Home

Model 1700 Fog Machine - Operations Manual

image

Contents

1. B a SCO MODEL 1700 FOG MACHINE Operating Instructions Rev date December 2007 CE faSCOo Rosco Laboratories Inc arbor View Avenue Stamford CT 06902 USA 800 ROON set 708 ae pae 203 708 8919 info ros ROSCO MODEL 1700 Operations Manual TABLE OF CONTENTS INTRODUCTION be cites icis oiran aa 1 IMPORTANT SAPEGDARDS solaio ai 2 HOW THE MACHINE WORKS t prd Syene ENSE ERIS aiar 3 OPERATING INSTRUCTIONS s nean a a cuba tent ena cintasener qur tu vdtded 4 DO S AND DON TS s rele base e RR E EH Rdl en dees 7 MAINTENANCE aae i pia RER EE E OTE A E dea R A 8 FOG DISTRIBUTION selleria 8 ROSCO OFFICES eil ia i 9 LIMITED WARRANTY lele 10 STORAGE AND SHIPMEN T ettet eerte xti Des v ao E RO Na 10 FECHNICAL SPECIFICA TIONS doch nih ox da uns CREE Qr nM iano 11 OFTIONAL ACCESSORIES angle Al PARTS IDENTIFICATION GUIDE s eire eh conet atte un e session a euer nena etai 12 TROUBLESHOOTING GUIDE ido inti eie e UEHi lla 22 PARTS EIS T alla eri 23 INTRODUCTION This manual offers a detailed explanation of the operation of the ROSCO MODEL 1700 smoke machine To assure efficient and safe operation please take a few minutes to read this material The ROSCO MODEL 1700 smoke machine is a thermal aerosol generator designed for variable fog output It is part of a system the other basic component being the full line of Rosco fog fluids and they should always be used together These unique fluid formulations are safe w
2. DO NOT run the pump Running the machine without fog fluid can seriously damage the pump 6 TIMERS Model 1700 Page 4 12 07 The Rosco Model 1700 Remote Control is equipped with timers as standard epuipment To enable the timers push the grey TIMER ON button on the remote The green CYCLE LED will be lit To set the amount of time that the machine will make fog adjust the FOG ON knob To set the delay between bursts adjust the FOG OFF knob The range of time for both FOG ON time and FOG OFF time is 2 18 seconds NOTE The numbers indicated by the FOG ON and FOG OFF knobs are relative and should be used for reference only 7 DAISY CHAIN OPTIONAL The Rosco Model 1700 has the capability to control up to 4 machines from a single controller In this Daisy Chain process the machine that controls the others is called the MASTER and the others are called SLAVES Make sure that a Remote Control is attached to the MASTER machine as outlined in Step 2 and all Remote Controls are removed from all the SLAVE machines Connect a cable with a male 3 pin XLR connector at each end to the link socket on the top of the MASTER machine and connect the other end to the remote connection on the first SLAVE machine Repeat the process from the first SLAVE machine to the next As many as 4 machines may be operated from a single remote Operate the remote as outlined in Steps 5 and 6 above 8 DMX CONTROLLER OPTIONAL The Rosco Model 1700 has the option to b
3. transit Model 1700 Page 10 12 07 ROSCO MODEL 1700 TECHNICAL SPECIFICATIONS POWER REQUIREMENTS REMOTE CONTROL 120 volts 60 Hz 12 amps Volume Control 240 volts 50 Hz 5 2 amps Sequencers On time 2 18 seconds PARTICLE SIZE Off time 2 18 seconds 0 25 60 microns MAX FLUID CONSUMPTION DIMENSIONS 3 6 liters hour 60 ml min Height 8 5 in 21 6 cm Width 9 75 in 24 8 cm FUSE Length 19 5 in 49 5 cm 12 5 120v WEIGHT 22 5 Ib 10 3 kg OPTIONAL ACCESSORIES DMX INTERFACE Allows the machine to be operated from a lighting control console HOSE ADAPTOR Metal frame that connects ducting hose to machine Dimensions 4 in 10 2 cm x 6 75 in 17 14 cm DUCTING HOSE Flexible plastic hose connects to hose adaptor for ducting of fog Dimensions 4 in 10 2 cm x 25 ft 7 62 m Model 1700 Page 11 12 07 ROSCO MODEL 1700 PARTS IDENTIFICATION GUIDE Left View with Cover Removed Mains Switch 23711700E001 Mains Socket 23711700E007 Model 1700 Page 12 12 07 ROSCO MODEL 1700 PARTS IDENTIFICATION GUIDE Right View Main PCB and XLR view showing PEB and XLR s A 3 Pin male XLR Panel Mount 23711700E009 B 3 Pin female XLR Panel Mount 23711700E010 C Main PCB 240v 23711700E240 Main PCB 110v 23711700E110 Model 1700 Page 13 12 07 ROSCO MODEL 1700 PARTS IDENTIFICATION GUIDE Rear View with Remote resse 1700 Ny E Pet La rear view with remot T Mains Switch 23711
