Home

ARLEY STEAM SHOWER ENCLOSURE

image

Contents

1. Arley Steam Shower Enclosure Installation and User Manual 17 CONTROL PANEL Radio Settings Selecting and saving preset radio stations e Turn the radio on e Push the Radio Settings button twice to display the preset numbers 1 8 Image 14 e Scan to the desired station and hold the Radio Settings button until the appropriate preset number is displayed Finding a preset station e Turn the radio on e Push the Radio Settings button to scan through the preset stations STEAM GENERATOR CLEANING To clean the steam generator remove the cover from the cleaning liquid inlet Input 1L of mild detergent Turn the steam function on to fill the generator with water Before steam is released turn the steam function off Do not shut off the control system the system will drain the dirty water automatically after 60 minutes Repeat these steps to clean the steam generator every 3 months ei SIGNATURE HARDWARE Image 14 La Se a p d y CY O Kit Pe Ur Ch f A T customer service 1 866 855 2284 signaturehardware com Arley Steam Shower Enclosure Installation and User Manual 18 TROUBLESHOOTING If the touch panel is not functioning properly e Check the connection from the control panel to the power box If the control panel and power box are properly connected and problems persist it may be necessary to replace the panel or box If the steam function is ON but no steam is being released into th
2. Hi e o ST4X50 flat head Leen flat head x tapping screw tapping screw Be fe ST4X50 flat head ST4X40 flat head tapping screw tapping screw bw 4 Attach the technical panel to the right wall panel and secure with the assembly screws provided ST4X16 round head tapping screw M4X25 flat head machine screw M4 eee M4 nut D customer service 1 866 855 2284 ei SIGNATURE HARDWARE signaturehardware com Arley Steam Shower Enclosure Installation and User Manual 4 5 To install the fixed door panel place one side of the door panel into the shower frame and the other onto the track Attach brackets to both sides of the door panel with assembly screws ST4X20 flat head tapping screw Q SCHT lt 6 Repeat the previous steps to install the remaining door panel ST4X20 flat head tapping screw customer service 1 866 855 2284 signaturehardware com ei SIGNATURE HARDWARE Arley Steam Shower Enclosure Installation and User Manual 5 7 Attach the top cover to the shower frame with the assembly hardware M4 nut e j M4 gasket e e M6 nut front track 4 A M6 gasket ST4X12 mushroom head pa as tapping screw lt i D i acrylic roof pal TA Acrylic Cover pe A FSS SN A g back panels corner on technical 8 Axis panel M4X25 flat head machine screw M6X25 hexagon machine screw front track ST4X25 flat head machine screw be d Ai
3. The unit must be connected to a supply circuit that is protected by a ground fault circuit interrupter GFCI The ap propriate GFCI should be provided by the installer and should be tested on a routine basis e To test the GFCI push the Test button The GFCI should power off Push the Reset button to restore the power If the GFCI fails to operate in this matter it is defective e Ifthe GFCI fails to provide power to the shower enclosure and a ground current is flowing the user could potential ly incur an electric shock Do not use the shower enclosure and repairs performed by a qualified electrician before using e Agreen colored terminal or wire connector marked G GR or Ground is provided within the front column To reduce the risk of electric shock connect this terminal or connector to the grounding terminal of your electric service or supply panel with a connector equivalent in size to the circuit of the conductors supplying this equipment To reduce the risk of injury e The wet surfaces of steam enclosures may be slippery Use care when entering or leaving e The steam head is hot Do not touch the steam head and avoid the steam near the steam head e Prolonged use of the steam system can raise internal body temperature and impair your body s ability to regulate temperature hyperthermia Limit steam use to 10 15 minutes at a time until you are certain of your body s reaction e Excessive temperatures have a
4. Yi wooden roof a MI 4 CV wan jo y 7B Wooden Cover Ly back panels OG 2 E ST4 16 mushroom head machine screw corner on amp Axis technical panel 4 ST4X16 mushroom head machine screw customer service 1 866 855 2284 ei SIGNATURE HARDWARE signaturehardware com Arley Steam Shower Enclosure Installation and User Manual 6 8 Connect the flexible water feed tubes and electrical wiring to the corresponding outlets 8 1 exhaust fan 8 2 chromatherapy lamp 8 3 speaker ceiling shower pipe 9 Install the shower door gasket hinge back cover movable glass door gasket hinge main body customer service 1 866 855 2284 signaturehardware com ei SIGNATURE HARDWARE Arley Steam Shower Enclosure Installation and User Manual 7 10 Attach the hand shower slide bar M4X25 M4 25 screw M4 black O ring technical panel M4 gasket sliding bar 11 Attach the door handle CLL Ma nut small copper meson M4 25 screw small decorative cap E hanno holder customer service 1 866 855 2284 signaturehardware com ei SIGNATURE HARDWARE Arley Steam Shower Enclosure Installation and User Manual 8 12 Attach the door handle 13 Install the seal strips according to the drawing specifications to prevent leakage 309B seal magnetic stripe on the movable door movahle glass door 309D s
