Home
model g310c2/r2/s2 - 10.4" color touchscreen ulr
Contents
1. Remove the old battery from the holder and replace with the new battery Replace the rear cover cables and re apply power Using Crimson or the unit s keypad enter the correct time and date Please note that the old battery must be disposed of in a manner that complies with your local waste regulations Also the battery must not be disposed of in fire or in a manner whereby it may be damaged and its contents come into contact with human skin The battery used by the G310 is a lithium type CR2025 BATTERY WARNING EXPLOSION HAZARD BATTERIES MUST ONLY BE CHANGED IN AN AREA KNOWN TO BE NON HAZARDOUS OPTIONAL FEATURES AND ACCESSORIES COMPACTFLASH SOCKET CompactFlash socket is a Type II socket that can accept either Type I or II cards Use cards with a minimum of 4 Mbytes and formatted to a maximum of 2 Gbytes see Note box below with the G310 s CompactFlash socket Cards are available at most computer and office supply retailers CompactFlash can be used for configuration transfers larger configurations data logging and trending INDOOR VERSUS OUTDOOR The G310C2x0 and the G310R2x0 use an overlay with a textured finish and keys that are embossed This overlay is not rated for outdoor use The G310S2x0 uses an overlay with a glossy finish that uses a UV rated material for outdoor use The keys on this overlay are not embossed The display is significantly brighter than the G310C2x0 OPTIONAL COMMUN
2. instructions found in the Crimson user manual WARNING DO NOT CONNECT OR DISCONNECT CABLES WHILE POWER IS APPLIED UNLESS AREA IS KNOWN TO BE NON HAZARDOUS USB PORT IS FOR SYSTEM SET UP AND DIAGNOSTICS AND IS NOT INTENDED FOR PERMANENT CONNECTION CABLES AND DRIVERS Red Lion has a wide range of cables and drivers for use with many different communication types A list of these drivers and cables along with pin outs is available from Red Lion s website New cables and drivers are added on a regular basis If making your own cable refer to the G310 Port Pin Outs for wiring information ETHERNET COMMUNICATIONS Ethernet communications can be established at either 10 BASE T or 100 BASE TX The G310 unit s RJ45 jack is wired as a NIC Network Interface Card For example when wiring to a hub or switch use a straight through cable but when connecting to another NIC use a crossover cable YELLOW solid Link established YELLOW flashing Data being transferred GREEN 10 BASE T Communications AMBER 100 BASE TX Communications The Ethernet connector contains two LEDs A yellow LED in the upper right and a bi color green amber LED in the upper left The LEDs represent the following statuses The Crimson manual contains additional information on Ethernet communications RS232 PORTS The G310 has two individually isolated RS232 ports There is the PGM port and the COMMS port Although only one of these ports can be used
3. POWER SUPPLY REQUIREMENTS The units require a 24 VDC power supply rated at 26 W Your unit may draw considerably less than the rated power depending upon the options being used As additional features are used your unit will draw increasing amounts of power Items that could cause increases in current are additional communications optional communications card CompactFlash card and other features programmed through Crimson In any case it is very important that the power supply is mounted correctly if the unit is to operate reliably Please take care to observe the following points The power supply must be mounted close to the unit with usually not more than 6 feet 1 8 m of cable between the supply and the operator interface Ideally the shortest length possible should be used The wire used to connect the operator interface s power supply should be at least 22 gage wire If a longer cable run is used a heavier gage wire should be used The routing of the cable should be kept away from large contactors inverters and other devices which may generate significant electrical noise A power supply with an NEC Class 2 or Limited Power Source LPS and SELV rating is to be used This type of power supply provides isolation to accessible circuits from hazardous voltage levels generated by a mains power supply due to single faults SELV is an acronym for safety extra low voltage Safety extra low voltage circuits shall exhib