4. 2 E mail roscoaus rosco com au BRAZIL Rosco do Brasil Ltda R Ant nio de Barros 82 03401 000 Sao Paulo SP 55 11 6198 2865 E mail info brazil rosco com 12 07 LIMITED WARRANTY ROSCO LABORATORIES INC warrants to the original purchaser that the ROSCO MODEL 1700 will be free from original defects in workmanship and material for a period of twelve months from the date of purchase During the warranty period machines will be repaired or replaced at the option of ROSCO The warranty does not extend to any parts of the ROSCO MODEL 1700 that have been subject to misuse or accident Neither does the warranty cover any machine that has been opened modified or repaired other than by ROSCO or its designated repair station The warranty will not apply if procedures described in the Operations Manual are not followed It is the user s obligation to clean and maintain the ROSCO MODEL 1700 according to these instructions and to follow acceptable practices for handling electrical devices NOTE USE OF ANY FLUID OTHER THAN A ROSCO BRAND FLUID WILL VOID THE WARRANTY STORAGE AND SHIPMENT If you do not anticipate using your machine for an extended period prepare your machine for storage as follows 1 Perform maintenance as outlined in Maintenance section 2 Wipe the outside of the machine clean 3 Store in a sealed cardboard box 4 Whenever the unit is shipped considerable care should be taken in packing to avoid damage in
5. 700E001 Mains Socket 23711700E007 Model 1700 Remote 23711700R001 Model 1700 Page 14 12 07 ROSCO MODEL 1700 PARTS IDENTIFICATION GUIDE Rear View with Remote Removed A 3 Pin male XLR Panel Mount 23711700E009 This is where the remote plugs in Model 1700 Page 15 12 07 ROSCO MODEL 1700 PARTS IDENTIFICATION GUIDE Left View Pump and Fittings gt Pump 240V 23711700F240 Pump 110V 23711700F110 Fluid tube to heat exchanger part of HE assembly Elbow 1 8 x 4mm 23711700F001 Rubber connecting tube 23711700A002 Main power connection to pump When reconnecting power to the pump please ensure that the positive goes to the diode side of the of the two connectors this is marked on the pump body Rubber pump mountings part of pump assembly moaw Ty Model 1700 Page 16 12 07 ROSCO MODEL 1700 PARTS IDENTIFICATION GUIDE Top View Heat Exchanger Assembly closed a ONINUYM 3 8 e c E 5 A Hole in heat exchanger housing to access Thermal Trip Model 1700 Page 17 12 07 ROSCO MODEL 1700 PARTS IDENTIFICATION GUIDE Top View Heat Exchanger Assembly open E m view with heat exchanger lid removed Thermocouple attached to the heat exchanger Heat Exchanger Assy 240V 23711700H240 Heat Exchanger Assy 110V 23711700H110 Thermal Trip 23711700E005 Insulation Kit 23711700H001 a zn Model 1700 Page 18 12 07 ROSCO MODEL 1700 PARTS IDENTIFICATION GUIDE Remot
6. Re calibrate main PCB Replace main PCB Replace thermocouple Replace Main PCB Replace thermocouple 12 07 23711700H110 23711700H240 23711700H001 23711700E005 23711700E006 23711700F100 23711700F120 23711700F240 23711700F001 23711700A002 23711700F002 23711700F003 23711700F004 23711700F005 23711700E001 23711700E007 23711700E008 23711700E002 23711700E009 23711700E010 23711700E003 23711700E004 23711700E110 23711700E240 23711700A001 23711700A003 23711700A004 23711700A005 Model 1700 ROSCO MODEL 1700 PARTS LIST HEAT EXCHANGER Model 1700 Heat Exchanger Assy 110v Model 1700 Heat Exchanger Assy 240v Model 1700 Insulation Kit Model 1700 Thermal Trip Model 1700 Thermocouple FLUID SYSTEM Model 1700 Pump 100v 50Hz Model 1700 Pump 110v 60Hz Model 1700 Pump 240v 50Hz Model 1700 Elbow 1 8 x 4mm Model 1700 Rubber tube connector Model 1700 Pre drilled cap Model 1700 Filter Model 1700 Plastic hose clamp Model 1700 Fluid line ELECTRICAL SYSTEM Model 1700 Mains Switch Model 1700 Mains Socket Model 1700 Mains Cable Model 1700 Male XLR Connector Model 1700 3 Pin male XLR PM Model 1700 3 Pin female XLR PM Model 1700 Fuse 6 3A 240v Model 1700 Fuse 12 5A 115v Model 1700 Main PCB 110v Model 1700 Main PCB 240v Model 1700 Heatsink MISCELLANEOUS PARTS Model 1700 Rubber foot Model 1700 Cover screw Model 1700 Box Page 23 12 07
