1. AA Data Delimiter character The address of the module to be set in hexadecimal format 00 to OF gt Data CR AA CR Delimiter character to indicate the command was valid Delimiter character to indicate the command was invalid The address of the module to be set in hexadecimal format 00 to OF The status of the 3 bit digital input output as four digit hexadecimal value See Section 1 5 for more details LC 103 C User Manual Ver 1 0 Mar 2012 27 Se There will be no response if the command syntax is incorrect there is a communication error or there is no module with the specified address Examples Command 02 Response gt 0701 Reads the status of the digital input output channels for module 02 and returns a valid response indicatinfs thst the current Digital Output value is 07 and the Digital Iutput value is 01 Related Commands Section 2 1 AA00 Data Section 2 3 AAIcDD Section 2 4 AAAcDD Section 2 7 AA6 Section 2 10 AA Section 2 11 AA Data Related Topics Section 1 5 DI O Data Format LC 103 C User Manual Ver 1 0 Mar 2012 28 She 2 10 AA Data Description Ths command is used to set the digital output channels of a specified module Syntax AA Data CR Delimiter character AA The address of the module to be set in hexadecimal format 00 to OF Data The data to be written to the digital output channels Bit 0 of the value corresponds to RL and
2. LC 103 C User Manual Ver 1 0 Mar 2012 19 She 0 This is not the first time the command has been sent since the module was powered on which denotes that there has been no module reset since the last AA5 command was sent There will be no response if the command syntax is incorrect there is a communication error or there is no module with the specified address Examples Command 015 Response 011 Reads the reset status of module Oland returns a valid response indicating that it is the first time the AA5 command has been sent since the module was powered on Command 015 Response O10 Reads the reset status of module 01 and returns a valid response indicating that there has been no module reset since the last AA5 command was sent LC 103 C User Manual Ver 1 0 Mar 2012 20 She 2 6 AA6 Description Ths command is used to read the status of the digital input output channels of a specified module Syntax AA6 CR Delimiter character AA The address of the module to be set in hexadecimal format 00 to OF 6 The command to read the status of the digital input output channels Response Valid Data CR Invalid TAA CR Delimiter character to indicate the command was valid ES Delimiter character to indicate the command was invalid AA The address of the module to be set in hexadecimal format 00 to OF Data The status of the digital input output channels
3. Valid gt CR Invalid TAA CR Ignored Command CR gt Delimiter character to indicate the command was valid LC 103 C User Manual Ver 1 0 Mar 2012 17 She Delimiter character to indicate the command was invalid Delimiter character to indicate the command was ingored There will be no response if the command syntax is incorrect there is a communication error or there is no module with the specified address Examples Command 02A201 Response gt Sets RL3 of module 02 to on and the module returns a valid response Related Commands Section 2 1 AA00 Data Section 2 3 AAIcDD Section 2 4 AAAcDD Section 2 7 AA6 Section 2 10 AA Section 2 11 AA Data Related Topics Section 1 5 DI O Data Format LC 103 C User Manual Ver 1 0 Mar 2012 18 She 2 5 AA5 Description Ths command is used to read the reset status of a specified module Syntax AA5 CR Delimiter character AA The address of the module to be set in hexadecimal format 00 to OF 5 The command to read the reset status of the module Response Valid AAS CR Invalid 7AA CR Delimiter character to indicate the command was valid ES Delimiter character to indicate the command was invalid AA The address of the module to be set in hexadecimal format 00 to OF S The reset status of the module 1 This 1s the first time the command has been sent since the module was powered on
