1.                                     72       Mellanox Technologies 7      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      Revision History    This document was printed on December 10  2015     Table 1   Revision History Table       Date Rev Comments Changes       December 2015 1 3   Added port numbers to the specification tables  See Speci   fications on page 50    Updated MCX416A CCAT Specifications on page 59       December 2015 1 2 e Updated the following tables   MCX413A BCAT Specifications on page 50  MCX414A BCAT Specifications on page 51  MCXA15A BCAT Specifications on page 52  MCX416A BCAT Specifications on page 53  MCX413A GCAT Specifications on page 54  MCX414A GCAT Specifications on page 55  MCXA15A GCAT Specifications on page 56  MCX416A GCAT Specifications on page 57  MCXA15A CCAT Specifications on page 58  MCX416A CCAT Specifications on page 59    Updated Features and Benefits on page 13     Updated Section 3 7 1     On Windows     on page 19          November 2015 1 1   Updated power numbers in     MCX413A BCAT Specifications on page 50    MCX414A BCAT Specifications on page 51    MCX415A BCAT Specifications on page 52    MCX413A GCAT Specifications on page 54    MCX416A GCAT Specifications on page 57  e Added Airflow Specifications on page 60  e Added VMware Driver on page 43    Updated Updating Adapter Card Firmware on page 46       November 2015 1 0 First Release                   Mellanox Technologies 8    About this Ma
2.                  44   4 3 5 Firmware Programming                                               44  Chapter 5 Updating Adapter Card Firmware                                 46  5 1 Firmware Update Example                                             46  Chapter 6                                                                           47  6    General  os acd sve dta ate ste et a a neuestes 47  0 24 Ns 48  6 3  WiINdOWS Joss sees es eno eO T RTL V pat               49    Mellanox Technologies 4      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3         Chapter 7                              in RA AAA 50  7 1 MCX413A BCAT Specifications                                       50   7 2       414            Specifications                                       51   7 3       415            Specifications                                       52   7 4 MCX416A BCAT Specifications                                       53   7 5 MCX413A GCAT Specifications                                      54   7 6 MCX414A GCAT Specifications                                      55   77       415            Specifications                                      56   7 8 MCX416A GCAT Specifications                                      57   79       415            Specifications                                       58   7 10 MCX416A CCAT Specifications                                       59   7 11 Airflow Specifications                                                60
3.                  ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      6 2 Linux          cat etc issue   uname    a   cat proc cupinfo   grep    model name      uniq  Environment ofed_info   head  1  Information ifconfig    a    ethtool  lt interface gt   ethtool    1  lt interface_of Mellanox_port_num gt   ibdev2netdev          Card Detection Ispci   grep     Mellanox             Download and install MFT  http   www mellanox com content   pages php pg management_tools amp menu_section 34  Refer to the User Manual for installation instructions              Mellanox Firmware Tool   MFT  Once installed  run    mst start   mst status   flint  d  lt mst_device gt                               ibstat  Ports Information iby devine  Firmware Version To download the latest firmware version refer to  Upgrade http   www mellanox com supportdownloader   var log messages    Collect Log File                      dmesg  gt  system  logF          Mellanox Technologies 48      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      6 3 Windows          From the Windows desktop choose the Start menu and run  msinfo32  Environment To export system information to a text file  choose the Export option  Information from the File menu    Assign a file name and save              Download and install MFT  http   www mellanox com content   pages php pg management_tools amp menu_section 34  Refer to the User Manual for installation instruc
4.         31   4 1 8 2 Removing Signature from kernel Modules                                32   4 1 9 Performance Tuning                                          Sa              PORA 32   4 22  Windows  Diver x E LIE LM RR 33  4 2 1 Hardware and Software Requirements                                   33   4 2 2 Downloading Mellanox WinOF 2 Driver                                33   4 2 3 Installing Mellanox WinOF 2 Driver                                    34  4 2 3 1 Attended Installation                                                 34   4 2 3 2 Unattended Installation                                               38   42 4  Installation  Results   x ia seen een RR 39   4 2 5 Extracting Files Without Running Installation                             40   4 2 6 Uninstalling                WinOF 2                                              41  4 2 6 1 Attended Uninstallation                                               41   4 2 6 2 Unattended Uninstallation                                            42   4 2 7 Firmware Upgrade                                                   42   453    VMWare Driver sin                    dans ths          AUS      Ver        Y 43  4 3 1 Hardware and Software Requirements                                   43   4 3 2 Installing VMware                                                    43   4 3 3 Removing                         Driver                                     44   4 3 4 Loading Unloading Driver Kernel                          
5.         Mellanox    TECHNOLOGIES    Connect  Accelerate  Outperform       ConnectX   4 Ethernet Single and Dual Port  QSFP28 Adapter Card User Manual    P N     MCX413A BCAT  MCX414A BCAT  MCX415A BCAT  MCX416A BCAT  MCX413A GCAT  MCX414A   GCAT  MCX415A GCAT  MCX416A GCAT  MCX415A CCAT  MCX416A CCAT    Rev 1 3    www mellanox com         Rev 1 3                  THIS HARDWARE  SOFTWARE      TEST SUITE PRODUCT     PRODUCT S      AND ITS RELATED  DOCUMENTATION ARE PROVIDED BY MELLANOX TECHNOLOGIES    AS IS    WITH ALL FAULTS OF ANY  KIND AND SOLELY FOR THE PURPOSE OF AIDING THE CUSTOMER IN TESTING APPLICATIONS THAT USE  THE PRODUCTS IN DESIGNATED SOLUTIONS  THE CUSTOMER S MANUFACTURING TEST ENVIRONMENT  HAS NOT MET THE STANDARDS SET BY MELLANOX TECHNOLOGIES TO FULLY QUALIFY THE PRODUCT S   AND OR THE SYSTEM USING IT  THEREFORE  MELLANOX TECHNOLOGIES CANNOT AND DOES NOT  GUARANTEE OR WARRANT THAT THE PRODUCTS WILL OPERATE WITH THE HIGHEST QUALITY  ANY  EXPRESS OR IMPLIED WARRANTIES  INCLUDING  BUT NOT LIMITED TO  THE IMPLIED WARRANTIES OF  MERCHANTABILITY  FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT ARE DISCLAIMED   IN NO EVENT SHALL MELLANOX BE LIABLE TO CUSTOMER OR ANY THIRD PARTIES FOR ANY DIRECT   INDIRECT  SPECIAL  EXEMPLARY  OR CONSEQUENTIAL DAMAGES OF ANY KIND  INCLUDING  BUT NOT  LIMITED TO  PAYMENT FOR PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES  LOSS OF USE  DATA   OR PROFITS  OR BUSINESS INTERRUPTION  HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY   WHETHER I
