1. Figure 2 5 Connecting a SierraFC M8 4 and a Summit T3 16 10 CrossSync User Manual Host PC Connections Using Various Configurations LeCroy Corporation Connecting Three Analyzers with Built in Micro D Sync Ports The following example shows how to daisy chain 3 analyzers with built in Micro D sync ports To do so perform the following steps This configuration requires the optional Micro D to DB 9 sync cable ACO30XXA X 1 Make sure to stop any recordings in progress Note You may plug unplug the sync cable while the analyzer unit is powered on 2 Connect the analyzers using the built in on board Sync Data ports 3 Connect the Micro D end of the sync cable to the Sync Data port of the first analyzer 4 Connect the male end of the DB 9 cable to the female end of the second DB 9 cable 5 Connect the Micro D end of the sync cable to the Sync Data port of the second analyzer 6 Connect the male end of the DB 9 cable to the female end of the third DB 9 cable 7 Connect the Micro D end of the sync cable to the Sync Data port of the third analyzer ROSE ROSE ROIS Cay Yk O T Re ip lip Uk A Figure 2 6 Connecting Three Analyzers CrossSync User Manual 11 LeCroy Corporation Host PC Connections Using Various Configurations Connecting Three Analyzers with DB 9 Sync Ports The following example shows how to daisy chain 3 analyzers with DB 9 sync ports To do so perform the
2. Micro D to DB 9 Sync cable ACO30XXA X CrossSync User Manual 5 LeCroy Corporation Host PC Connections Using Various Configurations Host PC Connections Using Various Configurations An analyzer connected in a CrossSync configuration may be connected to the Host PC using any host interface connection supported by the analyzer The CrossSync control panel running on the Host PC can then be used to control all synchronized analyzers for time synchronized recording sessions CrossSync Cabling for Various Configurations Connecting a Sierra M6 1 SAS SATA Analyzer and a Advisor T3 USB Analyzer via the Micro D Sync Cable The devices are connected using their built in Sync ports Perform the following steps 1 Make sure to stop any recordings in progress Note You may plug unplug the sync cable while the analyzer unit is powered on 2 Connect the Advisor T3 to the Sierra M6 1 using the built in Sync ports via the Micro D Sync cable Figure 2 1 Daisy chained Sierra M6 1 and Advisor T3 Analyzers 6 CrossSync User Manual Host PC Connections Using Various Configurations LeCroy Corporation Connecting Two Voyager M3i USB Analyzers via the CATC Sync Expansion Card ACC EXP 002 X Two Voyager M3i USB analyzers are connected using their CATC Sync ports which require an optional expansion board ACC EXP 002 X Note Refer to relevant protocol analyzer user manual for instructions on how to install the
3. LeCroy CrossSync User Manual For LeCroy Protocol Analyzers CrossSync Control Panel Version 2 21 Document Version 1 12 August 2011 LeCroy Protocol Solutions Group Copyright 2011 LeCroy Protocol Solutions Group All rights reserved Trademarks and Servicemarks LeCroy LeCroy Protocol Solutions Group CATC SASSuite SATASuite SASTracer SATracer SASTrainer SATrainer SASTracker are trademarks of LeCroy Microsoft Windows Windows 2000 and Windows XP are registered trademarks of Microsoft Inc Intel and Pentium are registered trademarks of Intel Corporation All other trademarks and registered trademarks are property of their respective owners THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT NOTICE ALL INFORMATION EXAMPLES AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT ARE REPRESENTED WITHOUT WARRANTY OF ANY KIND EXPRESS OR IMPLIED USERS ARE FULLY RESPONSIBLE FOR THEIR APPLICATION OF ANY PRODUCTS THE SOFTWARE LICENSE AND LIMITED WARRANTY FOR THE ACCOMPANYING PRODUCT ARE SET FORTH IN INFORMATION THAT SHIPPED WITH THE PRODUCT AND ARE INCORPORATED HEREIN BY THIS REFERENCE IF YOU ARE UNABLE TO LOCATE THE SOFTWARE LICENSE OR LIMITED WARRANTY CONTACT LeCroy FOR A COPY Copyright 2011 LeCroy Corporation All rights reserved This document may be printed and reproduced without additional permission but all copies should contain this
