Home
DG35 Keypad User Manual Specifications
Contents
1. MMMM MMMM Alarm Detection Mode MMMM MMMM MMMM MMMM MMMM MMMM MMMM MMMM TTT 001 to 999 sec Default TTT 030 Disable Default Force Open Incorrect Code Protect Force Open Incorrect Code Protect User Code Length MMMM MMMM L 2to8 Always OFF Always ON Default ON for 10sec for any key press Delete All User MMMM MMMM Page 8 9 Delete all Realy 1 User Delete all Realy 2 User Keypad User Manual Preliminary Rev 0 2 21 Jan 2010 1 21 Page 9 9
2. Keypad User Manual Preliminary Rev 0 2 21 Jan 2010 1 21 DG35 Keypad User Manual Specifications LINGE NEL ML Operating Voltage 12 24 VAC DC Current Draw TBA Input request to exit for Relay 1 time out reed switch contact for Relay 1 Output Relay 1 N O N C Com Output free voltage contact 2A Relay 2 N O N C Com Output free voltage contact 2A Strike Time 1 99 seconds adjustable Strike mode Access Timer or Latch Memory Volume 80 80 PIN codes Relay 1 is controlled by 001 080 user slots Relay 2 is controlled by 081 160 user slots DOOR SENSOR INPUT REED for Relay 1 only Normally closed N C connect to COM through a normally closed magnetic door switch The system will monitor the position of the door and will give the following functions Note To enable the Door sensor function you MUST connect REED to COM before power up the keypad It the pin remain open the keypad will disable the REED function Output Automatic Relock Function Automatic Relock Function is cooperating with the REED input The feature turns the Lock output from on to off 1 second after the door is detected close gt Door Forced Open A door forced open is where the door has been opened but a user code or PB has not been used to Page 1 9 Keypad User Manual Preliminary Rev 0 2 21 Jan 2010 1 21 gain access When this condition occurs the Alarm output will active and will remain ac
3. be heard and GREEN LED will change from flash to ON Ifthe entered code is already used by other user long beep tone will be heard which mean the new code in not added 3 Press to exit from the programming mode or program other operating Note 2 Same user code cannot be shared with more then one user or master code 3 Add PIN codes to Relay 2 Enter the Programming mode Enter the slot position code T x080 1604 example 058 Press K088 If the position is empty RED LED Flash Otherwise RED LED stay ON 2 Input PIN codes example 40088 Press 0088 4 For a successful added user beep will be heard and RED LED will change from flash to ON If the entered code is already used by other user long beep tone will be heard which mean the new code in not added 3 Press to exit from the programming mode or program other operating Note 2 Same user code cannot be shared with more then one user or master code Page 5 9 Keypad User Manual Preliminary Rev 0 2 21 Jan 2010 1 21 To Program Relocking Timer Enter the Programming mode Relay 1 Relay 2 Press program item 3004 Press program item 400 n Followed by the number of seconds that the relay should open 01 99 seconds 004 latch mode Followed by the number of seconds that the relay should open 01 99 seconds 004 latch mode Exa
4. lay 1 Active ON Relay 1 Position Occupied Programming Mode Program Relay 1 Timer Stand By Flash Programming Mode Relay 2 Position Empty RED Stand By Relay 2 Active ON Relay 2 Position Occupied Programming Mode Program Relay 2 Timer Page 4 9 Keypad User Manual Preliminary Rev 0 2 21 Jan 2010 1 21 Operation Instruction Enter Program Mode 1 Compose twice the master code 2580 3 beeps Blue LED become flash fast flash you are now in the programming mode 2 After 60 seconds if you have not entered any codes or data the system will automatically exit from the programming mode Exiting from the program mode Press 1 to exit from the programming mode Changing the Master codes Enter the Programming mode 1 Enter 0004 2 Followed by the new master code 3 Followed bya 1 4 beep 5 enrolled 6 Exit from the programming mode or program other operating Master Code can be change any time in the programming mode but the code length can only be changed when the user slot is empty When the user slot is empty Master code length can be selected from 2 to 8 digit Add PIN codes to Relay 1 Enter the Programming mode 1 Enter the slot position code T 001 080 example 006 Press x 0064 Ifthe position is empty GREEN LED Flash Otherwise GREEN LED stay ON 2 Input PIN codes example 0060 Press 00604 X Fora successful added user beep will