6.         grep  E  kernel ib mlnx ofa kernel iser srp knem    xargs rpm  ql   grep   A ko     xargs strip  g  After the signature has been removed  a message as the below will no longer be presented  upon module loading      Request for unknown module key  Mellanox Technologies signing key   61feb074  c7292  958419386ffdd9d5ca999e403  err  11     However  please note that a similar message as the following will still be presented      my module  module verification failed  signature and or required key missing   taint   ing kernel     This message is presented once  only for each boot for the first module that either has no  signature or whose key is not in the kernel key ring  So it s much easier to miss this mes   sage  You won t see it on repeated tests where you unload and reload a kernel module until  you reboot  There is no way to eliminate this message     Step 2  Update the initramfs on RHEL systems with the stripped modules     mkinitrd  boot initramfs    uname  r  img   uname  r    force  4 1 9 Performance Tuning    For further information on Linux performance  please refer to the Performance Tuning Guide for  Mellanox Network Adapters     Mellanox Technologies 32      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      4 2 Windows Driver    For Windows  download and install the latest Mellanox WinOF 2 for Windows software package  available via the Mellanox web site at  http   www mellanox com   gt  Products   gt  Software   gt   Eth
7.        Air Flow  See Airflow Specifications on page 60       Safety  CB   cTUVus   CE       Regulatory                FCC   VCCI   ICES   RCM       RoHS  RoHS R6                a  Typical power for ATIS traffic load   b  For both operational and non operational states     Mellanox Technologies 58      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      7 10       416            Specifications    Table 18   MCX416A CCAT Specifications Table    Size  2 71 in  x 5 6 in   68 90mm x 142 24 mm      low profile       Physical  Connector  Dual QSFP28  Copper and optical        Ethernet  100GBASE CR4  100GBASE KR4  100GBASE SR4  56GBASE R4   SOGBASE R2  SOGBASE R4  40GBASE CR4  40GBASE KR4  40GBASE   SR4  40GBASE LR4  40GBASE ER4  40GBASE R2  25GBASE R  20GBASE   KR2  1000BASE CX  1000BASE KX  10GBASE SR  1                    10GBASE ER  10GBASE CX4  I0GBASE KX4  10GBASE CR  10GBASE         SGMII    Protocol Support       Data Rate  1 10 25 40 50 56 100 Gb s     Ethernet       PCI Express Gen3  SERDES   8 0GT s  16 lanes  2 0 and 1 1 compatible        Voltage  12V  3 3V       Typical Power     Passive Cables  16 12W       Maximum Power  Passive Cables  18 04W  3 5W Active Cables  24 80W       Power and      Maximum power available through QSFP28 port  3 5W  Environmental       Temperature  Operational 0 C to 55 C  Non operational  40     to 70           Humidity  9095 relative humidity        Air Flow  See Airflow Specifications on page 60       Safet
8.       23   4 1 3 2 Installation Results                                                  25   41 33 Installation Logging                                                  25   41 34    Openibd Script      ee nn eu ea 25   4 1 3 5 Driver Load Upon System Boot                                        25   4 1 3 6  minxofedinstall Return Codes                                         26   4 1 4 Uninstalling Mellanox                                                 26   4 1 5 Installing MLNX OFED using YUM                                   26  4 1 5 1 Setting up MLNX OFED YUM Repository                              26   4 1 5 2 Installing MLNX OFED using the YUM Tool                            28   4 1 5 3 Uninstalling Mellanox OFED using the YUM Tool                        29   4 1 6 Installing MLNX          using apt get                                   29  4 1 6 1 Setting up MLNX OFED apt get Repository                             29   4 1 6 2 Installing MLNX OFED using the apt get Tool                           29   4 1 6 3 Uninstalling Mellanox OFED using the apt get Tool                       30   4 1 7 Updating Firmware After Installation                                    30  4 1 7 1 Updating the Device Online                                            30   4 1 7 2 Updating the Device Manually                                         30   4 1 8  UEFI Secure  Boot    cce un er er eme een          reve 31  4 1 8 1 Enrolling Mellanox s x 509 Public Key On your Systems            
9.     PCI Express  PCIe  SerDes Speed PCIe 3 0 x16 8G T s     MCX415A BCAT   MCX416A BCAT         415               MCX416A GCAT   MCX415A CCAT   MCX416A   CCAT    Mellanox Technologies 11      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      RoHS R6    Adapter IC Part Number MT27708A0 FDCF CE    4115 for Physical Function  PF                         4116 for Virtual Function              Mellanox Technologies 12      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      1 2 Features and Benefits    Table 4   Features     Uses PCIe Gen 3 0  1 1 and 2 0 compatible  through an x8 or x16 edge connector  PCI Express  PCIe  up to 8GT s    Mellanox adapters comply with the following IEEE 802 3 standards       100GbE  56GbE   50GbE  40GbE   25GbE  10GbE   1GbE      IEEE 802 3bj  802 3bm 100 Gigabit Ethernet      25G Ethernet Consortium 50 Gigabit Ethernet      IEEE 802 3ba 40 Gigabit Ethernet      IEEE 802 3by 25 Gigabit Ethernet      IEEE 802 3ae 10 Gigabit Ethernet      IEEE 802 3az Energy Efficient Ethernet   Up to 100 Gigabit     IEEE 802 3ap based auto negotiation and KRstartup   Ethernet     Proprietary Ethernet protocols  20 40GBASE R2  50 56GBASE R4        IEEE 802 3ad  802 1AX Link Aggregation      IEEE 802 10  802 1P VLAN tags and priority      IEEE 802 1Qau  QCN    Congestion Notification      IEEE 802 1Qaz  ETS       IEEE 802 1Qbb  PFC       IEEE 802 1Qbg      IEEE 1588v2      Jumbo frame support  9 6KB  
10.    7 12 Adapter LED Operation                                               61   7 13 Board Mechanical Drawing and Dimensions                              61   7 14 Bracket Mechanical Drawing                                            62   Appendix    Interface Connectors                                                64       QSFP28 Connector                                                   64      2 PCI Express x8 or x16 Connector Pinout                             66         I2C compatible Connector                                             68   Appendix    Finding the MAC and Serial Number on the Adapter Card            69  Appendix    Safety Warnings A         73  Appendix D Avertissements de s  curit   d   installation  Warnings in French         75  Appendix E Sicherheitshinweise  Warnings in German                          77    Appendix    Advertencias de seguridad para la instalaci  n  Warnings in Spanish   79    Mellanox Technologies 5      ConnectX 4 Ethernet Single and Dual        QSFP28 Adapter Card User Manual Rev 1 3    List of Tables       Table 1  Revision History                                                             8  Tabl   2      Documents Tast ee cane ee                  aed        AE C EE 9  Table 3  Single and Dual port Ethernet Adapter                                             11  Table4                   less eo Bean a ONG Gla eS      Gee SaaS 13  Table 5  Hardware and Software Requirements                                        21  Table
