1. Note Use 18 AWG 0 82mm2 copper wire for power and ground lead connections Note Power conditioning may be required when the PanelMate unit is installed in areas of poor power quality Y GND ole A CAUTION Your PanelMate unit could be damaged if it is connected to voltages outside the range of 18 to 30VDC Your PanelMate unit is fully protected against polarity reversal and will not operate if input polarity is reversed A CAUTION If you are replacing a PanelMate Power Series 1500 unit check the rating of your existing 24VDC power supply The PanelMate 1700 unit requires a power supply rated for 1 5A operation Connection to a Personal Computer Executive firmware and PanelMate configurations are uploaded downloaded to a PC using the PanelMate unit s serial port A download serial cable is provided with your PanelMate Configuration software Refer to your PanelMate Power Series Getting Started Manual for more information Connection to the Fault Relay The fault relay may be wired in normally open or normally closed configuration It is a Form C contact rated for 2 amps at 120VAC 2 amps at 230VAC and 2 amps at 28VDC resistive load During normal operation the fault relay will energize after entering Run Mode Whenever the PanelMate unit detects a communication error or system failure the fault relay will be de energized It is also possible to de energize the fault relay whenever an alarm condition occurs
2. abrasive cleaning compounds will cause permanent damage to the touchscreen 5 Cutout Template A CAUTION A CAUTION Care should be taken when tightening the This cutout drawing is not 1 1 scale Refer to nuts The fasteners must be tightened the Express Setup sheet included with your enough to obtain a proper seal but not over PanelMate Power Series unit for a 1 1 template tightened to the point where the threads are stripped or the gasket is rendered useless Always use a torque wrench when installing your PanelMate Power Series unit 4 91 187 Diameter Hole 124 7 3 26 4 75 O 3 238 2 Cutout 6 50 pa 4 69 9 38 119 1 Torque Limits for Studs 5 inch pounds for 6 32 nuts Notes Dimensions are in inches Millimeter dimensions are in parentheses Specifications Temperature Operating 0 to 50 degree C grayscale amp TFT color 0 to 40 degree C dual scan color Non Operating 20 to 60 degree C Humidity non condensing Operating 20 80 grayscale 20 90 color Non Operating 20 90 grayscale 20 95 color NEMA Class NEMA 4 NEMA 4X or NEMA 12 Vibration Operating 1g at 10 500Hz Non Operating 1g at 10 500Hz Shock Operating 30g Non Operating 30g Pollution Pollution Degree 1 Rated for exposure to dry or non conductive pollutants only Altitude Operating 10 000 feet above sea level Non Operating 40 000 feet above sea level ESD Immunity Ai
3. You can set the fault relay to de energize on alarms by using the System Parameters Table Refer to the System Parameters topic in the Configuration Software Online Help and in the Configuration Editor User s Guide for more information Connection to the Audio Output The Audio Feedback Kit is an optional accessory to your PanelMate unit To connect the external 83O0hm speaker to your PanelMate unit connect the speaker to the Audio connector Connection to the Security Keyswitch The Security Keyswitch connection is provided for external security password applications Connection to Serial Ports Serial Port 1 may be used for a printer for PLC or Host communications or for connection to a personal computer for upload or download Serial Port 2 may be used for a printer or for PLC or Host communications Selection of Port 1 for a Serial Printer must be done with the Configuration Software Refer to the PLC Name and Port Table topic in the Configuration Software Online Help and in the PanelMate Power Series Configuration Editor User s Guide Serial Port Termination Your PanelMate unit is sent without termination For serial port termination switch locations refer to Figure A Recommended termination for RS232 DH485 and RS422 communication is shown in the table For setting the termination on Serial Port 1 use the termination switch on the left of Serial Port 1 For setting the termination on Serial Port 2 use the
4. EXPRESS SETUP PanelMate 1700 Series PanelMate Power Series Compressor Overview MR PERE anne 2 PanelMate ia AG A Installation Unpacking Carefully remove all equipment from the packing cartons and inspect all parts for damage in shipment Check packing cartons for all items shown on the packing list Keep the cartons and packing materials for future shipment Report any damage to the carrier who delivered the equipment then contact your Cutler Hammer distributor If you purchased the equipment from Cutler Hammer call the Order Processing Department at 614 882 3282 Note The Interstate Commerce Commission has a time limit on reporting concealed damage Parts Checklist Your packing carton contains one parts kit containing e 1 Packet of mounting nuts and washers e 2 Iwo terminal connectors audio output amp security keyswitch e 1 Three terminal connector 24VDC power e 1 Four terminal connector fault relay Mounting Your PanelMate Power Series unit is designed for NEMA 4 4X and 12 installations when properly mounted in a correspondingly rated enclosure Proper installation and enclosure sizing is essential to ensure long life and trouble free operation Your PanelMate unit should always be mounted in a vertical position Flat or angled mounting positions will shorten the unit s life Refer to Cutler Hammer s PanelMate Power Series Installation Guide for installation recommendati
