Home

PLFRESNEL1 LED Luminaire - Installation & User`s

image

Contents

1. Note Values and levels shown for Preset White in both 16 and 8 bit modes are approximate Due to the characteristics of LED technology actual values may vary slightly between fixtures PLFRESNEL1 LED Luminaire DMX Timing Channel Detail Timing channel control improves the timed moves of certain groups of parameters The PLFRESNEL1 LED Luminaire provides two timing channels in 16 bit mode one for intensity time and one for color time and one timing channel in 8 bit color and intensity timing combined The luminaire uses its timing channel value to calculate a smooth continuous operation for a given time and transition Guidelines Timing channels support time values from zero to 169 seconds To use a timing channel instead of console timing it is recommended to set the timing channel to the desired value and set cue and or console cue fade time to zero A combination of time controls can produce unexpected results The default value setting in the profile should be 255 proportional control to allow smooth operation when using console timing The timing channel data should change as a snap A zero value will give the fastest operation however without any smoothing this can appear steppy in console timed moves Refer to PLFRESNEL 1 LED Luminaire DMX Timing Channel Detail on page 25 for more information Lighting Console Settings for Preset White 25 Installation amp User s Manual PLFRESNEL1 LE
2. Security Level Parameter Values Default Description Security Enter There are 4 levels of security this allows 1 PassPIN 4 Digits 0 to 9 FASE you to change the level while in the Settings Screen 3 Level 1 PIN 4 Digits O to 9 1111 Sets Level 1 PassPIN 3 Level 2 PIN 4 Digits 0 to 9 2222 Sets Level 2 PassPIN 3 Level 3 PIN 4 Digits 0 to 9 3333 Sets Level 3 PassPIN Security Level after Power Up if not 3 Power Up 1 3 or Locked 3 Locked Level 0 PHILIPS 18 OPERATION AND PROGRAMMING Selecon PLFRESNEL1 LED Luminaires Installation amp User s Manual PHILIPS General 1 Power Up 3 Reset Hours Off Scratch Pad Warm White Cool White Day Light Preset30 Preset31 Last Set No Yes Cool White No When the Fixture Powers Up what does it output Scratch Pad is an automatically saved Preset Last Set is the last thing coming out of the fixture this could be Warm White with the intensity changed from that of the Preset Resets luminaire s operational hours Presets 3 Protected No 5 25 Yes Determines if the factory Calibrated Presets Color Mix is protected from changes 3 Load Factory DMX No Yes No Reload Factory Calibrated Presets Intensity changes will also be reloaded 3 DMX Enabled No Yes or Wireless if equipped Yes Enables or disabled DMX communication through the luminaires DMX512 ports Sets the DMX feature to
3. 0 255 0 100 Used to access presets stored in fixture firmware such as CCT presets defined gel presets etc No Preset Activated DMX 0 3 DEFAULT Color Preset 0 Off DMX 4 7 Color Preset 1 Scratch Pad DMX 8 11 Color Preset 2 Warm White DMX 12 15 Color Preset 3 Cool White DMX 16 19 Color Preset 4 Daylight DMX 20 23 Color Preset 5 Arc White DMX 24 27 Color Preset 6 Red DMX 28 31 Color Preset 7 Yellow DMX 32 35 Color Preset 8 Daylight Blue DMX 36 39 Color Preset 9 Magenta DMX 40 43 Color Preset 10 Aqua DMX 44 47 Color Preset 11 Medium Amber DMX 48 51 Color Preset 12 Lavender DMX 52 55 Color Preset 13 Blue DMX 56 59 Color Preset 14 Light Pink DMX 60 63 Color Preset 15 Green DMX 64 67 Color Preset 16 Pink DMX 68 71 Color Preset 17 Amber White DMX 72 75 Color Preset 18 Dark Fuchsia DMX 76 79 Color Preset 19 Light Amber DMX 80 83 Color Preset 20 Steel Blue DMX 84 87 Color Preset 21 Lt Green Blue DMX 88 91 Color Preset 22 Orange DMX 92 95 Color Preset 23 Medium Pink DMX 96 99 Color Preset 24 Cyan DMX 100 103 Color Preset 25 Purple DMX 104 107 Color Preset 26 Custom DMX 108 111 Color Preset 27 Custom DMX 112 115 Color Preset 28 Custom Color Preset 29 Custom Color Preset 30 Custom Color Preset 31 Custom DMX 116 119 DMX 120
4. 0 255 0 100 8 bit control of Blue LEDs from 0 to full no White 0 255 0 100 ojojojo 8 bit control of White LEDs from 0 to full Preset Color Selection 0 255 0 100 Used to access presets stored in fixture firmware such as CCT presets defined gel presets etc No Preset Activated DMX Color Preset 0 Off DMX 4 7 Color Preset 1 Scratch Pad DMX 8 11 Color Preset 2 Warm White DMX 12 15 Color Preset 3 Cool White Color Preset 4 Daylight DMX 20 23 Color Preset 5 Arc White DMX 24 27 Color Preset 6 Red DMX 28 31 Color Preset 7 Yellow DMX 32 35 Color Preset 8 Daylight Blue DMX 36 39 Color Preset 9 Magenta DMX 40 43 Color Preset 10 Aqua DMX 44 47 Color Preset 11 Medium Amber DMX 48 51 DMX 52 55 Color Preset 13 Blue DMX 56 59 Color Preset 12 Lavender Color Preset 14 Light Pink Color Preset 15 Green DMX 64 67 Color Preset 16 Pink DMX 68 71 Color Preset 17 Amber White DMX 72 75 Color Preset 18 Dark Fuchsia DMX 76 79 Color Preset 19 Light Amber DMX 80 83 Color Preset 20 Steel Blue DMX 84 87 Color Preset 21 Lt Green Blue DMX 88 91 Color Preset 22 Orange DMX 92 95 Color Preset 23 Medium Pink DMX 96 99 Color Preset 24 Cyan DMX 100 103 Color Preset 25 Purple DMX 104 107 Color Preset 26 Custom Color Preset 27 Custom Colo
5. LCD Menu System 15 Installation amp User s Manual PLFRESNEL1 LED Luminaires Menu Structure continued Continued from previous page Settings Sub Menu Options Comments SETTINGS Option Scrolls and sets the various fixture See Settings on page 18 for details settings using arrow buttons Lock Fixture Sub Menu Options Comments Use arrow buttons to make selection Press OK to accept Note a password must be established set in order to lock a fixture Locking the fixture will disable access to changing menu settings LOCK Are you sure Yes to Lock Fixture No Enter Password Sub Menu Options Comments Enter Pass PIN Enter four digit password For details refer to NE A page 16 LED Status Sub Menu Options Comments Displays LED s current status in LED Status Information percentage of Intensity Red Green Blue and White elements of Scrolls through the various levels LED 1 the LED Also displays current color using arrow buttons as indicated on temperature i e WARM WHITE menu screen Depending on the Fan Speed operational LED junction arrow button pressed the screens temperature power settings may appear in a different order that Displays DMX levels for each LED shown in Options Levels element Red Green Blue and White and total power Security Unwanted changes to the Fixture
6. 39 Preset 11 Store DMX 40 41 Preset 12 Store DMX 42 43 Preset 13 Store DMX 44 45 Preset 14 Store DMX 46 47 Preset 15 Store DMX 48 49 Preset 16 Store DMX 50 51 Preset 17 Store DMX 52 53 Preset 18 Store DMX 54 55 Preset 19 Store DMX 56 57 Preset 20 Store DMX 58 59 Preset 21 Store DMX 60 61 Preset 22 Store DMX 62 63 Preset 23 Store DMX 64 65 Preset 24 Store DMX 66 67 Preset 25 Store DMX 68 69 Preset 26 Store DMX 70 71 Preset 27 Store DMX 72 73 Preset 28 Store DMX 74 75 Preset 29 Store DMX 76 77 Preset 30 Store DMX 78 79 Preset 31 Store DMX 80 81 Fixture Reset DMX 250 255 9 Control 0 255 0 100 0 PHILIPS Selecon 8 Bit Mode 23 Installation amp User s Manual PLFRESNEL1 LED Luminaires 3 DMX 3 Channel 3 Chan Mode Table 2 2 provides DMX channel mapping of all DMX512 control values when the PLFRESNEL 1 LED Luminaire is in 3 Channel 3 Chan DMX512 mode as set by the luminaire s menu system Table 2 2 PLFRESNEL1 LED Luminaire DMX Channel Mapping 3 Chan Mode Default DMX recommended GR Channel Parameter Range DMX Range console detault Description values 1 Intensity 0 255 0 100 0 8 bit control for Intensity of LED settings Used to access presets stored in fixture firmware such as CCT presets defined gel presets and more No Preset Activated DMX 0 3 Color
