Home

design for TV - WISI Norden AB

image

Contents

1. the EMU 100 and E series module Connect the power supply and make all necessary settings as described in section 4 9 English 6 Technical specification EMU 100 High quality E Series remote management unit The EMU 100 is a product enabling remote Dimensions 19 rack unit 1HE high management of all A2B Electronics E series Supply voltage 100 240 VAC modules ovet IP This will enable operators to Supply current 100mA efficiently manage their head end systems in a 1 Ethernet port 100 10 Mbit s very cost and time effective manner and you 20 RS 232 ports 115 2 kbit s can view status and easily change the settings in Controller PC software included connected modules from your office Control connector RJ 45 Ethernet Operating temp 0 to 50 C Control and Settings The unit is controlled via an RJ 45 Ethernet connector on the front Softwate is included for control via a PC This specification may be subject to change without prior notice 10 English 7 Declaration of Conformity Declaration of Conformity EC Directives EMU 100 fulfills relevant parts of the directives and standards as below Directives Electro magnetic compability directive EMC 89 339 EEC e Low voltage directive LVD 73 23 EEC e CE marking directive 93 98 EEC Standards EMC Emission EN61000 6 3 2001 Immunity EN61000 6 1 2001 Safety EN 60 950 1 2001 The document for Declaration of Conformity you will find at www
2. Choose serial port from the list below EMU O Connected Ra ETC 100 ESC 100 ETA 100 ECA 100 QUIT Firmware Valj en enhet och klicka p OK f r att ansluta Efter anslutning kan enheten konfigureras via kontroll interfacet Man kan ven skifta mellan de olika anslutna enheterna i detta kontroll interface F r konfigurering av enheterna se vidare i Anv ndarmanualen f r respektive enhet 21 Svenska 5 Installation EMU 100 kan anslutas till upp till 20 E seriemoduler Varje modul kan konfigureras av kontrollmjukvaran b r vara 2 5 1 eller senare EMU 100 beh ver tilldelas en statisk eller en dynamisk IP adress En statisk IP adress kan tillhandah llas fr n din ISP Internet Service Provider eller fr n systemadministrat ren i ett lokalt n tverk LAN En dynamisk IP adress kan tilldelas fr n en DHCP server hos din ISP eller fr n en DHCP server i det lokala n tverket LAN EMU 100 r f rinst lld f r att h mta en IP adress fr n en DHCP server Om du har erh llit en statisk IP adress fr n din ISP beh ver du konfigurera din EMU 100 f r en statisk IP adress genom att ansluta dig lokalt och sedan trycka p Assign IP se vidare i kapitel 4 om Inst llningar f r PC All kommunikation r krypterad med AES och SSH Portar 10001 och 22 m ste vara ppna i det aktuella n tverket Tillse att alla andra anslutningar r anslutna till EMU 100 innan man ansluter sp nningsmatningen E seri
3. Det fullst ndiga dokumentet f r Declaration of Conformity terfinnes p www a2b se A CE Se vidare p www a2b se a2b design for TV 25 26 27 2b design for TV A2B Electronics AB S dra All n 23 25 591 37 Motala P O Box 14 591 21 Motala SWEDEN Phone 46 141 229100 Fax 46 141 229101 E mail market a2b se To view our full line of Professional E series
4. a2b se A CE Further information at www a2b se a2b ign for TV in 12 English 13 English ANV NDARMANUAL ingsenhet f r E serien English Svenska pa ee i SS SS i iti d Care zt ak ek st ak ak et A A A 96 gt IE a a a A A E E00 amp Mr ir a gt rn design for TV Inneh ll Introduktion Uppackning av enheten Kontakter och indikeringar Inst llningar med PC Installation Teknisk specifikation Declaration of Conformity eS RE 15 Svenska 1 Introduktion Tack f r att ni har valt en A2B Electronics produkt Denna produkt r utvecklad f r att ni som kund skall vara n jd med dess prestanda och funktioner under m nga r EMU 100 kan anv ndas f r att fj rrstyra alla typer av E seriemoduler fr n A2B Electronics Fj rrstyrningen ger m jlighet att vervaka och styra en huvudcentral p ett kostnadseffektivt och tidsbesparande s tt EMU 100 har en Ethernet anslutning och 20 serieportsanslutningar RS 232 f r att ansluta E seriemoduler Denna manual inneh ller installations och inst llningsanvisningar Om du beh ver ytterligare assistans vid installationen kontakta din lokala handlare eller kontakta v r tekniska support p f ljande telefonnummer eller via e post A2B Electronics AB Tel 0141 22 91 15 E post support a2b se Bes k ocks v r hemsida p www a2b se f r ytterligare support 1