4. Relay ON OFF and Function di Remote Status Monitoring Relay Output Output Channels 3 Type Power Relay Form A SPST N O Operating Voltage 250 VAC or 30 VDC Max Load Current 5A Operating Time 10 ms Max Release Time 5 ms Max Electrical Life 100 000 ops Resistive load Mechanical Life 20 000 000 ops at no load 300 ops minute Safety Approval UL CUL T V Power on Value No Safe Value No LC 103 C User Manual Ver 1 0 Mar 2012 4 Ste 1 2 System Specifications Communication Interface RS 485 Format N 8 1 Baud Rate 9600 bps Protocol Modbus RTU DCON Node Addresses 1 31 Connector RJ 11 LED Indicators Power 1 LED as Power Indicator EMS Protection ESD IEC 61000 4 2 2 kV Contact for Each Terminal 4 kV Air for Random Point EFT IEC 61000 4 4 2 kV for Power Power Requirements Input Voltage Range 10 30 VDC Consumption 0 5 W Max Connector RJ 11 Mechanical Dimensions W x L x H 52 mm x 98 mm x 27 mm Installation Screw Mounting Environment Operating Temperature 25 C 75 C Storage Temperature 30 C 75 C Humidity 10 95 RH Non condensing LC 103 C User Manual Ver 1 0 Mar 2012 5 1 3 Pin Assignments Lighting Control Module Relay Outputs Output Channels 3 Outp
5. hexadecimal value where bit 0 corresponds to RL1 bit 1 corresponds to RL2 etc When the bit is 0 it denotes that the digital output channel is off and 1 denotes that the digital output channel is on Response Valid gt CR Invalid TAA CR Ignored Command CR gt Delimiter character to indicate the command was valid LC 103 C User Manual Ver 1 0 Mar 2012 11 Se Delimiter character to indicate the command was invalid Delimiter character to indicate the command was ingored There will be no response if the command syntax is incorrect there is a communication error or there is no module with the specified address Examples Command 020006 Response gt Sets RL1 the module to off and sets RL2 and RL3 to on The module returns a valid response Related Commands Section 2 2 AAOA Data Section 2 3 AAIcDD Section 2 4 AAAcDD Section 2 7 AA6 Section 2 10 AA Section 2 11 AA Data Related Topics Section 1 5 DI O Data Format LC 103 C User Manual Ver 1 0 Mar 2012 12 She 2 2 AA0A Data Description Ths command is used to set the digital output value for each of the three channels RL1 RL3 of a specified module Syntax AA0A Data CR Delimiter character AA The address of the module to be set in hexadecimal format 00 to OF OA The command to set the digital output value RL1 RL2 or RL3 Data A two digit hexadecimal value where bit 0 correspond
6. a four digit hexadecimal value followed by 00 See Section 1 5 for more LC 103 C User Manual Ver 1 0 Mar 2012 21 Se details There will be no response if the command syntax is incorrect there is a communication error or there is no module with the specified address Examples Command 026 Response 070F Reads the status of the digital input output channels for module 02 and returns a valid response indicatinfs thst the current Digital Output value is 07 and the Digital Iutput value is OF Related Commands Section 2 1 AA00 Data Section 2 3 AAIcDD Section 2 4 AAAcDD Section 2 7 AA6 Section 2 10 AA Section 2 11 AA Data Related Topics Section 1 5 DI O Data Format LC 103 C User Manual Ver 1 0 Mar 2012 22 She 2 7 AAF Description Ths command is used to read the firmware version of a specified module Syntax AAF CR Delimiter character AA The address of the module to be set in hexadecimal format 00 to OF F The command to read the firmware version Response Valid AA Data CR Invalid 7AA CR Delimiter character to indicate the command was valid Delimiter character to indicate the command was invalid AA The address of the module to be set in hexadecimal format 00 to OF Data A string indicating the firmware version of the module LC 103 C User Manual Ver 1 0 Mar 2012 23 She There will be no response if the command syntax is in
7. bit 1 of the value corresponds to RL2 etc When the bit is 0 it denotes that the digital output channel is off and 1 denotes that the digital output channel is on Response Valid gt CR Invalid TAA CR Ignored Command CR gt Delimiter character to indicate the command was valid 7 Delimiter character to indicate the LC 103 C User Manual Ver 1 0 Mar 2012 29 She command was invalid Delimiter character to indicate the command was ingored There will be no response if the command syntax is incorrect there is a communication error or there is no module with the specified address Examples Command 027 Response gt Sets RL1 RL2 and RL3 of module 02 to on and module returns a valid response Related Commands Section 2 1 AA00 Data Section 2 3 AA1cDD Section 2 4 AAAcDD Section 2 7 AA6 Section 2 10 AA Section 2 11 AA Data Related Topics Section 1 5 DI O Data Format LC 103 C User Manual Ver 1 0 Mar 2012 30