7. Settings 19 Installation amp User s Manual PLFRESNEL1 LED Luminaires DMX CONTROL This section contains information for operating the luminaire using DMX control in 16 Bit 8 Bit or 3 Channel 3 Chan modes For Menu options and detailed information see Settings on page 18 Note These tables assume a DMX start address of 1 When a different starting address is used this address becomes channel 1 function and other functions follow in sequence 16 Bit Mode Table 3 provides DMX channel mapping of all DMX512 control values when the PLFRESNEL1 LED Luminaire is in 16 bit DMX512 mode as set by the luminaire s menu system Table 3 PLFRESNEL1 LED Luminaire DMX Channel Mapping 16 Bit Mode DMX Channel Parameter Intensity High Intensity Low Range DMX 0 65535 Range 0 100 Default recom mended console default values Description 16 bit control for Intensity of LED settings Red High Byte Red Low Byte 0 65535 0 100 16 bit control of Red LEDs from 0 to full Green High Byte Green Low Byte 0 65535 0 100 16 bit control of Green LEDs from 0 to full Blue High Byte Blue Low Byte 0 65535 0 100 16 bit control of Blue LEDs from 0 to full White High Byte ol wo o White Low Byte 0 65535 0 100 16 bit control of White LEDs from 0 to full Preset Color Selection
8. or below that level will be displayed for modification The level can be changed by entering a higher level Password on the Enter PassPIN line directly below the Security heading like Step 4 above Security Levels Security Level Description Default PassPIN 0 System is locked the only key that is active is the Menu ESC Key When this key is pressed a PassPIN is requested Not Applicable All keys are Active You can select any Preset and change Intensity set DMX Address 1111 2 Editing and Saving of Presets is added to Level 1 functionality 2222 3 Operationally the same as level 2 however all settings are available on the Settings screen 3333 Locking Fixture To lock the fixture Step 1 Ata Status Screen press MENU and scroll to Lock Fixture Step 2 Press OK Step 3 Use LEFT ARROW or RIGHT ARROW keys to highlight YES press OK Step 4 Fixture is now locked Note When the Fixture is Locked only the ESC MENU key is functional Pressing this key will display a request for a password When a valid password is entered the fixture is unlocked to the security level of the entered password 4 Presets Presets are Color Mixes that are stored in the Fixture they can be recalled to reproduce a specific output from the fixture Presets are made up of a Color Mix Red Green Blue and White They also have Intensity associated with them Presets can be recalled via t
9. 123 DMX 124 127 DMX 128 131 Not used for future use 20 DMX CONTROL PHILIPS Selecon PLFRESNEL1 LED Luminaires Installation amp User s Manual Table 3 PLFRESNEL1 LED Luminaire DMX Channel Mapping 16 Bit Mode Allows for luminaire timing of intensity Profile should default to DMX 255 for smoothest 13 Intensity Time 0 255 0 100 255 console fade times Refer to PLFRESNEL1 LED Luminaire DMX Timing Channel Detail on page 25 for more information on timing values Allows for luminaire timing of LEDs Profile should default to DMX 255 for smoothest 14 Color Time 0 255 0 100 255 console fade times Refer to PLFRESNEL1 LED Luminaire DMX Timing Channel Detail on page 25 for more information on timing values Used to set different modes parameters and functions of the luminaire Set control channel value for desired action Hold value for at least 3 seconds Set control channel value to O without any scaling Default Setting on Console DMX 0 Display On Off DMX 3 4 Reset All to Defaults DMX 5 7 Quiet Mode DMX 11 13 Normal Mode DMX 14 15 Preset 1 Store DMX 20 21 Preset 2 Store Intensity Only DMX 22 23 Preset 3 Store Intensity Only DMX 24 25 Preset 4 Store Intensity Only DMX 26 27 Preset 5 Store DMX 28 29 Preset 6 Store DMX 30 31 Preset 7 Store DMX 32 33 Preset 8 Store DMX 34 35 Preset 9 Store DMX 36 37 Preset 10 Store D
10. Color Preset 28 Custom DMX 116 119 Color Preset 29 Custom DMX 120 123 Color Preset 30 Custom DMX 124 127 Color Preset 31 Custom DMX 128 131 Allows for timing control of both the intensity and color parameters Channel should default to 255 St E a for smoothest actions using console and or S Timing 0259 E 225 manual fades Refer to PLFRESNEL1 LED Luminaire DMX Timing Channel Detail on page 25 for more information EE PHILIPS 24 DMX CONTROL Selecon PLFRESNEL1 LED Luminaires Installation amp User s Manual 4 PHILIPS Selecon Lighting Console Settings for Preset White 16 Bit Mode Below are the DMX512 console values and levels for Warm White Cool White and Day Light presets in 16 bit mode Red Channel Green Channel Blue Channel White Channel ee DMX bmx ve DS DMX Dmx DAX Dmx Warm White 65535 100 36700 56 0 0 47185 72 Cool White 65535 100 41287 63 8520 13 61603 94 Day Light 65535 100 53739 82 26214 40 58982 90 8 Bit Mode Below are the DMX512 console values and levels for Warm White Cool White and Day Light presets in 8 bit mode Red Channel Green Channel Blue Channel White Channel Kee DMX oe DMX ous DMX ouwen DMX ewe Warm White 3200K 255 100 163 64 0 0 217 85 Cool White 4000K 255 100 194 76 46 18 255 100 Day Light 5600K 255 100 237 93 130 51 255 100
11. LED Luminaire requires very little routine maintenance by the user This section covers portions of the luminaire that can be removed for cleaning The PLFRESNEL1 LED Luminaire special care when it comes to cleaning front lens assembly Additional care needs to be taken with the plastic components because they are much easier to scratch or damage than glass The following is a list of cleaning materials required to care for your PLFRESNEL1 LED Luminaire e Lint free lens tissue e Lint or powder free gloves e Reagent grade isopropyl alcohol e A mild soap solution Note Reagent grade isopropyl alcohol is good to use on the PLFRESNEL1 LED Luminaire optics with anti reflection coatings If the lens is still dirty after using isopropyl alcohol for instance if fingerprints or oil is just redistributed and not cleaned off the optics then a mild soap and water solution can be used to gently wash the lens Repeat the cleaning with isopropyl alcohol to eliminate streaks and soap residue WARNING Under no circumstances should ammonia based cleaners acetone or other harsh solvents be used on or near the PLFRESNEL1 LED Luminaire These types of cleaners or solvents can permanently damage the optics or housings of the fixture If you have any questions regarding the use or care of your PLFRESNEL1 LED Luminaire please contact Philips Selecon technical support or your local Authorized Dealer Service and Maintenance For all