4. This operator interface uses a liquid crystal display LCD for displaying text and graphics The backlight can be dimmed for low light conditions Display backlights have a limited lifetime Backlight lifetime is based upon the amount of time the display is turned on at full intensity Turning the backlight off when the display is not in use can extend the lifetime of your backlight This can be accomplished through the Crimson software when configuring your unit BACKLIGHT REPLACEMENT G310S2 LED Backlight The LED backlight is not field replaceable Unit must be returned to Red Lion Controls for repair G310C2 R2 LED Backlight The LED backlight is field replaceable in non hazardous locations only Refer to the instructions included in the backlight replacement kit Contact Red Lion Controls for the appropriate part number FRONT PANEL LEDS There are three front panel LEDs Shown below is the default status of the LEDs LED INDICATION RED TOP LABELED PWR FLASHING STEADY Unit is powered and running an application OFF No CompactFlash card is present STEADY FLASHING RAPIDLY Unit is in the boot loader no valid configuration is loaded 1 Valid CompactFlash card present CompactFlash card being checked Unit is writing to the CompactFlash either because it is storing FLICKERING data or because the PC connected via the USB port has locked the drive 2 FLASHING SLOWLY GREEN BOTTOM F
5. 640X480 PIXEL LCD OR SVGA 800X600 LCD OUTDOOR UNIT WITH UV RATED OVERLAY AVAILABLE 8 BUTTON KEYPAD FOR ON SCREEN MENUS THREE FRONT PANEL LEDS POWER UNIT FROM 24VDC 20 SUPPLY RESISTIVE ANALOG TOUCHSCREEN ORDERING INFORMATION 10 4 TFT VGA Display Operator Interface indoor 3410C210 Dual Ethernet USB Host Isolated Comms 10 4 TFT SVGA Display Operator Interface indoor USB Host Isolated Comms 10 4 TFT SVGA Display Operator Interface indoor Dual Ethernet USB Host Isolated Comms 10 4 TFT VGA Display Operator Interface indoor or outdoor Glossy Finish USB Host Isolated Comms 7 10 4 TFT VGA Display Operator Interface indoor or outdoor Glossy Finish Dual Ethernet USB Host Isolated Comms 7 10 4 TFT VGA Display Operator Interface indoor USB Host Isolated Comms G310C230 G3CF G3GSM GSM GPRS Modem Option Card 3 G3GSM000 G3PBDP Profibus DP Optional Communication Card G3PBDP00 SFCRM SFCRM Crimson 2 CBLPROGO CBLUSBOO RS 232 Programming Cable CBL USB Cable Communications Cables 1 DR DIN Rail Mountable Adapter Products 4 Replacement Battery BNL20000 G3FILM Protective Films G3FILM10 1 Contact your Red Lion distributor or visit our website for complete selection 2 Use this part number to purchase Crimson on CD with a printed manual USB cable and RS 232 cable Otherwise download for free from www redlion net 3 Antenna G3QANTO00 is NOT included with the card Must be purchase
6. Type II slot for Type I and Type I CompactFlash cards 7 COMMUNICATIONS USB Port Adheres to USB 2 0 specification full speed only via Type B connection WARNING DO NOT CONNECT OR DISCONNECT CABLES i WHILE POWER IS APPLIED UNLESS AREA IS KNOWN TO BE NON HAZARDOUS USB PORT IS FOR SYSTEM SET UP AND DIAGNOSTICS AND IS NOT INTENDED FOR PERMANENT CONNECTION USB Host Ports Comply with Universal Serial Bus Specification Rev 2 0 Support data transfers at full speed Hardware over current protected 0 5 A max per port Serial Ports Ports are individually isolated Format and Baud Rates for each port are individually software programmable up to 115 200 baud PGM Port RS232 port via RJ12 COMMS Ports RS422 485 port via RJ45 and RS232 port via RJ12 DH485 TXEN Transmit enable open collector Voy 15 VDC Vor 0 5 V 25 mA max Note For additional information on the communications or signal common and connections to earth ground please see the Connecting to Earth Ground in the section Installing and Powering the G310 DIMENSIONS In inches mm 12 83 325 8 Ethernet Ports 10 BASE T 100 BASE TX RJ45 jack is wired as a NIC Network Interface Card The jack shield is electrically connected to Earth ground A secondary ethernet port with its own Mac ID is available as an option 8 ENVIRONMENTAL CONDITIONS Operating Temperature Range 0 to 50 C Storage Temperature Range 2
