Home

Certified Lift Truck Scale with SimulCastTM Instrument User`s Manual

image

Contents

1. 14 F to 104 F NTEP 40 F to 140 F Operational 10 C to 40 C 40 C to 60 C Stainless steel enclosure 10 5 H x 10 75 W x 4 D 26 67 cm x 27 31 cm x 10 16 cm 9 lb 4 1 kg 4 Certified Lift Truck Scale with SimulCast Instrument User s Manual Daily Operation Quick Reference Below is a brief overview of how to use this system during a work shift Complete in structions are covered in the body of this manual Attention 1 At start of shift enter employee ID num ber Press any key to turn the unit on 2 Enter a PRO number in the unit using the bar code wand or keying it in on th Press and hold ek d at af i Onis CLEAR to turn the numeric keypad of the simulCast unit off 3 Key in the weight listed on the shipping papers 4 Edit the number of skids if different than the default value of 1 5 Weigh the skid or skids contained in that PRO and store the weights 6 Close the PRO 7 Enter a new PRO and repeat until the shift ends or until you are required to download the stored information Certified Lift Truck Scale with SimulCast Instrument User s Manual 5 Introduction Front Panel This manual will explain the operation of the WI 130 SimulCast indicator when used with the Quik Tach Lift Truck Scale Certified QTLTSC This manual is divided into the following sections e Daily Operation Quick Reference e Introduction e Daily Operation e The MORE Key The WI 130 indicator o
2. July 2008 LTSC_SC_U P65 PN 29659 0011 Issue AJ Printed in USA LEL e mO xe al p 1c Tableof Contents aeea rae re eee ne a nar ee er ereee nar roan nee 3 Specifications nonner an aa E EEEE EEEa aE NA 4 Daily Operation Quick Reference ccceceescececeeeeeeeeeeeeeeeeeeeeeeeeeaeeeeeeeeeeeeeeee 5 IMVOGUGUIO Mists EEA TA A E T 6 Front Panelni e at eae a a E a T ee Sk eee te 6 Dal Operatio Manr A E A A 7 Start Up and Entering Employee ID ssssssssssenesessssennnreesserrrrnnnsserrrrrnnnneseet 7 Entering the PRO and Estimated Weight eeeeeeeeeeeeeeeeeetteeeeeeeeeees 8 Welgh SKIdS eread a araa eaa E Ea a aT AE ATENE AEE GARS 10 Downloading Information 0 ccceseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeecneeeeeeeeeeeseeeeneeeeees 11 Th MORE keyed a EE e Ar a erei aiaa eieiei 12 OVENI W a ai ec we ay cde ae dae sence ee eek eh 12 EDIT Sonkey ina en a A a a a 12 CAL Softkey for Testing Accuracy esssseeeeseessssrrrrtnrrrrrrrnnnnnnssserrrrnnnn nee 13 SETUP SONKO Y e a aa E E AE Ee ee eee 14 RESE I SOnKGYy manane aa a a EEE A EA E EE e 16 EXIT SOKE inanan e E etic lat et eel ececestats 16 Rep rt Format ssis cisaat k aian ai k aeania diada ainda diada ada daiaire 17 Special characters or sequence of characters cccccceeeeeeeeeeeeeeeeeeeeeeeeeees 17 Headers and or identifiers ci aici ann Anya nl eae ean 17 Sample Printout Format recassa nn treet alee eau debe E E aa eerste 17 Sample MLO Gs ie
3. BD and ED These characters will be sent to allow the parser you are writing to identify the transaction data BC and EC These characters will be sent to allow the parser you are writing to identify the calibration data BH Report Type S CRLF Address Field 1 S CRLF Address Field 2 S CRLF Address Field 3 S CRLF Address Field 4 S CRLF Towmotor ID Number S CRLF Scale ID Number S CRLF Present Time S CRLF Present Date S CRLF EH BD Pro Number N Pro Number Status S Employee Number S Last Transac tion Time S Last Transaction Date S Actual Accumulated Weight SP Current Unit of Measure S Actual Number of Skids N Estimated Accumulated Weight SP Current Unit of Measure S Estimated Number of Skids N CRLF Pro Number N Pro Number Status S Employee Number S Last Transac tion Time S Last Transaction Date S Actual Accumulated Weight SP Current Unit of Measure S Actual Number of Skids N Estimated Accumulated Weight SP Current Unit of Measure S Estimated Number of Skids N CRLF Certified Lift Truck Scale with SimulCast Instrument User s Manual 17 One complete PRO record End of report information Sample Printout Pro Number N Pro Number Status S Employee Number S Last Transac tion Time S Last Transaction Date S Actual Accumulated Weight SP Current Unit of Measure S Actual Number of Skids N Estimated Accumulated Weight SP Current Unit of Measure S Estimated Number of Skids N CRLF