12. Wireless DMX if wireless DMX option is installed sold separately 1 Address 001 to 512 001 DMX512 address Note it can be set if displayed 2 Map 2 When no DMX 8 bit 16 bit or 3 Chan Off Hold Hold 8hr 8 hours or Power Up 16 bit Hold Defines size precision of DMX map Color Mixing Intensity in 16 bit provides higher resolution for precision control 3 Chan provides minimal channel usage If DMX is detected and then goes away this defines what will happen to the output At end of 8Hr hold Fixture goes to Power Up setting Fan 3 Normal Quiet 3 Max Normal or Quiet 0 to 100 Quiet 100 Normal Mode Provides higher cooling margin for thermally challenging applications Recommended for full power RGBW 100 applications with large and numerous changes in power Quiet Quiet Mode Quite Mode is similar to Normal mode but it controls fan tightly to reduce fan noise Sets the maximum fan speed 3 Min 0 to 100 Sets the minimum fan speed Display 3 Flip Display No Yes No Flips inverts Display and Keypad Arrows Note To Exit the Settings screen use the ESC key ESC and OK can be used to cancel or save changes to an individual parameter However once a parameter has been accepted by pressing OK that change cannot be undone canceled by pressing the ESC key Selecon
13. other service and maintenance issues please contact your local Philips Selecon office or an Authorized Service Center WARNING Disassembly other than as described herein alterations unauthorized service etc will void the product warranty Contact your local Philips Selecon office or an Authorized Service Center for technical support and service Accessories Only Philips Selecon approved accessories should be used with your PLFRESNEL1 LED Luminaire For a list of available accessories from Philips Selecon please see Accessories on page 4 For questions regarding accessories please contact your local Authorized Philips Selecon Dealer or Philips Selecon office Special Cleaning and Care Instructions 31 Installation amp User s Manual PLFRESNEL1 LED Luminaires TROUBLESHOOTING 32 1 Troubleshooting Guide The chart below provides possible causes and remedies for various error messages and or symptoms WARNING Any service and maintenance including troubleshooting other than described herein should be A performed by an Authorized Philips Selecon Dealer or Service Center Description Symptom Possible Cause Remedy No light output Fixture will not produce or output light Unit is set to Preset Off Make sure unit is set to proper Preset DMX command to 0 intensity Adjust intensity to higher level No power at luminaire DMX Data Control Luminaire does not
14. power up Fixture will not respond to DMX commands Circuit not energized verify circuit breaker is turned on Not plugged in ensure A C cable is connected to power source Power cable wired incorrectly verify power cable and connector are wired correctly See Connecting Power on page 7 for more information Not detecting DMX data Disconnect and reconnect DMX input cable Unit is not set to be controlled by DMX check menu settings Check all DMX connections at control source and luminaire DMX data cable not wired correctly or has a broken conductor check DMX data cable for proper wiring See Connecting to the DMX512 Network on page 8 for more information LED light is getting dimmer Fixture appears not to be operating at full brightness Luminaire has detected an over temperature condition The luminaire will reduce power to its LED if it senses that the LED is operating over the specified temperature LED temperature is read and recorded through a thermistor imbedded in the LED chip Fan is not operating Listen for fan operation or adjust settings to increase fan speed On luminaires with a display check system status menu for status of fans and LED operation Local programming Unit will not allow local programming or changes Password protection is on locked Input proper password to allow local programming and or adjustments Unit is controlled by DMX Disco
15. various recallable presets values in percent by using the in the fixture using arrow buttons arrow buttons Once the values Cool White are adjusted the preset is saved Note To edit a current set preset as desired see Edit Presets Day Light ay Lig Only intensities may be stored on White Color Temperature presets RGBW in these presets cannot be Preset X 5 through 31 Ha edited or changed Continued next page Note See To navigate and access menu settings selections on page 13 to learn how to access menus To save changes hit OK Press ESC to cancel any changes you made PHILIPS 14 OPERATION AND PROGRAMMING Selecon PLFRESNEL1 LED Luminaires Installation amp User s Manual Menu Structure continued Continued from previous page PHILIPS Selecon Edit a Preset Select Preset to Edit Option Selects a current preset and outputs the preset so preset can be edited Note To save a specific look of the fixture see Save Presets Sub Menu Options Comments Users can Off Edit the current settings look to a Scratch Pad Warm White Cool White Day Light Preset X 5 through 31 specific recallable Preset in the fix ture s memory Edit the values for Red Green Blue White and Intensity values in percent by using the arrow buttons Once the values are adjusted the Save Preset menu option appears to save the ed
16. 2 installation consists of connecting multiple PLFRESNEL1 LED Luminaires together up to 30 luminaires in daisy chain fashion A cable runs from the control console or DMX512 control source to the DMX connector on the first PLFRESNEL1 LED Luminaire Another cable runs from the other DMX connector on the first unit to a DMX connector on the next PLFRESNEL1 LED Luminaire or DMX512 device to be controlled Neutral AC Input Connector on back of unit Main Line Ground Earth Note For more information on DMX512 networking and systems refer to Additional Resources for DMX512 on page 1 For PLFRESNEL1 LED Luminaire DMX Mapping refer to DMX CONTROL on page 20 DMXS5 12 out from first to second luminaire DMXS512 out to the next luminaire or DMX512 controlled device DMX512 CET D from console or control device ER PLFRESNEL1 LED Luminaires DMX512 Connections Data Thru Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Data In Cable Pinout Cable Pinout Common Data Data Not Used Not Used Drain 1 5 2 4 3 Male Conn Female Conn Figure 4 PLFRESNEL1 LED Luminaires DMX512 Connections PHILIPS INSTALLATION AND SET UP Selecon PLFRESNEL1 LED Luminaires Installation amp User s Manual PHILIPS Selecon Mounting WARNING Before attempting any installation or service disconnect all power at power source Dimming the lumina
17. Clamps Part Number Description SC Selecon Molded Yoke rated C Clamp MC Mega Claw Black Anodized PLFRESNEL1 LED Luminaire USB Luminaire Software Cable Part Number Description PLUPLD USB Luminaire Software Programming Kit for updating or reloading luminaire software only include USB to DMX dongle Uploader Program and Carry Bag PLFRESNEL1 LED Luminaire Top Box Assembly 4 PREFACE Part Number Description PLICB Spare Top Box Interconnect Assembly PHILIPS Selecon PLFRESNEL1 LED Luminaires Installation amp User s Manual PLFRESNEL1 LED LUMINAIRE OVERVIEW 1 PLFRESNEL1 LED Luminaire Components Major Luminaire Components Top Box Assembly PLICB AC Input Thru and DMX In Out Connections Ge Yoke Locking Handle Accessory Holder with latching door Rear of Unit Multi Conductor Fixture Connection Safety Cable Anchor Point LCD Display Menu System Beam Spot Flood Adjustment For the LCD Display Menu System refer to LCD Display Menu System on page 6 for more information Figure 1 PLFRESNEL1 LED Luminaire Components PHILIPS Selecon PLFRESNEL1 LED Luminaire Components 5 Installation amp User s Manual PLFRESNEL1 LED Luminaires Top Box PLICB Luminaire Connections DMX512 Input Side View 1 AC Power Input Multi Conductor Top Box to Luminaire Conn
