Product User Manual MC12
Contents
1. active even during the Pause Functioning of the Courtesy light The 230 Vac output will be activated for 3 minutes each time that an ascent command is given 3 T MOT Programming the motor operating time max 4 minutes The control unit is factory supplied with a working time motor predef ned equal to 30 sec If a reprogramming of the motor operating time is needed it must be carried out through the closed frame in the following manner use the SEL button to navigate to the T MOT LED when f ashing then continuously press the SET button The rolling shutter will start the opening When you have reached the required height release the SET button and at the same time the motor time storage will be completed and the T MOT LED will remain lit and f xed If you want an inf nite motor time use the SEL button to navigate to the T MOT LED when f ashing and press the SET button for less than 1 second At the same time the LED will shut off and the operation will be completed It is advisable to memorise a time that is a few seconds longer after the frame has reached the end 4 T PAUSE Automatic closing time programming max 4 minutes The manufacturer furnishes the control unit with an automatic closure pause time equal to 15 sec If a reprogramming of the automatic closing time is needed it must be carried out through the closed frame in the following manner use the SEL button to navigate to the T PAUSE LED when f ashing Then
2. ELECTRONIC PANEL MC12 MC12C Mono phase electronic control unit for the automation of sliding doors and rolling shutters with incorporated radio receiver TECHNICAL DATA 230 Vac 50 60Hz 2 5W max 230 Vac 500 W max Power supply Flashing light output Motor outputs 230 Vac 500 W max Aux power supply output 24 Vac 1 5 W max Button and safety device input 24 Vdc Working temperature 7 10 55 C Radio receiver see model Op transmitters 12 18 Bit or Rolling Code Max TX codes in memory 7 UP 7 DOWN or 7 P P Dimension of panel 99x50x28mm Container ABS V 0 IP44 internal use T PAUSA T MOT LAMP CORT CODE elsleleielele elslelelelele propa 0 Od i pH ri ANTENNA ISO ax 230V 230V 24VAC CONNECTIONS OF THE TERMINAL BOARD CN1 1 230 Vac input Phase 2 230 Vac input Neutral 3 230 Vac f ash input Neutral 4 230 Vac fash input Phase 5 Opening motor output 6 Common motor output 7 Closing motor output CN2 1 24 Vac 1 5 W service power supply output 2 24 Vac 1 5 W service power supply output 3 Open close push button control input NA 4 Common GND input 5 Safety device input NC 6 Aerial earth input 7 Aerial hot pole input LED Reference OPERATING FEATURES Step by step operation By using both the radiocontrol LED CODE on and the low voltage push button panel PUL to activate the f
3. and 7 mm The internal conductors wires must have a nominal section of 0 75mm Ifa raceway is not used use HO5RR F cables Fix a warning sign near the place of installation conform with ISO 3864 with minimum height of 60 mm Use safety devices capable of monitoring the status of their connection to the electrical control unit When installation is complete carry out all the controls prescribed by EN 12453 EN 12445 to be sure that the closing complies with the provisions For a correct functioning of the radio receiver if using one or more control units the installation at a minimum distance of at least 3 metres one from the other is recommended IMPORTANT FOR THE INSTALLER The device must never be used by children or persons with reduced physical psychological abilities unless supervised or trained on the functioning and the use modalities Do not allow children to play with the device and keep the radiocontrols away from their reach Ensure there is no one immediately near by until the door is not fully open or closed ATTENTION keep this instruction manual and respect the important safety prescriptions contained herein The non compliance with the prescriptions may cause damages and serious accidents Frequently examine the plant to detect any signs of damaging Do not use the device if a repair intervention is All operations that require the opening of the casing cables connection programming etc must
4. astening the following functioning is obtained the frst command impulse activates the opening mechanism until time expiry of the timing motor The second command impulse closes the frame If an impulse is sent before time has expired the control unit will stops the motion A further input implements the re starting of the motion in the opposite direction Automatic closing The control unit closes the frame automatically without sending other commands Choice of this operating mode is described under the instruction for setting the Pause time Safety device The control unit allows for the connection and control of Photocells Tyre sensors NC Command from these devices are ignored during opening whilst the gate is closing they will reverse the direction of movement Important If not used the terminals must be jumped PROGRAMMING SEL button selects the type of function to be memorised the selection is indicated by a f ashing LED By repeatedly pressing the button it is possible to choose the desired function The selection will remain active for 10 seconds indicated by a f ashing LED If no other operations are executed during this period the control board will return to its previous state SET button programs the information relative the type of function previously selected with the SEL button LED On Code activated Courtesy Light Programmed dela With automatic close LED Off No code Flashing Unlimited tim
5. be carried out by expert personnel during installation For any further operation which requires the casing to be re opened re programming repair or installation amendments contact the after sales assistance STATEUROP declares that the products Electronic control unit MC12 MC12C comply with the specifications of the R amp TTE 99 5 EC EMC 2004 108 EC and LVD 2006 95 EC Directives CE Rev 1 0 on 07 11 2011
