1. adjust the time before device auto power down when it is unused Reset icon force a factory reset of the SDT200 device Note that this does not erase saved measurements Escape icon to get back to the main menu In the main menu to get back to the measurements screen press the F1 button e To modify the parameters of the selected setting o Use the Up and Down arrow buttons to switch form one field to another o Use the Left and Right arrow buttons to modify the value of the selected field o Use the Enter button to save the changes and return to the previous menu o Use the F1 button to go back to the previous menu without saving the changes DIAC pale e From the Measurements screen press the Enter Button to access the Main Menu e Use the arrow buttons to highlight the Device Info cont 4 e Press the Enter Button to display device information o The version of your instrument screen 1 o lts calibration date screen 2 o The serial number of the battery and its remaining capacity screen 4 o The device and PCB serial numbers the firmware version screen 5 e Use the Up and down arrow buttons to switch between the different screens Push the F1 button to go back to the main menu and push once again the F7 button to go back to the measurements screen DC R179 SDT200 MA 001 EN 01 11 SDT200 technical specifications Technical specifications for all SDT200 versions Ex For SDT200 ATEX version specific tec
2. might be using a You can increase the autonomy by adjusting the Auto Power Down and the time before switching off the backlight Related link Battery charger DC R179 SDT200 MA 001 EN 01 5 urning on amp turning off the SDT200 To turn on Press the Power button on the bottom right of the keypad The status LED will shine dark blue Then a few seconds later you will see on the screen the SDT logo and the message loading If you do not see this display your battery might be flat To turn off Push the Power button on the bottom right of the keypad You will see the following display Status LED Enter bution Confirm the device shut down by pressing the Enter button Power button Connector for ext sensor The SDT200 is equipped with a LEMO connector used to plug external sensors It is a commonly used industrial connector considered for its reliability and robustness It have a sprung loaded knurled barrel and mechanical polarisation to go only in one way round To plug a LEMO connector e Line up the red dot on the plug with the red mark on the connector e Insert the plug into the connector without any rotating movement When an external sensor is connected to the SDT200 it is automatically selected Howerver you can switch between available sensors using the F1 button To unplug the LEMO connector e Move up towards the cable the ring located on the bottom of the plug e Only pul
3. 9 SDT200 MA 001 EN 01 4 Charging the battery The SDT200 uses an internal NiMH battery The battery charger outlet will connect to a socket on the bottom side of the SDT200 Ex aN Charging the battery of the SDT200 ATEX version must exclusively be performed outside potentially pa explosive environments Due to the typical self discharge rate of NiMH batteries it is recommended to charge the SDT200 battery at least every 3 months even if it is not used It is recommended not to store the SDT200 with an uncharged battery for more than a few weeks This would significantly reduce the battery life span A Only use the charger provided by SDT The charging time will typically be 6 hours When the LED of the charger is continuously green the SDT200 battery is completely charged Like most batteries these days leaving the SDT200 charging after the charger says it is charged does not hurt the battery in fact it very slowly tops the charge up a little more g7 You can charge the SDT200 switched off You can also trickle charge the SDT200 switched on so you can be using it to load and unload data for example and charge it at the same time Battery loader connector SDT200 bottom side SDT Universal charger for SDT200 A fully charged battery will give you about 8 hours of continuous use This will vary of course depending upon your need to use the backlight and the power drain of certain external sensors that you
4. IEC 60079 0 60079 11 and 60079 26 Check room temperature for use of the SDT200 ATEX version in potentially explosive DANGEROUS AREA gt environments The max permissible room temperature Is e 15 C to 50 C T3 Loe 20 4 Co 96nF e 15 C to 60 C T2 ij 88 7mA Lo imH SSeP 11 ATEXO0EX The SDT200 ATEX version has the following marking on the rear side 415 Bd Humanit B 1180 Brisesle wa SN S0Syyoon Ex Electrical specification for non SDT sensors used with the SDT200 ATEX version Check electrical compatibility of non SDT sensors for use in potentially explosive environments before connecting them to the SDT200 ATEX version Max outer voltage Vo 20 4V Max outer current intensity Ig 68 7mA Max outer effective capacitance Co 96nF Max outer effective inductance Lo 1mH DC R179 SDT200 MA 001 EN 01 13 Built in ultrasound sensor Ultrasound sensor Function amp type Open type ultrasonic sensor Bandwidth 2 kHz at 6 dB Central Frequency 40 kHz 1 kHz Sensitivity 65 dB V ubar at 40 kHz Total beam angle 55 typical at 6 dB Built in pyrometer Built in pyrometer Field of view Sensor type Infrared temperature sensor sensor temperature 40 125 C T t librati e eh ene object temperature 10 380 C Measurement resolution 0 1 C o For measured temperature between 70 C and 40 C 2 C o For measured temperature between 40 C and 0 C 1 C Temperat