18. D Luminaires 26 DMX CONTROL Table 3 PLFRESNEL1 LED Luminaire Timing Channel Detail Value DMX Seconds 0 0 Full Speed 1 0 2 2 0 4 1 3 0 6 4 0 8 2 5 1 6 1 2 7 1 4 3 8 1 6 9 1 8 4 10 2 11 2 2 12 2 4 5 13 2 6 14 2 8 6 15 3 16 3 2 17 3 4 7 18 3 6 19 3 8 8 20 4 21 4 2 22 4 4 9 23 4 6 24 4 8 10 25 5 26 5 2 27 5 4 11 28 5 6 29 5 8 30 6 12 31 6 2 32 6 4 13 33 6 6 34 6 8 35 7 0 14 36 7 2 37 7 4 15 38 7 6 39 7 8 40 8 16 41 8 2 42 8 4 17 43 8 6 44 8 8 45 9 18 46 9 2 47 9 4 19 48 9 6 49 9 8 50 10 20 51 10 2 PHILIPS Selecon PLFRESNEL1 LED Luminaires Installation amp User s Manual Value DMX Seconds 52 10 4 53 10 6 21 54 10 8 55 11 22 56 11 2 57 11 4 58 11 6 23 59 11 8 60 12 24 61 12 2 62 12 4 63 12 6 25 64 12 8 65 13 26 66 13 2 67 13 4 68 13 6 27 69 13 8 70 14 28 71 14 2 72 14 4 73 14 6 29 74 14 8 75 15 30 76 15 2 77 15 4 78 15 6 31 79 15 8 80 16 81 16 2 32 82 16 4 83 16 6 33 84 16 8 85 17 86 17 2 34 87 17 4 88 17 6 35 89 17 8 90 18 91 18 2 36 92 18 4 93 18 6 37 94 18 8 95 19 96 19 2 38 97 19 4 98 19 6 39 99 19 8 100 20 101 21 40 102 22 103 23 104 24 41 105 25 PHILIPS SE PLFRESN
19. EL1 LED Luminaire DMX Timing Channel Detail 27 Selecon Installation amp User s Manual PLFRESNEL1 LED Luminaires 28 DMX CONTROL Value DMX Seconds 106 26 42 107 27 108 28 109 29 43 110 30 111 31 44 112 32 113 33 114 34 45 115 35 116 36 46 117 37 118 38 119 39 47 120 40 121 41 48 122 42 123 43 124 44 49 125 45 126 46 127 47 50 128 48 129 49 51 130 50 131 51 132 52 52 133 53 134 54 53 135 55 136 56 137 57 54 138 58 139 59 55 140 60 141 61 142 62 56 143 63 144 64 57 145 65 146 66 147 67 58 148 68 149 69 59 150 70 151 71 152 72 60 153 73 154 74 155 75 61 156 76 157 77 62 158 78 159 79 PHILIPS Selecon PLFRESNEL1 LED Luminaires Installation amp User s Manual Value DMX Seconds 160 80 63 161 81 162 82 64 163 83 164 84 165 85 65 166 86 167 87 66 168 88 169 89 170 90 67 171 91 172 92 68 173 93 174 94 175 95 69 176 96 177 97 178 98 70 179 99 180 100 7 181 101 182 102 183 103 72 184 104 185 105 73 186 106 187 107 188 108 74 189 109 190 110 75 191 111 192 112 193 113 76 194 114 195 115 77 196 116 197 117 198 118 78 199 119 200 120 79 201 121 202 122 203 123 80 204 124 205 125 81 206 126 207 127 208 128 82 209 129 210 130 211 131 83 212 132 213 133 P
20. EN er NO Me Men EE Aen Ee ee e 9 Using Supplied E 9 Satety Cable RE 9 Pan nd Tilt CO En SE 10 Pan Ee 10 Ru EE UE EE 10 BEAM ADJUSTMENTS Beam Adjustment ere ees 11 Barndoor Assembly E 11 OPERATION AND PROGRAMMING ECD Ment Operation israse 200 EES eech EENEG 12 ECD TEE EE 13 IY 2410111229222222 4 O E A 14 SOCUFILY E 16 Passwords ennenen a E E RE EE A E A E e 16 Security LOVES EE 17 Locking EE 17 LS 17 Presets TYPES ne sonne dE EES 17 Editing Preset Names secs 6253 2002432204p022p 40063 Uevassdoesversbaceslenshuleoscsoasuescscdeetudessenendboesedecoudeioesbsbanesvsectuacaacaeebedes 18 E EE 18 PHILIPS 2 Meera Selecon PLFRESNEL1 LED Luminaires Installation amp User s Manual DMX CONTROL MG Bit LR E A A E E 20 8 Bit Modes sassis siiicar eta 22 DMX 3 Channel 3 Chan Mode 24 Lighting Console Settings for Preset White ser 25 PLFRESNEL1 LED Luminaire DMX Timing Channel Detail 25 CLEANING AND CARE Special Cleaning and Care Instructpong ss 31 GEESS LES 0 12 19 al A A ciate a A R 31 ACCESS OPIES es e Deeg EE Ee E E Ae E 31 TROUBLESHOOTING Troubleshooting Gide drames lien kece EeEEEE 32 TECHNICAL SPECIFICATIONS PLFRESNEL1 LED Luminaire Operational Specifications 0 0 ceceesssesecseeeceeceseteeeecsecneeaeessesecaeeaesaeeaeeasetees 33 PLFRESNEL1 LED Luminaire Dimensions seen 33 PHILIPS Selecon Installation amp User s Manual PLFRESNEL1 LED Luminaires PREFACE 1 About this Manual The document provid
21. HILIPS PLFRESNEL1 LED Luminaire DMX Timing Channel Detail 29 Selecon Installation amp User s Manual PLFRESNEL1 LED Luminaires 30 Value DMX Seconds 84 214 134 215 135 216 136 85 217 137 218 138 86 219 139 220 140 221 141 87 222 142 223 143 88 224 144 225 145 226 146 89 227 147 228 148 229 149 90 230 150 231 151 91 232 152 233 153 234 154 92 235 155 236 156 93 237 157 238 158 239 159 94 240 160 241 161 95 242 162 243 163 244 164 96 245 165 246 166 97 247 167 248 168 249 169 98 250 60mS 251 80mS 99 252 100mS 253 120mS 254 140mS 100 Beet 160mS Note DMX values 250 to 255 provide smoothing when using console fade timing DMX value 255 recommended default will provide the smoothest timing DMX CONTROL PHILIPS Selecon PLFRESNEL1 LED Luminaires Installation amp User s Manual CLEANING AND CARE A PHILIPS Selecon WARNING All cleaning should be performed with power completely removed from the luminaire Never remove protective covers when luminaire is powered Wear appropriate protective eye wear and gloves when cleaning the fixture All service and maintenance other than described herein should be performed by a qualified technician or Authorized Service Center Special Cleaning and Care Instructions Being a solid state fixture and unlike most fixtures the PLFRESNEL1
22. HILIPS PLFRESNEL1 LED Luminaire Operational Specifications 33 Selecon PHILIPS Selecon Philips Selecon Dallas 10911 Petal Street Dallas TX 75238 Tel 1 214 647 7880 Fax 1 214 647 8031 Philips Selecon New York 267 5th Ave 4th Floor New York NY 10016 Tel 1 212 213 8219 Fax 1 212 532 2593 Philips Selecon Hong Kong Unit C 14 F Roxy Industrial Centre No 41 49 Kwai Cheong Road Kwai Chung N T Hong Kong Tel 852 2796 9786 Fax 852 2798 6545 Philips Selecon Auckland 19 21 Kawana Street Northcote Auckland 0627 New Zealand Tel 64 9 481 0100 Fax 64 9 481 0101 Philips Selecon Europe Rondweg zuid 85 Winterswijk 7102 JD The Netherlands Tel 31 0 543 542516 www seleconlight com 2013 Philips Group
23. MANUAL SER S U e LA TALLATION INS Selecon PLFRESNEL1 LED Luminaires Philips Selecon Offices Philips Selecon Dallas Philips Selecon Auckland 10911 Petal Street 19 21 Kawana Street Dallas TX 75238 Northcote Auckland 0627 Tel 1 214 647 7880 New Zealand Fax 1 214 647 8030 Tel 64 9 481 0100 Fax 64 9 481 0101 Philips Selecon New York Philips Selecon Europe 267 Sth Ave 4th Floor Rondweg zuid 85 New York NY 10016 Winterswijk 7102 JD Tel 1 212 213 8219 The Netherlands Fax 1 212 532 2593 Tel 31 0 543 542516 Philips Selecon Asia Limited Unit C 14 F Roxy Industrial Centre No 41 49 Kwai Cheong Road Website Kwai Chung N T Hong Kong www seleconlight com Tel 852 2796 9786 Fax 852 2798 6545 The material in this manual is for information purposes only and is subject to change without notice Philips Selecon assumes no responsibility for any errors or omissions which may appear in this manual For comments and suggestions regarding corrections and or updates to this manual please visit the Philips Selecon web site at www seleconlight com or contact your nearest Philips Selecon office El contenido de este manual es solamente para informaci n y est sujeto a cambios sin previo aviso Philips Selecon no asume responsabilidad por errores 0 omisiones que puedan aparecer Cualquier comentario sugerencia o correcci n con respecto a este manual favor de dirijirlo a la oficina de Philips