11.    PCI Express   stores and accesses Ethernet fabric connection information and  packet data   SPI   includes       16     SPI Flash device  M25PX16 VMN6P device by ST  Microelectronics     EEPROM   accessible through the 12C compatible interface  The EEPROM  capacity is 128Kb     Memory    In order to better scale their networks  data center operators often create overlay  networks that carry traffic from individual virtual machines over logical tunnels  in encapsulated formats such as NVGRE and VXLAN  While this solves network   Overlay Networks scalability issues  it hides the TCP packet from the hardware offloading engines   placing higher loads on the host CPU  ConnectX 4 effectively addresses this by  providing advanced NVGRE and VXLAN hardware offloading engines that  encapsulate and de capsulate the overlay protocol    ConnectX 4  utilizing IBTA RDMA  Remote Data Memory Access  and RoCE   RDMA over Converged Ethernet  technology  delivers low latency and high        A performance over Band and Ethernet networks  Leveraging data center bridging              DCB  capabilities as well      ConnectX 4 advanced congestion control    hardware mechanisms  RoCE provides efficient low latency RDMA services over  Layer 2 and Layer 3 networks     PeerDirect    communication provides high efficiency RDMA access by eliminat   ing unnecessary internal data copies between components on the PCIe bus  for   Mellanox PeerDirect    example  from GPU to CPU   and therefore significantly 
12.    the green LED is lit and the yellow LED is off  then the logical link has not  been established                7 13 Board Mechanical Drawing and Dimensions     2      dimensions are in millimeters        All the mechanical tolerances            0 1mm     Figure 3  Mechanical Drawing of the Dual port Adapter Card        142 24       ES      e              mu mm E                       D  F      c  irt LM                              hig eae               ELLE            a       cn      68 90   _            E   u                Mellanox Technologies 61      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      7 14 Bracket Mechanical Drawing    Figure 4  Single port Bracket             Figure 5  Dual port Bracket             Mellanox Technologies 62      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      Appendix A  Interface Connectors Pinout          QSFP28 Connector Pinout    Figure 6  Connector and Cage Views  Top     s 18 35  View into Rear  ee 850           1S dPOW    WI                    apod                  EXL  NO            uLXL            9220220      2 2 2  55856334       oO 20 2                 aD  lt s 2 zo  0  O  22622688 EREL 922702  UJ  o g 2 3 oF u Oo 5 955      28                18 35    View into Front of Cage  8             LPMode By          Table 20   Connector Pin Number and Name to Signal Name Map                                                                Connector Pin Number Co
13.   Download  This chapter describes how to install and test the Mella   nox OFED for Linux package on a single host machine with Mellanox ConnectX 4 adapter  hardware installed    4 1 1 Hardware and Software Requirements    Table 5   Hardware and Software Requirements       Requirements Description       Platforms A server platform with an adapter card based      one of the following Mella   nox Technologies    Ethernet HCA devices    e MT4115 ConnectX   4  EN   firmware  fw ConnectX4    For the list of supported architecture platforms  please refer to the Mellanox  OFED Release Notes file           Required Disk 1GB   Space for   Installation   Device ID For the latest list of device IDs  please visit Mellanox website        Operating System   Linux operating system   For the list of supported operating system distributions and kernels  please  refer to the Mellanox OFED Release Notes file        Installer The installation requires administrator privileges on the target machine   Privileges                4 1 2 Downloading Mellanox OFED  Step1  Verify that the system has a Mellanox network adapter  HCA NIC  installed   The following example shows a system with an installed Mellanox HCA       lspci  v   grep Mellanox  06 00 0 Network controller  Mellanox Technologies MT4115 Family  ConnectX 4   Subsystem  Mellanox Technologies Device 0024   Step 2  Download the ISO image to your host     The image   s name has the format MLNX_OFED_LINUX  lt ver gt   lt OSlabel gt  lt CPU arch 
14.   Non operational  40  C to 70  C       Humidity  90  relative humidity        Air Flow  See Airflow Specifications on page 60       Safety  CB   cTUVus   CE       Regulatory                FCC   VCCI   ICES   RCM       RoHS  RoHS R6                a  Typical power for ATIS traffic load   b  For both operational and non operational states     Mellanox Technologies 57      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      79   MCX415A CCAT Specifications    Table 17   MCX415A CCAT Specifications Table    Size  2 71 in  x 5 6 in   68 90mm x 142 24 mm      low profile       Physical  Connector  Single QSFP28  Copper and optical        Ethernet  100GBASE CR4  100GBASE KR4  100GBASE SR4  56GBASE R4   SOGBASE R2  SOGBASE R4  40GBASE CR4  40GBASE KR4  40GBASE   SR4  40GBASE LR4  40GBASE ER4  40GBASE R2  25GBASE R  20GBASE   KR2  1000BASE CX  1000BASE KX  10GBASE SR  1                    10GBASE ER  10GBASE CX4  I0GBASE KX4  10GBASE CR  10GBASE         SGMII    Protocol Support       Data Rate  1 10 25 40 50 56 100 Gb s     Ethernet       PCI Express Gen3  SERDES   8 0GT s  16 lanes  2 0 and 1 1 compatible        Voltage  12V  3 3V       Typical Power     Passive Cables  13 91W       Maximum Power  Passive Cables  15 70W  3 5W Active Cables  19 59W       Power and      Maximum power available through QSFP28 port  3 5W  Environmental       Temperature  Operational 0 C to 55 C  Non operational  40     to 70           Humidity  9095 relative humidity 