4. Scale Capacity Exceeded Transaction Aborted The scale is in an overload or underload state Blanking Enabled Transaction Aborted The system has exceeded the maximum calibration angle Blanking Enabled Zero Aborted The system has exceeded the maximum calibration angle Transaction Aborted Motion Detected The scale has a motion condition the transaction is aborted Zero Aborted Motion Detected The scale has a motion condition the zero is aborted Transaction Aborted Invalid Pro There is no active pro number in memory transaction aborted Transaction Aborted Under Weight The weight on the scale has not gone above the minimum weight limit defined in the lt SETUP gt key Below are service related error messages Check Proms The firmware chips are corrupted and need to be replaced Blank EE The EEPROM IC is blank Factory defaults or the backup copy of configuration settings will be used Replace EEPROM IC which will force a recalibration Check EE The EEPROM IC is not responding Factory defaults or the backup copy of configuration settings will be used Replace EEPROM IC which will force a recalibration Overload The weight on the scale has exceeded the capacity of the system Remove weight or troubleshoot equipment for defects Underload The weight on the scale has exceeded the capacity of the system Add weight or troubleshoot equipment for defects Over Angle The angle of the
5. The follow is displayed ENTER PASSWORD _ BKSP amp CHRT CHRY fabyv gt f If an invalid password is tried the display will return to the 2 Key in your password using the normal weight display mode numeric keypad or the softkeys if your password has letters After the password is keyed in press the ENTER key The following is briefly displayed Clearing Memory The following is briefly displayed Memory Cleared The display returns to the normal weighing mode EXIT Softkey Press the EXIT F5 key to return to the normal weighing mode display 16 Certified Lift Truck Scale with SimulCast Instrument User s Manual Report Format Special characters or sequence of characters Headers and or identifiers Sample Printout Format Beginning of report information One complete PRO record One complete PRO record Below are the parameters used to generate reports This will help in designing the database used to manage the information gathered from the SimulCast system Delimiter between information fields N numeric field only S string field only SP Space CR carriage return LF line feed The weight readings themselves will always be numeric only but the current unit of measure will be a string i e LB which forces the whole field to be a string BH and EH These characters will be sent to allow the parser you are writing to identify the header information
6. ED BC Test Weight ID Number S CRLF Test Weight Value SP Current Unit of Measure S CRLF Measured Weight SP Current Unit of Measure S CRLF Calibration Date S CRLF Calibration Time S CRLF EC All Pro Report Weigh Tronix 1000 Armstrong Drive Fairmont MN 56031 Towmotor ID Number Scale ID Number Present Time 12 16 31 Present Date 1 13 97 Pro Number 123456782 Pro Number Status Employee Number Last Transaction Time Last Transaction Date Actual Accumulated Weight Actual Number of Skids Estimated Accumulated Weight Estimated Number of Skids Pro Number 975257987 Pro Number Status Employee Number Last Transaction Time Last Transaction Date Actual Accumulated Weight Actual Number of Skids Estimated Accumulated Weight Estimated Number of Skids Pro Number 423284687 Pro Number Status Employee Number Last Transaction Time Last Transaction Date Actual Accumulated Weight Actual Number of Skids Estimated Accumulated Weight Estimated Number of Skids CAL WT ID CAL WT MEASURED WT CAL Date CAL Time 111 222 OPEN 456 12 02 14 1 13 97 2655 lb 2 40000 lb 4 CLOSED 456 1215720 1 13 97 7300 1b 2 50000 lb 5 OPEN 456 12 15 44 1 13 97 5310 lb 2 6000 lb 1 157845 500 LB 500 LB 1 13 97 12 01 29 18 Certified Lift Truck Scale with SimulCast Instrument User s Manual Error Messages Following are the error messages you may see while using the SimulCast