7. bulletin Template for panel cutout Hardware packet for mounting unit into panel Terminal block for connecting power SAFETY SUMMARY All safety related regulations local codes and instructions that appear in the manual or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it If equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired Do not use the controller to directly command motors valves or other actuators not equipped with safeguards To do so can be potentially harmful to persons or equipment in the event of a fault to the controller WARNING EXPLOSION HAZARD SUBSTITUTION OF ANY COMPONENT MAY IMPAIR SUITABILITY FOR CLASS I DIVISION 2 CAUTION Risk of Danger Read complete instructions prior to installation and operation of the unit A CONFIGURED USING CRIMSON SOFTWARE VERSION 2 0 OR LATER UP TO 5 RS 232 422 485 COMMUNICATIONS PORTS 2 RS 232 AND 1 RS 422 485 ON BOARD 1 RS 232 AND 1 RS 422 485 ON OPTIONAL COMMUNICATIONS CARD 10 BASE T 100 BASE TX ETHERNET PORT TO NETWORK UNITS AND HOST WEB PAGES 2P ETHERNET PORT OPTIONAL USB PORT TO DOWNLOAD THE UNIT S CONFIGURATION FROM A PC OR FOR DATA TRANSFERS TO A PC UNIT S CONFIGURATION IS STORED IN NON VOLATILE MEMORY 32MBYTE FLASH COMPACTFLASH SOCKET TO INCREASE MEMORY CAPACITY 10 4 INCH TFT 32K VGA
8. 0 to 70 C Operating and Storage Humidity 80 maximum relative humidity non condensing from 0 to 50 C Vibration to IEC 68 2 6 Operational 5 to 150 Hz 2 g Shock to IEC 68 2 27 Operational 35 g Altitude Up to 2000 meters 9 CERTIFICATIONS AND COMPLIANCES CE Approved EN 61326 1 Immunity to Industrial Locations Emission CISPR 11 Class A Safety requirements for electrical equipment for measurement control and laboratory use EN 61010 1 General Requirements RoHS Compliant UL Listed File E179259 UL Hazardous File E245515 Type 4X Enclosure rating Face only IP66 Enclosure rating Face only 0 CONNECTIONS Compression cage clamp terminal block Wire Gage 12 30 AWG copper wire Torque 5 7 inch pounds 56 79 N cm 1 CONSTRUCTION Steel rear metal enclosure with NEMA 4X IP66 aluminum front plate when correctly fitted with the gasket provided Installation Category II Pollution Degree 2 2 MOUNTING REQUIREMENTS Maximum panel thickness is 0 25 6 3 mm For NEMA 4X IP66 sealing a steel panel with a minimum thickness of 0 125 3 17 mm is recommended Maximum Mounting Stud Torque 17 inch pounds 1 92 N m 3 WEIGHT 5 44 Ibs 2 47 Kg INSTALLING AND POWERING THE G310 MOUNTING INSTRUCTIONS This operator interface is designed for through panel mounting A panel cut out diagram and a template are provided Care should be taken to remove any loose material from the mounting cut out to prev
9. 22 or RS485 RS422 485 4 WIRE CONNECTIONS RS485 2 WIRE CONNECTIONS TxEN OC TxEN OC GND Note All Red Lion devices connect A to A and B to B except for Paradigm devices Refer to www redlion net for additional information Examples of RS485 2 Wire Connections G3 to Red Lion RJ11 CBLRLCO00 DLC IAMS ITMS PAXCDC4C G3 RJ45 Name 5 Modular Controle DE RxB DH485 COMMUNICATIONS The G310 s RS422 485 COMMS port can also be used for Allen Bradley DH485 communications WARNING DO NOT use a standard DH485 cable to connect this port to Allen Bradley equipment A cable and wiring diagram are available from Red Lion G3 to AB SLC 500 CBLAB003 R45 RLC RG AB POWER SUPPLY ISOLATION BLOCK DIAGRAM POWER USB DEVICE 24vDC L SUPPLY PROGRAMMING I ISOLATED ISOLATED RS232 A rou rors PGM PORT ISOLATED RS232 PORTB HOSTE r ISOLATED Al ISOLATED AUXILIARY ETHERNET Juy ETHERNET SOFTWARE UNIT OPERATION CRIMSON SOFTWARE Crimson software is available as a free download from Red Lion s website or it can be purchased on a CD see Ordering Information for part number The latest version of the software is always available from the website and updating your copy is free DISPLAY
10. ICATION CARD Red Lion offers optional communication cards for fieldbus communications These communication cards will allow your G310 to communicate with many of the popular fieldbus protocols Red Lion is also offering a communications card for additional RS232 and RS422 485 communications Visit Red Lion s website for information and availability of these cards Note Do not remove or insert the CompactFlash card while power is applied Refer to wa Front Panel LEDs f CompactFlash Insert Face Up CUSTOM LOGO Each G3 operator interface has an embossed area containing the Red Lion logo Red Lion can provide custom logos to apply to this area Contact your distributor for additional information and pricing 7 T y pei Information stored on a CompactFlash card by a G310 can be read by a card heats g I reader attached to a PC This information is stored in IBM Windows PC compatible FAT16 file format ts 1 65 42 FRONT OVERLAY NOTE For reliable operation of this and other Red Lion products one of the following brands of CompactFlash card must be used SimpleTech SMART Modular swissbit SanDisk Silicon Systems Not all of the above manufacturers offer CompactFlash cards recognized to UL standards which may be required for your application Although RLC products limit use of CompactFlash card memory to 2 GB cards with a larger capacity can be used They MUST be formatted