24. MX 38 39 15 Control 0 255 0 100 0 Preset 11 Store DMX 40 41 Preset 12 Store DMX 42 43 Preset 13 Store DMX 44 45 Preset 14 Store DMX 46 47 Preset 15 Store DMX 48 49 Preset 16 Store DMX 50 51 Preset 17 Store DMX 52 53 Preset 18 Store DMX 54 55 Preset 19 Store DMX 56 57 Preset 20 Store DMX 58 59 Preset 21 Store DMX 60 61 Preset 22 Store DMX 62 63 Preset 23 Store DMX 64 65 Preset 24 Store DMX 66 67 Preset 25 Store DMX 68 69 Preset 26 Store DMX 70 71 Preset 27 Store DMX 72 73 Preset 28 Store DMX 74 75 Preset 29 Store DMX 76 77 Preset 30 Store DMX 78 79 Preset 31 Store DMX 80 81 Fixture Reset DMX 250 255 PHILIPS ee Selecon 16 Bit Mode 21 Installation amp User s Manual PLFRESNEL1 LED Luminaires 2 8 Bit Mode Table 2 1 provides DMX channel mapping of all DMX512 control values when the PLFRESNEL 1 LED Luminaire is in 8 bit DMX512 mode as set by the luminaire s menu system Table 2 1 PLFRESNEL1 LED Luminaire DMX Channel Mapping 8 Bit Mode DMX Channel Parameter Intensity Range DMX 0 255 Range 0 100 Default recommended console default values 0 Description 8 bit control for Intensity of LED settings Red 0 255 0 100 8 bit control of Red LEDs from 0 to full Green 0 255 0 100 8 bit control of Green LEDs from 0 to full Blue
25. Preset 0 Off DMX 4 7 Color Preset 1 Scratch Pad DMX 8 11 Color Preset 2 Warm White DMX 12 15 Preset Color Selection Color Preset 3 Cool White DMX 16 19 Color Preset 4 Daylight DMX 20 23 Notes Color Preset 5 Arc White DMX 24 27 Color Preset 6 Red DMX 28 31 Color Preset 7 Yellow DMX 32 35 Ee o Color Preset 8 Daylight Blue DMX 36 39 colors and can be Color Preset 9 Magenta DMX 40 43 reloaded if needed Color Preset 10 Kelly Green DMX 44 47 through the fixture s Color Preset 11 Medium Amber DMX 48 51 menu system Color Preset 12 Lavender DMX 52 55 2 0 255 0 100 0 Color Preset 13 Blue DMX 56 59 These colors have Color Preset 14 Light Pink DMX 60 63 been matched to Color Preset 15 Green DMX 64 67 precise X and Y Color Preset 16 Pink DMX 68 71 coordinates at the Color Preset 17 Amber White DMX 72 75 center of the beam Color Preset 18 Dark Fuchsia DMX 76 79 at wide angle we Color Preset 19 Light Amber DMX 80 83 have given you the Color Preset 20 Steel Blue DMX 84 87 ability to adjust Color Preset 21 Lt Green Blue DMX 88 91 these colors as Color Preset 22 Orange DMX 92 95 your personal per Color Preset 23 Medium Pink DMX 96 99 ception may vary Color Preset 24 Cyan DMX 100 103 Color Preset 25 Purple DMX 104 107 Color Preset 26 Custom DMX 108 111 Color Preset 27 Custom DMX 112 115
26. Selecon m s cercana Der Inhalt dieses Handbuches ist nur fiir Informationszwecke gedacht Aenderungen sind vorbehalten Philips Selecon uebernimmt keine Verantwortung fiir Fehler oder Irrtuemer die in diesem Handbuch auftreten F r Bemerkungen und Verbesserungsvorschlaege oder Vorschlaege in Bezug auf Korrekturen und oder Aktualisierungen in diesem Handbuch moechten wir Sie bitten Kontakt mit der naechsten Philips Selecon Niederlassung aufzunehmen Le mat riel d crit dans ce manuel est pour information seulement et est sujet changements sans pr avis La compagnie Philips Selecon n assume aucune responsibilit sur toute erreur ou ommission inscrite dans ce manuel Pour tous commentaires ou suggestions concernant des corrections et ou les mises jour de ce manuel veuillez s il vous plait contacter le bureau de Philips Selecon le plus proche Note Information contained in this document may not be duplicated in full or in part by any person without prior written approval of Philips Selecon Its sole purpose is to provide the user with conceptual information on the equipment mentioned The use of this document for all other purposes is specifically prohibited Document Number 02 9701 0001 Version as of 20 February 2013 PLFRESNEL1 LED Luminaire Installation amp User s Manual 2013 Philips Group All rights reserved PLFRESNEL1 LED Luminaires Installation amp User s Manual IMPORTANT INFORMATION Warnings and Notic
27. afety cable to safety cable anchor point as shown and attach to structure Safety Cable supplied with luminaire Safety Cable Anchor Point Yoke Assembly Cooling Vents see note below T Handle Tilt Lock Sliding Yoke Assembly NOTE To allow for proper cooling make sure luminaire head is orientated as shown with forward cooling vents pointed upwards Figure 6 Luminaire Tilt Adjustment To adjust and set tilt angle of the luminaire Step 1 Mount luminaire in desired location see Mounting on page 9 for more information Step 2 Loosen but do not remove T Handle Tilt Lock at base of yoke assembly as shown in Figure 6 Step 3 Position luminaire to desired tilt position Step 4 Retighten T Handle Tilt Lock to set position PHILIPS INSTALLATION AND SET UP Selecon PLFRESNEL1 LED Luminaires Installation amp User s Manual BEAM ADJUSTMENTS 1 Beam Adjustments To adjust the beam on the Step 1 As shown in Figure 7 loosen Beam Adjustment Knob Step 2 Slide beam adjustment back for spot or forward for flood as desired Step 3 Hand tighten Beam Adjustment Knob to lock position Beam Adjustment Knob i Spot lt gt Flood Figure 7 Zoom and Focus Adjustment Knobs 2 Barndoor Assembly Philips Selecon offers as an optional accessory a four leaf barndoor assembly Th
28. at the circuit breaker or remove the fuse to avoid shock or damage to the control It is recommended that a qualified electrician perform this installation Additional Resources for DMX512 For more information on installing DMX512 control systems the following publication is available for purchase from the United States Institute for Theatre Technology USITT Recommended Practice for DMX512 A Guide for Users and Installers 2nd edition ISBN 9780955703522 USITT Contact Information USITT 315 South Crouse Avenue Suite 200 Syracuse NY 13210 1844 Phone 1 800 938 7488 or 1 315 463 6463 www usitt org Philips Selecon Limited Three Year Warranty Philips Selecon offers a three year limited warranty of its luminaires against defects in materials or workmanship from the date of delivery A copy of the Philips Selecon three year limited warranty containing specific terms and conditions can be obtained from the Philips Selecon web site at www seleconlight com or by contacting your local Philips Selecon office PLFRESNEL1 LED Luminaire powerful LED engine offers exceptional performance and life Under normal operating conditions our LED engine has a life expectancy in excess of 50 000 hours however under worst case operating conditions with the luminaire set to continuous full output it is possible that a small percentage of LED s may require replacement sooner The Philips Selecon three year limited warranty includes our guarantee against pre
