Home
victor 140
Contents
1. VICTOR niGH ACCURACY CLAMP LEAKER VICTOR 140 USER MANUAL SHENZHEN VICTOR HI TECH CO LTD Contents e 1 zs eer eer o 2 Il Electrical SyImDOls see ee e es 3 Ill Technical specifications 4 IV Structure of the Leaker sse 7 V Operating Method 2x suseac eoe to teer tia 8 1 Start up shutdown sss 8 2 Leakage current current 8 3 Peak holdirig i e idee e D rt ed tne ee aces 12 4 Holding cancellation storage lookup and clean up of data 12 VI Function quick check 13 Example Display 13 Battery 15 IX Packing Listi 16 N Warning A Thank you for purchasing the company s VICTOR140 High Accuracy Clamp Leaker for better use of this product please 9 9 Read carefully the user s manual Follow strictly safety rules and notes listed in this manual Under any circumstances please pay special attention to your safety in the course of using this leaker Give heed to label texts and symbols on panel and back plate of this leaker Please don t place and store this leaker in hot and
2. Operators shall strictly observe safety rules otherwise there would be risk of electric shock to cause personal injuries or casualties Dangerous Please don t use it to measure current A higher than 300A otherwise there would be risk of electric shock to cause personal injuries or equipment damages 1 Switch on power of the leaker 2 Confirm to be measured lines dial range switch key RANGE to appropriate range 3 Press down trigger to open clamp head and clamp to be measured conductors Be attention that clamp heads must be fully closed Clamp fire wire zero line together is to measure leakage current of electrical equipment Note 2 lines Clamp grounding line is to measure grounding line leakage current of electrical equipment Note single line Clamp main line is to measure total current of that main line Note single line Attention For your safety when measuring heavy current after confirmed the completion of correct operating test please move the leaker away from measured conductor In locations with difficulty to read out data please use the data holding function If DH symbol displayed please discharge data holding state first and then do the test Reference Diagram Detect safety situation of ope rating equipment Detect leakage of grounding wire ee Det
3. and mining establishments Clamp core of VICTOR140 High Accuracy Clamp Leaker adopts special alloy in addition with utilization of magnetic shielding technology it is basically free from influences of external magnetic field so as to ensure high precision high stability and high reliability of perennial continuous measurement VICTOR140 High Accuracy Clamp Leaker could be used for AC Line current measurement and on line current measurement with voltage lower than AC600V it also have those functions as peaking holding data holding and data storage with convenient use it is an essential tool for electrician safety testing Electrical Signs Extremely dangerous Operators shall strictly observe safety rules otherwise there would be dangers of electric shock to cause personal injuries or casualties Dangerous Operators shall strictly observe safety rules A otherwise there would be dangers of electric shock to cause personal injuries or casualties AN Warning Operators shall strictly observe safety rules otherwise personal injuries or equipment damages might be caused Electrical Signs Continuous form n Double insulation AC DC Ill Technical specifications Measurement of AC leakage current AC Function current and on line AC current DC3V Button type battery LR 44x2 Power SR 44x2 Test Mode Clip on CT integral mode Display Mode
4. 0g with battery safety rules Rating Power about 5mW Working temperature 0 C 40 C below 80 rh and humidity Storage temperature 10 C 60 C below 70 rh and humidity AC2kV rms between core and box Applicable IEC1010 1 IEC1010 2 032 pollution etc 2 CAT III 600V IV Structure of the Leaker 1 Clamp head 2 Trigger 3 Product name model 4 HOLD Key key combination 5 POWER key key combination 6 LCD Displayer 7 Lacing hole 8 Main body 9 RANGE Range switch key 10 Panel film 11 Back plate film 12 Battery cover 64mm Tam gt 8 CLAMP LEAKER Hoama h9 E gt 10 V Operating Method 1 Start up shutdown Press POWER key to start up LCD will begin to display Press the POWER key again the leaker will shut down After starting up for 5 minutes LCD will flicker with notes that the leaker will shut down automatically after flickering for 30s it will shut down formally to reduce battery consumption In case you pressed POWER key when LCD was flickering the leaker will continue to work for 5 minutes If LCD was relatively very dark after starting up it might be caused by low voltage battery in this case please change battery immediately 2 Measurement of leakage current and current High voltage extremely dangerous
5. Four Bits LCD display Dimension Width x Heightx Thickness 64mmx160mmx23mm LCD Dimension 35mmx21 5mm display domain 32mmx15mm Clamp Mouth q40mm Sampling Rate about 2 times s Range 0 00mA 300 0A 50 60Hz Resolution 0 01mA Technical specifications Continuous form Measuring 30mA 300mA 30A 300A second range range manual switch Automatic switch in all ranges 0 00mA 9 99mA 1 2 5dgt Measurement 10 0mA 300 0mA 1 5 5dgt accuracy 0 00A 9 99A 1 2 5dgt below 23 CH C 10 0A 99 9A 1 5 5dgt 70 RH 100 0A 199 9A 2 5dgt 200 0A 300 0A 4 5dgt Line voltage Line test under AC600V Data Storage 60 groups FU symbol flickering means storage is full Peak value capture and holding function press Peak Holding HOLD button continually to show peak value in the course of testing Data Holding Data holding function displayed by DH symbol Overflow Outrange overflow display displayed by OL display symbol Technical specifications Continuous form Automatic shutdown After starting up the leaker for 5 minutes it will shut down automatically to reduce battery consumption Battery voltage When battery voltage reduced to 2 5V 2 7V battery low voltage symbol will filker to remind replacing battery at this time measurement accuracy will decrease Leaker Quality About 12