4. Search reporting and decoding all operate normally The CrossSync option supports a wide combination of LeCroy s flagship analyzers including PCI Express Gen 1 Gen 2 and Gen 3 USB 2 0 and 3 0 Serial ATA SATA 1 5 3 and 6Gbps Serial Attached SCSI SAS 3 and 6Gbps Fibre Channel 1 2 4 and 8 Gbps systems and DDR3 CrossSync User Manual 1 LeCroy Corporation CrossSync Capable Products CrossSync Capable Products The following products support CrossSync operation TABLE 1 1 LeCroy Protocol Suites and Products Required Software Product USB Protocol Suite 4 20 and later USB Voyager Mai USB Advisor T3 SAS SATA Protocol Suite 4 00 and later SAS SATA Sierra M6 4 SAS SATA Sierra M6 2 SAS SATA Sierra M6 1 FC Protocol Suite 3 25 and later SierraFC M8 4 PETracer 6 50 and later PCle Summit T28 PCle Summit 13 16 PCle Summit T3 8 DDR Protocol Suite 1 01 Kibra 380 DDR3 IOTA Software Suite 1 00 N A LeCroy will add support for more protocol analysis products in the future Overview of the CrossSync Hardware The CrossSync capability requires that analyzers are connected using their Sync ports CrossSync can be used with the built in Sync port included on every Advisor T3 and Sierra M6 1 analyzer For owners of LeCroy s Sierra Summit T3 and Voyager M3i based analyzers the CATC Sync port requires the optional expansion board ACC EXP 002 X There may be additional configurations added in the future for platforms that can
5. if more than one application is open Custom Layout Displays a custom application layout Multimonitor Displays the application windows across dual monitors Save Current layout Saves the current application layout display The Help icon opens the Help and About dialog This is a dual mode button clicking on the down arrow displays the following menu QI QI Help About The Close icon closes the application and all protocol applications CrossSync User Manual CrossSync Control Panel LeCroy Corporation Session Configuration The Device List allows for easy discovery and selection of analyzers for synchronization see the table below Perform the following steps to configure a session 1 Open the Devices dialog and select the devices you want to use by checking the corresponding boxes in the Set column of the list LeLroy CrossSync Devices x Sel Device Location P1 Fa Pa P4 Status 1 Simulation Device i Local machine Ready 2 Voyager 5 501 cs i Local machine gt Ready 3 Adveor T3 SN 50 p Local machine cC Ready Refresh Close Figure 3 10 Devices Dialog 2 For each selected device click the Record Setting icon LL to invoke the settings dialog for that device in its respective protocol application See the protocol application s User Manual for details on how to configure the settings 3 Click Close to close the Devices dialog CrossSync User Manual 23 LeC
6. Synchronized Time Stamps 26 CrossSync User Manual How to Contact LeCroy Type of Service of Service Contact S Call Len ail technical support US and Canada 1 Ga 909 7112 Worldwide 1 408 653 1260 Write a letter LeCroy Protocol Solutions Group Customer Support 3385 Scott Blvd Santa Clara CA 95054 3115 USA Visit LeCroy s web site http www lecroy com CrossSync User Manual 27 LeCroy Corporation 28 CrossSync User Manual A address 27 Application Overview 17 Applications Layout icon 22 Applications Tab 16 B Break Sync Trace Files 21 Break Sync Trace Files icon 21 C CATC Technical Support 27 Close icon 22 Connecting Advisor T3 and a Sierra M6 2 8 Advisor T3 a Voyager M31 and a Summit 13 16 9 Kibra 380 DDR3 Protocol Analyzer for CrossSync with the IOTA Software Suite 13 Sierra M6 1 SAS SATA Analyzer and a Advisor T3 USB Analyzer via the Micro D Sync Cable 6 SierraFC M8 4 and a Summit T3 16 via the CATC Sync Expansion Card 10 Three Analyzers with Built in Micro D Sync Ports 11 Three Analyzers with DB 9 Sync Ports 12 Two Voyager M3i USB Analyzers via the CATC Sync Expansion Card 7 contact 27 CrossSync Cabling for Various Configurations 6 CrossSync Control Panel 16 CrossSync Hardware Reguirements 3 CrossSync Multi Protocol Analysis option 1 CrossSync Software Overview 15 CrossSync Synchronized Time Stamps 25 CrossSync Capable Products 2 D Devices 2
