1. pressed transmitter s button is used to prolong timing of output set on in monostable mode only mode A In operation modes B and D the use of transmitter button one generates two pulses and the use of button two generates one pulse Transmitter Memory As each transmitter generates specific dynamic code receiver must learn and memorize every transmitter it operates with Therefore capacity of its memory is limited to 104 transmitters except in modes C amp D when limit is 20 transmitters Receiver Installation Receiver s place of installation should be dry and away from electromagnetic power lines radio transmitters metal screening and other devices that may cause interference and reduce operation range Receiver should be installed well above floor ground level It is recommended to test practical operating range of transmitter receiver set prior to firm installation Level of hand transmitter signals and unwanted radio interference signals can be checked using optional Elmes RFM indicator PROGRAMMING PROCEDURES IMPORTANT Wherever mentioned PRGX should be identified as PRG1 when programming receiver output or PRG2 when programming receiver output 2 Main LED low flashing green confirms properly programmed procedure while fast flashing red indicates programming error Programming procedure must be repeated 1 Learning transmitter to receiver s memory with allocation of selected button to any receiver output If by mistak
2. Models U2HS U2HSL U2HR receiver only EN This manual covers the following remote control products operation installation and programming Equipment Type Operating Range U2HS receiver U2HR 2 transmitters DWB100HT TWO RELAY OUTPUTS REMOTE CONTROL SETS WITH DYNAMIC CODE electronic U2HSL receiver U2HR 1 transmitter DW200HT U2HR U2HR receiver only eas 5 Above specified products differ in number and type of used hand transmitters All use the same receiver which features are described below Easy allocation of hand transmitter buttons to control any receiver output Receiver is provided with two on board programming switches PRGI for programming output one and PRG2 for programming output two Both programming switches allow learning any hand transmitter button to control respective output Moreover the same button can control other output of the receiver or two hand transmitter buttons can be learned to control one receiver output These features allow the following control possibilities examples e Some one button hand transmitters control operation of receiver output one while other one button transmitters control output two e Any button of multi button transmitter controls receiver output one while any other button of the same transmitter controls output two e Two buttons of the same transmitter control one receiver output one button sets the output on while other sets the output off e One transmitter button controls
3. e a button is allocated to control improper output deleting single transmitter procedure applies pt 2 below a Press receiver s PRGX switch for less than 2 seconds main LED lights green b Press shortly selected hand transmitter button once main LED changes to red c Press shortly the same hand transmitter button again 2 Deleting single transmitter in receiver memory This procedure applies also when changing allocation of transmitter buttons to receiver outputs Important condition transmitter to be deleted is available a Press and hold simultaneously switches PRG1 and PRG2 in receiver main LED initially lights green and after 2s changes to red Now release both switches b Press shortly any button of the hand transmitter to be deleted 3 Programming receiver output monostable operation mode pulse and output set on timing a Press and hold receiver s PRGX switch LED lights green and after two seconds changes to red Now release the switch b Press shortly the same PRGX Relay in the receiver sets on and LED lights green After required pulse time has lapsed press PRGX switch again Within 2s receiver s LED starts flashing green confirming end of the procedure 4 Programming receiver output bistable on off operation mode a Press and hold receiver s PRGX switch main LED lights green and after 2s changes to red Now release the switch b Press shortly PRGX switch three times with less than 2s intervals Programmed recei
4. er output then odd buttons 1 amp 3 always sets output on while even buttons sets the output off Number of remote control transmitters that can be used in this mode is limited to 20 KEELOQ Encoding System In the system newly encoded control signal is generated and sent each time transmitter button is pressed Receiver monitors code changes and responds to new code signals only Once received code will not be accepted second time This allows protection of radio transmission signals from deliberate code grabbing and unauthorized use Receiver Relay Output Receiver is equipped with galvanic isolated relay output with NO normally open and NC normally closed three wiring terminals one com mon The output switches over on received set on signal Details are shown on installation diagram included in this manual LED Indication Receiver is equipped with two LEDs Upper LED indicates power supply in red and switches to green on output 1 set on Bottom LED is off on output 2 set off and shines green on output 2 set on Signalling Output S Receiver features open collector type OC signalling output S for connecting to external acoustic siren or light strobe The output generates two pulses shorting to receiver s ground V on any relay output set ON and one pulse on relay output set OFF in 0 5s pulse rate Two pulses are e mail elmes elmes pl internet www elmes pl Elmes Elektronik 09 2013 All rights reserved generated also when