5. mple 5 seconds Press 051 Example 5 seconds Press 051 3 beep 3 beep 4 enrolled 4 enrolled 5 Press 1 to exit from the programming 5 Press 3 to exit from the programming mode or program other operation item mode or program other operation item Latching mode Correct code entered opens the relay and the relay stays open until the correct code is entered again To Delete a User Code Enter the Programming mode Press 1 to exit from the programming mode or programming code for other 1 Enter program item 500 2 Press the slot position code of your choice to delete example 006 x 006 3 beep 4 deleted 5 programming item Alarm Output Time Enter the Programming mode 1 Enter program item 501 2 Enter 3 digit alarm output time from 000 to 999 3 Beep 4 Enrolled 5 programming item Alarm Detection Mode Enter the Programming mode 1 Enter program item 502 2 Enter single digit alarm detection mode 0 Disable 1 Door Force Open 2 Incorrect Code Protect 3 Door Force Open or Incorrect Code Protect Press j to exit from the programming mode or programming code for other 3 Beep 4 Enrolled 5 Press 1 to exit from the programming mode or programming code for other programming item Page 6 9 Keypad User Manual Preliminary Rev 0 2 2 Jan 2010 1 21 H Changing User Digit C
6. ode length Enter the Programming mode Owe ROER Note Enter 7614 Followed by the new code length 2 to 8 digit beep enrolled Press j to exit from the programming mode or 4 programming code for other programming item This operation can only be done when it is new install or no user is save in the memory Back Light Mode Enter the Programming mode l 2 T Enter 7644 Enter single digit back light mode 0 Always Off 1 Always On 2 On for 10 seconds after any key press beep enrolled Press j to exit from the programming mode or programming code for other programming item Restore Master Code s ane rok Pur Short SYSTEM RESTORE terminal for five seconds 5 audible beeps heard Master Code is reset to 25804 Disconnect SYSTEM RESTORE terminal Done Default Value Master Code 2580 Relay 1 Timer 5 Relay 2 Timer 5 Digit Code Length 4 Connection Diagram Page 7 9 Keypad User Manual Preliminary Rev 0 2 21 Jan 2010 1 21 Quick Programming Guide 000 NNNN NNNN New Master Code Default MMMM 2580 Add User Code MMMM XXX User ID UUUU User Code Output 1 Timer MMMM TT 00 Toggle Mode TT 01 to 99 sec Default TT 05 Output 2 Timer MMMM TT 00 Toggle Mode TT 01 to 99 sec Default TT 05 Delete User MMMM MMMM XXX User ID Alarm Output Time
7. tive for the programmed alarm output time gt Door Propped Open A door propped open condition is defined by the situation where the door has been opened but has not closed after 60 seconds the lock timer is time out In this situation it triggers the Alarm output until the programmed alarm timer timeout ALARM OUTPUT AL Out 500mA 12VDC DC 12V 500mA negative signaling circuit output to alarm device Operates when a Door Forced or Propped Open alarm occurs or when Incorrect Codes Protection is activated Page 2 9 Keypad User Manual Preliminary Rev 0 2 21 Jan 2010 1 21 MASTER CODE RESET Tamper NO Tamper COM Tamper NC Relay2 NO Relay2 COM Relay 2 NC P B Relay 1 NO AL OUT Relay 1 COM POWER Relay 1 NC Power Operating Temperature TBA Ambient Humidity TBA Factory Master Code 2580 Master and User Code Length 2 to 8 digit EXE X0 EEPROM Non volatile memory System will retain all programs and codes after a total loss of power Page 3 9 Keypad User Manual Preliminary Rev 0 2 21 Jan 2010 1 21 The indicator signal chart LED m i Mode Status Stand By Fast Flash Programming Mode In Programming Mode Stand By Stand By BLUE Slow Flash Programming Mode Stand By ON Programming Mode Stand By Flash Programming Mode Relay 1 Position Empty GREEN Stand By Re
Download Pdf Manuals
Related Search
Related Contents
Fiche descriptive sur les zones humides Ramsar - INPN HONDA XR230 Samsung SCX-4500 Uporabniški priročnik 消防訓練センター維持管理費 Centrale des Moins Mobiles via Internet Manuel d`utilisation Rebuild HFB64 - Centennial College La Lettre du Sytevom Storm™ - GE Healthcare Life Sciences Digital Diesel Control cette fiche d`inscription Copyright © All rights reserved.