7. expansion board To do so perform the following steps 1 Make sure to stop any recordings in progress Note You may plug unplug the sync cable while the analyzer unit is powered on 2 Connect the female end of the sync cable to the SYNC OUT port of the first analyzer 3 Connect the male end of the sync cable to the SYNC IN port of the second analyzer N Figure 2 2 Two Voyager M3i Analyzers Daisy chained CrossSync User Manual LeCroy Corporation Host PC Connections Using Various Configurations Connecting an Advisor T3 and a Sierra M6 2 This configuration requires the optional Micro D to DB 9 sync cable ACO30XXA X To do so perform the following steps 1 Make sure to stop any recordings in progress Note You may plug unplug the sync cable while the analyzer unit is powered on 2 Connect the Micro D end of the sync cable to the Sync Data port of the Advisor T3 3 Connect the male end of the DB 9 cable to the SYNC IN port of the Sierra M6 2 Alternatively connect the female end of the DB 9 cable to the SYNC OUT port of the Sierra M6 2 Figure 2 3 Connecting an Advisor T3 and a Sierra M6 2 Analyzers 8 CrossSync User Manual Host PC Connections Using Various Configurations LeCroy Corporation Connecting an Advisor T3 a Voyager M3i and a Summit T3 16 This configuration reguires the optional Micro D to DB 9 sync cable ACO30XXA X This example shows connecting an Adviso
8. not hardware synced with other analyzers If other analyzers will be the trigger source then move IOTA to the top of the list If IOTA will be the trigger source then move IOTA to the bottom of the list You can move IOTA up and down as follows 1 Select IOTA Protocol Suite in the Seguence of Run pane 2 Click Move Up or Move Down as required LeCroy CrossSync Settings SM x Run Sequence Trace File Time Tune General l FC Protocol Suite ai 545 Protocol Suite E OOA Protocol Suite 4 OTA Protocol Suite 5 SATA Protocol Suite y y Move Up Move Down DK Cancel Figure 3 3 Run Sequence Tab CrossSync User Manual 17 18 LeCroy Corporation CrossSync Control Panel Trace File Tab The Trace File tab displays the Output Trace File s Path Click the Browse button to select a new path Check the box if you want to save each run in a new folder New folders are assigned names based on the recording session start date and time LeCroy Lrnss5ync Settings 4 aa Applications i Run Sequence Trace File Time Tune General Output Trace Files Path Program FilestCommon FilesiLecros shared Traces idd Mew Folder for Each Run OK Cancel Figure 3 4 Trace File Tab Note The default trace file location on Windows XP is C Program Files Common Files LeCroy Shared Traces The default trace file location on Windows Vista and Windows 7 is C Users Publi
9. support the CATC Sync framework Overview of the CrossSync Software The CrossSync control panel requires updated analyzer software that supports the new CrossSync framework The CrossSync control panel does not have a separate installer instead it is embedded in the Protocol Suite installers The solution includes a lightweight software control panel that starts and stops recording across daisy chained analyzers Users can sync or un sync traces on the fly The Time Tune feature provides an interactive slider for adjusting the off set between displays This makes it easy to see latency across busses Note If the system prompts you that it cannot write a trace file to disk 1 Make sure that the trace file destination folder has write create permissions For example the target directory might be the network file system which typically does not have write create permissions 2 Make sure that the Windows or other Firewall Settings for all LeCroy applications are set to Public 2 CrossSync User Manual Hardware Setup CrossSync Hardware Requirements The CrossSync capability requires that analyzers are connected using their Sync ports CrossSync can be used with the built in Sync port included on every Advisor T3 and Sierra M6 1 analyzer For owners of LeCroy s Sierra Summit T3 and Voyager M3i based analyzers the CATC Sync port requires the optional expansion board ACC EXP 002 X Up to eight analyzers may be connected in a singl