7. TE THE WARRANTY HOW THE MACHINE WORKS When the heat exchanger has reached proper operating temperature the operator switches power to the siphoning pump which draws the fluid from an external reservoir into the heat exchanger The fluid is rapidly heated and vaporized The vaporized fluid is then discharged through the nozzle into the atmosphere where upon mixing with the cooler air it turns into an aerosol consisting of millions of fine particles NOTE The terms fog and smoke are used interchangeable However the ROSCO MODEL 1700 does not produce smoke but a mist or aerosol Model 1700 Page 3 12 07 OPERATING INSTRUCTIONS 1 POWER HOOK UP Plug one end of the power cord into the dedicated socket located on the rear of the machine and the other end into a socket rated at the proper voltage and amperage The machine requires a dedicated power circuit Turn on the main power switch I O located at the rear of the machine 2 REMOTE CONTROL The remote control fits into a cavity on the rear of the machine The Model 1700 ships with the remote control already screwed in place and can be removed If it is not already plugged in plug the remote control into the socket in the cavity on the back of the machine Push the grey button marked POWER ON This will enable the electronics and the unit will start to heat up The red LED on the Remote Control should light up indicating that the electronics are enabled The red LED on the t
8. d for voltage current and length Check your local electrical code for the correct gauge extension cord If an extension cord shows signs of wear or gets warm to the touch discontinue its use and obtain a cord with a higher current rating Improper extension cords are not only hazardous but may result in poor machine performance due to excessive voltage drop 3 Never use any machine that shows signs of improper use Even slight damage may be an indication of a major problem If the machine looks questionable use it only under strict observation If the machine shows any unusual behavior disconnect machine immediately from power and send machine to a Service Center for repair 4 Do not operate the machine in a tightly confined space where the ambient temperature might exceed 135 F 57 C A continuous flow of air is required to maintain temperature within the machine housing Sensitive electronic components deteriorate rapidly under high heat conditions Operation of the machine in an enclosure of less than ten cubic feet one cubic meter is dangerous and automatically voids the warranty Enclosing any heating device so it is invisible to the operator creates a potential fire hazard no matter what the ambient temperature of the enclosure To do so with any high amperage device is to assume substantial risk Rosco strongly recommends against it 5 In any facility the smoke concentration should be controlled The smoke should never mask
9. e see OPTIONAL ACCESSORIES Make sure that there is an air space of 2 3 inches between the nozzle and any ducting hose Do not use ducting hose smaller than 4 inch diameter The ROSCO MODEL 1700 works properly only in a horizontal position Do not tilt the machine during operation Model 1700 Page 8 12 07 ROSCO OFFICES WORLDWIDE If the machine fails and repairs are required call or write the nearest Rosco office listed below or your local Rosco dealer UNITED STATES World Headquarters Rosco Laboratories Inc 52 Harbor View Avenue Stamford CT 06902 203 708 8900 800 767 2669 E mail info rosco com Rosco Laboratories Inc 1265 Los Angeles Street Glendale CA 91204 1 818 543 6700 800 767 2652 Rosco Service Center 1675 Brandywine Ave Suite B Chula Vista CA 91911 619 423 1985 800 468 0114 CANADA Rosco Laboratories Ltd 1241 Denison Street 44 Markham Ontario L3R 4B4 905 475 1400 888 ROSCO TO E mail info 9roscocanada com Model 1700 Page 9 UNITED KINGDOM Roscolab Ltd Blanchard Works Kangley Bridge Road Sydenham London SE26 5AQ England 44 0 208 659 2300 E mail marketing roscolab co uk SPAIN amp PORTUGAL Rosco Iberica S A C Oro 76 Poligono Industrial Sur 28770 Colmenar Viejo Madrid Espafia 34 918 473 900 E mail info spain rosco iberica com AUSTRALIA Rosco Australia Pty Ltd 42 Sawyer Lane Artarmon 2064 N S W Australia 02 9906 626