5. Menu This menu displays six selections described below Enter Enter Execute Serial Diagnostics Display Network System Transfer Transfer Config Mode Mode Information Calibrate Touchscreen Execute Diagnostics This template allows you to perform a series of tests e Set Date and Time e Display test e Touchscreen test e Tone relay and battery test e Serial port test For information on performing these tests refer to your PanelMate Power Series Getting Started Manual Enter Serial Transfer Mode To download upload or read system information over a Serial port your PanelMate unit must be in Serial Transfer Mode For more information on downloading and uploading PanelMate Power Series configurations refer to your PanelMate Power Series Getting Started Manual Enter Network Transfer Mode Network transfer mode is used to read system information over a remote network or remotely place your PanelMate unit into Run Mode For more information refer to your PanelMate Transfer Utility User s Manual Display System Configuration Information This selection displays your PanelMate unit s current configuration Your PanelMate unit is shipped with a demonstration PanelMate Power Series configuration Once you have downloaded a new configuration this information will be updated to reflect the new configuration information Enter Run Mode Run Mode allows you to display the configuration downloaded to the Pan
6. elMate unit and communicate to the PLC of your choice If a new configuration has not been downloaded the unit will display the demonstration configuration For more information on Run Mode refer to your PanelMate Power Series Getting Started Manual Calibrate Touchscreen Touchscreen units have a calibration routine that must be performed to determine the boundaries of the video on your touchscreen Refer to Touchscreen Information for instructions on calibrating the touchscreen Display Contrast Adjustment Units equipped with grayscale or dual scan color displays feature software controlled contrast adjustment To adjust the contrast follow these steps 1 Place the unit in Run Mode 2 Select the Get Page control button from the default control buttons 3 Select the More control button 4 Select the Setup Page control button 5 Select the Adjust Contrast control button and use the Lighter and Darker control buttons to adjust the display s contrast To save the new setting press the Save Setting control button To revert to the previous contrast setting press the Cancel key The unit will return to the last saved contrast level after power is cycled to the unit PanelMate Operation The most basic job of a PanelMate unit is to replace the functions of hard wired operator station devices such as pushbuttons lamps and message displays To replace these devices the PanelMate unit supplies a template During o
7. emplate on the Offline Mode Menu To access the calibration in Run mode 1 Select the Get Page control button from the default control buttons 2 Select the More control button 3 Select the Setup Page control button 4 Select the Calibrate Touchscreen control button 5 Press the Execute control button Although the Offline and Run mode calibration screens are slightly different in appearance they both use the same calibration process To calibrate press the eight boxes crosshairs located around the screen edges You may press them in any order but all must be pressed to calibrate Each box crosshair will turn green different shade of gray on grayscale units when pressed After the first pass the boxes crossharis will change color to indicate the screen is ready for the second pass Again press all eight boxes crosshairs around the screen edge When you have pressed the last the unit will return to normal operation 10 27 53 Press these boxes crosshairs twice in order 1 2 3 4 1 2 3 4 Touchscreen Calibration Program Copyright c Cutler Hammer 1996 All rights reserved CANCEL PRESS AND HOLD EACH BOX ALONG EDGES FOR 1 SEC Pass 1 of 2 A CAUTION Never use foreign objects pens screwdrivers or similar to activate the touchscreen Foreign objects may damage the touchscreen causing unreliable operation or failure Do not use solvents or other harsh cleaning compounds on the touchscreen Solvents and