11. LASHING Atag is in an alarm state STEADY Incorrectly formatted CompactFlash card present Valid configuration is loaded and there are no alarms present 1 The operator interface is shipped without a configuration After downloading a configuration if the light remains in the flashing state continuously try cycling power If the LED still continues to flash try downloading a configuration again 2 Do not turn off power to the unit while this light is flickering The unit writes data in two minute intervals Later Microsoft operating systems will not lock the drive unless they need to write data Windows 98 may lock the drive any time it is mounted thereby interfering with logging Refer to Mounting the CompactFlash in the Crimson User Manual KEYPAD The G310 keypad consists of eight keys for on screen menus TOUCHSCREEN This operator interface utilizes a resistive analog touchscreen for user input The unit will only produce an audible tone beep when a touch on an active touchscreen cell in sensed The touchscreen is fully functional as soon as the operator interface is initialized and can be operated with gloved hands TROUBLESHOOTING YOUR G310 If for any reason you have trouble operating connecting or simply have questions concerning your new G310 contact Red Lion s technical support For contact information refer to the back page of this bulletin for phone and fax numbers EMAIL techsupport redl
12. Tel 1 717 767 6511 Fax 1 717 764 0839 www redlion net Bulletin No G310CRS2 E Drawing No LP0809 Released 04 15 MODEL G310C2 R2 S2 10 4 COLOR TOUCHSCREEN m m m O m m m W z g FOR USE IN HAZARDOUS LOCATIONS Class l Division 2 Groups A B C and D c UL US LISTED 43NH PROCESS CONTROL EQUIPMENT GENERAL DESCRIPTION The G310 Operator Interface Terminal combines unique capabilities normally expected from high end units with a very affordable price It is built around a high performance core with integrated functionality This core allows the G310 to perform many of the normal features of the Paradigm range of Operator Interfaces while improving and adding new features The G310 is able to communicate with many different types of hardware using high speed RS232 422 485 communications ports and Ethernet 10 Base T 100 Base TX communications In addition the G310 features USB for fast downloads of configuration files and access to trending and data logging A CompactFlash socket is provided so that Flash cards can be used to collect your trending and data logging information as well as to store larger configuration files In addition to accessing and controlling of external resources the G310 allows a user to easily view and enter information Users can enter data through the touchscreen or front panel 8 button keypad CONTENTS OF PACKAGE G310 Operator Interface Panel Gasket This hardware
13. d separately if needed 4 Red Lion offers RJ modular jack adapters Refer to the DR literature for complete details 5 Battery type is lithium coin type CR2025 6 Industrial grade two million write cycles SMART Modular Technologies model SG9CF UL Listed Directory Category NWGQ 7 LED backlight may not be field replaceable Consult factory CompactFlash is a registered trademark of CompactFlash Association SPECIFICATIONS 1 POWER REQUIREMENTS Must use a Class 2 circuit according to National Electrical Code NEC NFPA 70 or Canadian Electrical Code CEC Part I C22 1 or a Limited Power Supply LPS according to IEC 60950 1 or Limited energy circuit according to IEC 61010 1 Power connection via removable three position terminal block Supply Voltage 24 VDC 20 G310C R G310S Typical Power 16 W 16 W Maximum Power 25 W 26 W Note 1 The G310 circuit common is not connected to the enclosure of the unit See Connecting to Earth Ground in the section Installing and Powering the G310 2 BATTERY Lithium coin cell CR2025 Typical lifetime of 10 years 3 LCD MODULE DISPLAYS C woo J cmoa J cmon cmosz BACKLIGHT LIFETIME Lifetime at room temperature Refer to Display in the Software Unit Operation section 4 8 KEY KEYPAD for on screen menus 5 TOUCHSCREEN Resistive analog 6 MEMORY On Board User Memory 32 Mbyte of onboard non volatile Flash memory Memory Card CompactFlash