15.   P3V3 8  GND 30   LAN 3V3STB ALERT N  SMB LAN 3V3STB CLK  SMB LAN 3V3STB DAT  PCIE WAKE N   NCSI RXER   GND 31   NCSI            NCSI TXDl   GND 32   GND 33          100M      21 DP         100M MEZZI DN  GND 34   GND 35  MEZZ TX DP    0   MEZZ TX DN    0   GND 36   GND 37  MEZZ TX DP C 1   MEZZ TX DN    1   GND 38   GND 39  MEZZ TX DP C 2   MEZZ TX DN C 2   GND 40   GND 41   MEZZ TX DP C 3      3  MEZZ TX DN C 3     GND 42  GND 43  MEZZ TX DP C 4                   TX DN C 4     GND 44  GND 45  MEZZ TX DP    5      0  MEZZ TX DN C 5     GND 46  GND 47  MEZZ TX DP C 6      4  MEZZ TX DN C 6          Wo    GND 48  GND 49  MEZZ TX DP C 7   MEZZ TX DN C 7   GND 50  GND 51  MEZZ PRSNTA2 N    MEZZ PRSNTAl N BASEBOARD A ID    P5V AUX 1  P5V AUX 2  P5V AUX 3    P3V3 1   P3V3 2   P3V3 3   P3V3 4   NCSI RCSDV  NCSI RCLK  NCSI TXEN  PERST NO   MEZZ SMCLK  MEZZ SMDATA  GND 5   GND 6   NCSI RXDO  NCSI_RXD1  GND 7   GND 8   CLK 100M MEZZ2 DP  CLK 100M MEZZ2 DN  GND 9   GND 10  MEZZ      DP 0   MEZZ RX DN 0   GND 11   GND 12  MEZZ      DP 1   MEZZ RX DN 1   GND 13   GND 14  MEZZ RX DP 2   MEZZ RX DN 2   GND 15   GND 16  MEZZ RX DP 3   MEZZ RX DN 3   GND 17   GND 18  MEZZ RX DP 4   MEZZ RX DN 4   GND 19   GND 20  MEZZ RX DP 5   MEZZ           5   GND 21   GND 22  MEZZ RX DP 6   MEZZ RX DN 6   GND 23   GND 24  MEZZ RX DP 7   MEZZ RX DN 7   GND 25      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      Figure 8  PCle x16 Connector Pinout                    M
16.  00 02 C9 27 05 1C  Made in Israel    e       Mellanox Technologies 72      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3    Appendix     Safety Warnings    1  Installation Instructions    LA Read all installation instructions before connecting the equipment to the power source     2  Over temperature    This equipment should not be operated in an area with an ambient temperature exceed   LA ing the maximum recommended  55  C  131  F     To guarantee proper air flow  allow at least 8      3 inches  of clearance around the ven    tilation openings     3  During Lightning   Electrical Hazard    During periods of lightning activity  do not work on the equipment or connect or dis   connect cables     4  Copper Cable Connecting Disconnecting    Some copper cables are heavy and not flexible  as such they should be carefully  La attached to or detached from the connectors  Refer to the cable manufacturer for spe   cial warnings and instructions     5  Equipment Installation    This equipment should be installed  replaced  or serviced only by trained and qualified  personnel     6  Equipment Disposal    Disposal of this equipment should be in accordance to all national laws and regula   tions     7  Local and National Electrical Codes    This equipment should be installed in compliance with local and national electrical  A codes     8  Hazardous Radiation Exposure    Caution     Use of controls or adjustment or performance of procedures other than  
17.  1 3      you need to perform the steps below  The following steps are also appropriate in case you wish to  burn newer firmware that you have downloaded from Mellanox Technologies    Web site  http     www mellanox com  gt  Support  gt  Firmware Download      Step 1  Get the device   s PSID     mlxfwmanager_pci   grep PSID  PSID       1210110019    Step 2  Download the firmware BIN file from the Mellanox website or the OEM website   Step 3  Burn the firmware   mlxfwmanager pci  i   fw file bin      Step 4  Reboot your machine after the firmware burning is completed     4 18        Secure Boot    All kernel modules included in MLNX OFED for RHEL7 and SLES12 are signed with x 509  key to support loading the modules when Secure Boot is enabled     4 1 8 1 Enrolling Mellanox s x 509 Public Key On your Systems    In order to support loading MLNX OFED drivers when an OS supporting Secure Boot boots on  a UEFI based system with Secure Boot enabled  the Mellanox x 509 public key should be added  to the UEFI Secure Boot key database and loaded onto the system key ring by the kernel     Follow these steps below to add the Mellanox s x 509 public key to your system     Prior to adding the Mellanox s x 509 public key to your system  please make sure     the  mokutil  package is installed on your system      the system 1  booted in UEFI mode    Step 1  Download the x 509 public key     wget http   www mellanox com downloads ofed mlnx signing key pub der  Step2  Add the public key to the 
18.  2  Installation Results                 cues ERR ee en Hemer 39  Figure 3  Mechanical Drawing of the Dual port Adapter Card                              61  Figure 4  Single port                                                                    62  Figure  gt        Dual port Bracket vu            Ki        la      ob a        62  Figure 6  Connector and Cage Views                                                1 64  Figure 7       x8 Connector Pinout                                                   66  Figure 8  PCIe x16 Connector Pinout                                                 67  Figure 9  Compatible Connector Plug and Pinout                                        68  Figure 10  MCX413A BCAT Board Label                                              69  Figure 11  MCX414A BCAT Board Label                                              69  Figure 12  MCX415A BCAT Board Label                                              69  Figure 13  MCX416A BCAT Board Label                                              70  Figure 14  MCX413A GCAT Board Label                                              70  Figure 15  MCX414A GCAT Board Label                                              70  Figure 16  MCX415A GCAT Board Label                                              71  Figure 17  MCX415A CCAT Board Label                                              71  Figure 18  MCX416A GCAT Board Label                                              71  Figure 19  MCX416A CCAT Board Label          
19.  22 Keyboards  A Mice and other pointing devices      Monitors  Network adapters  Broadcom NetXtreme Gigabit Ethernet  Broadcom NetXtreme Gigabit Ethernet  2        Broadcom NetXtreme Gigabit Ethernet  3  Broadcom NetXtreme Gigabit Ethernet  4  Mellanox ConnectX 4 VPI Adapter  3  Mellanox ConnectX 4 VPI Adapter  4       Other devices       Base System Device  1  Ports  COM  amp  LPT   dm Print queues  b n Processors        Storage controllers          System devices     9 Universal Serial Bus controllers                Mellanox Technologies 39      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      4 2 5 Extracting Files Without Running Installation  To extract the files without running installation  perform the following steps     Step 1  Open a CMD console  Windows Server 2012 R2    Click Start    gt  Task Manager   gt File    gt   Run new task    gt  and enter CMD     Step 2  Extract the driver and the tools    gt  MLNX WinOF2 1 21 All x64  a      Toextract only the driver files      MLNX WinOF2 1 21 All x64  a  vMT DRIVERS ONLY 1    Step 3  Click Next to create a server image     Welcome to the InstallShield Wizard for  MLNX_VPI    The InstallShield R  Wizard will install MLNX_  PI on your  computer  To continue  click Next     WARNING  This program is protected by copyright law and  international treaties     Network Location    Specify    network location for the server image of the product     Enter the network location or click Chang