29. aximum power supply limit of 150 Watts Do not overload circuits 2 Connecting Power Units can be powered in one of two ways Direct connection to a AC power source using an AC input cable Daisy chain connection using a interconnect AC cable IMPORTANT AC POWER CONNECTION NOTES A a When using the daisy chain connection method ONLY connect PLFRESNEL1 LED Luminaires to AC Output Connection of PLFRESNEL1 LED Luminaires DO NOT CONNECT OTHER TYPES OF LUMINAIRES OR DEVICES Use only use approved cable types Do not overload circuits Do not connect PLFRESNEL1 LED Luminaires to dimmed circuits The MAXIMUM allowable number of PLFRESNEL1 LED Luminaires which can be daisy chained on one power feed are listed in Table 1 above DO NOT EXCEED G If the unit is supplied with an AC input cable but you did not order an AC input connector Table 2 on page 8 describes how to connect power to your PLFRESNEL1 LED Luminaire Field wiring of the PLFRESNEL1 LED Luminaire is straight forward A total of 3 wires conductors need to be brought to the unit The following wiring scheme is required PHILIPS Selecon Power Requirements 7 Installation amp User s Manual PLFRESNEL1 LED Luminaires Table 2 PLFRESNEL1 LED Luminaire AC Input Connections Wire Color Purpose Brown Main Line 120 to 240VAC Blue Neutral Green Yellow Ground Connecting to the DMX512 Network Basic DMX51
30. ection DMX512 Output Thru Multi Conductor Top Box to Luminaire Connection FEN X Side View 2 AC Power Output Figure 2 Top Box PLICB Connections LCD Display Menu System PRESET INTENSITY 1 LCD Display Menu System 2 Preset Intensity Menu Access Buttons 3 Function Menu System Select Push Buttons Note For Menu operation and programming details refer to LCD Menu Operation on page 12 Figure 3 PLFRESNEL1 LED Luminaire LCD Display amp Menu System PLFRESNEL1 LED LUMINAIRE OVERVIEW PHILIPS Selecon PLFRESNEL1 LED Luminaires Installation amp User s Manual INSTALLATION AND SET UP 1 Power Requirements The PLFRESNEL1 LED Luminaire operates on 100 to 240 volts AC 10 auto ranging The luminaire contains an auto ranging power supply Depending on supply voltage each luminaire can draw up to 1 5 amps Table 1 PLFRESNEL1 LED Luminaire Voltage vs Current Maximum Maximum Voltage Total R DUT De gla Voltage Total GE oe AC Current A be linked AC Current A be linked together together 100 1 50 13 180 0 83 24 110 1 36 14 190 0 79 25 120 1 25 16 200 0 75 26 130 1 15 17 210 0 71 28 140 1 07 18 220 0 68 29 150 1 00 20 230 0 65 30 160 0 94 21 240 0 63 32 170 0 88 22 WARNING These figures are based on the Maximum Allowable Input Current of 20 Amps and the m
31. es When using electrical equipment basic safety precautions should always be followed including the following a READ AND FOLLOW ALL SAFETY INSTRUCTIONS AN Do not use outdoors Do not mount near gas or electric heaters aes Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel e The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition f Do not use this equipment for other than intended use This equipment is not for residential installation or use g Refer service to qualified personnel SAVE THESE INSTRUCTIONS WARNING You must have access to a main circuit breaker or other power disconnect device A before installing any wiring Be sure that power is disconnected by removing fuses or turning the main circuit breaker off before installation Installing the device with power on may expose you to dangerous voltages and damage the device A qualified electrician must perform this installation WARNING Refer to National Electrical Code and local codes for cable specifications Failure to use proper cable can result in damage to equipment or danger to personnel WARNING This equipment is intended for installation in accordance with the National Electric Code and local regulations It is also intended for installation in indoor applications only Before any electrical work is performed disconnect power
32. es installation and operation instructions for the following products e PLFRESNEL1 LED Luminaire PLFR1 03 Please read all instructions before installing or using this product Retain this manual for future reference Additional product information and descriptions may be downloaded at www seleconlight com Note All PLFRESNEL1 LED Luminaires are universal voltage 100VAC to 240VAC Auto ranging 2 Accessories Contact your Authorized Philips Selecon Dealer for price and availability of all accessories for PLFRESNEL1 LED Luminaires Additional information can be found on the Philips Selecon web site at www seleconlight com PLFRESNEL1 LED Luminaire Power Input Cables Part Number Description PLFRESNEL1 LED Luminaire AC Power Input Cable 39 inches 1 meter Powercon without SSES Connector user to supply AC connector PLFRESNEL1 LED Luminaire AC Power Input Cable 39 inches 1 meter Powercon with Stagepin PC1GP Connector PLFRESNEL1 LED Luminaire AC Power Input Cable 39 inches 1 meter Powercon with Twistlock PC1GTL Connector PLFRESNEL1 LED Luminaire AC Power Input Cable 39 inches 1 meter Powercon with Edison PC1GR Connector PC3PC PLFRESNEL1 LED Luminaire PowerCon Male to PowerCon Female 2 5 Meter Cable for interconnection between units PLFRESNEL1 LED Luminaire Lens Accessories Part Number 20BDMF Description Acclaim Fresnel Barndoor 4 Way Black PLFRESNEL1 LED Luminaire
33. he User interface or by a DMX channel when under DMX control The Preset s Intensity is applied if the User Interface is used if DMX the DMX Intensity channel is used for Intensity Presets Types Presets are classified as Locked Protected or User The type of preset determines what aspects of the Preset can be modified Locked Locked Presets are factory Calibrated and their Color Mix cannot be changed by the user Their Intensity can be changed Three Presets 2 4 Warm White Cool White and Day Light are Locked PHILIPS Selecon Presets 17 Installation amp User s Manual PLFRESNEL1 LED Luminaires Preset 0 the off preset is also Locked to the OFF value Protected Protected Presets are also Factory Calibrated and by default are Protected from changes to their Color Mix Their Intensity can be changed Protected Presets are Presets 5 25 They can be Un Protected by setting Protected to No see section on Settings If Un Protected these presets function like User Presets The Factory Calibrated values for the protected presets can be re loaded to the original factory calibration settings by setting Load Factory to Yes see section on Settings User User Presets can have their Color Mix and Intensity changed without restriction Note If the Color Mix of a Factory Calibrated Preset is changed by turning protection Off an is appended to the end of the Preset s Name to indicate that the Calibra