14. e By configuring the G310 using the latest version of Crimson you are assured that your unit has the most up to date feature set Crimson software can configure the G310 through the RS232 PGM port USB port or CompactFlash The USB port is connected using a standard USB cable with a Type B connector The driver needed to use the USB port will be installed with Crimson If this driver has not been installed it can be downloaded from the website The RS232 PGM port uses a programming cable made by Red Lion to connect to the DB9 COM port of your computer If you choose to make your own cable use the G310 Port Pin Out Diagram for wiring information The CompactFlash can be used to program a G3 by placing a configuration file and firmware on the CompactFlash card The card is then inserted into the target G3 and powered Refer to the Crimson literature for more information on the proper names and locations of the files ACCESSING THE COMPACTFLASH CARD VIA USB DEVICE PORT In order to access data from the CompactFlash card via the USB device port a driver must be installed on your computer This driver is installed with Crimson and is located in the folder C Program Files Red Lion Controls Crimson 2 0 Device after Crimson is installed This may have already been accomplished if your G310 was configured using the USB port Once the driver is installed connect the G310 to your PC with a USB cable and follow the Mounting the CompactFlash
15. ent that material from falling into the operator interface during installation A gasket is provided to enable sealing to NEMA 4X IP66 specification Install the 14 kep nuts provided and tighten evenly for uniform gasket compression Note Tightening the kep nuts beyond a maximum of 17 inch pounds 1 92 N m may cause damage to the front panel 12 25 311 2 11 725 297 8 _____ 6 125 155 6 a 14X 188 24 8 All tolerances 0 010 0 25 mm ALL NONINCENDIVE CIRCUITS MUST BE WIRED USING DIVISION 2 WIRING METHODS AS SPECIFIED IN THE NATIONAL ELECTRICAL CODE NFPA 70 FOR INSTALLATION WITHIN THE UNITED STATES OR AS SPECIFIED IN THE CANADIAN ELECTRICAL CODE FOR INSTALLATION IN CANADA CONNECTING TO EARTH GROUND The chassis ground is not connected to signal common of the unit Maintaining isolation between earth ground and signal common is not required to operate your unit But other equipment connected to this unit may require isolation between signal common and earth ground To maintain isolation between signal common and earth ground care must be taken when connections are made to the unit For example a power supply with isolation between its signal common and earth ground must be used Also plugging in a USB cable may connect signal common and earth ground 1 USB s shield may be connected to earth ground at the host USB s shield in turn may also be connected to signal common
16. for programming both ports can be used for communications with a PLC The RS232 PGM port can be used for either master or slave protocols with any G310 configuration G310 PORT PIN OUTS TxA PIN 8 RTS PIN 6 PROTECTIVE ps EARTH GROUND 1 COMMON 2 24Vt20 POWER CONNECTOR COMMS USB HOST ETHERNET AUXILIARY NIC ETHERNET OPTIONAL Examples of RS232 communications could involve another Red Lion product or a PC By using a cable with RJ12 ends on it and a twist in the cable RS232 communications with another G3 product or the Modular Controller can be established Red Lion part numbers for cables with a twist in them are CBLPROGO CBLRLCO1 or CBLRC02 G3 RS232 to a PC CONNECTING A G310 OPERATOR INTERFACE TO AN ICM5 ICM5 DIP Switch Settings x o eae na pene xx lt ON NC 3 OFF DTE ONDCE 6 PULLUP 7 OFF DCE ONDTE 4 9600 BAUD 1 19200 BAUD 2 38400 BAUD 3 57600 BAUD 4 115200 BAUD 5 PULL DOWN 6 OFF 4 WIRE ON 2 WIRE 8 1209 TERMINATION 10 OFF 422 ON 485 1 OFF 422 ON 485 2 OFF DCE ONDTE 5 OFF DTE ONDCE 7 gt OFF 4 WIRE ON 2WIRE 9 x Application Dependent L CBLPROGO can also be used to communicate with either a PC or an ICMS 2 DB9 adapter not included 1 foot long 3 DB9 adapter not included 10 feet long RS422 485 COMMS PORT The G310 has one isolated RS422 485 port This port can be configured to act as either RS4