7. If your number is displayed press the ENTER key to accept If this is not your ID number either key in your ID number and press ENTER OR Scan the appropriate bar code for your ID number Press any key on the indicator to power up After the brief startup message it will ask for an employee ID number EMID as shown below EMID 123456782_ BKSP amp CHRT JPCHRI JADV gt The last ID number entered will be displayed The indicator will go to the weighing mode and the display will look like this 0 Certified Lift Truck Scale with SimulCast Instrument User s Manual 7 Entering the PRO and Estimated Weight 3 Scan in the PRO from the bar code OR Press the PRO F1 softkey and key in the PRO number If this is a new PRO number skip to step 5 If this is an active or previ ously entered PRO number the display will ask if you want to OPEN or CLOSE the PRO number Choose the correct response and continue OPEN CLOSE PRO 4 If you open a previous PRO number skip to step 9 If you close a PRO number repeat step three with a new PRO number 5 The following is displayed Enter Est Wt _ BKSPe Nes OT d 6 Enter the weight recorded on the shipping papers for the entire PRO and press the ENTER key The following is briefly displayed 0 PRO SKIDS EMID STORE MORE PRO Information Saved 8 Certified Lift Truck Scale with SimulCast Instrument Use
8. adjust the lift chain so the heel of the forks have 1 2 to 1 of clearance from the floor when the carriage is down and the mast is vertical 20 Certified Lift Truck Scale with SimulCast Instrument User s Manual Calculating New Lift Capacity You must have the ID plate on the lift truck updated stating the new lifting capacity and center of gravity information This requirement is per OSHA rules and regulations A calculation formula is provided below It is the customer s responsibility to contact their lift truck manufacturer distributor with this information to obtain the new ID plate The QTLTSC lift truck scale comes in ITA Class II 16 high 5 000 Ib and ITA Class III 20 high 5 000 and 10 000 Ib and Class IV 25 high 10 000 Ib and 16 000 Ib models Each class comes in several widths for cleat type carriages Measure the height and width of the lift truck carriage Select from the table below the appropriate width that best meets the dimensions of the lift truck carriage Use the weights dimensions and the following formula to calculate the net lifting capacity of your lift truck with a scale attached Refer to Figure 2 Net Capacity A B C D E F E G H A Truck basic capacity pounds B Inches from front wheel center line to fork face C Inches from fork face to truck rating point usually 24 D Weight of the scale in pounds E Inches from front wheel center line to carriage face F Inches from carriage f
9. fork lift has exceeded the angle used to calibrate the system Decrease angle of the fork lift or troubleshoot equipment for defects ADC Reset The analog to digital converter is not responding and or is in a reset state Cycle power verify A D board is plugged into main board or replace A D board Dead Display The unit may be in sleep mode Press any key to turn the unit on or hold the CLEAR key for five seconds then press any key to turn the unit on Certified Lift Truck Scale with SimulCast Instrument User s Manual 19 Daily Inspection Checklist For Lift Truck Scale Users L Check scale carriage for loose worn bent or broken components I Inspect forks for damage L Check locking pins on forks for proper function Q Inspect cables from the junction box to Weigh Bars for wear Q Inspect retractable cable for pinched rubbed stretched or damaged areas L Inspect power cable for nicks or cuts L Make sure power cable is routed out of harms way Fasten periodically to eliminate potential problems Q Tighten cable connections at indicator and summing box if necessary I Inspect cable clamps and cable ties to be sure all cable attachments are secure I Inspect digital indicator mounting bracket isolation mounts and hardware for loose or cracked parts L Check to make sure the junction box cover shielf is fastened Q Tighten bottom clamps on scale carriage if necessary Raise carriage and visually inspect L Check and