5. SDT700 Operating instructions You can download the latest version of this manual by visiting the SDT International website www sdt eu SDT International sa nv Bd de l Humanit 415 B 1190 Brussels Belgium Tel 32 0 2 332 32 25 Fax 32 0 2 376 27 07 email info sdt be website www sdt eu DC R179 SDT200 MA 001 EN 01 1 able of contents Safety precautions for the SDT200 ATEX version Overview Getting started Charging the battery Turning on amp off the SDT200 Plug amp unplug a sensor Functions reference guide Taking and storing an ultrasonic measurement Taking and storing a temperature measurement Review measurements stored in the SDT200 Download data to pc Erasing SDT200 memory Updating the SDT200 firmware Changing device settings Device info Technical specifications SDT200 receiver Built in ultrasound sensor Built in pyrometer Battery charger Miscellaneous Declaration of conformity Warranty and responsability Copyright DC R179 SDT200 MA 001 EN 01 Safety precautions for the SDT200 ATEX version Please read carefully the safety precautions before using the SDT200 ATEX version ina potentially explosive environment e Make sure your SDT200A protection class is suited regarding the environment it will be used e Under no circumstances do not attempt to service or replace SDT200 ATEX version components In case of malfunction contact SDT International or SDT local rep
6. fied settings Note that the preferred configuration is reloaded at startup of the SDT200 Getting data Press the M button e To freeze RMS and Max RMS values when the acquisition time is set to 0 second e To start the acquisition when the acquisition time is set to 1 Second or more At the end of the acquisition time a screen detailing RMS Max RMS Peak and Crest factor values is displayed Press the F3 button or the Store button to save the data or the F1 button to come back to the measurement screen without saving the data Then choose the desired memory location using the Up and Down arrow buttons and confirm by pressing the Enter button DC R179 SDT200 MA 001 EN 01 7 aking and storing a temperature measurement g 7 This feature is optional Select the built in pyrometer by highlighting the T in the upper left corner of the display with the F7 button Activate or deactivate the laser pointer using the F2 button Measurement settings Press the F3 button to enter the Measurement Settings menu Fi button F2 button F3 button Store button Lett night up and down arrow buttons You can e Adjust the emissivity coefficient from 1 to 0 01 e Switch between Celsius Fahrenheit and Kelvin physical units Enter button To modify the parameters of the selected setting e Use the Up and Down arrow buttons to switch form one field to another e Use the Left and Right arrow buttons to modify the
7. hnical specifications please see next page Function Display Keyboard Built in sensors External sensors Data Logger Communication Software for transferring data to PC Battery pack Auto power down Operating temperature Housing Weight Dimensions Headphones Multifunction detector Graphic LCD with backlighting 128 x 64 12 function keys Ultrasonic sensor Pyrometer according to the version Through specific connector Lemo 7 pin connector 20 Measurement Nodes measurement points Total 4000 Measurements measurements data USB interface DataDump Application Rechargeable battery type 8 cell 4 8 V NiMH Nickel Metal Hydride Nominal capacity 4 4 Ah Life span 500 to 1 000 charge discharge cycles Autonomy 6 to 7 hours Protections short circuit reverse polarity and temperature protected Auto power down after preset time 15 C to 60 C 14 F to 140 F non condensing Extruded aluminium 770 g 27 oz 226 x 90 x 40 mm 8 90 x 3 54 x 1 57 inches L x W x H noise isolating NRR 25 dB tested in an accredited NVLAP laboratory for optimum performance this battery pack is equipped with an electronic management system includes digital serial number capacity and temperature management DC R179 SDT200 MA 001 EN 01 12 Ex Specific technical specifications for the SDT200 ATEX version The SDT200 ATEX version is certified ATEX II 1 G Ex ia IIC T3 T2 Ga according to
8. l the connector without any rotation ea Please never pull on the cable itself DC R179 SDT200 MA 001 EN 01 6 aking and storing an ultrasonic measurement Select the desired ultrasonic sensor using the F1 button if necessary Set up amplification using Up and Down arrow buttons till the up and down amplification adjustment indicators disappear Activate or deactivate the laser pointer using the F2 button Amplification level Measurement settings Adjust amplification indicatar Press the F3 button to enter the measurement settings menu F1 button F2 Button Fa button Adjust the acquisition time using Up and Down arrowbuttons If the acquisition time is set to 0 second the RMS Max RMS Peak and Crest Factor are refreshed every 250 milliseconds This mode enables the operator to take data on the fly Store button Left right up and down arrow Buttons If the acquisition time is set at 1 second or more the RMS Peak and Crest Enter bution Factor will be calculated over the complete acquisition time The Max RMS will be the highest sub RMS reached over the complete acquisition time Each sub RMS is calculated during 250 milliseconds The maximum acquisition time is 10 seconds Use the F7 button to save the settings as preferred configuration Use the F2 button to load the settings associated to the preferred configuration Use the F3 button to go back to the ultrasound measurement screen using the modi