20.  6   minxofedinstall Return                                                         1 26  Table 7    Hardware and Software Requirements                                        33  Table 8    Hardware and Software Requirements                                        43  Table 9    MCX413A BCAT Specifications                                               50  Table 10        414            Specifications Table                                       51  Table 11        415            Specifications                                               52  Table 12  MCX416A BCAT Specifications                                               53  Table 13        413   0       Specifications Table                                      54  Table 14        414   0       Specifications Table                                      55  Table 15  MCX415A GCAT Specifications                                               56  Table 16  MCX416A GCAT Specifications                                               57  Table 17        415            Specifications                                               58  Table 18  MCX416A CCAT Specifications                                               59  Table 19  Physical and Logical Link Indications                                        61    Mellanox Technologies 6      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      List of Figures    Figure 1  PCI Device  Example                                                       19  Figure
21.  6  Eliminaci  n de equipos    La eliminaci  n definitiva de este equipo se debe efectuar conforme a todas las leyes y  reglamentaciones nacionales     7  C  digos el  ctricos locales y nacionales    LA Este equipo se debe instalar conforme    los codigos el  ctricos locales y nacionales     8  Exposici  n a niveles de radiaci  n peligrosos    Precauci  n  el uso de controles o ajustes o la realizaci  n de procedimientos distintos de  los que aqu   se especifican podr  an causar exposici  n a niveles de radiaci  n peligrosos        Mellanox Technologies 79       ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter          User Manual Rev 1 3       PRODUCTO LASER DE CLASE 1 y referencia a las normas de l  ser m  s recientes   IEC 60825 1 2007 03 y EN 60825 1 2007    Mellanox Technologies 80    
22.  AA 16   3 1 2 Operating Systems Distributions                                       16   313  Software Stacks ansehe tes 16   3 2  Safety Precautions 59 4 208 ee           e beet arid 16   3 3 Pre installation Checklist                                              16   3 4 Bracket Installation Instructions                                         16   3 4 1 Removing the Existing Bracket                                        17   3 4 2 Installing the New                                                          17   3 5 Card Installation Instructions                                          17   3 67 Cables and Modules         A eae a e        18   3 6       Cable Installation              donk               Bear 18   3 7 Identify the Card in Your System                                      19   FDA OR WindOoWSs      okay gb                  Robes des 19                              Rt hot ett                                       20   Chapter 4 Driver                                                                   21  4T           Drivers      iR 21   4 1 1 Hardware and Software Requirements                                   21   4 1 2 Downloading Mellanox                                                  21   4 1 3 Installing Mellanox OFED                                              22    Mellanox Technologies 3      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      4 1 3 1 Installation Procedure                                          
23.  Card User Manual Rev 1 3      1 Introduction    This is the User Guide for Mellanox Technologies Ethernet adapter cards based on the Con   nectX   4 integrated circuit device  These adapters connectivity provide the highest performing  and most flexible interconnect solution for PCI Express Gen3 servers used in Enterprise Data  Centers  High Performance Computing  and Embedded environments     This chapter covers the following topics      Section 1 1     Product Overview     on page 11     Section 1 2     Features and Benefits     on page 13     Section 1 3     Operating Systems Distributions     on page 14     Section       OpenFabrics Windows Distribution  WinOF 2      on page 14    1 1 Product Overview    The following section provides the ordering part number  port speed  number of ports  and PCI  Express speed  Each adapter comes with two bracket heights   short and tall     Table 3   Single and Dual port Ethernet Adapter Cards       Single port cards   MCX413A BCAT  MCX413A GCAT  MCX415A BCAT  MCX415A GCAT    MCX415A CCAT  Ordering Part Number  OPN   Dual port cards     MCX414A BCAT  MCX414A GCAT  MCX416A BCAT  MCX416A GCAT  MCX416A CCAT       MCX413A BCAT   MCX414A BCAT   MCX415A BCAT    MCX416A BCAT  40GbE    Data Transmission Rate MCX413A GCAT  MCX414A GCAT   MCX415A GCAT    MCX416A GCAT  50GbE    MCX415A CCAT MCX416A CCAT   100GbE    Network Connector Types Single and dual port QSFP28    PCIe 3 0 x8 8GT s   MCX413A BCAT   MCX414A BCAT   MCX413A GCAT    MCX414A GCAT
24.  Dual Port QSFP28 Adapter Card User Manual Rev 1 3        In case your machine has an unsupported network adapter device  no firmware update      2    will occur and the error message below will be printed  Please contact your hardware  vendor for help on firmware updates     Error message   Device  1     Device  0000 05 00 0   Part Number    Description              MT 0DB0110010   Versions  Current Available  FW 2 4  1000 N A   Status  No matching image found    Step 4  Reboot the machine if the installation script performed firmware updates to your network  adapter hardware  Otherwise  restart the driver by running    etc init  d openibd  restart    After the installer completes  information about the Mellanox OFED installation such as prefix    kernel version  and installation parameters can be retrieved by running the command  etc    band info     Most of the Mellanox OFED components can be configured or reconfigured after the installation  by modifying the relevant configuration files  See the relevant chapters in this manual for details     The list of the modules that will be loaded automatically upon boot can be found in the  etc   band openib conf file     Mellanox Technologies 24      ConnectX 4 Ethernet Single and Dual        QSFP28 Adapter Card User Manual Rev 1 3      4 1 3 2 Installation Results       Software e Most of MLNX_OFED packages are installed under the     usr    directory  except for the following packages which are installed under the     opt    dir