8. ons The Guide is available on the Cutler Hammer web site www cutlerhammer eaton com automation Panel cutout dimensions and stud torque limits are shown on the reverse side of this Express Setup sheet Note Stud nuts must be tightened enough to obtain a proper seal but not over tightened to the point where the threads are stripped or the gasket is rendered useless Always use a torque wrench when installing your PanelMate Power Series unit Safety Considerations This equipment is suitable for Class Division 2 Groups A B C D or non hazardous locations only A EXPLOSION HAZARD SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS 1 DIVISION 2 A RISQUE D EXPLOSION LA SUBSTITUTION DE COMPOSANTS PUET RENDRE CE MATERIAL INACCEPTABLE POUR LES EMPLACEMENTS DE CLASSE 1 DIVISION 2 A WARNING EXPLOSION HAZARD DO NOT REPLACE COMPONENTS UNLESS POWER HAS BEEN SWITCHED OFF OR AREA IS KNOWN TO BE NON HAZARDOUS A ADVERTISSMENT RESQUE D EXPLOSION COUPER LE COURANT OU S ASSURER QUE L EMPLACEMENT ES DESIGNE NON DANGEREUX AVANT DE REPLACER LE COMPOSANTS CAUTION ADVERTISSMENT 2 Connections Connect DC Power Your PanelMate unit operates at 24VDC 15 20 A removable three position DC power connector attaches to the unit s connector receptacle as shown in the diagram below The DC input common terminal and the chassis GND terminal are both internally connected to the PanelMate chassis
9. peration you can select a template to arm control buttons or numeric entry Once a template has been selected or armed you can press any desired control button to take action The touchscreen is designed for finger or gloved operation only and does not require the same actuation force as a mechanical switch A light touch will produce the same result as a heavy one For more information refer to your PanelMate Power Series Online Operation User s Guide Pressing directly on the display will activate a template Touchscreen Cleaning A Cleaning Mode utility is provided to make touchscreen cleaning safe and easy To access it 1 Place the PanelMate unit is Run Mode 2 Select the Get Page control button f 3 Select the More control button 4 Select the Setup Page control button 5 Select the Cleaning Mode template 6 Press the Execute control button After pressing the Execute button the Cleaning Mode screen will appear While this screen is displayed the touchscreen will not respond to your tough After you have finished cleaning the touchscreen you must return to normal operation by pressing the screen s numbered corners in sequential order 1 2 3 4 TOUCH KEYS 1 2 3 4 IN SEQUENCE TO UNLOCK A TouchPanel Information Touchscreen Calibration You can calibrate your unit s touchscreen in both Offline and Run modes To access the calibration screen when in Offline mode select the Calibrate Touchscreen t
10. r IEC 1000 4 2 Level 4 15kV Contact IEC 1000 4 2 Level 4 8kV Radiated Immunity IEC 1000 4 3 10V m 27mHz to 1GHz 80 AM modulation Conducted Immunity IEC 1000 4 6 10V from 150kHz to 80mHZ 80 AM modulation with 1kHz sine wave Surge Immunity IEC 1000 4 5 2kV Radiated Conductive CISPR 22 Class A Emission Electrical Fast Transient IEC 1000 4 4 Level 3 2kV on power lines 1kV on I O lines Line Frequency Magnetic IEC 1000 4 8 Level 3 30A m at 50Hz Field Immunity and 60Hz Voltage 24VDC 15 20 28W with Fieldbus Interface installed 24VDC 15 20 23W without Fieldbus Interface installed Current 1 3A with Fieldbus Interface installed 1 1A without Fieldbus Interface installed Peak Inrush Current 5A Serial Port Rate Selectable 110 to 38 400 baud Serial Port 1 Configuration DB9S connection selectable for RS232 RS422 or RS485 2 signal levels Serial Port 2 Configuration DB9S connection selectable for RS232 RS422 or RS485 2 signal levels Weight 4 Lbs 5 Lbs with Fieldbus interface attached Support Services Technical Support 1 800 809 2772 Voice 1 614 882 0417 Fax Information Fax Back 614 899 5323 Website http www cutlerhammer eaton com automation Technical Support E mail chatechsupport ch etn com Cutler Hammer 173 Heatherdown Drive Westerville OH 43081 614 882 3282 P N 01 00401 03
11. termination switch to the right of Serial Port 2 Communication Position RS 232 DH 485 RS422 RS485 OONOOAHRWNMY W 5 Description RS422 Transmit Data Output RS232 Receive Data Input RS232 Transmit Data Output RS422 Receive Data Input Signal Ground RS422 Transmit Data Output RS232 Request to Send Output RS232 Clear to Send Input RS422 Receive Data Termination 1 None factory Setting 4 120 Ohm AC coupled 2 amp 3 Refer to your PLC Communications Driver Manual for termination information SERIAL PORT 1 SERIAL PORT 2 120QAC 24V KYSW 4200 2200 ds NONE La RS232 h 0l 120QAC Se NONE RS232 FAULT RELAY Figure A A CAUTION Your PanelMate unit is equipped with isolated serial ports for improved communications reliability If you are replacing a 120VAC Power Series unit or a Power Series 1500 unit and are using an RS422 or RS485 cable for PLC communications you will need to install a new cable equipped with a ground wire Consult your PLC Communications driver manual or contact Cutler Hammer Support Services for more information 3 Tests amp Adjustments PanelMate Diagnostic Tests When power is applied to you PanelMate unit the unit will display a listing of internal diagnostic checks as they are executed After completing its internal diagnostic checks the unit will display the Offline Mode