10. e Control remote removed from machine A Male XLR Connector 23711700E002 B Remote Knob 23711700R002 Model 1700 Page 19 12 07 ROSCO MODEL 1700 PARTS IDENTIFICATION GUIDE Main PCB with Heatsink view showing PCB amp heatsink removed from m c A Main PCB 240v 23711700E240 Main PCB 110v 23711700E110 B Heatsink 23711700A001 Model 1700 Page 20 12 07 ROSCO MODEL 1700 PARTS IDENTIFICATION GUIDE Main PCB Fuse and Calibration clase up of main PCE Calibration potentiometer for TEMPERATURE CONTROL Calibration potentiometer for PUMP SPEED SETTING Fuse 6 3 amp 240v 23711700E003 Fuse 12 5 amp 115v 23711700E004 D Positive terminal for the thermocouple E Negative terminal for the thermocouple QU Temperature recalibration Adjust the potentiometer A while taking a voltmeter reading between terminals D amp E in millivolts Reading should be 12 4 mv 0 2mv at the point where the heater switches off red LED goes out Once this has been done recheck meter reading to confirm the setting WARNING THE WHITE THERMOCOUPLE WIRE IS NEGATIVE AND THE BLACK IS POSITIVE IF THESE ARE ATTACHED INCORRECTLY THE HEATER WILL LOCK ON Pump speed recalibration Set the output level on the remote control to 2 Turn on the machine and slowly turn the potentiometer B until fog just begins to flow Model 1700 Page 21 12 07 ROSCO MODEL 1700 TROUBLESHOOTING GUIDE SYMPTOM Machine doe
11. e operated from a lighting control console that uses a DMX signal After removing the Remote Control attach the optional DMX Interface to the remote control connection Attaching DMX cable Plug a standard 5 pin DMX cable in the connection narked DMX IN on the remote Note that the DMX can pass through to another device by plugging another cable into the DMX OUT plug Setting the address To set the DMX address use the dip switches located on the DMX interface The dip switches are based on the binary system so the channel number must first be converted to a binary number See illustration When the dip switch is in the down position it is on When there is a valid DMX signal the LED next to the dip switches will light NOTE The Rosco Model 1700 uses one DMX channel Operating the unit Turn the power switch I O on If the DMX interface is plugged in the machine will automatically start to heat up This will be indicated by the red LED on the top of the machine When the machine reaches proper operating temperature the green LED on top of the machine will light When the proper DMX channel is given a non zero value the machine will make fog The fog volume will be proportional to the value of the channel setting Test Button There is a red momentary test button located on the DMX Interface This button is operable if the machine is on and the DMX interface is plugged in When the machine is at proper operating tempearture as designat
12. ed by the green LED on top of the machine pressing the Test Button will momentarily make fog Model 1700 Page 5 12 07 DMX INTERFACE ADDRESS 128 256 512 Binary columns coc oc o cro co m o LED indicating DMX signal Address Switches 1 234 526728 9 10 on wo I I Se ae eee ic e EM MU Z1 2 3 4 5 6 7 8 9 10 Z1 23 4 5 6 7 8 9 10 Address for Channel 19 Address for Channel 217 1 2 16 19 1 8 16 64 128 217 OFF ON Model 1700 Page 6 12 07 DO DO DO DO DO DO DO DO DO NOT DO NOT DO NOT DO NOT DO NOT DO NOT DO NOT DO NOT DO NOT DO S amp DON TS Read the entire manual before operating the machine and pay particular attention to all CAUTIONS AND WARNINGS Use ONLY Rosco manufactured fluids Use an extension cord which is properly rated for voltage current and length and which is free from nicks or other signs of wear Before each operating period check to see that the machine is clean and free of foreign objects Test first for dry smoke Turn the FOG switch on Place a piece of cardboard or paper 18 inches in front of the machine If the surface is at all wet return the machine to your dealer for servicing Ensure that the machine is adequately ventilated Use proper cau