10. 1 Devices Dialog 23 Devices icon 21 Dockable Bar 20 CrossSync User Manual Index E e mail 27 Email CATC Support 27 F fax number 27 G General Tab 19 H Hardware Setu 3 Help icon 22 Host PC Connections Using Various Configurations 6 L Launching the Application 16 LeCroy Analyzers and Cables Reguired for CrossSync 4 M Main Buttons 21 O Open File 21 Open File icon 21 Overview of the CrossSync Hardware 2 Overview of the CrossSync Software 2 R Record 21 Record icon 21 Run Seguence Tab 17 29 LeCroy Corporation Index S Select Application 21 Select Application icon 21 Session Configuration 23 Settings 21 Settings icon 21 Support 27 System Tray 20 System Tray Icon 20 System Tray Icon Functions 20 T Technical Support 27 telephone number 27 Time Tune Tab 19 Topology View 24 Trace File Tab 18 W web site 27 Website CATC 27 30 CrossSync User Manual
11. 50467 04 Transaction S ADDR me Time mes 9 S aen 75 240 us 0 53391 Logical Block Addr Ox005E0047 533 701 280 ms Data 2045 Bytes 00 01 0203 0405 06 07 08 09 DA 0B gt gt 7 800 us Data RCE Passed Time Time Stamp Transport Y STP Frame Type 4096 4096 bytes es res 0x0 76 696 us 0 533 988 192 360 ms 4 0x34 Register Device to Host PM Part H I H Status H Error H 7 Transaction S z Sector Number H Cyl Low H Cyl High H Dev Head H 16 Q i ADDR Logical Block Addr Sector Num exp H Cyl Low exp H Cyl High exp H 1 63344128 SCSI CDB 10 Ox00150ABF Data EON Passed Time Time Stamp Sector court Ap Ui RD 4608 bytes res 0x0 105 104 ps 0 536 383 288 00 536 us 0 536 48 Time 2 318 ms 0 534 06 me fers gt 3 533 044 613 ms das Input H mj Normal Output H 4l Figure 3 12 Synchronized Time Stamps Using the CrossSync Control Panel you can use triggering to find the same packet traveling across both busses identifying the point where a specific bus event moves over a bridge Either analyzer can be setup as the trigger master When the trigger event is detected the capture stops and the display shows the exact point where the event occurred Separate trigger events that operate independently for each side of the bridge can also be defined CrossSync User Manual 25 LeCroy Corporation CrossSync
12. c Documents LeCroy CrossSync Traces CrossSync User Manual CrossSync Control Panel LeCroy Corporation Time Tune Tab The Time Tune tab provides an interactive slider for adjusting the offset between displays The Source is the time reference point for the Target The Target time sync is offset by Delta relative to the Source The Time Tune tab displays the following Q Source Double click on the icon to switch the Source Target Displays the target Delta Enter a value or slide the tuner to select the offset Time Type Select a value in seconds milliseconds microseconds or nanosec onds from the drop down list DUOL LeCroy Cross y nc Settings E EE xj J y Applications I Run Sequence Trace File TimeTune General gt Source Target Delta Time Type SATA 4f Gn ED ir G ng hh G ns J O ns OK Cancel Figure 3 5 Time Tune Tab General Tab The General tab allows you set the general settings Select the check box to show the information balloon popups in the Windows System Notification Tray LeCroy CrossSy nc Settings i ES x 4 Applications Run Sequence Trace File Time Tune General E General Settings OK Cancel Figure 3 6 General Tab CrossSync User Manual 19 LeCroy Corporation CrossSync Control Panel Dockable Bar By default the application will dock to the top of the screen Right click in the bar to in
