum adsorption 16 Eureka Forbbe
19. nk where you can conveniently install the faucet Disconnect blue hose from the faucet and secure the faucet to the sink by tightening the brass nut and washer 7 Assemble drain tap around drain pipe under the sink Firmly tighten bolts and nuts evenly Brackets should be parallel Drill a 5 16 hole on drain pipe through threaded hole of the drain tap Connect blue hose to the faucet and tighten faucet Eureka Forbbes Water Purification System Wall Mount Mixer or Faucet Option Turn off water main valve Remove the faucet Install feed water adapter valve on the cold water side only Install the extension piece on the hot water side Reinstall the faucet Bop pr START UP OF THE PURIFICATION SYSTEM 1 Make sure that all connections are secure 2 Turn on feed water adapter valve and check for leaks If any leaks are found do not proceed further until the leaks are fixed 3 Insert the plug into an appropriate electric power outlet Check Operation Status 1 Measure TDS and recovery rate 2 After flushing use TDS meter to measure the TDS value of purified water and compare the valve to the feed water 3 The purified water reading should read about 5 8 percent of feed water reading Warning Check R O System thoroughly for any leaks Make sure all fitting are tight observe for few hours Note Always waste the first water tank full of water before use If the first tank full of water has black residue it is norm
20. on removal of salts 5 Polishing and purification taste and odor improvement and polishing REPLACEMENT COMPONENTS CARTRIDGES 1 Pre filtration Unit 1st Stage Water is filtered at this stage before it is fed through pump pressure to the second and onward stages Eureka Forbbes Water Purification System Filtration rating 5 micron Cartridge type In depth filter Replacement cartridge WPP105R SPP105G So Safe Products 2 3 Water Purification Units 2nd and 3rd Stages 4 Pumped water is purified in two stages to give odorless and fresh water All organic pollutants including chlorine are removed from the water in second and third stages Cartridge type Taste and odor removal Replacement cards GAC 101 D 2nd stage So Safe Products DPC 1 OSR 3rd stage So Safe Products Reverse Osmosis Unit 4 Stage Filtered and purified water is desalinated in the 4th R O Stage Thin film composite Reverse Osmosis Membrane is installed in the unit for the best permeate water quality and efficient Cross Flow filtration where membrane keeps on cleaning itself automatically to ensure a long period Treated water is stored in the Water Storage Tank from where it can be drawn by turning the faucet valve Treated water comes out from the faucet after passing through the last Carbon Filter Cartridge 5th stage Membrane type i Thin film composite TFC FILMTEL OR SO SAFE PRODUCTS Model ff TW30 1812 50
21. on pre filters concentration in you area As a general rule if the chlorine concentration is less than 0 2 ppm use the following equation to calculate the Replacement Frequency RF 6 000 gallon X 0 15 nn RF Usage person day gallon day X number of person in household Diagram Membrane element Replace when persistent high TDS value exist Diagram In line carbon Replace after every 2 500 gallons post filter cartridge Note Filter change and system inspection is available and should be preformed once every year for optimum performance Eureka Forbbes Water Purification System as g Drain 12 10 14 Eureka Forbbes Water Purification System 15 Eureka Forbbes Water Purification System Water purification system 1 Housing The entire housing is made up of unbreakable and high pressure sustaining FDA approved poly carbonate material Seeing makes it easy to believe The transparent housing allows you to see what passes through it and thus monitor the filters condition by its colour 2 Sediment filter It removes rust dust and all other suspended particle from water Wood Mattel chips insects amp ancients Wound P P Yar
22. our free chlorine insecticides pesticides etc It would need replacement depending on the organic matter contamination input water and the quantity of water consumed Granular Activated Carbon GAC Cartridge would require replacement after every 4 month of usage when the unit is in use in office or after every 6 months in home How to replace the cartridge pre filter and purification filter 1 To replace filter cartridges first disconnect the plug and turn off the water valve if open 2 Unscrew the sump portion of the filter housing turning it in the anti clockwise direction with the spanner 3 Remove the old cartridge from the sump wash the sump with soap detergent and then rinse with water 4 Remove the shrink wrap from the new cartridge and place it in the same position 5 Tighten the sump back This time in clockwise direction Don t use spanner for the tightening of the sump This may over tighten the sump consequently cracking sump of the housing The turn on the tap and release the air from the housing by pressing the Air Releasing Button present on the wall mounting bracket Keep the button in the pressed position till water starts ooze out from it 6 In the beginning some particles may be seen floating in the treated water Drain the water through the unit for about 2 to 3 minutes until all such particles are drained Eureka Forbbes Water Purification System RECOMMENDED PROCEDURE FOR WATER TESTING Collectio
