Home
USER OPERATING INSTRUCTIONS
Contents
1. combination will not be accepted if it varies from the current combination by only one digit When selecting a combination do not use a birthday or other predictable information that could give correlation between the user and the combination 4 Enter new valid combination again for verification 5 Record the new combination and store it in a secure place For ComboGard Pro AuditGard or TimeGard 1 Enter current valid combination holding down the last digit until two sets of double beeps occur AA lt lt 2 Press 0 Double beep M 3 Enter new valid combination Note New combination will not be accepted if it varies from the current combination by only one digit When selecting a combination do not use a birthday or other predictable information that could give correlation between the user and the combination 4 Enter new valid combination again for verification 5 Record the new combination and store it in a secure place P N 737 098 Rev A e 04 09 copyright 2009 Kaba Mas LLC Page 3 of 4 WRONG TRY PENALTY DISPLAY A time penalty of 5 minutes will start after the 4th consecutive wrong combination has been entered During a wrong try penalty period PEN is displayed in the LCD display area Two more consecutive wrong combinations entered after the penalty has expired will start another 5 minute penalty BATTERY LOW WARNING The battery low warning occurs if the battery drops below 6 volts during so
2. LA GARD 8130 ELECTRONIC ENTRY DEVICE USER OPERATING INSTRUCTIONS The following instructions cover the user operations of the 8130 Electronic Entry Device FEATURES e Keypad Entry for Electronic Lock e LCD Display Area for Time Delay Open Window and Penalty Display e Jumper Switches to Change Time Delay Counting Direction e Compatible with the following lock code ComboGard 33E V2 13 8130 ComboGard Pro 39E V1 01 AuditGard 66E LGA V1 20 TimeGard TL11 V1 30 and V2 22 8130 ENTRY DEVICE RESPONSES e Valid Code Entry Two beeps M e Invalid Code Entry Three beeps MANA e Input Disabled AuditGard or TimeGard Four beeps MAMAMA e Timelock Denied Access TimeGard One long beep 2 seconds amp DEVICE SETUP At first power up with a programmed lock or after battery replacement the entry device must learn the settings of the lock to which it is attached Note f the entry device has already been attached to the lock powered up first time or with replacement battery and cycled through a time delay open window cycle you do not need to complete the device setup at this time 1 Connect the cable from the 8130 Entry Device into the connector port marked ENT on the programmed lock 2 If the battery has not yet been installed remove the battery cover and connect a new 9 Volt Alkaline battery to the battery connector Use of a high quality name brand battery Energizer or Dur
3. acell is recommended Note Once the battery is connected the system will run a self check of the display and buzzer 3 Place the battery back in the battery compartment and put the cover back in place 4 Initiate a time delay opening of the lock by entering a valid combination The time delay period will start and you must let the full delay and opening period complete for the entry device to learn the lock settings DO NOT interrupt the time delay open window cycle Note Regardless of the current jumper switch settings the time delay cycle will count up the first time P N 737 098 Rev A e 04 09 copyright 2009 Kaba Mas LLC Page 1 of 4 OPEN LOCK 1 Enter valid combination 2 For Dual User access enter the second valid combination 3 Open the container within 4 seconds TIME DELAY DISPLAY The time display will operate during a time delay period and opening window The time display format is mm ss minutes and seconds The default device operation is set to count down for the time delay period and count up for the opening window To change the counting direction see section on CHANGE COUNTING DIRECTION Figure 1 CHANGE COUNTING DIRECTION Two jumper switches are available on the control card of the entry device to control the counting direction of the LCD display for time delay and open window No jumper Count up Jumper on Count down The device is shipped with a jumper on the switch for time
4. delay and no jumper on the switch for the opening window as shown in the photo Figure 1 therefore the default status of the device is that time delay counts down and the opening window counts up Jumper On No Jumper Delay Open An additional jumper is included in the hardware pack with switch switch the entry device You can change the counting direction s Count Down Count Up by adding another jumper by switching the position of the original jumper or by removing the original jumper Note To remove the back cover use a medium sized Phillips head screwdriver If you change the jumper settings they will not be recognized until the next power up of the entry device Therefore you must remove the battery if installed and drain the remaining power by holding and pressing a key or by pressing multiple keys continuously OPEN LOCK WITH TIME DELAY 1 Enter valid combination The time delay display will be activated See TIME DELAY DISPLAY 2 Once the Time Delay has expired and the lock has entered the open window enter valid combination again 3 For Dual User access enter the second valid combination 4 Open the container within 4 seconds TIME DELAY OVERRIDE This feature enables a User to override Time Delay The feature must be programmed when the lock is set up Refer to the Manager instructions for more detail If operating in Dual Combo Mode the manager or a user combination must first be entered then t
5. he override combination P N 737 098 Rev A e 04 09 copyright 2009 Kaba Mas LLC Page 2 of 4 INITIATE SILENT DURESS ALARM This operation is intended to work in conjunction with an alarm box The feature must be programmed when the lock is set up For ComboGard AuditGard or TimeGard The silent duress combination is created by taking your existing combination and adding or subtracting 1 from the last digit of the combination For example if the PIN is 526674 entering 526673 or 526675 will activate the silent duress alarm If the combination is 526699 entering 526698 or 526690 will activate the alarm For ComboGard Pro The silent duress combination is created by taking your existing combination and adding 1 to the last digit of the combination For example if the PIN is 526674 entering 526675 will activate the silent duress alarm If the combination is 526699 entering 526690 will activate the alarm Once the silent duress combination is entered the silent duress alarm is activated and normal lock operation continues CHANGE COMBINATION Caution Before changing a combination open the container door to allow testing with the new combination If you make a mistake while performing this operation wait 30 seconds and start over For ComboGard 1 Enter all O s for the combination 2 Enter current valid combination 3 Enter new valid combination Note New
6. lenoid activation Multiple beeps MAAM BATTERY REPLACEMENT iF Remove the battery compartment cover at the bottom of the entry device 2 Remove the battery from the battery compartment amp carefully disconnect the battery Caution Hold the battery terminal connector while disconnecting the battery to avoid ripping the battery wires out of the assembly Connect a new 9 Volt Alkaline battery to the battery connector Use of a high quality name brand battery Energizer or Duracell is recommended Note Once the battery is connected the system will run a self check of the display and buzzer If the entry device beeps when the battery is reconnected the power has drained off completely and the entry device must go through a device setup Initiate a time delay open window cyle once again to allow the entry device to relearn the lock settings Refer to the section on DEVICE SETUP 4 Place the battery back in the battery compartment and put the cover back in place 749 W Short Street Lexington KY 40508 USA Phone 859 253 4744 FAX 859 255 2655 Technical Support 800 950 4744 www kaba mas com P N 737 098 Rev A e 04 09 copyright 2009 Kaba Mas LLC Page 4 of 4
Download Pdf Manuals
Related Search
Related Contents
DMVC Accessibility User Guide PDFファイル - JISC 日本工業標準調査会 Dell 3333dn and 3335dn Laser MFP User`s Guide Manual Simplificado Planet tab BV-4000 Mode d`emploi pour évaluer un stage ambulatoire sur le site du DES UP-D25MD - Daitron[ダイトエレクトロン株式会社] Modelo 161 Máquina de sorvete soft Instruções de operação Consultez la plaquette - Conseil Général du Lot-et SÉcURitÉ AÉRiENNE — NOUvEllES Copyright © All rights reserved.