5. ARLEY STEAM SHOWER ENCLOSURE INSTALLATION AND USER MANUAL CONTENTS Steam Shower Enclosure lnstallaton eee 2 Technical JIntormaton 2 Plumbing REQUIFEMENIMS ccccccccececeeeeceseeseeseseeseecseeeneneesees 2 PAS SSIMONY EE 3 Toos and EEN E EE 3 WSCA AU OM EE 3 Safety Intormaton eee eeceeeeeeeeeeeesaeeeeeaeeeeseaaeeeens 12 Steam Cabin Technical Gpecitcatons 13 User Manua EE 13 ECD DISD AV ef eet 13 CORI OM INC EEN 14 Steam Generator Cleanmg 18 Tree eet gege ee EES 19 customer service 1 866 855 2284 ei SIGNATURE HARDWARE signaturehardware com Arley Steam Shower Enclosure Installation and User Manual 1 STEAM SHOWER ENCLOSURE INSTALLATION Before you begin read the following installation and care instructions Observe all local plumbing building and electrical codes Unpack and inspect the product for any shipping damages If you find damages do not install Contact Customer Service at 1 866 855 2284 If you need assistance or have questions while installing your shower enclosure contact Customer Service We recommend that all plumbing and electrical rough in work be completed by a professional prior to shower enclosure assembly Signature Hardware accepts no liability for any damage to the enclosure walls floor or for personal injury during installation TECHNICAL INFORMATION e 220 volt 20 amp GFCI breaker e Line 1 line 2 and ground 1 dedicated line for steam e The size of breakers and wire gag
6. e cabin e Check to ensure the water supply valve has not been shut off Turn the water supply valve on if necessary e Remove the scale on the water level sensor and clean with warm water and a mild detergent Replace the scale if it appears to be broken e Make sure that the temperature setting is not lower than the room temperature Reset the temperature if necessary e Replace the thermal switch inside the heater e Ifall parts appear to be clean and in working order and problems persist it may be necessary to replace the heater If water does not stop being added to the steam generator e Replace the water inlet valve e Remove the scale on the water level sensor and clean with warm water and a mild detergent If problems persist it may be necessary to replace the scale If the unit will not turn ON e Replace the heater or thermal switch If water is leaking from the valve e Replace the valve seal If the water flow volume is low e Impurities in the water supply can clog the filter resulting in low water flow To remove clogs remove the filter and rise with warm water customer service 1 866 855 2284 signaturehardware com ei SIGNATURE HARDWARE Arley Steam Shower Enclosure Installation and User Manual 19
7. eal customer service 1 866 855 2284 signaturehardware com ei SIGNATURE HARDWARE Arley Steam Shower Enclosure Installation and User Manual 9 14 Run a bead of silicone sealant around the glass at the base of the shower encloser Allow sealant to dry for at least 24 hours before using your new steam shower 4 4 ZE 15 Install any decorative trim pieces T ei SIGNATURE HARDWARE customer service 1 866 855 2284 signaturehardware com Arley Steam Shower Enclosure Installation and User Manual 10 16 Connect the water supply and electricity Push the shower into place if necessary Use a screwdriver and rubber mallet to push the seal strips inside the door frame flush against the wall d yO ON nia A Ke CN CC CC CN 17 Install any remaining decorative trim pieces tA HHH TPE T Tet RSR M signaturehardware com customer service 1 866 855 2284 ei SIGNATURE HARDWARE Arley Steam Shower Enclosure Installation and User Manual 11 SAFETY INFORMATION e When using this unit basic safety precautions should always be followed e Children under the age of 16 should not be permitted to use the steam shower enclosure e Use this unit only for its intended purposes as described in this manual Do not use any additional attachments not recommended by the manufacturer e Never drop or insert objects into openings in the steam shower enclosure e
8. ed off the display and background light shuts off immediately while the drain valve for the steam generator remains running for one minute Ir Steam Temperature Setting The default steam temperature setting is 113 degrees To adjust the temperature push the Steam Temperature Setting button Image 3 until the desired temperature is reached When the cabin temperature reaches 4 degrees above the set temperature the steam generator automatically shuts off When the cabin temperature reaches 4 degrees below the set temperature the steam generator automatically turns on L Steam Timer Setting The default steam timer setting is 45 minutes To adjust the timer setting push the Steam Timer Setting button Image 4 until the desired time is reached The system automatically shuts off at the end of the specified time Image 4 customer service 1 866 855 2284 ei SIGNATURE HARDWARE signaturehardware com Arley Steam Shower Enclosure Installation and User Manual 15 CONTROL PANEL wy Me f SB Chromatherapy d Im The Chromatherapy button controls the color of the oo a F Po O M E A chromatherapy lights The chromatherapy symbol on the LCD display flashes when the chromatherapy lights are turned on Image 5 Press the Chromatherapy button to adjust the turn the lights on and off and to adjust the lights as desired Fan ON OFF The Fan button turns the ventilation fan on and off When the fan is running the fan sy