23. rring to the Troubleshooting section Away From Home 1 If you are not using the system for more than two weeks shut off the system and drain the stored water 2 Turn off feed water adapter valve Restarting the System 1 Turn on the feed water adapter valve 2 Plug in the power supply Changing the Filter Cartridges If you are not familiar with the appliance please call your local service centre or distributor for servicing 1 Follow the proper procedure to shut off the system 2 Use a housing wrench to open the housing Make sure the system always stands upright during filter changes 3 Replace the correct cartridge Lubricate the O ring with a small amount of petroleum or glycerin e g Vaseline filter housings O ring do not used efface at threads Please ensure that proper direction of flow is maintained before changing the filter Eureka Forbbes Water Purification System SYSTEM MAINTENANCE The replacement of the filter cartridge depends greatly on the quality and condition of the water in your area Use common sense and good judgment to determine the replacement time To ensure that your reverse osmosis drinking water appliance performs at its maximum capacity please follow the maintenance manual Cartridges Recommended Replacement Frequency Diagram B Sediment filters Replace after every three months or as often as needed Diagram A Replacement depends on the water usage and chlorine Carb
24. s Water Purification System The construction of the cartridge allows water to enter at one end and pass through the entire length of the cartridge while an internal expansion pad eliminates channeling or bypass Before the water exits the cartridge a post filter helps remove carbon fines and other suspended particles from the filtered water The post filter is permanently fastened to an innovative support basket ensuring that it is firmly secured and eliminating any potential for bypass Its life span is 4 month if it is using in office and 6 month if it is used in home 8 Reverse Osmosis Filtered and purified water is desalinated in reverse osmosis Thin film composite reverse osmosis membrane is installed in the unit for best permeate water quality and efficiency cross flow filtration where the membrane keeps cleaning itself automatically to ensure longer service period Treated water is stored in a storage tank from where it can be drawn by turning the faucet value Treated water comes out from faucet after passing through last carbon filter cartridge Definition A water treatment process that removes undesirable materials from water by using pressure in order to force the water molecules through a semi permeable membrane This process is called reverse osmosis because the pressure forces the water to flow in the reverse direction from the concentrated solution to the dilute solution to that of the flow from the dilute to the concentr
25. unting purpose Connect the feed water line cold water line supplying to sink faucet to the feed water pipe of the system Feed water connector with brass ball valve is supplied to make the connection Use Teflon tape to make sure that there are no leakages Likewise connect the drinking water faucet to the pipe coming from the Post Carbon Filter Cartridge A hole needs to be made in the sink for faucet fixing Flow Restrictor brine flow control pipe has to be put in the drain so that Cross Flow reject water can go to drain After making all the above connections connect the power plug to the electric supply line open or feed water connector value so that water starts flowing into the system The system will start working and you will be able to take water after a few minutes Drain one full tank of water before taking the water for potable use In case you find any problem in installing the system please seek assistance from your local distributor Different installation methods are used depending on the type of water supply piping arrangement in you home Undersink Supply Piping Arrangement Turn off cold water valve or the main valve Loosen nut at the top of riser Install the feed water adapter valve Reconnect the nut with cone washers to the feed water adapter Connect 1 4 or 3 8 tubing to feed water adapter valve using compression nut plastic sleeve and insert DD 6 Drill at 7 16 or 1 2 hole on top of the si
26. vices and embedded in the glass and other auxiliary carriers and harmonisers of information According to the original Hydronic technology it is important for the buyer of this technology to have the opportunity of selecting the kind of information embedded in the medium in this case the glass carriers and harmonisers of information According to the original Hydronic technology it is important for the buyer of this technology to have the opportunity of selecting the kind of information embedded in the medium in this case the glass is used for water to drink in large quantity 18 Eureka Forbbes Water Purification System Benefit It tastes better it looks better more clear and transparent if we drink this water our body uses less energy for adapting the water according to its needs it can therefore use more of its energy for self healing and for the regulation of other life processes used externally this water has a beneficial influence on the person s mood and skin vegetables watered with vitalized water grow stronger and maintain a fresh appearance for a longer time vegetables and fruit washed in vitalized water rapidly regain their freshness vitalized water can improve the microbiological conditions of water and other aqueous solutions with which it comes into contact Informed water can help preventing diseases in farming it helps achieving better yields of farm products without exerting force on nature with artificial compounds
Download Pdf Manuals
Related Search
Related Contents
USER OPERATING INSTRUCTIONS hoja tecnica GE JBC26P User's Manual S3750THS Quick Guide HP HSR6800 Command Reference Guide FX-3500 耳又扱説明書 { - 日立の家電品 I Installazione, uso e manutenzione pag. 2 UK Installation 3A1771L, Low Pressure Fluid Regulators, Instructions Télécharger - EnerSys Copyright © All rights reserved.