6. ect leakage hazards of buried cable Grounding wire Reference Diagram Detect current Detect current consumption of consumption of puipment 2 Grounding wire Grounding wire 4 Read out LCD display data In case OL mA symbol was displayed it means that leakage current or current of measured line is beyond the range of 30 300mA and it is of necessary to switch RANGE key to 30 300A and then conduct measurement again in case the leaker displayed OL A symbol on 30 3004 range then it means that current ay d s of measured line is beyond the maximum limit of this leaker case please choose leaker with much higher range limit 3 Peak Holding Pressing IHOLD key continually in the course of measurement More than 3 seconds the leaker will capture current peak values of lines in this period of time release the key it then will return to measuring state 4 Holding cancellation storage lookup and clean up of data 1 Pressing HOLD key for a short time in the course of measurement less than 3 seconds DH symbol will display the leaker holds 2 3 current measuring data and realizes auto ID storage press HOLD key again for a short time the holding will be cancelled with this and the leaker continues its measuring operation in case storing data reached to 60 groups press HOLD key again the FU symbol will display which means sto
7. ght side up direction of the arrow bv IX Packing List Clamp tester 1set Carton 1pc Rope chain 1line Button Battery LR 44x2 or SR 44x2 2 pcs User Manual 1 copy Warranty card Certification 1 copy
8. humid condition locations with moisture condensation and under direct sunlight for a long time In case voltage of battery was low display of LCD would be very dark please replace batteries In case this leaker would not be used for a long time please take out batteries When changing batteries please pay attention to polarity of battery Use disassembly and maintenance of this leaker shall be operated by authorized personnel In case dangers would have with continues use for reason of this leaker please stop to use it and seal it for safekeeping immediately and then send it for disposal of authorized agency Users shall carry out operation based on danger signs A on leaker and manual Users shall carry out safety operation based on instructions listed in this manual e g and danger signs on this manual Please use mA to test leakage current test by clamping grounding line single phase line 2 together I Introduction VICTOR140 High Accuracy Clamp Leaker is specially designed for measurement of AC leakage current by adopting up to date CT technology and digital integration technology it is a product with relatively small size high accuracy and perfect function compared with similar leakers in the world The leaker could be widely applied in those fields as electricity communications meteorology railroad oilfield construction measurement scientific amp research teaching institutes industrial
9. rage data is full press HOLD key to cancel FU flickering and return to measuring mode Press HOLD POWER keys to enter into data access mode and display Group 1 storage data automatically and then press HOLD key again to enter into cyclic reading of stored data press key to exit data access mode POWER After entering into data access mode press key continually More than 3 seconds can clean up all stored data when the leaker displaying YES symbol it means that it has finished cleanup process and then return to measuring state automatically ies VI Function quick check RANGE Key 30 300mA 30 800A Manual range switch POWER Key Short Press Start up shutdown exit HOLD Key Extended Press Data Holding relieving storage HOLD Key Extended Press for more than 3s Peak Holding Measurement mode is as below HOLD Key Extended Press for 3s Data clear Reading mode is as below HOLD Key POWER Key Data access reading HOLD key VII Example Display 1 Measured leakage current is 0 25mA 2 Measured current is 199 0A Ol 4l ma Ll AC d 3 Measured leakage current 4 Battery is undercharge please higher than 300mA replace battery immediately Can not ensure the acc
10. uracy of 6 30mA at this time xn oL UL En Ll LI 5 Measured current is 5 00mA 6 Storage data is full with 60 Hold measured data groups FULL Automatically stored as Must be removed Group 03 data before they can re store 4 251 4 L L rickeri OU 7 Get access to stored 8 upon full completion of clearing Group 03 data of data it will indicate YES urs 3 J Lu L m wot VIII Battery replacement Warning It is dangerous to carry out test under the case that battery cover plate was not on its position Please pay attention to polarity of battery to avoid N damaging the leaker could In case battery was undercharge please replace it immediately otherwise accuracy of measurement not be guaranteed 1 In case battery voltage reduced to 2 5V 2 7V the leaker would display symbol replaced 2 Press POWER it means the battery is undercharge and need to be key to shut down the leaker before opening the battery cover please confirm the leaker is in off position and then replace with qualified new battery special attention shall be paid to polarity of battery at last cover battery cover plate As shown in Figure below 3 Uncover cover plate in With positive pole of Button up cover in the the direction of the arrow battery ri