13. copyright notice LeCroy Corporation 3385 Scott Blvd Santa Clara CA 95054 TEL 800 909 7112 USA and Canada TEL 408 653 1260 worldwide CrossSync User Manual il Chapter 1 MEO CIC TO Woes ee i GR GN on a D nc 1 CrossSync Multi Protocol Analysis Option c cccccccseeeseeeeeeeeeneceeeeeneseeeeeeeeeeseseneeenesseeesnenees 1 Crossoync CGapable ProduUclS ee Gu a alec ace ese see eae GY One 2 Overview of the CrossSync Hardware ccccccccsecsescseeeeeeseeeecneeceseeeneseneeeeeseeeseenseneseneseeesonaes 2 Overview of the CrossSync Software cixisisscsdecictes hernie causant eee eee 2 Chapter 2 Hardware S5etUp iu ae Y GYR Ma FN DOE 3 Crosssync Hardware ReguirementS iei Liu FU i enu GaL Ryn inn demon returned GAWR O tel Un g ete fous 3 Host PC Connections Using Various Configurations sise 6 CrossSync Cabling for Various Configurations u YY YYYL LLALL AA SYALL ees senses YL sees NWY YH Yn nnnnnu 6 Connecting a Sierra M6 1 SAS SATA Analyzer and a Advisor T3 USB Analyzer Via the MICFO D SYNC Cable ee NR dn a a dd te rene CARNAU UUN 6 Connecting Two Voyager M3i USB Analyzers via the CATC Sync Expansion Card ACC EXP DD2X a ete ea tone cote 7 Connecting an Advisor T3 and a Sierra M6 2 ri rrnrrnnrnnnnneneneennnnns 8 Connecting an Advisor T3 a Voyager M3i and a Summit 13 16 Leeeeeeeneeneeeeeneeeneeneen ee 9 Connecting a SierraFC M8 4 and a Summit T3 16 via the CATC S
14. displays the following menu Q Zip Most Recent Traces Q Open Traces Folder in Windows Explorer The Break Sync Trace Files icon toggles the view synchronization between traces The Select Application icon allows you to select the application suite you would like to run This is a dual mode button clicking on the down arrow displays the following menu Q FC Protocol Suite PETracer SAS Protocol Suite SATA Protocol Suite USB Protocol Suite DDR Protocol Suite IOTA Protocol Suite DOOUOCDOD The Devices icon opens the Devices dialog This is a dual mode button clicking on the down arrow displays the following menu O The selected Device Name and Serial Number O Refresh The Settings icon opens the LeCroy CrossSync Settings dialog There are four tabs Applications Trace File Time Tune and General where the application settings can be selected The Record icon starts a synchronized session 21 LeCroy Corporation CrossSync Control Panel 22 Stop Applications Layout LS Help The Stop icon stops a session Clicking the Applications Layout icon re applies the last selected layout This is a dual mode button clicking on the down arrow displays the following menu Horizontal Displays the application windows horizontally Cascading windows are displayed if more than one application is open Vertical Displays the application windows vertically Windows are displayed cascading vertically
15. e chain The AdvisorT3 and Sierra M6 1 use the built in Micro D Sync port and only reguire the Micro D Sync cable ACO31XXA X Systems with an expansion slot such as Sierra M6 4 Sierra M6 2 SierraFC M8 4 Voyager M3i and Summit T3 16 require the CATC Sync Expansion Card and DB 9 Sync cable ACC EXP 002 X The Kibra 380 DDR3 and PCle Summit T28 use built in DB 9 sync ports and reguire a DB 9 sync cable ACC EXP 002 X Analyzers daisy chained via sync cables will automatically synchronize time stamps trigger recording start and recording stop CrossSync User Manual 3 LeCroy Corporation CrossSync Hardware Requirements TABLE 2 2 LeCroy Analyzers and Cables Required for CrossSync Option Analyzers and Cables Analyzers with built in Micro D Sync Ports requiring Micro D Sync cable ACO31XXA X Analyzers requiring CATC Sync Expansion Cards and DB 9 Sync cable ACC EXP 002 X Analyzers with built in DB 9 Sync ports requiring DB 9 sync cable ACC EXP 002 X Required Cables DB 9 Sync cable ACC EXP 002 X Product USB Advisor T3 SAS SATA Sierra M6 1 SierraFC M8 4 SAS SATA Sierra M6 4 SAS SATA Sierra M6 2 PCle Summit T3 16 PCle Summit T3 8 USB Voyager M3 Kibra 380 DDR3 PCle Summit T28 CrossSync User Manual CrossSync Hardware Requirements LeCroy Corporation TABLE 2 2 LeCroy Analyzers and Cables Required for CrossSync Option Analyzers and Cables Product Micro D Sync cable ACO31XXA X