17. ion net Web Site http www redlion net BATTERY amp TIME KEEPING f WARNING EXPLOSION HAZARD THE AREA MUST BE KNOWN TO BE NON HAZARDOUS BEFORE SERVICING REPLACING THE UNIT AND BEFORE INSTALLING OR REMOVING I O WIRING AND BATTERY EQUIPMENT UNLESS POWER HAS BEEN DISCONNECTED WARNING EXPLOSION HAZARD DO NOT DISCONNECT AND THE AREA IS KNOWN TO BE NON HAZARDOUS A battery is used to keep time when the unit is without power Typical accuracy of the G310 time keeping is less than one minute per month drift The battery of a G310 unit does not affect the unit s memory all configurations and data is stored in non volatile memory CAUTION The circuit board contains static sensitive components Before handling the operator interface without the rear cover attached discharge static charges from your body by touching a grounded bare metal object Ideally handle the operator interface at a static controlled clean workstation Also do not touch the surface areas of the circuit board Dirt oil or other contaminants may adversely affect circuit operation To change the battery of a G310 remove power cabling and then the rear cover of the unit To remove the cover remove the five screws designated by the arrows on the rear of the unit Then by lifting the top side hinge the cover thus providing clearance for the connectors on the bottom side of the PCB as shown in the illustration below Install in the reverse manner
18. it voltages safe to touch both under normal operating conditions and after a single fault such as a breakdown of a layer of basic insulation or after the failure of a single component has occurred WARNING EXPLOSION HAZARD DO NOT DISCONNECT EQUIPMENT WHILE THE CIRCUIT IS LIVE OR UNLESS THE AREA IS KNOWN TO BE FREE OF IGNITABLE CONCENTRATIONS INSTALLING AN OPTION CARD WARNING EXPLOSION HAZARD DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN DISCONNECTED AND THE AREA IS KNOWN TO BE NON HAZARDOUS Each option card comes with a cable for communications and three screws for attaching the option card to the G3 s main board To install the option card remove all power and I O communications cables from the unit and remove the rear cover Connect the cable from the option card to the connector on the main board Be sure both ends of the cable are firmly seated into their appropriate connector housings Use the three screws provided to mount the option card to the main board as shown in Figure 1 Carefully replace the rear cover by reversing the instructions for removing the rear cover TYPICAL EXPANSION CARD INSTALLATION Figure 1 COMMUNICATING WITH THE G310 CONFIGURING A G310 The G310 is configured using Crimson software Crimson is available as a free download from Red Lion s website or it can be purchased on CD Updates to Crimson for new features and drivers are posted on the website as they become availabl
19. s contained herein and relies on no other warranties or affirmations Red Lion Controls Red Lion Controls Red Lion Controls Headquarters Europe 20 Willow Springs Circle Softwareweg 9 York PA 17406 NL 3821 BN Amersfoort Tel 1 717 767 6511 Tel 31 0 334 723 225 Fax 1 717 764 0839 Fax 31 0 334 893 793 Red Lion Controls India 201 B 2nd Floor Park Centra Opp 32 Mile Stone Sector 30 Gurgaon 122002 Haryana India Tel 91 984 487 0503 China Unit 1102 XinMao Plaza Building 9 No 99 Tianzhou Road ShangHai P R China 200223 Tel 86 21 6113 3688 Fax 86 21 6113 3683
20. to 2 GB and use the FAT 16 file system It is recommended to format the CF card using the format utility from within Crimson LIMITED WARRANTY The Company warrants the products it manufactures against defects in materials and workmanship for a period limited to two years from the date of shipment provided the products have been stored handled installed and used under proper conditions The Company s liability under this limited warranty shall extend only to the repair or replacement of a defective product at The Company s option The Company disclaims all liability for any affirmation promise or representation with respect to the products The customer agrees to hold Red Lion Controls harmless from defend and indemnify RLC against damages claims and expenses arising out of subsequent sales of RLC products or products containing components manufactured by RLC and based upon personal injuries deaths property damage lost profits and other matters which Buyer its employees or sub contractors are or may be to any extent liable including without limitation penalties imposed by the Consumer Product Safety Act P L 92 573 and liability imposed upon any person pursuant to the Magnuson Moss Warranty Act P L 93 637 as now in effect or as amended hereafter No warranties expressed or implied are created with respect to The Company s products except those expressly contained herein The Customer acknowledges the disclaimers and limitation