9. es is determined by local state and national codes as interpreted by the installing electrician PLUMBING REQUIREMENTS e This unit is equipped with hot and cold braided water supplies with 72 NPT pipe threads e Install hot and cold shut off valves with 72 male NPT pipe threads to connect to water supplies e Tighten all connections prior to installation e We recommend preparing the drain location with the shower enclosure base on site A drain pipe 2 in diameter is required hose can stretch 6 customer service 1 866 855 2284 signaturehardware com ei SIGNATURE HARDWARE Arley Steam Shower Enclosure Installation and User Manual 2 ASSEMBLY TOOLS AND MATERIALS Level Screwdriver Silicone Sealant Caulking Gun Adjustable Wrench Drill Set Square Rubber Mallet INSTALLATION 1 Set the shower tray in place Place a level on the tray and adjust the tray legs as necessary until completely straight Each leg should be touching the floor D ae N 2 Install the door frame by connecting the wall posts and top rail to the shower tray ST4X50 flat een Par flat head tapping screw he ge tapping screw ST4X50 flat head ST4X40 flat head tapping screw tapping re K AW customer service 1 866 855 2284 ei SIGNATURE HARDWARE signaturehardware com Arley Steam Shower Enclosure Installation and User Manual 3 3 Attach the side wall panel to the door frame and shower tray and secure with the assembly screws provided Sa
10. high potential for causing fetal damage during the early months of pregnancy Pregnant or possibly pregnant women should consult a physician regarding correct exposure e Obese persons and persons with a history of heart disease low or high blood pressure circulatory problems or diabetes should consult a physician before using the steam system e f using medication consult a physician before using the steam system as some medication may induce drowsiness or affect heart rate blood pressure and circulation Hyperthermia warning Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98 6 F The symptoms of hyperthermia include dizziness lethargy drowsiness and fainting The effects of hyperthermia include e Failure to perceive heat e Failure to recognize the need to exit the steam shower e _Unawareness of impending risk e Fetal damage in pregnant women e Physical inability to exit the steam shower e Unconsciousness WARNING The use of alcohol drugs or medication can greatly increase the risk of hyperthermia customer service 1 866 855 2284 signaturehardware com ei SIGNATURE HARDWARE Arley Steam Shower Enclosure Installation and User Manual 12 STEAM CABIN TECHNICAL SPECIFICATIONS Rated Power 3 0 KW Rated Voltage AC240V Rated Electric Current 16A Frequency 60 Hz Power Supply Location Wall Water Supply 2 NPT pipe thread
11. hot cold water Water Supply Location Wall Diameter of Drainage Pipe 1 72 flex pipe Length of Drainage Pipe 39 USER MANUAL LCD Display zech Fahrenheit Celsius Temperature Temperature Indicator T Timer Setting FM Radio Function FM Radio Volume FM Radio Channel Chromatherapy ON OFF by che Ve GS 10 Fan ON OFF 11 Steam ON OFF 12 Power ON Indicator 13 FM Radio Channel 14 MP3 ON OFF 2 3 A 5 6 T 8 9 E H Pa Ka ei II customer service 1 866 855 2284 signaturehardware com ei SIGNATURE HARDWARE Arley Steam Shower Enclosure Installation and User Manual 13 CONTROL PANEL Steam Cabin Control Parts zech LCD Display Control Panel Water Diverter Steam Outlet Hand Shower Set Oo dO N O a A O N 10 Steam Generator Cleaning Liquid Jet ei SIGNATURE HARDWARE Steam Temperature Sensor Water Volume Adjustment Water Temperature Adjustment Back Massage Jet Steam Cabin Control Panel Power ON OFF e Steam Temperature Setting Steam Timer Setting Fan ON OFF Chromatherapy Steam ON OFF MP3 Radio Volume Channel Radio Settings customer service 1 866 855 2284 signaturehardware com Arley Steam Shower Enclosure Installation and User Manual 14 CONTROL PANEL Push any button to light the display Image 1 Push the Power button to turn the system on Image 2 and off When the power is turn
12. mbol on the LCD display flashes Hold the Fan button in for 3 seconds to switch the display from Celsius to Fahrenheit Image 7 8 pais Ge Steam ON OFF i Push the Steam ON OFF button to turn the steam function on Image 9 When the steam function is on the steam ON OFF symbol flashes The steam function is automatically turned off when the cabin temperature reaches 4 degrees higher than the set temperature and on when the temperature drops to 4 degrees below the set temperature ei SIGNATURE HARDWARE customer service 1 866 855 2284 signaturehardware com Arley Steam Shower Enclosure Installation and User Manual 16 CONTROL PANEL A MP3 Press the MP3 button to select the MP3 function Adjust the channel to match the channel set on the MP3 emitter Hold the MP3 button in for 3 seconds to set the channel and volume e FM Radio ON OFF Push the FM Radio ON OFF button to turn the radio function on When the radio is on the FM Radio ON OFF symbol flashes The channel will default to that last selected GA Volume Channel Push the Volume Channel button with the radio on Image 12 to adjust the volume Push the 7 A buttons to make adjustments as necessary To change the channel press the button twice when the radio is Image 12 on Image 13 Push the Ki A buttons to scan Image 13 customer service 1 866 855 2284 ei SIGNATURE HARDWARE signaturehardware com