34. ire does not disconnect power Installation and service should only be performed by a trained and qualified professional Using Supplied C Clamp As illustrated in Figure 5 at yoke assembly thread clamp mounting bolt with washer installed through center clamp mounting hole at top of yoke through Top Box Assembly and thread bolt into C Clamp Securely tighten bolt by hand into clamp but do not overtighten C Clamp Top Box Assembly Center Clamp Mounting Hole 13 mm Flat Washer WARNING When installing a C Clamp or hook s or other type of clamp with the Top Box Assembly C Clamp Bolt as shown you MUST use the C Clamp Bolt supplied with the fixture Failure to do so may result in damage to the Top Box Assembly or cause the luminaire to dislodge from the clamping device Yoke Assembly Top Box Assembly Luminaire Cable Assembly NOTE To allow for proper cooling make sure luminaire head is orientated as shown with forward cooling vents pointed upwards Figure 5 Luminaire Mounting To mount on a telescopic stand reverse the yoke under the luminaire and bolt to stand Please note luminaire orientation see note in Figure 5 for proper cooling Note After installing Clamp and Top Box assembly connect luminaire cable assembly to Top Box Assembly before mounting luminaire Please note that the cable connector is keyed Safety Cable Use The supp
35. is assembly is sold separately and available from your Authorized Philips Selecon Authorized Dealer For information on all available accessories for the PLFRESNEL1 LED Luminaire refer to Accessories on page 4 PHILIPS Selecon Beam Adjustments 11 Installation amp User s Manual PLFRESNEL1 LED Luminaires OPERATION AND PROGRAMMING 1 LCD Menu Operation The PLFRESNEL1 LED Luminaire s LCD Display and Menu System provides local control for accessing all the fixture s status information menu options and settings Note If there are multiple luminaires in a system changes would need to be made at each LCD Menu as desired Upon power up the LCD will display the main screen showing the product type name If DMX is enabled the programmed address will appear after power up LCD Display r Escape Button Displays all menu parameters and Enters menu options Navigates option settings Also displays DMX512 backs up one menu level address DMX models only PHILIPS Salecon PRESET Button gt O Allows the recall of stored presets PRESET INTENSITY MENU INTENSITY Button Allows the customization of current intensity light output Note using the LEFT and RIGHT arrow buttons you can select each RGBW channel individually and change their intensity using the UP Up Down Left Right Arrow Buttons and DOWN arrows Navigates menu system and used for selecting and set
36. its NOTES Only intensities may be stored on White Color Temperature presets RGBW in these presets cannot be edited or changed If a Calibrated Preset s Color Mix is changed 5 thru 25 an asterisk is appended to the end of the name to indicate that it has been modified This only happens if the name matches the original calibrated name stored in EEPROM This does not happen if the Intensity is changed only the color mix Note When DMX512 signal is present Edit a Preset option will not appear in menu structure Color Mix Sub Menu Options Comments Red Green Users can Edit Red Green Blue White and Select Color or Intensity to Adjust Blue Intensity values in percent by Option using the arrow buttons j Once the values are adjusted White press OK to save the edits Intensity Note When DMX512 signal is present Color Mix option will not appear in menu structure Fan Control Continued next page Sub Menu Options Comments Highlight Max button and hit OK Max button on menu Sets the maximum speed of the fan Select and Set Fan Speed Option p Option Level sets the fan to a constant speed Note hit Cancel to cancel any will not vary Adjust level on fan changes you made Level speed level bar using Left and Right arrow buttons highlight Level button in menu and hit OK on menu to use user defined level
37. lied safety cable MUST always be used when rigging luminaires on bars truss etc as shown in Figure 6 The supplied safety cable is recommended for all hanging installation and may be required by national and local Mounting 9 Installation amp User s Manual PLFRESNEL1 LED Luminaires 10 codes Loop or attach safety cable to luminaire safety cable anchor point as shown and attach to structure You should always consult and follow all local and national codes and regulations for mounting and installation of luminaire Pan and Tilt Adjustments Pan Adjustment The pan adjustment of a PLFRESNEL1 LED Luminaire is achieved by loosening the yoke bolt of the securing clamp attached to the luminaire s yoke assembly Loosen the bolt set the luminaire to the desired position and retighten Tilt Adjustment PLFRESNEL1 LED Luminaires offer variable tilt settings The unit can be set at a specific angle in relation to its mounting position or at an angle between 0 to 90 degrees When the yoke is in the position shown in Figure 6 you have full range access to shutters the gate etc If you flip the yoke over some access is reduced but the over all volume the luminaire takes up is reduced This is particularly useful in tightly hung lighting positions or in theatres with low grids SAFETY CABLE FOR LUMINAIRE the supplied safety cable is recommended for all hanging installation and may be required by national and local codes Loop attach s
38. mature failure of the LED engine PHILIPS Selecon Installation amp User s Manual PLFRESNEL1 LED Luminaires TABLE OF CONTENTS Philips Selecon Offices edd dee edd NENNEN thas 0 IMPORTANT INFORMATION Warnings and NOtIceS sciencies e a a E ESEESE KSEE RE AE ORERE ESE SEE AAEE Aer EEEE 1 Additional Resources for DM XI 1 Philips Selecon Limited Three Year Warranty ss 1 TABLE OF CONTENTS PREFACE e n EE EE 4 FESES u ES ET 4 PLFRESNEL1 LED Luminaire Power Input Cables AA 4 PLFRESNEL1 LED Luminaire Lens Accessortes ss 4 PLFRESNEL1 LED Lamminatre Clamips s i cci cc s cciceccecsectesssistecscneenssessveesousneunessevenscteesciecerveesbtaeesvesutestsvendens 4 PLFRESNEL1 LED Luminaire USB Luminaire Software Cable 00 0 ececceceesescnecseeeeeseceeeeeeeceaeaeeeceeaenees 4 PLFRESNEL1 LED Luminaire Top Box Assembly ss 4 PLFRESNEL1 LED LUMINAIRE OVERVIEW PLFRESNEL1 LED Luminaire Components ss 5 Major Luminaire Components 6 68 secesceasesesessosessoteossveisnecsceussnnseonenslosbsoshesdebocssldsvovscheVesdayernebecuatesseServens 5 Top Box PLICB Luminaire Connections sise 6 LCD Display Menu Sy Sten lin Ulnugeadresacs seveoenubsabivonyade svabschussauiyedboneanaesssveaveus 6 INSTALLATION AND SET UP Power E TE EE H COMMEG tT POW Cli ccs cases cainccadoneqaaetecegs aces tueseeandctecavesecetacetansese ces sn ne ne sem se ee tetes tdi machant de 7 Connecting to the DMX512 Networksin neeo ret ae nets tentera sien ent sq 8 Mounting
39. nnect input cables to check issue TROUBLESHOOTING PHILIPS Selecon PLFRESNEL1 LED Luminaires Installation amp User s Manual TECHNICAL SPECIFICATIONS 1 PLFRESNEL1 LED Luminaire Operational Specifications Source True RGBW 120 Watt LED chip Light Output gt 2 000 lumens Beam Angle 15 to 54 Degrees user adjustable Color Temperature 3000 5600K user adjustable Power Consumption 150 Watts max RGBW at 100 Input Voltage 120V to 240V 10 auto ranging Current 1 3Amps 115V 0 65 Amps 230V Frequency 50 60Hz Ambient Temperature 0 to 40 degrees C 32 to 104 degrees F Humidity 5 95 Non condensing Cooling Forced Air Weight 12 3 lbs 5 6 kg Luminaire only no mount AC input cable or accessories Compliance ETL cETL Listed North America models and CE Marked International models Note Common model specifications shown For specific model specifications features and accessories refer to the product specification sheet or visit the Philips Selecon web site at www seleconlight com for more details 2 PLFRESNEL1 LED Luminaire Dimensions 444 8 mm 17 5 in 7 208 3 mm 8 2 in wa E 249 6 mm 9 8 in 341 9 mm E 13 5 in UU P