25.  Install the desired group   apt get install    group name gt      Example        apt get install mlnx ofed all    4 1 6 3 Uninstalling Mellanox OFED using the apt get Tool    Use the script  usr sbin ofed uninstall sh to uninstall the Mellanox OFED package   The script 1  part of the ofed scripts RPM     4 1 7 Updating Firmware After Installation    The firmware can be updated in one of the following methods     4 1 7 1 Updating the Device Online  To update the device online on the machine from Mellanox site  use the following command line   mlxfwmanager   online  u  d   device    Example     mlxfwmanager   online  u  d 0000 09 00 0  Querying Mellanox devices firmware           Device  1    Device Type  ConnectX3   Part Number  MCX354A FCA   2   4  Description  ConnectX 3 VPI adapter card  dual port QSFP  FDR IB  56Gb s  and  40GigE  PCIe3 0 x8 8GT s  RoHS R6  PSID       1020120019          Device           0000 09 00 0   Portl GUID  0002c9000100d051   Port2 MAC  0002c9000002   Versions  Current Available  FW 2532 5000 2 33 5000  Status  Update required    Found 1 device s  requiring firmware update  Please use  u flag to perform the update     4 1 7 2 Updating the Device Manually    In case you ran the minxofedinstal1 script with the      without fw update    option or you  are using an OEM card and now you wish to  manually  update firmware on your adapter card s      Mellanox Technologies 30      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev
26.  To remove the modules  the command must be run in the same order as shown in the    example above        4  Reboot the server     4 3 4 Loading Unloading Driver Kernel Modules     To unload the driver     esxcfg module  u nmlx5 core       To load the driver      etc init d sfcbd watchdog stop   esxcfg module nmlx5 core   etc init d sfcbd watchdog start   kill  POLL   cat  var run vmware vmkdevmgr pid        To restart the driver      etc init d sfcbd watchdog stop   esxcfg module  u nmlx5 core   esxcfg module nmlx5 core   etc init d sfcbd watchdog start   kill  POLL   cat  var run vmware vmkdevmgr pid     4 3 5 Firmware Programming    1  Download the VMware bootable binary images v4 1 0 from the Mellanox Firmware Tools   MFT  site       File  mft 4 1 0 34 10EM 610 0 0 2770837 x86 64 vib  MDSSUM  7b8552c1a22b554c4a280d679dfd528f     File  nmst 3 8 0 56   OEM 600 0 0 2295424 x86 64 vib  MDSSUM  0426a9ab6e759ad44942d5061a6e9cfe    Mellanox Technologies 44      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      2  Install the image according to the steps described in the MFT User Manual        2    The following procedure requires custom boot image downloading  mounting and boot   3 ing from a USB device     Mellanox Technologies 45      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3    5 Updating Adapter Card Firmware    Each card is shipped with the latest version of qualified firmware at the time of manufact
27.  the hardware is not configured correctly    173 Failed to start the mst driver                4 1 4 Uninstalling Mellanox             Use the script  usr sbin ofed_uninstall sh to uninstall the Mellanox OFED package   The script is part of the ofed scripts RPM     4 1 5 Installing MLNX_OFED using YUM  This type of installation is applicable to RedHat OEL  Fedora  XenServer Operating Systems     4 1 5 1 Setting      MLNX OFED YUM Repository  Step 1  Log into the installation machine as root   Step 2  Mount the ISO image on your machine     mount  o ro loop          OFED LINUX  lt ver gt   lt 0S label gt   lt CPU arch gt  iso  mnt    You can download it from http   www mellanox com  gt  Products  gt  Software gt  Ethernet   Drivers     Mellanox Technologies 26      ConnectX 4 Ethernet Single and Dual        QSFP28 Adapter Card User Manual Rev 1 3      Step3  Download and install Mellanox Technologies GPG KEY   The key can be downloaded via the following link   http   www mellanox com downloads ofed R PM GPG KEY Mellanox      wget http    www mellanox com downloads ofed RPM GPG KEY Mellanox     2014 04 20 13 52 30   http   www mellanox com downloads ofed RPM GPG KEY Mellanox  Resolving www mellanox com    72 3 194 0   Connecting to www mellanox com 72 3 194 0  80    connected    HTTP request sent  awaiting response    200 OK   Length  1354  1 3K   text plain    Saving to   RPM GPG KEY Mellanox     100                                                     gt               K s in 0
28.  to gently push the LEDs using a  small screwdriver to align the LEDs with the holes in the bracket     2  Screw on the bracket using the screws and washers saved from the bracket removal procedure  above     3  Make sure that the LEDs are aligned onto the bracket holes     4  Use a torque driver to apply up to 2 Ibs in torque on the screws     3 5          Installation Instructions  1  Before installing the card  make sure that the system is off and the power cord is not con   nected to the server  Please follow proper electrical grounding procedures   2  Open the system case     3  Place the adapter in an available PCI Express slot     A lesser width adapter can be seated into a greater width slot  x8 in a x16   but a  greater width adapter cannot be seated into a lesser width slot  x16 in a x8   Align the  e  adapter connector edge with the PCI Express connector slot     4  Applying even pressure at both corners of the card  insert the adapter card into the slot until 1t    is firmly seated  When the adapter is properly seated  the adapter port connectors are aligned  with the slot opening  and the adapter faceplate is visible against the system chassis     Do not use excessive force when seating the card  as this may damage the system or  the adapter     Mellanox Technologies 17      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      5  Secure the adapter with the adapter clip      screw     6  Close the system case     3 6 Cables and Mo
29. 04      MAC  00 02 C9 27 05 1C  PE  Made in Israel    Figure 14  MCX413A GCAT Board Label    Model No  CX413A    ConnectX 4 50GbE  P N  MCX413A GCAT j    2015 10 08         Rev as    S N  MT0806X01504 Ris    MAC  00 02 C9 27 05 1C 1  Made in Israel            Figure 15  MCX414A GCAT Board Label    Model No  CX414A    ConnectX 4 50GbE  P N  MCX414A GCAT    2015 10 08    INN IN Rev  At    S N  MT0806X01504    MAC  00 02 C9 27 05 1C  Made in Israel       Mellanox Technologies 70         ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter          User Manual Rev 1 3      Figure 16  MCX415A GCAT Board Label  Model No  CX415A    ConnectX 4 50GbE  P N  MCX415A GCAT    2015 10 08  ELE HIA Rev    1    S N  MT0806X01504    MAC  00 02 C9 27 051C  Made in Israel                     Figure 17        415            Board Label    Model No  CX415A  ConnectX 4 100GbE  P N  MCX415A CCAT    2015 10 08  MOOO          Rev    4    S N  MT0806X01504        MAC  00 02 C9 27 05 1C       Made      Israel       Figure 18  MCX416A GCAT Board Label    Model No  CX416A  ConnectX 4 50GbE  P N  MCX416A GCAT       2015 10 08             Rev    1      MT0806X01504            00 02 C9 27 05 1C  Made in Israel                     Mellanox Technologies 71       ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual       Rev 1 3    Figure 19  MCX416A CCAT Board Label    Model No  CX416A    ConnectX 4 100GbE  P N  MCX416A CCAT    2015 10 08  EMEN Rev  AS    S N        806  01504           
