1. 14 Mars Road Lane Cove NSW 2066 Australia Tel 61 2 9428 6555 Fax 61 2 9428 6352 Cochlear Americas 400 Inverness Parkway Suite 400 Englewood CO 80112 USA Tel 1 303 790 9010 Fax 303 792 9025 Cochlear GmbH Karl Wiechert Allee 76A D 30625 Hannover Germany Tel 49 511 542 770 Fax 49 511 542 7770 Cochlear Europe Ltd 22 24 Worple Road Wimbledon London SW19 4DD United Kingdom Tel 44 20 8879 4900 Fax 44 20 8946 9066 Nihon Cochlear Co Ltd Ochanomizu Motomachi Bldg 2 3 7 Hongo Bunkyo Ku Tokyo 13 0033 Japan Tel 81 3 3817 0241 Fax 81 3 3817 0245 www cochlear com Cochlear AG Margarethenstrasse 47 CH 4053 Basel Switzerland Tel 41 61 205 0404 Fax 41 61 205 0405 Cochlear HK Ltd 21F Shun Ho Tower 24 30 Ice House Street Central Hong Kong Tel 852 2530 5773 Fax 852 2530 5183 Nucleus is a registered trademark of Cochlear Limited ESPrit is a trademark of Cochlear Limited PRINTED IN AUSTRALIA N95515F ISSI
2. eWhen using new High Power Zinc Air batteries be sure to wait for one minute after removing the protective tabs before placing them into the ESPrit 3G eChange your batteries High Power Zinc Air batteries may cease to work in very cold or extremely humid conditions In these instances it is recommended that you use Silver Oxide batteries Check your transmitting coil and cable s operation eThe transmitting coil is correctly positioned over your implant eThe transmitting coil is not damaged eThe cable is not bent twisted worn or broken eThe cable plug is secure in the socket of your ESPrit 3G If there is no signal replace the transmitting coil and cable and check if you can hear any sound If there is still no signal test using the Signal Check Check your microphone If the output signal from the microphone diminishes significantly 1 Use the microphone puffer to dry any moisture 2 Attach and use the lapel microphone If you can hear sound using your lapel microphone your ESPrit 3G microphone 1s faulty As a temporary measure you can continue to use the lapel microphone until you are able to have your ESPrit 3G microphone repaired 3 Using the monitor earphones have a hearing person e g friend parent or caregiver check the microphone signal sound output For more information refer to your ESPrit 3G User Manual on any of the above G Cochlear Cochlear Ltd ABN 96 002 618 073
3. The ESPrit 3G Speech Processor The ESPrit 3G is a small lightweight behind the ear speech processor for use with Nucleus cochlear implants Nucleus COCHLEAR IMPLANT SYSTEMS ESPrit 3G Quick Reference Guide Transmitting coil Top controls Microphone ports Pe Earhook O A Transmitting cable gt N I lt Battery cover Base controls ImportantTips eIf your ESPrit 3G shuts down it is most likely time to change the batteries Nucleus eChange all batteries at the same ESPrit time The ESPrit 3G uses three High Power 675 Zinc Air batteries a In humid and cold conditions Silver Oxide S76 batteries may be more reliable When changing High Power Zinc Air batteries wait at least one minute after removing protective tabs before inserting them into the ESPrit 3G eFor normal listening situations have the mode switch on M The mode switch is located at the base of the ESPrit 3G eTo use the in built telecoil move the mode switch at the base to the T position When using the telecoil with a phone experiment with the position of the phone s earpiece to find the best reception eIf your earhook is uncomfortable try either the optional soft cover or the earmould compatible earhook eAlways store your ESPrit 3G in the storage case provided The processor should be turned OFF and placed with an activated drying capsule in the closed case eIf the accessor
4. ies are not working properly switch the ESPrit 3G OFF then ON Troubleshooting If there is no sound sound volume is low background noise is too high or the sound is intermittent there may be a number of reasons including Your ESPrit 3G needs re setting switch OFF momentarily and then ON again Your volume or sensitivity control needs adjusting eThe mode setting needs changing eThe battery contacts need cleaning eOne or more batteries are flat dead depleted eThe wrong battery type is being used eThe microphone is faulty or its ports are blocked The transmitting coil and cable set is faulty eThe transmitting coil and cable are not connected eYour ESPrit 3G has a fault Steps to Identify the Fault Follow the steps below to identify where the fault may be After each step check to see if you can hear sound If you still hear no sound after taking the following actions contact your clinician implant centre or your nearest Cochlear office Check the switches and controls Switch the ESPrit 3G OFF for about three seconds and then ON again top control O P1 P2 eAdjust the volume or sensitivity control top control numbers eAdjust the mode switch to the correct setting for your current use base control Check your batteries operation eClean the battery contacts using the cleaning brush provided Wipe the battery contacts with a soft clean cloth to remove any moisture

Download Pdf Manuals

image

Related Search

Related Contents

Anleitung - Voelkner  No. 58-06100 Bedienungsanleitung Instruction Manual Mode d`emploi  da Vinci 1.0 User Manual    ECM Lite - Electrostatica  FR - Hilti  La Eiltration Lente sur Sable  C Program Interface - Fujitsu manual server  

Copyright © All rights reserved.
Failed to retrieve file