13. emergency exits safety signs staircases or other safety constructions 6 After long use or if the machine is not properly set some liquid droplets or wet area may appear in front of the machine s outlet This liquid should be wiped up to prevent a condition where someone might slip and fall Model 1700 Page 2 12 07 7 Machines are designed for continuous use over an 8 hour day but to protect components it is wise to turn off the machine when it is not in use In permanent installations it is advisable to equip the circuit with a night cut off device 8 During the warm up phase and during operations people should not stand within one meter of the front of the machine Flammable material like paper fabric etc should never be placed directly on or around this equipment or any other electrical device with a heating element 9 The smoke should be blown into an open space and should not be directed at people or objects Never blow smoke on hot surfaces into glowing heating elements or into open flames The normally non flammable and non toxic smoke could react on very hot surfaces and be burnt or decomposed 10 Unauthorized repair or alteration of any safety devices can lead to improper operation and accidents Repairs should be performed only by an authorized Service Center WARNING USE OF ANY FLUID OTHER THAN ROSCO FOG FLUIDS OR MODIFICATION OR ATTEMPTED UNAUTHORIZED REPAIR OF THE ROSCO MODEL 1700 WILL IMMEDIATELY INVALIDA
14. hen used according to instructions They are water based and contain no petroleum distillate The operating temperature pump pressure and output nozzle orifice of the machine have beeen specifically set to maximize aerosolization of the Rosco fluid When used properly the system should operate for many years Model 1700 Page 1 12 07 IMPORTANT SAFEGUARDS READ AND UNDERSTAND THESE SAFETY PRECAUTIONS BEFORE OPERATING THE MACHINE FAILURE TO PROPERLY FOLLOW THESE PRECAUTIONS MAY LEAD TO A FIRE EXPLOSION OR ELECTRICAL SHOCK FOG FLUID HEALTH CAUTION VAPOR FROM THIS FLUID LIKE ANY OTHER COMMON MATERIAL IN A VAPORIZED STATE MAY BE IRRITATING TO OR CAUSE ALLERGIC SYMPTOMS IN SOME PERSONS WITH ALLERGENIC SENSITIVITY DO NOT EXPOSE AT CLOSE RANGE TO KNOWN ASTHMATICS 1 This machine uses electrical power at common commercially available voltages When directly contacted such voltages are hazardous to human life All precautions commonly applicable to the use of electric power generally are applicable to the use of this machine This machine is designed to operate from three wire power systems where one of the wires is a safety ground DO NOT disconnect the safety ground or use extension cords or cheater plugs to connect this machine to a two wire system Operation without a safety ground may result in a hazardous electrical shock 2 Check the current and voltage rating of your machine Extension cords must be properly sized and rate
15. ld be immediately turned off 3 After every operation only after the machine has cooled it should be wiped with a clean damp cloth or paper towel This practice prevents the build up of dirt and dust which may enter the machine and damage sensitive internal components Do not use solvents for cleaning Soap and water are effective 4 Before and after the machine is stored for an extended period the machine should be properly cleaned The best method for cleaning is using distilled or de ionized water To flush the machine turn it on and when ready to use put the fluid pick up tube into a container of distilled or de ionized water Run the water through the machine and flush for three minutes The tube should be removed from the water and the machine run until nothing comes out of the nozzle The machine should be immediately turned off 5 During use operation of all switches and indicator lights should be monitored Lights that blink or flicker when they should be on or off for example are an indication of problems in the machine s circuitry FOG DISTRIBUTION The fog distribution in an enclosed area depends on air flow and temperature Natural air movement air conditioning and other ventilation systems will affect movement of the fog Test under realistic conditions before using If a space must be filled very quickly move the machine up and down and side to side To conduct fog to particular areas use a hose adaptor and ducting hos