8. correct there is a communication error or there is no module with the specified address Examples Command 01F Response 0101 02 Reads the firmware version of module Ol and returns a valid response indicating that it is version 01 02 LC 103 C User Manual Ver 1 0 Mar 2012 24 She 2 8 AAM Description Ths command is used to read the name of a specified module Syntax AAM CR Delimiter character AA The address of the module to be set in hexadecimal format 00 to OF M The command to read the name of the module Response Valid A A Data CR Invalid 7AA CR Delimiter character to indicate the command was valid ES Delimiter character to indicate the command was invalid AA The address of the module to be set in hexadecimal format 00 to OF Data A string indicating the name of the module LC 103 C User Manual Ver 1 0 Mar 2012 25 She There will be no response if the command syntax is incorrect there is a communication error or there is no module with the specified address Command 02M Response 02LC103 Reads the module 02 and returns a valid response indicating that the name of the module is LC 103 C LC 103 C User Manual Ver 1 0 Mar 2012 26 She 2 9 AA Description Ths command is used to read the status of the digital input output channels of a specified module Syntax AA CR AA Response Valid Invalid gt
9. d AA eases 13 2 3 A E E O TE E 15 2 4 FA ACOD o E A E OEE 17 2 5 ON 19 2 6 O NO E E E E A 21 2 7 ON 23 2 8 SAAM rota A AE cuca hates ia alitas darian 25 2 9 GSV E ase ET EA E E E E A TA 27 2 10 DAA Data ic eeen e ae ea ae e OAE AEE a E EEEE ata ai aa aE NEA ERa 29 LC 103 C User Manual Ver 1 0 Mar 2012 2 Introduction The LC 103 C is an easy to use lighting control module that requires no specialist skills to install and operate and no software is needed in order to control the DO channels The LC 103 C provides 1 channel for digital input photocouple isolation and 3 channels for relay output All output channels are form A type relays while the input channel is based on a sink type using a wire connection The input channel can be used to directly control a 3 channel relay ON and OFF sequence without requiring a remote host controller 4 kV ESD protection and 5000 Vrms intra module isolation are also provided When required communication with the LC 103 C is programmable based on the DCON protocol and an added benefit is that different addresses can be set for DCON communication via hardware configuration LC 103 C User Manual Ver 1 0 Mar 2012 3 Sis 1 Hardware Information 1 1 lO Specifications Digital Input Input Channels 1 Type 90 240 VAC On Voltage Level 85 VAC Off Voltage Level 60 VAC Input Impedance 68 KO 1 W Isolation 5000 Vrms Local and Remote Direct Control
10. ie LC 103 C User Manual Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year beginning from the date of delivery to the original purchaser Warning ICP DAS assumes no liability for any damage resulting from the use of this product ICP DAS reserves the right to change this manual at any time without notice The information furnished by ICP DAS is believed to be accurate and reliable However no responsibility is assumed by ICP DAS for its use nor for any infringements of patents or other rights of third parties resulting from its use Copyright Copyright 2012 ICP DAS Co Ltd All rights are reserved Trademarks Names are used for identification purposes only and may be registered trademarks of their respective companies LC 103 C User Manual Ver 1 0 Mar 2012 1 Table of Contents TMtrOductiOD a EE T AE A E T NA REA 3 1 Hardware Information sussorsorsonsonsnnssnssnssorsnnsnnsonsnnsnnsnnsnnssnnsonsonsnnsnnsnnsnnnsnssnnsonsnnsnnsnnnnnne 4 1 1 TO Specificatii iS ea rue en en ehe AERE ESEE 4 1 2 SYSTEM Specifications u nee teen een lite sent nee 5 1 3 Pin ASSIM Strand nee Hann en 6 1 4 Wire Connection pidio ineditos cues T 1 5 DO Data Formar 8 2 DCON POCO iccssscscsasscciecsccecaccsicssscsscssccacaasaseateossececssesssacsacacsessessensdbssosdactaacasssbesossecsaasacacaies 9 2 1 HA OOD atta atinada r s 11 2 2 HFAAQA Data nee ate
11. l 00 Sets the relay output channel to off 01 Sets the relay output channel to on Response Valid gt CR Invalid TAA CR Ignored Command CR gt Delimiter character to indicate the command was valid LC 103 C User Manual Ver 1 0 Mar 2012 15 She Delimiter character to indicate the command was invalid Delimiter character to indicate the command was ingored There will be no response if the command syntax is incorrect there is a communication error or there is no module with the specified address Examples Command 021001 Response gt Sets RL1 the module 02 to on and the module returns a valid response Related Commands Section 2 1 AA00 Data Section 2 3 AAIcDD Section 2 4 AAAcDD Section 2 7 AA6 Section 2 10 AA Section 2 11 AA Data Related Topics Section 1 5 DI O Data Format LC 103 C User Manual Ver 1 0 Mar 2012 16 Ihe 2 4 AAACDD Description Ths command is used to set the digital output value for a single channel of a specified module Syntax AAACDD CR Delimiter character AA The address of the module to be set in hexadecimal format 00 to OF A The command to set the digital output value for a single channel C Specifies the relay output channel to be set zero based valid values O to 2 DD The command to set the relay ouput channel 00 Sets the relay output channel to off 01 Sets the relay output channel to on Response