10. i AA R E e aa aE aa ee at he 18 Error Messages etc eee cadotrecresenreneptetedan seeiaxns seu ciety ested eatin rneeedeeespheeeaters 19 Daily Inspection Checklist for Lift Truck Scale Users cssssssssseeceeeeeeeeeeeeees 20 Pages are numbered consecutively beginning with the cover page Certified Lift Truck Scale with SimulCast Instrument User s Manual 3 Specifications Indicator Specifications Power input Display Operational keys Operational annunciators Time and date Angle compensation Standard interface ports Available options Operating environment Enclosure Dimensions Weight 10 90 volts DC 1 6 H x 3 2 W electroluminescent dot graphic display 160 x 80 dot layout Simultaneously displays 0 6 high readings of weight pro number accumu lated weight and accumulated number of skids Zero Tare Print Units Select Enter Escape Clear 0 9 decimal point and five soft keys labeled per selected operational routine All keys provide users with audio acknowledgment upon activation Displayed symbols indicate motion center of zero unit of measure and more Battery protected real time clock is included Detects and automatically compensates for pitch and or roll out of level weighing all with quick disconnects e infrared communication port e RS 232 bar code reader port e RS 232 printer output e scale carriage input power source input Bar code wand Infrared transceiver
11. returns to the normal weighing mode SETUP Softkey The next softkey is SETUP Follow these steps to complete the setup 1 Press the SETUP F3 key The following is displayed You have four 16 character ENTER ADD I _ lines to enter your company and location details ADD 1 ADD 4 PBKSPEPCHRT chrt PADV gt _ 2 Use the softkeys to scroll in up to 16 alphanumeric characters then press the ENTER key Repeat this step for address line 2 4 The following will be displayed TOWMOTOR ID _ BKSP lt CHRT JCHRL JADV gt 14 Certified Lift Truck Scale with SimulCast Instrument User s Manual 3 Key in the scale carriage serial number then press the ENTER key The following is displayed MIN TRANS LIMIT xxx_ BKSP amp ENEG Ot ooo do 4 Key in the maximum weight the scale must be below before a new transaction can be stored then Default for MIN TRANS LIMIT press the ENTER key The display returns to MORE key is 5 of capacity default display mode with EDIT CAL SETUP RESET and EXIT softkeys Certified Lift Truck Scale with SimulCast Instrument User s Manual 15 RESET Softkey The next softkey is RESET F4 This key gives you the option of clearing S all the Pro numbers and transactions from the system s memory All items under the SETUP key are retained as well as the accuracy test if one has been performed To clear the memory follow these steps 1 Press the RESET F4 key
12. 924 0010 38 0 2 75 5 50 53924 0036 40 0 2 75 5 50 53924 0051 42 0 2 75 5 50 53924 0077 44 0 2 75 5 50 53924 0093 46 0 2 75 5 50 53924 0119 48 0 2 75 5 50 53924 0135 50 0 2 75 5 50 53924 0150 52 0 2 75 5 50 53924 0176 54 0 2 75 5 50 53924 0192 56 0 2 75 5 50 Class IV 16 000 Ib Models 53924 0218 58 0 2 75 5 50 53924 0234 60 0 2 75 5 50 Scale P N Width Weight D DIM F DIM kK 53425 0014 38 0 1068 3 06 6 13 53425 0030 40 0 1092 3 06 6 13 53425 0055 42 0 1154 3 06 6 13 53425 0071 44 0 1178 3 06 6 13 53425 0097 46 0 1239 3 06 6 13 53425 0113 48 0 1263 3 06 6 13 53425 0139 50 0 1338 3 06 6 13 53425 0154 52 0 1362 3 06 6 13 53425 0170 54 0 1437 3 06 6 13 53425 0196 56 0 1461 3 06 6 13 53425 0212 58 0 1484 3 06 6 13 53425 0238 60 0 1592 3 06 6 13 53425 0253 62 0 1616 3 06 6 13 53425 0279 64 0 1639 3 06 6 13 53425 0295 66 0 1747 3 06 6 13 53425 0311 68 0 1771 3 06 6 13 53425 0337 70 0 1794 3 06 6 13 53425 0352 72 0 1812 3 06 6 13 22 Certified Lift Truck Scale with SimulCast Instrument User s Manual Net Capacity Ge gt _ gt K _ J Lift truck with no scale Lift truck with scale Figure 2 Recalculating Lift Truck Capacity Certified Lift Truck Scale with SimulCast Instrument User s Manual 23 24 Certifi
13. Avery Weigh Tronix Certified Lift Truck Scale with SimulCast Instrument User s Manual UNITED STATES This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CANADA This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications Le present appareil numerique n emet pas de bruits radioelectriques depassant les limites applicables aux appareils numeriques de la Class A prescrites dans le Reglement sur le brouillage radioelectrique que edicte par le ministere des Communications du Canada CAUTION Risk of electrical shock Do not remove cover No user service able parts inside Refer servicing to qualified service personnel Weigh Tronix reserves the right to change specifications at any time