9. le one time the add on by opening the menu File Preferences and clicking the button Add export IE to Excel registry rule The report is automatically stored on your computer using the format report dd mm yy xml By default the path is C Users Public Documents SDT SDT270DataDump Reports 504 or 505xxxxxx or 505xxxxxx which is the serial number of your SDT200 device Other SDT DataDump functions Erasing the SDT200 memory Verify the USB radio button is ticked then click on Device menu and Delete all device data You can also use the keyboard shortcut CTRL U Updating the SDT200 firmware Oum bil Select the menu Device Update Firmware On the Device update window tick the radio button USB and then click Check for updates Note that this requires an internet Reset connection Updating the SDT200 firmware is possible during the warranty period DC R179 SDT200 MA 001 EN 01 10 e To access the Main menu press the Enter button e Use the arrow buttons to highlight the Settings cont e Press the Enter button to access the Settings menu e Use the arrow buttons to select the desired icon and the Enter button to select the desired setting Language icon change device interface language English Nederlands Frangais Deutsch taliano or Espanol Date and time icon set date time and their format LCD icon adjust the screen contrast and the operating time of the backlight Auto power down icon
10. product is altered in any way if an unauthorized party attempts repair or the unit is opened without written authorization of SDT International In the event of a defect contact your local SDT representative or SDT International Responsibility limits Neither the company SDT International nor any related company will in any circumstances be liable for any damages including without limitation damages for loss of business business interruption loss of information defect of the SDT200 unit or its accessories bodily harm loss of time financial or material loss or any other indirect or consequential loss arising out of the use or inability to use this product even when it has been warned of possible damages Copyright 2012 SDT International n v s a All rights reserved No one is permitted to reproduce or duplicate in any form the whole or part of this document without the written permission of SDT International n v s a The information herein is believed to be accurate to the best of our knowledge Due to continued research and development specifications of this product can change without prior notice DC R179 SDT200 MA 001 EN 01 16
11. red according to the recording time stamp Select a time stamp by using the Arrow Buttons then and press the Enter button to visualize the data Press the F1 button to come back to the list of recording timestamps To delete a recording select its timestamp using the Up and down arrow buttons and press the F2 button To come back to the measurement screen press a few times the F1 button DC R179 SDT200 MA 001 EN 01 9 Download data to PC using SDT DataDump gt Note be sure that the SDT200 USB driver and SDT DataDump software are correctly installed on your computer before continuing this section Do not connect your SDT200 device to the computer before the SDT200 USB driver is installed Start the SDT DataDump application on your computer The SDT DataDump window appears Verify the USB radio button is ticked then click on Collect The report is generated and opened via your web browser Each measurement includes the sensor used the time stamp RMS Peak and Crest Factor values You are able to export data to MS Excel by a right click on the Internet Explorer web browser interface Select Al Al Accelerators Bd de L Homanite 415 Create Shortcut 1190 Brussels ine _ SDT2Z70 270090056 report generated on 11 02 1 03 Nodel Sensor Internal US Ajouter un fichier POF existant Convertir au format Adobe POF Export bo Micromart Excel ea Note You must first enab
12. resentative e Maintenance must always be performed outside potentially explosive environments e Battery charge must exclusively be performed outside potentially explosive environments A e FUBATTR270 02 is the only authorized power source for SDT200 ATEX version e The max permissible room temperature is o 15 C to 50 C for T3 o 15 C to 60 C for T2 e Potential danger of static electricity for the display Avoid electrostatic charge o Avoid friction o No dry cleaning e Do not use USB connectivity in dangerous area e Do not use SDT carrying case in dangerous area Related links Technical specifications of SDT200 ATEX version DC R179 SDT200 MA 001 EN 01 3 The main side Amplification level Adjust amplification indicatar F1 button F2 button F3 button Status LED Store button Left right up and down arrow butions Enter button Backlight button Power button The back side Marking Serial Number CE marking The rear side of the SDT200 ATEX version has a specific ATEX marking Ultrasound sensor The sensor side Connector for ext sensor Built in pyrometer Activation of this functionality is optional Laser pointer Built in thermometer The bottom side Reset button Insert a needle to make a reset Reset causes a restart of the device but the data stored are not deleted Battery loader connector Mini USB connector Reset Headphones connector DC R17