12. ntain the ID address meaning that only the addressed module will respond Command Format Leadi Modul creer Aion Command CR Response Format Gran Aion Dun cr CR End of command character carriage return Ox0D Note All characters should be in upper case LC 103 C User Manual Ver 1 0 Mar 2012 9 Command A AOO Data AAOA Data AAICDD AAACDD SAAS AA6 AAF AAM AA AA Data General Command Sets Response gt gt gt gt AAS Data AA Data AA Data gt Data Description Sets the Digital Output Sets the Digital Output Sets the Digital Output Sets the Digital Output Reads the Reset Status of the Module Reads the Status of the Digital I O channels Reads the Firmware Version of the Module Reads the Name of the Module Reads the Status of the Digital I O channels Sets the Digital Output Channels LC 103 C User Manual Ver 1 0 Mar 2012 10 Ste Section 2 1 22 2 3 2 4 2 5 2 6 2 7 2 8 2 9 2 10 Al 2 1 AA00 Data Description Ths command is used to set the digital output value for each of the three channels RL1 RL3 of a specified module Syntax AA00 Data CR Delimiter character AA The address of the module to be set in hexadecimal format 00 to OF 00 The command to set the digital output value for each of the three channels RL1 RL3 Data A two digit
13. s to RLI bit 1 corresponds to RL2 etc When the bit is 0 it denotes that the digital output channel is off and 1 denotes that the digital output channel is on Response Valid gt CR Invalid TAA CR Ignored Command CR gt Delimiter character to indicate the command was valid LC 103 C User Manual Ver 1 0 Mar 2012 13 Sie Delimiter character to indicate the command was invalid Delimiter character to indicate the command was ingored There will be no response if the command syntax is incorrect there is a communication error or there is no module with the specified address Examples Command 020A02 Response gt Sets RL1 the module to off and sets RL2 and RL3 to on The module returns a valid response Related Commands Section 2 1 AA00 Data Section 2 3 AAIcDD Section 2 4 AAAcDD Section 2 7 AA6 Section 2 10 AA Section 2 11 AA Data Related Topics Section 1 5 DI O Data Format LC 103 C User Manual Ver 1 0 Mar 2012 14 Ihe 2 3 AA1CDD Description Ths command is used to set the digital output value for a single channel of a specified module Syntax AAICDD CR Delimiter character AA The address of the module to be set in hexadecimal format 00 to OF 1 The command to set the digital output value for a single channel C Specifies the relay output channel to be set zero based valid values O to 2 DD The command to set the relay ouput channe
14. ut Type Power Relay Form A Relay Contact Voltage 5A 250 VAC Max Input Voltage 90 240 VAC Power Vs Input Voltage 10 30 VDC Communication Interface COM1 RS 485 D D 9600bps N 8 1 Pin Description 1 VS Power Input Voltage 10 VDC 30 VDC 2 VS Power Input Voltage 10 VDC 30 VDC A RS 485 Serial Communication Interface 5 GND Ground 6 GND Ground LC 103 C User Manual Ver 1 0 Mar 2012 6 Se 1 4 Wire Connections DIO Wire Connections DI u ne D TS 8 DI Relay Output ON kLx AG i RL COM Relay Output OFF Power and communication RS 485 and Power Input Daisy Chain using an RJ 11 Connector LC 103 C User Manual Ver 1 0 Mar 2012 7 1 5 DI O Data Format The data format for the response to the AA4 AA6 and AA commands is the First Data value the Second Data value Note Both the First Data value and the Second Data value are in the format of two hexadecimal digit LC 103 C User Manual Ver 1 0 Mar 2012 8 Sie 2 DCON Protocol All communication with LC 103 C modules consists of commands generated by the host and responses transmitted by the LC 103 C module Each module has a unique ID number that is used for addressing purposes and is stored in non volatile memory The ID is Ol by default and can be changed by sedning a user command All commands to the modules co