6. ing No automatic close 1 CODE 2 LAMP CORT 3 T MOT 4 T PAUSE 1 CODE Radiocontrol programming Operation with 1 or 2 codes of the radiocontrol During the programming procedure it is possible to save 1 or 2 radiocontrol codes One code allows for cyclical operation Up Down two codes allow to obtain two distinct controls the f rst for ascent and the second for descent Programming The transmission code is programmed in the following manner press the SEL button LED CODE starts f ashing At the same time send the f rst code selected with the desired radiocontrol and LED CODE will start f ashing quickly send the second code to be saved LED CODE will remain on and the programming is complete If the second code is not sent within 10 seconds the control unit will exit the programming phase and select the function with only one code of the radiocontrol In case all 7 available codes have been memorised by repeating the programming operation all 4 LEDs indicators will start to f ash very fast indicating that further memorising is not possible Programming the transmission code remotely This procedure allows to program the transmission code remotely without using the SEL button on the unit itself but remotely following the operation To program a transmission code remotely proceed as follows send the code of a previously saved radiocontrol code continuously for more than 10 seconds at the same time the cont
7. press and hold down the SET button for a period equal to the desired pause interval between closing and opening operations At expiration of the desired time release the SET button At the same time the memorisation of automatic closing time will be determined and the T PAUSE LED will remain lit If you do not want automatic closing take position on the f ashing of the T PAUSE LED Then press the SET button for less than a second At the same time the LED will shut off and the operation will be concluded RESET To reset the default conf guration of the control unit press the SEL and SET buttons simultaneously all RED indicator LEDs will switch on and then off again immediately IMPORTANT FOR THE INSTALLER The control unit was designed to be assembled together with other components motor shutter or gate safety devices to constitute a finished product machine in compliance with Machinery Directives The safety of the final installation and the compliance with all prescribed Standards is the responsibility of the person who assembles the various parts to construct a total closing It is also advised to comply with the following recommendations Before automating the frame check that it is in good conditions in compliance with the Machinery Directive and with EN 12604 Wiring of the various electrical components outside of the control unit must be carried out in compliance with that prescribed in Standard EN 60204 1 and i
8. rol unit enters the programming mode as described above Enabling the programming of a transmission code remotely The control unit is supplied by the manufacturer with remote programming of a transmission code not enabled to enable the function proceed as follows connect the control unit to a 230Vac power supply by pressing and holding the SEL button All the indicator LEDs will turn on and the programming is complete To disable the function enabled previously repeat the operation or conduct the RESET procedure Deletion Cancellation of all memorised codes is carried out in the following manner press the SEL button and LED CODE will start to fash Then press the SET button The procedure is now complete and LED CODE will stop f ashing 2 LAMP CORT Selection of the fashing light or the courtesy light The control unit has a 230 Vac 500 W output for connection to a f ashing light or a courtesy light The control unit is supplied by the manufacturer with the Flashing function enabled If you wish to enable the courtesy light proceed as follows use the SEL button to navigate to the LAMP CORT LED when fashing and then press the SET button The LAMP CORT button will light up permanently Repeat the procedure to restore the previous conf guration Flashing function The 230 Vac output will be activated each time that the automation is moving for the duration of the motor time If the Pause time is memorised the f ashing light will be
9. ts amendments at point 5 2 7 of EN 12453 Power supply and connection cables must be fixed using the cable glands supplied as optional accessories The gearmotor used to move the frame must comply with that prescribed at point 5 2 7 of EN 12453 Fix the control unit on a wall To mount it use the special support supplied with the casing and insert fixing screws in the designated spaces Mounting of a push button panel for manual control must be done positioning the push button panel where the user is not in a dangerous position in compliance with point 5 2 8 of EN 12453 The control unit does not have any type of isolating device for the 230 Vac line It will therefore be the responsibility of the installer to arrange an isolating device inside the plant It is necessary to install a mono phase switch with over voltage category III It must be positioned where it can be protected from accidental closing according to that prescribed in point 5 2 9 of EN 12453 In compliance with 5 4 2 of EN 12453 it is recommended to use gearmotors equipped with an electric mechanical release device so that the door can be moved manually in case of necessity In compliance with 5 4 3 of EN 12453 use electric mechanical release systems or similar devices which stop the door safely in the end run position Cables for power and connection to the motor suitable for insertion in the pg9 cable glands provided must have an outside diameter between 4 5
Download Pdf Manuals
Related Search
Related Contents
BL 981411-0 BL 981411-1 Indicateurs et contrôleurs de pH Resolución 01804 de 1989 Fellowes P600C ma ville - Ville de Saint M-Board – The Mind Keyboard User Manual-SNP-6201-PORTUGUESE_Web.indb Database 9 yn LevelOne FCS-1132 surveillance camera Samsung AV-R720 Home Theater System User Manual Copyright © All rights reserved.