16. following steps This configuration requires two DB 9 sync cable 1 Make sure to stop any recordings in progress Note You may plug unplug the sync cable while the analyzer unit is powered on 2 Connect the female end of the first sync cable to the SYNC OUT port of the first analyzer 3 Connect the male end of the first sync cable to the SYNC IN port of the second analyzer 4 Connect the female end of the second sync cable to the SYNC OUT port of the second analyzer 5 Connect the male end of the second sync cable to the SYNC IN port of the third analyzer 12 CrossSync User Manual Host PC Connections Using Various Configurations LeCroy Corporation Connecting Kibra 380 DDR3 Protocol Analyzer for CrossSync with the IOTA Software Suite Kibra 380 usage with IOTA reguires the Ref Clk In Trigger In and Trigger Out SMAs see Figure 2 7 LeCroy Corporation DDR3Frotocol Analyzer Model 800 0293 00 AO DC IN ca In Sync Out 5A oao of o ue Figure 2 7 Kibra Rear Panel Connections See the LeCroy IOTA Software Suite User Manual for details CrossSync User Manual 13 LeCroy Corporation Host PC Connections Using Various Configurations 14 CrossSync User Manual Software CrossSync Software Overview The CrossSync control panel does not have a separate installer and instead is embedded in the Protocol Suite installers The solution includes a lightweight software control panel that starts a
17. lems at the system level CrossSync User Manual 15 LeCroy Corporation CrossSync Control Panel CrossSync Control Panel Launching the Application Click Start gt Programs gt LeCroy gt CrossSync gt CrossSync Control Panel to launch the application On first launching the CrossSync Control Panel the LeCroy CrossSync Settings dialog is displayed The Settings dialog displays all the available Protocol Applications Suites Select the protocol applications you want to use and click OK The selected applications are launched automatically i LeCroy Cross5ync Settings y Applications FC Protocol Suite PETracer SAS Protocol Suite SATA Protocol Suite USE Protocol Suite Figure 3 2 LeCroy CrossSync Settings Dialog Applications Tab The Applications tab displays all the available applications On subsequent sessions your preferred applications are automatically launched You may change the applications at any time from the Settings dialog 16 CrossSync User Manual CrossSync Control Panel LeCroy Corporation Application Overview The following section introduces you to the application Once the application launches four tabs are displayed They are explained below Note The Applications tab is explained in the previous section Run Sequence Tab The Run Sequence tab is only used when using the LeCroy IOTA Software Suite It displays all the applications that are running The IOTA start capture is
18. nd stops recording across daisy chained analyzers Users can sync or un sync traces on the fly The Time Tune feature provides a real time slider for adjusting the off set between displays This makes it easy to see latency across busses LeCroy CrossSync Settings a Applications Trace File TimeTune General Source Target Delta Time Type Si SATA Si am Start and Stop Synchronized Recordings Use the Time Tune slider to adjust the off set between displays is ES hm w O Record Eu Open previously captured traces which remain synchronized Easily Discover and Sync Analyzers attached to the system LeCroy CrossSync Devices Devices List Topology View Un sync traces to scroll each window separately Sel Device Location P1 P2 P3 P4 Status Simulation Device E ig Local machine Ready vd Local machine o Ready fo Local machine o Ready v 2 M Voyager SN 501 31 F Advisor T3 SN 507 As is Figure 3 1 CrossSync Control Panel The CrossSync control panel requires the analyzers to be connected using their Sync ports This Sync port is built in to every Advisor T3 and Sierra M6 1 analyzer For owners of LeCroy s Summit T3 Voyager M3i and Sierra based analyzers the Sync port is available as an optional expansion board ACC EXP 002 X that can be installed by users in just a few minutes This allows developers to leverage analyzers already in the lab to help resolve multi protocol prob