13. umanit 415 B 1190 BRUSSELS BELGIUM declares that SDT200 Multifunction Detector making the object of this declaration is built in conformity with the applicable European Directives e Electrical equipment for measurement IEC EN 61010 1 e EMC Directive 2004 108 CE e Low voltage Directive 2006 95 CE The equipment hence displays the EC logo of being compliant to the current EC regulations To be able to operate by state of the art rules as stipulated in the directive it has been designed by the following rules e The SDT200 does not radiate electromagnetic waves EMC e The SDT200 is immunized against external electromagnetic radiation EMI e The SDT200 is protected against electrostatic discharges ESD Note the owner is obliged to preserve the present users manual with the obligation to pass it on to future users or been resold to another user Brussels January 2012 The Manager Warranty and responsibility limits Warranty SDT International guarantees the SDT200 unit against manufacturing faults for a period of 2 two years with the exception of the battery and accessories charger headphones sensors etc these are guaranteed for a period of 6 six months The warranty covers all material supplied and implies the free replacement of all parts that contain a manufacturing fault Warranty does not include shipping handling and importation The warranty is void if misused or accident damages the product if the
14. ure precision for ambiant o For measured temperature between 0 C and 60 C 0 5 C temperature between 0 and 50 C For measured temperature between 60 C and 120 C 1 C for emissivity 1 o For measured temperature between 120 C and 180 C 2 C o For measured temperature between 180 C and 240 C 3 C o For measured temperature between 240 C and 380 4 C Field of view at 50 of attenuation 10 DC R179 SDT200 MA 001 EN 01 14 Battery charger Charger type specific for SDT200NiMH battery pack Power supply 110 VAC to 230 VAC 15 10 50 60 Hz Output voltage 4 0 or 8 5 V DC depends on operating mode Power 7 9 W Protection temperature protected limit set at 60 C 140 F Green LED is continuously lit battery is fully charged Green LED flashes evenly normal charge One red flash every 5 seconds Battery Voltage error Two red flashes every 5 seconds Over temperature error Three red flashes every 5 seconds Timeout full charge Four red flashes every 5 seconds Timeout Rapid charging Five red flashes every 5 seconds Timeout Activate charging Six red flashes every 5 seconds 1 Wire communication error Status indicator Isolation double isolation Weight 300 grams 10 6 ounces Housing PPE IEC 60950 CB certificate Conformity conform with CA and US national conditions DC R179 SDT200 MA 001 EN 01 15 Declaration of conformity SDT International n v s a Boulevard de H
15. value of the selected field e Use the Enter button to save the changes and return to the previous menu Use the F1 button to save the settings as preferred configuration Use the F2 button to load the settings associated to the preferred configuration Use the F3 button to go back to the ultrasound measurement screen using the modified settings Note that the preferred configuration is reloaded at startup of the SDT200 Freeze measurement Press the M button to freeze the measurement Store measurement Press the Store button to save the measurement Then highlight the chosen memory location using the Up and Down arrow buttons and confirm by pressing the Enter button or the F1 button to cancel measurement storage DC R179 SDT200 MA 001 EN 01 Review measurements stored in the SDT200 From the Measurement screen press the Enter key to access the Main Menu Use the arrow buttons to highlight the Node Tree icon ie Press the Enter button to display the list of memory locations g gt Note the sign placed before a memory location means it contains recorded measurements Select the desired memory location using Up and Down arrow buttons Expand the memory location using the Right arrow button The saved measurements are filtered regarding the sensor used Select the desired sensor using Up and down arrow buttons Display the list of saved measurements by using the Right arrow button The data are filte
Download Pdf Manuals
Related Search
Related Contents
Artikelarchiv 2008, 1. Teil - SPD-NET-SH ハイドロパワーキューブ6灯式 (昇降式投光機) Wheelchair Lift Ricon Model F9A Mirage 取韓軍明書本警表示玉琴亭諸實意青き墓誌た夢界状請で量証期堂内尾 Craftsman 107.27768 Lawn Mower User Manual NGS Black Artica Manuel d`instructions du KIT de mise à niveau I Operation Manual 09/2003 Glacier Bay N2420-BLK Instructions / Assembly Canon KJ10EX4.5B IRSE User's Manual Copyright © All rights reserved.