14. ace to scale center of gravity CG G J K Inches from carriage face to rear face of load H Inches from fork face to new truck rating point J Thickness of fork K Thickness of scale L the height of the scale or the Vertical Center of Gravity VCG Class Il Class Ill 16 0 VCG Width Average loss in lifting capacity for a QuickTach lift truck scale is 12 to 14 Certified Lift Truck Scale with SimulCast Instrument User s Manual 21 Class II 5 000 Ib Models Scale P N Width Weight D DIM F DIM K 48196 0094 373 Ib 2 0 48196 0011 381 Ib 2 0 48196 0029 389 Ib 2 0 48196 0102 410 Ib 2 0 48196 0037 413 Ib 2 0 48196 0110 418 Ib 2 0 48196 0128 438 Ib 2 0 48196 0045 446 Ib 2 0 Class III 5 000 Ib Models Scale P N Width Weight D DIM F DIM k 51856 0016 36 0 520 2 00 4 00 51856 0024 37 0 2 00 4 00 51856 0032 2 00 4 00 51856 0057 2 00 4 00 51856 0073 2 00 4 00 51856 0099 2 00 4 00 51856 0115 2 00 4 00 Class III 10 000 Ib Models 51856 0131 2 00 4 00 Scale P N Width Weight D DIM F DIM K 51857 0031 2 75 5 50 51857 0056 j 2 75 5 50 51857 0072 2 75 5 50 51857 0106 i 2 75 5 50 51857 0114 2 75 5 50 51857 0155 2 75 5 50 51857 0197 2 75 5 50 51857 0239 2 75 5 50 Class IV 10 000 Ib Models Scale P N Width Weight D DIM FP DIM kK 53
15. ed Lift Truck Scale with SimulCast Instrument User s Manual Certified Lift Truck Scale with SimulCast Instrument User s Manual 25 26 Certified Lift Truck Scale with SimulCast Instrument User s Manual Weigh Bar is a registered trademark of Weigh Tronix Inc Avery Weigh Tronix A Avery Weigh Tronix USA 1000 Armstrong Dr Fairmont MN 56031 USA Tel 507 238 4461 Fax 507 238 4195 Email usinfo awtxglobal com www wtxweb com Avery Weigh Tronix UK Foundry Lane Smethwick West Midlands England B66 2LP Tel 44 0 8453 66 77 88 Fax 44 0 121 224 8183 Email info awtxglobal com www averyweigh tronix com
16. n your lift truck will have a front panel similar to the one shown in Figure 1 WEIGH TRONIX WI 130 SERIAL NO Simul KEYTOTURN ON CLASS jee ENTER Figure 1 WI 130 SimulCast front panel The F1 F5 keys correspond to the labels which appear above them in the display and are called soft keys because their function changes as the label changes The hard keys appear below the softkeys and their function is labeled on each key Certified Lift Truck Scale with SimulCast Instrument User s Manual DEA OTEO Overview Attention Press any key to turn the unit on Start Up and Entering Employee ID Press the ESCAPE key at any time to return to this mode Below is a brief overview of how you will use this system during a work shift Exceptions to these procedures and additional functions are covered in later sections e At start of shift enter employee ID number e Enter a PRO number in the unit using the bar code wand or keying it in on the numeric keypad of the SimulCast e Key in the weight listed on the shipping papers e Edit the number of skids if different than the default value of 1 e Weigh the skid or skids contained in that PRO e Close the PRO e Enter a new PRO and repeat until the shift ends or until you are required to download the stored information into the central computer The exact steps in doing the above procedures are shown below 1 2 Start the lift truck
17. play If it is not valid the display tell you so then return to the normal weighing mode New Skid _ BKSP amp NEG ff A 12 Certified Lift Truck Scale with SimulCast Instrument User s Manual CAL Softkey for Testing Accuracy You can press the ESCAPE key to abort 3 Key in the number of skids for the PRO number and press the ENTER key The following is briefly displayed PRO xxxxx ACC xxxx lb SKD x The display then changes to the normal weighing mode with the PRO you edited active Following these steps will produce an accuracy report which is downloaded when transmitting the Pro number data 1 Press the CAL F2 softkey The following is displayed ENTER TEST WT _ BKSP amp JCHRT CHR JADV gt 2 Key in the ID number of the test weight you are using and press the ENTER key The following is displayed TEST WT AMT 0_ BKSPe NEG OT Ad 3 Key in the test weight amount and press the ENTER key The following is displayed PLACE XXXXX ON THE SCALE AND PRESS ENTER XXXXX represents the ID number of the test weight Certified Lift Truck Scale with SimulCast Instrument User s Manual 13 4 Place the test weight on the scale and press the ENTER key The following is briefly displayed ACCURACY TEST ACCEPTED The following is briefly displayed CAL WT ID XXXXXX CAL WT xxxx LB MEASURED WT xxxx LB DATE TIME The display then