19. r T3 a Voyager M3i USB and a PCle Summit T3 16 analyzer To do so perform the following steps 1 Make sure to stop any recordings in progress Note You may plug unplug the sync cable while the analyzer unit is powered on 2 Connect the Micro D end of the sync cable to the Sync Data port of the Advisor T3 3 Connect the male end of the DB 9 cable to the SYNC IN port of the Voyager Mai 4 Connect the female end of the DB 9 cable to the SYNC OUT port of the Summit T3 16 Figure 2 4 Daisy chaining an Advisor T3 a Voyager M3i and a Summit T3 16 CrossSync User Manual 9 LeCroy Corporation Host PC Connections Using Various Configurations Connecting a SierraFC M8 4 and a Summit T3 16 via the CATC Sync Expansion Card ACC EXP 002 X A SierraFC M8 4 and a PCle Summit T3 16 are connected using their CATC Sync ports which reguire an optional expansion card ACC EXP 002 X Note Refer to relevant protocol analyzer user manual for instructions on how to install the expansion board To do so perform the following steps 1 Make sure to stop any recordings in progress Note You may plug unplug the sync cable while the analyzer unit is powered on 2 Connect the female end of the sync cable to the SYNC OUT port of the SierraFC M8 4 3 Connect the male end of the sync cable to the SYNC IN port of the PCle Summit T3 16
20. roy Corporation CrossSync Control Panel TABLE 3 4 CrossSync Devices Device List Tab Column Descriptions Columns Description Item number Numeric list of device Sel Device Selection checkbox Check the box to include the device in the recording session Uncheck the box to exclude the device from the recording session Device Device Name and Serial Number Protocol Suite Icon of the Protocol Suite of the device being used is displayed Record Setting Click to invoke the settings dialog for that device in its respective protocol application Location Location of the device local or on the network Ports Identifies ports P1 P2 P3 and P4 A icon indicates an Analyzer is connected A icon indicates the port is not being used Status Indicates the status of the device They are Ready Device is ready to begin a session Working Device is currently in a session Ready to connect Device is on the network and available for connection Locked by lt user gt Device is on the network but in use by lt user gt Not working properly Device may require a BE FW update Topology View 24 Once the analyzers have been set the Topology View provides a visual layout of all the devices attached to the CrossSync control panel LeCroy CrossSync Devices Devices List Topology View I 3 Summit T3 16 SN 62393 4 Voyager M3i SN 62394 Location Local machine Location 192 168 12 2
21. s a cesse tueL s 23 TOPDOIOQV VIGW cau Gn Ga Ea OA y CF etes aY tite ee 24 CrossSync Synchronized Time Stambps 9 9 YYY YY YL LLALL SAY ALL HA Y ALL ALL HL es senses nee 25 Appendix A How to Contact LeCroy run ny YW YY Y WL YL nu nynnnnnnnonn 27 OO Y YH a ne a ns nee Ve 29 iv CrossSync User Manual Introduction The LeCroy CrossSync control panel provides synchronization for complete end to end visibility into multi protocol systems This document discusses the overview hardware setup and software for the CrossSync Multi Protocol analysis system CrossSync Multi Protocol Analysis option CrossSync is LeCroy s analyzer synchronization solution that enables time aligned display of protocol traffic from multiple daisy chained analyzers showing packet traffic from multiple high speed serial busses A lightweight software control panel allows users to select analyzers for synchronization and manage the recording process Captured traffic is displayed using the latest analyzer software in separate windows with all the protocol specific search and reporting features Captured packets are displayed in separate windows that share a common time scale Navigating the traffic in either direction will scroll to the same timestamp in a synchronized window When using the CrossSync option users can access the full complement of analysis capabilities available within the individual LeCroy software