30. 24 mm      low profile       Physical  Connector  Single QSFP28  Copper and optical        Ethernet  SOGBASE R2  50GBASE R4  40GBASE CR4  40GBASE KR4   40GBASE SR4  40GBASE LR4  40GBASE ER4  40GBASE R2  25GBASE R   20GBASE KR2  1000BASE CX  1000BASE KX  10GBASE SR  10GBASE   LR 10GBASE ER  10GBASE CX4  10GBASE KX4  I0GBASE CR    Protocol Support    0GBASE KR  SGMII       Data Rate  1 10 25 40 50 Gb s     Ethernet       PCI Express Gen3  SERDES   8 0GT s  8 lanes  2 0 and 1 1 compatible        Voltage  12V  3 3V       Typical Power     Passive Cables  9 81W       Maximum Power  Passive Cables  11 52W  3 5W Active Cables  15 41 W       Power and      Maximum power available through QSFP28 port  3 5W  Environmental       Temperature  Operational 0  C to 55  C  Non operational  40  C to 70  C       Humidity  90  relative humidity        Air Flow  See Airflow Specifications on page 60       Safety  CB   cTUVus   CE       Regulatory                FCC   VCCI   ICES   RCM       RoHS  RoHS R6                a  Typical power for ATIS traffic load   b  For both operational and non operational states     Mellanox Technologies 54      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      7 6   MCX414A GCAT Specifications    Table 14         414            Specifications Table    Size  2 71 in  x 5 6 in   68 90      x 142 24 mm    low profile       Physical  Connector  Dual QSFP28  Copper and optical        Ethernet  50GBASE R2  50GBASE R4  40GBASE CR4  40G
31. 3 Specification This is the IEEE Ethernet specification  http   standards ieee org getieee802          PCI Express 3 0 Specifications Industry Standard PCI Express 3 0 Base and Card Electromechan   ical Specifications  https   pcisig com specifications                   Document Conventions    When discussing memory sizes  MB and MBytes are used in this document to mean size in mega  Bytes  The use of Mb or Mbits  small b  indicates size in mega bits  In this document PCle is  used to mean PCI Express     Technical Support    Customers who purchased Mellanox products directly from Mellanox are invited to contact us  through the following methods       URL  http   www mellanox com   gt  Support    E mail  support mellanox com    Tel   1 408 916 0055    Customers who purchased Mellanox M 1 Global Support Services  please see your contract for  details regarding Technical Support        Customers who purchased Mellanox products through a Mellanox approved reseller should first  seek assistance through their reseller     Firmware Updates    The Mellanox support downloader contains software  firmware and knowledge database infor   mation for Mellanox products  Access the database from the Mellanox Support web page     http   www mellanox com   gt  Support  Or use the following link to go directly to the Mellanox Support Download Assistant page        http   www mellanox com supportdownloader      Mellanox Technologies 10      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter
32. 8    2014 04 20 13 52 30  247 MB s     RPM GPG KEY Mellanox  saved  1354 1354     Step 4  Install the key       sudo rpm   import RPM GPG KEY Mellanox   warning  rpmts HdrFromFdno  Header V3 DSA SHA1 Signature  key ID 6224c050  NOKEY  Retrieving key from file    repos MLNX OFED   MLNX OFED file gt  RPM GPG KEY Mellanox  Importing GPG key 0x6224C050    Userid   Mellanox Technologies  Mellanox Technologies   Signing Key v2   lt support mel   lanox com gt     From    repos MLNX OFED   MLNX OFED file gt  RPM GPG KEY Mellanox   Is this ok  y N      Step 5  Check that the key was successfully imported             rpm  q gpg pubkey   q      NAME    VERSION    RELEASE  t  SUMMARY  n    grep Mellanox  gpg pubkey a9e4b643 520791ba gpg Mellanox Technologies  lt support mellanox com gt      Step 6  Install the createrepo rpm package       yum install createrepo    Step7  MLNX OFED YUM repository using the           create yum repo sh  script located in  the downloaded MLNX OFED package         mlnx create yum repo sh   mlnx ofed  mnt   target  repos  Creating MLNX OFED LINUX YUM Repository under  repos      See log file  tmp mlnx yum 24250 10g   comps file was not provided  going to build it      Copying RPMS      Building YUM Repository      Creating YUM Repository settings file at   tmp mlnx ofed repo  Done   Copy  tmp mlnx ofed repo to  etc yum repos d  to use MLNX OFED YUM Repository     Step 8           the created YUM repository configuration file to  etc yum repos d           cp  
33. BASE KR4   40GBASE SR4  40GBASE LR4  40GBASE ER4  40GBASE R2  25GBASE R   20GBASE KR2  1000BASE CX  1000BASE KX  10GBASE SR  10GBASE   LR 10GBASE ER  10GBASE CX4  10GBASE KX4  I0GBASE CR    Protocol Support    0GBASE KR  SGMII       Data Rate  1 10 25 40 50 Gb s     Ethernet       PCI Express Gen3  SERDES   8 0GT s  8 lanes  2 0 and 1 1 compatible        Voltage  12V  3 3V       Typical Power   Passive Cables  TBD       Maximum Power  Passive Cables  TBD  1 5W Active Cables  TBD       Power and      Maximum power available through QSFP28 port  TBD  Environmental       Temperature  Operational 0  C to 55  C  Non operational  40  C to 70  C       Humidity  90  relative humidity        Air Flow  TBD       Safety  CB   cTUVus   CE       Regulatory                FCC   VCCI   ICES   RCM       RoHS  RoHS R6                a  Typical power for ATIS traffic load   b  For both operational and non operational states     Mellanox Technologies 55      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      7 7   MCX415A GCAT Specifications  Table 15   MCX415A GCAT Specifications Table    Size  2 71 in  x 5 6 in   68 90mm x 142 24 mm      low profile       Physical  Connector  Single QSFP28  Copper and optical        Ethernet  50GBASE R2  50GBASE R4  40GBASE CR4  40GBASE KR4   40GBASE SR4  40GBASE LR4  40GBASE ER4  40GBASE R2  25GBASE R   20GBASE KR2  1000BASE CX  1000BASE KX  10GBASE SR  10GBASE   LR 10GBASE ER  10GBASE CX4  10GBASE KX4  I0GBASE CR    Protoc
34. HCA devices   e     27700 ConnectX   4  EN   firmware  fw ConnectX4        Device ID For the latest list of device IDs  please visit Mellanox website        Operating System ESXi 2015 operating system        Installer Privileges   The installation requires administrator privileges on the target machine                 4 3 2 Installing VMware        2    Please uninstall any previous                driver packages prior to installing the new ver   sion       2   gt       install the driver   1  Log into the ESXi server with root permissions   2  Install the driver     gt  esxcli software vib install  d  lt path gt   lt bundle file gt   Example     gt  esxcli software vib install  d  lt path gt   lt bundle file gt   3  Reboot the machine     4  Verify the driver was installed successfully       esxcli software vib list   grep mlx  nmlx5 core 4 15 2 0 10EM 600 0 0 2768847 MEL PartnerSupported 2015 09 17    2 After the installation process  all kernel modules are loaded automatically upon boot     5    Mellanox Technologies 43      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      4 3 3 Removing                  OFED Driver        Please unload the driver before removing it     P       To remove all the drivers   1  Log into the ESXi server with root permissions     2  List the existing ConnectX 4 NATIVE ESXi driver modules   see    Installing VMware  on  page 43   3  Remove each module       gt  esxcli software vib remove     nmlx5 core       