40. r Preset 28 Custom Color Preset 29 Custom Color Preset 30 Custom Color Preset 31 Custom 0 3 DMX 16 19 DMX 60 63 DMX 108 111 DMX 112 115 DMX 116 119 DMX 120 123 DMX 124 127 DMX 128 131 Not used for future use Timing 0 255 0 100 255 Allows for timing control of both the intensity and color parameters Channel should default to 255 for smoothest actions using console and or manual fades Refer to PLFRESNEL1 LED Luminaire DMX Timing Channel Detail on page 25 for more information 22 DMX CONTROL PHILIPS Selecon PLFRESNEL1 LED Luminaires Installation amp User s Manual Table 2 1 PLFRESNEL1 LED Luminaire DMX Channel Mapping 8 Bit Mode Used to set different modes parameters and functions of the luminaire Set control channel value for desired action Hold value for at least 3 seconds Set control channel value to O without any scaling Default Setting on Console DMX 0 Display On Off DMX 3 4 Reset All to Defaults DMX 5 7 Quiet Mode DMX 11 13 Normal Mode DMX 14 15 Preset 1 Store DMX 20 21 Preset 2 Store Intensity Only DMX 22 23 Preset 3 Store Intensity Only DMX 24 25 Preset 4 Store Intensity Only DMX 26 27 Preset 5 Store DMX 28 29 Preset 6 Store DMX 30 31 Preset 7 Store DMX 32 33 Preset 8 Store DMX 34 35 Preset 9 Store DMX 36 37 Preset 10 Store DMX 38
41. s Configuration or Setting can be controlled by setting a security level or Locking the Fixture Three levels of security are available in addition to completely Locking the Fixture PLFRESNEL1 LED Luminaires are shipped with default passwords Users may set their own password four digit number When setting a password write it down and keep it in a secure location Note Philips Selecon does not have records of passwords established by users or owners Note Contact Philips Selecon technical support if a unit is locked and the password is lost for instructions on how to reset luminaire Note If the Fixture is locked when it is powered down the fixture will remain in the locked state when powered up Passwords Establishing or Changing Passwords Step 1 Ata Status Screen press MENU and scroll to Settings press OK Step 2 Go to the Security section PHILIPS 16 OPERATION AND PROGRAMMING Selecon PLFRESNEL1 LED Luminaires Installation amp User s Manual Step 3 Select a Level to change Level 1 PIN Level 2 PIN Level 3 PIN Step 4 Press OK to edit using the UP ARROW DOWN ARROW LEFT ARROW or RIGHT ARROW keys to enter a four digit password using 0 to 9 Step 5 Press OK to save changes If you hit ESC Escape password will not be stored and process must be repeated Step 6 Password is set Note The current security level is displayed next to the Security heading Only Passwords at
42. ted values have been changed Editing Preset Names On the Edit Preset screen the option is available to edit the name of a preset via Screen button However the names of Presets 0 4 cannot be edited Use the LEFT ARROW and RIGHT ARROW keys to select the character to be changed and use the UP ARROW and DOWN ARROW keys to change that character The Character Scroll order is A Z space 0 9 If you are scrolling up the Alpha character displays as Upper Case if you are scrolling down the Alpha character displays as Lower Case Stop on the character you want ignoring case then press the opposite UP ARROW or DOWN ARROW key if you want to change the case OK to save changes ESC to cancel changes Settings The following Parameters can be changed on the Settings Screen The first column Security Level is the minimum security level you have to be at before the line is displayed for editing in the Settings screen To edit a value on the Setting Screen use the UP ARROW or DOWN ARROW keys to move the highlight to the settings value you wish to change Press OK to begin editing that value Use the UP ARROW DOWN ARROW LEFT ARROW or RIGHT ARROW keys to make changes to the value Press OK when complete to save changes or ESC to cancel changes to that value When done making changes on the Settings Screen press ESC to re boot fixture and implement changes Fixture will not re boot if nothing was changed
43. ting options OK Enter Button Accesses details activates a field or enters a setting depending on the current menu item Figure 8 LCD Display and Menu System RE PHILIPS 12 OPERATION AND PROGRAMMING Selecon PLFRESNEL1 LED Luminaires Installation amp User s Manual 2 LCD Menu System The LCD Display Menu system consists of several categories Use the four arrow buttons as required refer to Figure 8 on page 12 to access and make changes to the menu items When the desired menu item is reached press OK to display the menu options Use navigation and OK buttons to view status and configure the LCD Menu as required Note Depending on the security settings certain menu items may be password protected You must have the set PassPIN in order to access these items Locked items will have a Key icon displayed next to them To navigate and access menu settings selections Step 1 At Main Menu press ESC MENU button once A small window will appear over Main Menu with sub menu categories Save as Preset Edit a Preset Color Mix Fan Control Settings Lock Fixture g Enter Password h LED Status Step 2 Press OK at desired menu item to access and make changes gt o Q 0 O D Step 3 Make changes as desired Note For complete menu structure and available options see Menu Structure continued on page 15 Note When DMX512 signal is present Edit Preset and Color Mix op
44. tions will not appear in menu structure To navigate fixture status menus Step 1 At Main Menu press LEFT or RIGHT arrow button once Main menu screen will change to fixture status screen will appear as follows note depending on which arrow button is pressed status screens may appear in reverse order a DMX Address note if fixture is UNLOCKED hit OK to change DMX address b Fixture Hours displays fixture operating hours since last reset c Fixture Power displays Max Power Limit setting in Watts Present Power consumed by fixture in Watts and Hours of Use d Fixture Status displays current operational temperature LED status and fan speed setting Step 2 Press LEFT or RIGHT arrow buttons to scroll through status screens Step 3 Press ESC at anytime to access menu settings See To navigate and access menu settings selections on page 13 PHILIPS Selecon LCD Menu System 13 Installation amp User s Manual PLFRESNEL1 LED Luminaires Menu Structure PHILIPS Selecon LCD Display Menu System MAIN MENU Save as Preset Sub Menu Options Comments Of Users can Save the current settings look to a specific recallable Preset in the Select Preset to Save Option Scratch Pad fixture s memory Edit the levels values for Red Scrolls and sets current user defined Warm White Green Blue White and Intensity color mix to

Download Pdf Manuals

image

Related Search

Related Contents

Audiovox FR-541 Two-Way Radio User Manual  télécharger le document PDF - Act Up  Bertazzoni P60 4 I NE hob  Pawpeds  Samsung SyncMaster  仕 様 書 1. 件 名 液体シンチレーションカウンターの更新 2. 数 量 1式 3  Miller Electric 1000 Welder User Manual  E1 Fallback Switch (4-Way)  Ikelite 6038.94 underwater camera housing  

Copyright © All rights reserved.
Failed to retrieve file