5. 6 Svenska 2 Uppackning av enheten Enheten leveteras med all n dv ndig mjukvara f r att kunna g ra alla inst llningar med PC Filerna finns p den medf ljande CD skivan F ljande delar skall finnas i paketet Antal Beskrivning 1 EMU 100 fj rrstyrningsenhet inkl n tsladd 1 CD ROM med bruksanvisning och kontrollmjukvara 1 Denna manual i tryckt version Varje enhet r kvalitetskontrollerad av oss f re leverans men om n got skulle fattas i paketet kontakta v r support se sidan 16 f r kontaktdata OPERATING INSTRUCTIONS design for TV 17 Svenska 3 Kontakter och indikeringar LU j an i aa N tsladdsanslutning 230 VAC Ethernet kontakt RJ 45 LAN anslutning och indikering di Ag nn till E seriemoduler av datatrafik Tillbeh r Nollmodemskabel Kabel f r anslutning mellan EMU 100 och andra moduler i E serien l ngd ca 20 cm artnr 500080 01 18 Svenska 4 Inst llningar med PC Nedan beskrivs steg f r steg hur man ansluter EMU 100 till en PC Se till att kontrollmjukvaran p produkt CDn r installerad p din PC Anslut din EMU 100 till n tsp nning 230 V AC Koppla in alla E seriemoduler som ska anslutas till EMU 100 med nollmodemskablar Anslut d refter din PC till EMU 100 med en Ethernet kabel Starta kontrollmjukvaran OBS M ste vara version 2 5 1 eller senare Om kontrollmjukvaran r en ldre version finns den senaste att ladda ned fr
6. OPERATING INSTRUCTIONS note Management Unit English Svenska pa ee i SS SS i iti d Care zt ak ek st ak ak et A A A o 96 gt gt a a a A A A E00 amp Mr ir a gt rn design for TV Introduction Unpacking the unit Connections and indications Settings with PC Installation Technical specification Declaration of Conformity A RT 2 English 1 Introduction Thank you for choosing this quality product from A2B Electronics We have made every effort to ensure that you as a customer are satisfied with the performance and features of this product for years to come The EMU 100 is a product enabling remote management of all A2B Electronics E series modules This will enable operators to efficiently manage their head end systems in a very cost and time effective manner The EMU 100 has connection for Ethernet and 20 serial ports RS 232 for connection to the E series modules This manual describes the installation and set up of the unit For further assistance contact your local dealer or A2B technical support at AZB Hlectronics AB Phone 46 0 141 229115 E mail support a2b se You can also visit our website www a2b se for further support 3 English 2 Unpacking the unit EMU 100 is delivered with all necessary software to enable all the installations The files are on the included CD and a PC can be used as a control unit The foll
7. emodulerna ansluts via serieporten med nollmodemskablar till EMU 100 Anslut d refter sp nningsmatningen till EMU 100 och g r de inst llningar som beskrivs i kapitel 4 22 Svenska 6 Teknisk specifikation EMU 100 Fj rrstyrningsenhet f r E serien Med EMU 100 kan man fj rrstyra samtliga AZB s M tt E seriemoduler ver IP Fj rrstyrningen ger Matningssp nning m jlighet att vervaka och styra en huvudcentral Str mf rbrukning p ett kostnadseffektivt och tidsbesparande s tt 1 Ethernet port Man kan ven se status och l tt ndra 20 RS 232 portar inst llningarna p de anslutna modulerna direkt Kontrollenhet fr n sitt kontor Kontrollport Driftstemperatur Inst llningar EMU 100 kontrolleras via en Ethernet port RJ 45 p fronten Mjukvara f r kontroll via PC medf ljer produkten Denna specifikation kan komma att ndras utan f reg ende varning 19 rackenhet 1 HE h g 100 240 VAC 100mA 100 10 Mbit s 115 2 kbit s PC mjukvara bifogad RJ 45 Ethernet 0 till 50 C 23 Svenska 7 Declaration of Conformity Declaration of Conformity EC Directives EMU 100 uppfyller de relevanta delarna av nedanst ende direktiv och standarder Direktiv Electro magnetic compability directive EMC 89 339 EEC e Low voltage directive LVD 73 23 EEC e CE marking directive 93 98 EEC Standarder EMC Emission EN61000 6 3 2001 Immunity EN61000 6 1 2001 Safety EN 60 950 1 2001
8. ist below OK QUIT J Firmware Select EMU in the list from the menu shown below and click OK En A2B E series Controller Software v2 5 1 A Serial communication settings Choose serial port from the list below NOT Connected QUIT Firmware 6 English Enter the IP address given by your ISP or press Search if you are connected to a Local Area Netwotk LAN amp Set IP or Host to the EMU Set IP or host name 192 168 0 68 1192 168 0 68 OK Cancel Assignip If you want to configure your EMU 100 for a static IP address click on Assign IP Enter the IP address in the box then click OK This takes you back to the menu above Proceed from there to connect Enter new IP blank for DHCP 192 168 0 68 wn Press OK to connect N B Connecting may take about one minute When connecting to an EMU for the first time the units key is required The units key can be found on a label at the back panel of the EMU 100 after K Password for control 192 168 0 68 7 English After entering the units keyword and on subseguent connections the following dialog will be shown while scanning the EMU for units Scanning EMU C CANCEL When scanning is completed found units can be selected in a dropdown menu Em A2B E series Controller Software v2 5 1 Serial communication settings Choo