18. r s Manual then the following information is displayed Current weight PRO number Accumulated weight Accumulated skids and softkey labels An example of the display is shown below with a fictitious PRO number PRO 864478683 ACC 0 lb SKD 0 7 If you have just one skid to weigh skip to step 9 If you have more than one skid in this PRO press the SKIDS F2 softkey The following is displayed of Skids 1_ BKsPe NEG f TC 8 Key in the number of skids and press the ENTER key The previous screen is displayed Certified Lift Truck Scale with SimulCast Instrument User s Manual 9 Weighing Skids 9 Make sure the forks of the lift truck are off the ground and empty then press the ZERO key Lift the skid and when the weight reading is stable press the STORE F4 softkey The display will show the weight of When zeroing the scale or the skid the accumulated weight trying to store information the and the number of skids weighed as display will show ABORTED shown below if scale motion is detected an overload condition is detected or the angle detected is 4 8 2 D greater than the angle used to calibrate PRO 123456782 ACC 4825 1b SKD 1 10 Remove the skid zero the scale if necessary and repeat step 9 if The scale weight must fall there are more skids in the below a set weight before PRO When all the skids in the another transaction can be PRO have been sto
19. red scan or stored You set this weight key in the PRO The following is displayed under the SETUP key The display will remind you if you forget to allow the weight to go below this limit OPEN CLOSE PRO 11 Press the CLOSE F5 softkey The display confirms that the PRO is closed Closing the PRO indi cates that all skids associated with the PRO have been weighed The system is now ready to work on the next PRO Repeat steps 3 9 for each new PRO You can open multiple PRO s at one time Each time you open a PRO by scanning it or keying it in that PRO becomes the active PRO and any skid weighed will be assigned to that PRO To activate a different PRO scan or key it in To avoid confusion it is best to close a completed PRO before going to the next 10 Certified Lift Truck Scale with SimulCast Instrument User s Manual Downloading Information The information stored in the SimulCast can be downloaded at any time 1 Connect an interface cable between the SimulCast and peripheral or drive the fork lift to the area where the infrared receiver is located Line up the transmitter and receiver Press the PRINT key The following is briefly displayed Make your selection to Print A Report Then the following is displayed a 1 Closed Pro ose ro fe A 2 Open Pro 3 All Pro 2 Press the appropriate softkey for the report you want to download The following is briefl
20. y displayed Printing Report Please wait Then the following is displayed F1 NO F5 YES Clear 3 Press the YES softkey to clear the reports from memory or NO to save the reports The display returns to the weigh mode Certified Lift Truck Scale with SimulCast Instrument User s Manual 11 The MORE Key The MORE key F5 relabels the softkeys for several functions Below is the list of softkeys and their use Overview EDIT Softkey This key allows you to correct the recorded skid number when you pick up more than one skid at a time EDIT F1 CAL F2 SETUP F3 RESET F4 EXIT F5 Press this key to change the skid transaction count of an existing PRO number Press this key to test accuracy of the WI 130 system Press this key to customize information included in reports The address information also appears during the power up sequence The following items are available for you to personalize 4 lines for name and address Towmotor ID Min Trans Limit Press this key to erase all variables from memory Press this key to return to the normal weigh mode display Below are step by step instructions for each of these softkeys 1 Press the EDIT F1 softkey to change the skid counter for an existing PRO number The following is displayed BKSP amp ENEG ft A 2 Scan in a PRO or key one in and press the ENTER key If the PRO number is valid you will see the following dis

Download Pdf Manuals

image

Related Search

Related Contents

Manual do operador  Instruction manual for freestanding 50/50 fridge freezer  MODEL IHA-96 HEAT ON DEMAND® HEAT ACTIVATOR & BASE  AD-8123  s1220 フォトスキャンシステム  NOTICE RESULTZ - Takeda in Belgium  Royal Sovereign RBM-1200 User's Manual  Morphy Richards Cordless stainless steel kettle User's Manual  Manual LildbiWeb Español  USB Mini Spectrum Analyzer User Manual  