16. op of the machine should light as well indicating that the machine is heating up Note The Rosco Model 1700 Fog Machine will operate either from the Remote Control from a lighting control console using the optional DMX Remote Control see below or as a unit in a daisy chain see below 3 WARM UP Let the machine warm up for about eight minutes until the green LED on the top of the machine turns on The machine is now ready to use as long as the green LED remains on and the fluid reservoir contains fluid 4 FLUID DELIVERY Place either the 2 5 liter or the 4 liter size bottles of any Rosco fluid in the cavity located at the rear of the machine Place the end of the tube coming out of the top of the machine into the bottle A cap is provided that fits on the bottle NOTE The machine only works with uncontaminated Rosco fog fluids Other manufacturers fluids may cause spitting and serious clogging problems and could result in the production of an unhealthful aerosol The use of other fluids voids the warranty of the Rosco Model 1700 Fog Machine 5 PRODUCING FOG To produce fog push the red FOG button located on the remote control Push the switch again to stop producing fog The volume of the fog can be varied by turning the knob marked FOG LEVEL Note At higher outputs the machine will give a large burst and then ramp back the volume This is to allow the machine to run continuously and is normal CAUTION If the fluid bottle is empty
17. s not fog when READY light is on and fog button is pressed Machine pumps but has no output No smoke Machine pumps but has low output Reduced output Fog is wet and leaves a trail of fluid in front of the machine Machine spits hot fluid Thermal trip cuts out Model 1700 PROBLEM Broken fog switch on remote Defective Remote PCB Break in remote cable Loose wire on remote header on PCB Faulty pump Component failure on main PCB No fluid in bottle Fluid tube into machine is blocked or kinked Pump or fitting on pump is leaking air into the system Blocked heat exchanger Fitting on output side of pump leaking Metal tubing on input side of block leaking Heater block beginning to block Temperature of machine set too low Wrong fluid in machine Pump speed set too high Temperature of machine set too high Main PCB faulty Thermocouple faulty Heater block over temperature Thermocouple dead short Page 22 SOLUTION Replace fog switch Replace remote PCB Replace remote cable Recrimp wire into header Replace pump Test or replace PCB Fill bottle with fluid Replace fluid tube Reseal or replace fittings Replace heat exchanger Check that only Rosco fluid is being used Reseal or replace fitting Replace heat exchanger Flush block with de ionized or distilled water Re calibrate main PCB see page 22 Ensure only Rosco fluid is being used Recalibrate pump speed see page 22
18. tion when handling hot surfaces Use the minimum amount of smoke required to achieve the desired effect Use the machine near a person who has asthma or similar inhalation disorder Use any foreign substances in the machine Use a machine that is damaged or operating improperly in any way Use a machine that leaks fluid from the housing Leave the machine switched on for prolonged periods without producing fog Enclose the machine Install the machine in such a fashion that the operator cannot see the whole machine including indicator lights Touch the shielded nozzle of the machine Allow sufficient cooling time after operation before attempting to perform maintenance Direct the smoke continuously against the same spot This may eventually cause fluid to recondense on walls furniture sets etc READ THE COMPLETE MANUAL TO INSURE SAFE OPERATION Model 1700 Page 7 12 07 MAINTENANCE 1 The main fuse of the ROSCO MODEL 1700 smoke machine is located on the circuit card inside the machine NOTE Be sure to check the specifications when replacing any fuses WARNING DISCONNECT THE ROSCO MODEL 1700 FROM POWER BEFORE CHECKING OR REPLACING THE FUSE FAILURE TO DO SO COULD BE HAZARDOUS AND RESULT IN AN ELECTRICAL SHOCK 2 After every operation the siphon hose should be removed from the external reservoir The machine should be turned on and fog produced When there is no more fog coming out of the machine the machine shou

Download Pdf Manuals

image

Related Search

Related Contents

IMC-734 User`s Manual  Lettre de mission  Tiptel VP 28 LCD Wired handset Black  Gigabyte GA-B85TN motherboard  PDF  Bismark Bisulfite Mapper – User Guide - v0.12.4  Manuel d`instruction  Andrés Méndez  V7 Slide-In USB 3.0 Flash Drive 8GB black  Documentation Service Allo Mairie  

Copyright © All rights reserved.
Failed to retrieve file