5. ffers from two earlier described by that it does not allow two outputs to be set on simultaneous ly If output one is on and transmitter button learned to output two is pressed then output one sets off Next pressed the same button sets output two on This mode is used for electric motors control e As above but remote control is performed with the use of single transmitter button only Subsequent use of the same transmitter button sets on output one sets the output off sets on output two sets the output off This mode is also used for electric motor control m G amp H e Pressed transmitter button sets output on Subsequent use of the same button does not change output status The output sets off when other button of the transmitter is pressed This mode B amp D is useful for secure switching on and off remote equipment not visible to operator e Pressed transmitter button sets receiver output on for as long as the button is pressed Released button sets receiver output off This remote control mode is frequently used by failed damaged car transporter operators mode C Table of relay outputs available operation modes JP1 On A Pressing transmitter button sets receiver s relay output on for B Each pressing of remote transmitter button sets receiver relay JP2 On programmed time period Next pressing of the button while output on and off alternately on off mode or one button sets to output is on prolongs set on time of the output on
6. only while other sets off only JP1 On C Receiver relay output is set on for as long as transmitter button is pressed and sets off after short delay on button release JP2 On button is not used output sets off after programmed time JP1 Off G As above except that two receiver outputs cannot be set on H As above except that two receiver outputs cannot be set on simultaneously function useful for motor control simultaneously function useful for motor control Output relay Monostable Mode pulse or Bistable Mode on off is programmed in steps 3 and 4 of programming procedures Delayed output set off reduces risk of unwanted interruptions in output set on continuity due to interferences caused e g electric motors Precise setting of this short delay timing is facilitated by programming 8 fold longer time delay of that needed Example to obtain 0 5s set off delay programmed delay of 4 5s delay must be made initially 0 5 x 8 4 These modes also allow single transmitter button control of two receiver outputs Subsequent use of transmitter button sets output one sets the output off sets output two on sets the output off etc To obtain that transmitter button must be learned to only one receiver output If transmitter button is learned to one receiver output then subsequent pressing of this button alternately set on and set off that output If two transmitter buttons 1 amp 2 or 3 amp 4 are learned to one receiv
7. r akustyczny Manufacturer ELMES ELEKTRONIK 54 611 Wroclaw Avicenny 2 PL IMPORTANT Output S must not be directly connected tel 48717845961 fax 48717845963 to pole of power supply see diagram above Low battery in transmitters is indicated either by its LED flashing DWB100HT or dimming and failing to light DW200HT Manufacturer s Limited Warranty This product carries two year manufacturer s warranty as from the date of purchase The warranty is limited to the replacement of faulty original parts or repair defects of improper manufacture Damage misuse or improper handling by the user or installer as well as any alterations in prod uct s hardware or software caused by unauthorized person violate warranty obligations and all due repair costs will be charged Elmes Electronic shall not be liable for any personal or material damage or loss resulting from any of its products direct indirect or partial use or failure to operate properly e mail elmes elmes pl internet www elmes pl Elmes Elektronik 09 2013 All rights reserved
8. two receiver outputs simultaneously e g controlling two equipment units with galvanic separation Remark full flexibility of allocating any hand transmitter buttons to control any receiver outputs refers to use of Elmes transmitters with to 4 control buttons and multi channel hand transmitter STX In the case of transmitters CH8H and CH32H certain limitations apply buttons of two adjacent control channel banks cannot be learned to the same receiver e g buttons from banks amp 2 or 3 amp 4 etc Receiver outputs operation modes Receiver outputs can operate in one of many modes selected by jumpers JP1 and JP2 and individually programmed to each output monostable pulse or bistable on off timing modes see pt 3 amp 4 of programming procedures and table below These allow range of solutions for various remote control applications such as examples e Pressed transmitter button sets receiver output on for programmed time Next pressed while in output set on state prolongs set on time mode A in Table below e Pressed transmitter button sets receiver output permanent on Next pressed sets output off modes B D amp F e Pressed transmitter button sets receiver output on for programmed time Next pressed while in output set on state sets output off m E e Pressed transmitter button sets receiver output permanent on mode H or for programmed time mode G Next pressed while in output set on state sets output off This mode di
9. ver output sets on and off followed by main LED flashing green confirming end of the procedure 5 Deleting all transmitters in receiver memory Press and hold depressed simultaneously PRG1 and PRG2 for more than 8 seconds till main LED flashes green Now release the switch All transmitters in receiver memory are deleted while programmed operation modes of outputs remain unchanged Advice 1 Procedures 2 3 and can be performed with the use of transmitter learned to the receiver memory Advice 2 Time for performing procedures 1 and 2 above is limited to 30 seconds If the procedures are not completed within this time period receiver exits programming mode and error is indicated SPECIFICATION CENEO es a ee ee ee DWB100HT transmitter radiated power lt 5mW battery 12V 23A DW200HT transmitter radiated power lt 10mW battery 9V 6F22 Receiver dynamic code system KEELOQ of Microchip Corp USA transmitter memory capacity 104 limited to 20 modes C amp D superhet receiver module with sensitivity 106 dBm power supply 11 17 VDC current consumption 20 mA 20 mA for each relay set on Operating temperature range from 20 to 55 C monostable output timing from 0 25s up to 4 hours bistable output mode on off signal output S 1A 60V max OC type sabotage alarm terminals NC type closed box external dimensions h w I 24 46 73 mm 22222220222 external buzzer sygnalizato

Download Pdf Manuals

image

Related Search

Related Contents

Télécharger (2.8 Mo)  Post-partum!:Les Héroïnes Mode d`emploi Niveau OMS  Aristel Networks Aristel Networks EH64 Hotel Motel Call Accounting  NuTone WS230WW Installation Guide  phoenix thermal printer installation & operation manual  Boletín informativo anual 2003/2004 Vanas Dive  MODEL NO. : TB212  Generic backplane  Samsung Varmluftsovn 42 liter FQ159UST Brugervejledning  Imprimir Fiche_RO_ADD PEINT  