22. um mmmmm an Figure 3 11 Topology View CrossSync User Manual CrossSync Synchronized Time Stamps LeCroy Corporation CrossSync Synchronized Time Stamps Synchronized time stamps make it easy to find the precise point where events from one bus cross over an adjacent protocol bridge as shown below Clicking on a packet in one view will cause the other view to jump to the corresponding time point taking into account the Time Tune settings LeCroy SAS Protocol Suite Sample scs OX F LeCroy USB Protocol Suite C Program Files LeCroy USB data5_ 000 File Edit View Configuration Project Setup Filtering Report Tools Window Help m xil EE File Setup Record Generate Report Search View Window aie PRES Gl amp ncu Banus amp RH pele B W dE jm Mode Record m S a PROF Oo RRWD sc Liu EB n mw fg O TEI IE sc KA gt i i Ber Bar i BR a TE KK ERIR ER amp HK R TO E Te Fee Bon n T1 12 T2 I3 T3 14 T4 ADDR Logic al Block Addr 1 0x83344128 MH 0x00150467 Link A so Data mu Passed Time Time Stamp 2048 2048 bytes res 0x0 193 368 ps 0 533 626 664 FIS Type ATA Command 0x35 Write DMA Ext ADDR Logical Block Addr 1 0x83344128 0x005F3397 Data ECS Passed Time Time Stamp 4096 4096 bytes res Ox0 100 920 ps D 533 812 032 SecCount H Link Data H 0000001
23. voke a context menu that allows to change the docking orientation or to make it a floating window You can select AutoHide to hide the tool bar when you move the mouse cursor to the top of the screen the tool bar will re appear a hm L e Record L Dock Top C Dock Bottom Dock Right L Dock Left Floating SutoHide Figure 3 7 Dockable Bar System Tray The application automatically installs a LeCroy CrossSync Control Panel System Tray icon for easy access Figure 3 8 System Tray Icon Right click on the System Tray icon for quick access to the control panel functions The options on the menu will be displayed according to the applications being used Open File Zip Most Recerk Traces Open Traces Folder in Windows Explcrer Break Syrc Trace Fies 4 Dev ces k Select Application Settings Start Session Stop Session Appicatio s Layout k Hele Positioning k Exit Figure 3 9 System Tray Icon Functions 20 CrossSync User Manual CrossSync Control Panel Main Buttons LeCroy Corporation The main icons are explained in the following table TABLE 3 3 Main Icons and Descriptions Icons Open File Break Sync Trace Files Select Application h Devices Record CrossSync User Manual Descriptions and Submenus The Open File icon opens a set of synchronized traces from a previous session This is a dual mode button clicking on the down arrow
24. ync Expansion Card ACC EXP 0D02 X i ee duu O Od ee GOD O CG Que detente Stern a rene iene penn R O 10 Connecting Three Analyzers with Built in Micro D Sync Ports ses 11 Connecting Three Analyzers with DB 9 Sync Ports in YHA LLSAA SHALL Y ALNH ANNA Y YL nn eann en ee 12 Connecting Kibra 380 DDR3 Protocol Analyzer for CrossSync with the IOTA Software Suite 13 iini MW MH Y O HR HWN ER 15 CrossSync Software Overview 999 99 999 999L LY LLALL NL ALHHEL HALL ALLN ALLA YNA ALRR RL HYD RL YNE nno 15 Crossoync Control Panel nee teed doce aige Uy yu nee tn cena cette 16 LAUNGHING INEsADDINGALION iie i RR aY O Ran ER dr mr ana teen ee etui ere 16 ADDHCATIONS LAD EFF O Y On E REF HEATH RYN FFF HUN RA IN RF RR OR 16 PADDINC ATION OVerV IeW ic uu E dU NR GN GRY a on eu canes 17 RUn gt eduence ab su i nan SEA pain GEAR ts ei serge tonne NU lasse a i 17 CrossSync User Manual iil LeCroy Corporation Contents Wace FING Faisean aa Y OI sense sense cena E desde eau FYNN TY 18 Time Tune FAP Ste AW TE REN y RF PE A ER ER A RH HA Y NN TYN 19 General fab cn eR aa dyn ee re a nn O ain O nd dn LO 19 DOCK ADIC let MH RF RA HR RF HT YTI I I FI TR RAT FFF GRED A A 20 Systen Tray ui aei ete cn ane ee YN ORA E NAY NUIG ian NN aU 20 Maim BUHONS ee ay Dy aa GA AG da O RA NW NCF 21 SESSION CONTIQUrATION isie iii sans nounou een GON NO Gyd ad gi UU DDR ny CY dded GR cela YdGn taser e