9. n www a2b se Nedanst ende meny visas EN A2B E series Controller Software v2 5 1 A Serial communication settings Choose serial port from the list below TT Onorcameces V lj EMU i listan i menyn nedan En A2B E series Controller Software v2 5 1 A Serial communication settings Choose serial port from the list below o NOT Connected 19 Svenska Skriv in IP adressen som du f tt fr n din ISP eller tryck p Search om du ar ansluten till ett lokalt n tverk LAN amp Set IP or Host to the EMU Eg Set IP or host name TI EZ sia FT Mt Om din EMU 100 ska konfigureras f r en statisk IP adress klickar du pa Assign IP Skriv in den statiska IP adressen i rutan tryck sedan p OK Programmet terv nder sedan till menyn ovan Forts tt d rifr n f r att ansluta 192 168 0 68 Tryck p OKJ f r att ansluta Obs Det kan ta ca en minut att ansluta N r du ansluter till en EMU f rsta g ngen m ste enhetens l senord key anges Detta star p en etikett som sitter p enhetens baksida efter K or controlo 5 20 Svenska Efter att ha angett l senord och vid d rp f ljande anslutningar visas nedanst ende f nster under tiden som EMU skannar efter anslutna enheter Scanning EMU X ge CANCEL N r skanningen r klar kan man v lja enheter i drop down listan Em A2B E series Controller Software v2 5 1 Serial communication settings
10. owing items are included in the package Amount Description 1 EMU 100 remote management unit incl power cord 1 CD ROM with operating instructions and control software 1 This operating instruction in printed version Every unit is quality inspected by us before delivery Should any items be missing when unpacking please contact our support service see page 3 for address OPERATING INSTRUCTIONS design for TV 4 English 3 Connections and indications SS p nn en Power supply 230 V AC Ethernet connection RJ 45 LAN connection and traffic indicators Accessories 20 serial connectors RS 232 to E series modules Null modem cable Cable for connection between EMU 100 and modules in the E series approx length 20 cm article no 500080 01 5 English 4 Settings with PC This section describes how to make a first time installation for PC following the step by step instructions below Ensure that the control software files delivered on the CD ROM are installed on your PC Connect the EMU 100 to an AC power supply 230 VAC Then connect your PC to the EMU 100 with an Ethernet cable Next connect the reguired number of null modem cables from the serial ports on EMU 100 to each E series module Start the controller software and menu below should appear a2 A2B E series Controller Software v2 5 1 A Serial communication settings Choose serial port from the l
11. se serial port from the list below EMU v connected ETC 100 Firmware Select a unit in the list and click OK to connect After being selected the unit can be configured using the control interface menu You can also switch between units in this control interface For configuration of the units please refer to each unit s User Manual 8 English 5 Installation The EMU 100 can be connected with up to 20 E series modules and each module can be configured by the control software should be 2 5 1 or later The EMU 100 requires a static or a dynamic IP address A static IP address can be provided by your ISP Internet Service Provider or from the system administrator of your local area network LAN A dynamic IP address can be assigned by a DHCP server from your ISP or from a DHCP server in the local area network LAN The EMU 100 is preset to get a dynamic IP address from a DHCP server If you have received a static IP address from your ISP you need to configure the EMU 100 for static IP address by connecting locally and click the Assign IP button see more in chapter 4 about Settings with PC All communication is encrypted with AES and SSH It is necessary to ensure that ports 10001 and 22 are open in the actual network Before connecting power to the EMU 100 make sure that all other connections have been made A null modem cable should be connected between each serial port on