35. MOK list using the mokutil utility   You will be asked to enter and confirm a password for this MOK enrollment request     mokutil   import mlnx signing key pub der  Step 3  Reboot the system     The pending MOK key enrollment request will be noticed by shim efi and it will launch Mok   Manager efi to allow you to complete the enrollment from the UEFI console  You will need to  enter the password you previously associated with this request and confirm the enrollment  Once  done  the public key is added to the MOK list  which is persistent  Once a key is in the MOK list   it will be automatically propagated to the system key ring and subsequent will be booted when  the UEFI Secure Boot is enabled        To see what keys have been added to the system key ring on the current boot  install the  keyutils   package and run             1 list    system keyring    Mellanox Technologies 31      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      4 1 8 2 Removing Signature from kernel Modules  The signature can be removed from a signed kernel module using the  strip  utility which is pro   vided by the  binutils  package     strip  g my module ko  The strip utility will change the given file without saving a backup  The operation can be undo    only by resigning the kernel module  Hence  we recommend backing up a copy prior to removing  the signature        Toremove the signature from the MLNX OFED kernel modules   Step 1  Remove the signature     rpm 
36. N CONTRACT  STRICT LIABILITY  OR TORT  INCLUDING NEGLIGENCE OR OTHERWISE   ARISING IN ANY WAY FROM THE USE OF THE PRODUCT S  AND RELATED DOCUMENTATION EVEN IF  ADVISED OF THE POSSIBILITY OF SUCH DAMAGE        Mellanox    TECHNOLOGIES    Mellanox Technologies   350 Oakmead Parkway Suite 100  Sunnyvale  CA 94085   U S A    www mellanox com   Tel   408  970 3400   Fax   408  970 3403       Copyright 2015  Mellanox Technologies  All Rights Reserved     Mellanox    Mellanox logo  BridgeX    CloudX logo  Connect IB    ConnectX    CoolBox    CORE Direct    GPUDirect     InfiniHost    InfiniScale    Kotura    Kotura logo  Mellanox Federal Systems    Mellanox Open Ethernet                    ScalableHPC    Mellanox Connect Accelerate Outperform logo  Mellanox Virtual Modular Switch    MetroDX    MetroX     MLNX OS    Open Ethernet logo  PhyX    SwitchX    TestX    The Generation of Open Ethernet logo  UFM    Virtual  Protocol Interconnect    Voltaire   and Voltaire logo are registered trademarks of Mellanox Technologies  Ltd     Accelio     CyPU     FPGADirect     HPC X     InfiniBridge     LinkXTM  Mellanox Care     Mellanox CloudX     Mellanox  Multi Host     Mellanox NEO                    PeerDirect                    Socket Direct     Mellanox Spectrum     NVMeDirect        StPU     Spectrum logo  Switch IB     Unbreakable Link    are trademarks of Mellanox Technologies  Ltd     All other trademarks are property of their respective owners     2 Mellanox Technologies Document Numb
37. V_00  PCI VEN_15B3 amp DEV_1013 amp SUBSYS_000815B3  PCI VEN_15B3 amp DEV_10138CC_020000  PCI VEN_15B3 amp DEV_10138CC_0200                               5  In the Value display box  check the fields VEN and DEV  fields are separated by     amp       In the  display example above  notice the sub string    PCI VEN 15B3 amp DEV 1003     VEN is equal  to 0x15B3     this is the Vendor ID of Mellanox Technologies  and DEV is equal to 1003     this  is a valid Mellanox Technologies PCI Device ID     If the PCI device does not have a Mellanox adapter ID  return to Step 2 to check  another device     i     The list of Mellanox Technologies PCI Device IDs can be found in the PCI ID reposi   tory at http   pci ids ucw cz read PC 15b3          Mellanox Technologies 19      ConnectX 4 Ethernet Single and Dual        QSFP28 Adapter Card User Manual Rev 1 3      3 7 2 On Linux    Get the device location on the PCI bus by running Ispci and locating lines with the string    Mella   nox Technologies         gt  Ispci   grep  i Mellanox    Network controller  Mellanox Technologies MT4115 Family  ConnectX  41    Mellanox Technologies 20      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      4 Driver Installation    4 1 Linux Driver    For Linux  download and install the latest OpenFabrics Enterprise Distribution  OFED  software  package available via the Mellanox web site at  http   www mellanox com   gt  Products   gt  Soft   ware   gt  Ethernet Drivers   gt
38. X WinOF2 1 21 All x64 exe  5  v  qn    Step 3   Optional  Manually configure your setup to contain the logs option      MLNX WinOF2 1 21 All x64 exe  S  v  qn   v  l vx  LogFile      Step 4   Optional  if you want to control whether to install ND provider or not       MLNX WinOF2 1 21 All win2012 x64 exe  vMT NDPROPERTY 1    Step 5   Optional  If you do not wish to upgrade your firmware version        True   MLNX        WinOF2 1 21 All win2012 x64 exe  v  MT SKIPFWUPGRD 1        1  MT NDPROPERTY default value is True  2  MT SKIPFWUPGRD default value is False    Mellanox Technologies 38      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      Applications that hold the driver files  such      ND applications  will be closed during the unat   tended installation     alll    4 2 4 Installation Results    Upon installation completion  you can verify the successful addition of the network card s   through the Device Manager     Upon installation completion  the inf files can be located at      ProgramFiles  Mellanox MLNX_WinOF2 Drivers  lt OS gt     To see the Mellanox network adapters  display the Device Manager and pull down the            work adapters  menu     Figure 2  Installation Results    File Action View Help      9  mE B m  al 846    4      dev I vrt 058    p      Computer  b      Disk drives  KZ  Display adapters       IDE ATA ATAPI controllers  9 IEEE 1394 host controllers  8  Texas Instruments 1394         Compliant Host Controller 
39. des  c  bles pour conna  tre les mises en garde et les instructions sp  ciales     5  Installation du mat  riel    h Ce mat  riel ne doit   tre install    remplac   ou entretenu que par du personnel form   et  qualifi       6  Elimination du mat  riel    L   limination de      mat  riel doit s   effectuer dans le respect de toutes les l  gislations et  r  glementations nationales en vigueur     7  Codes   lectriques locaux et nationaux    LA Ce mat  riel doit   tre install   dans le respect des codes   lectriques locaux et nationaux     Mellanox Technologies 75    ConnectX 4 Ethernet Single and Dual        QSFP28 Adapter          User Manual Rev 1 3       8  Exposition au rayonnement grave    Mise en garde     l utilisation de commandes ou de r  glages ou l ex  cution de  proc  dures autres que ce qui est sp  cifi   dans les pr  sentes peut engendrer une  exposition au rayonnement grave     PRODUIT LASER DE CLASSE 1    et r  f  rences aux normes laser les plus  r  centes CEI 60 825 1 1993   A1 1997   A2 2001 et NE 60825   1 1994 A1 1996  A2 2001       Mellanox Technologies 76      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      Appendix     Sicherheitshinweise  Warnings    German     1  Installationsanleitungen    Lesen Sie alle Installationsanleitungen  bevor Sie das Gerat an die Stromversorgung  anschlieBen     2  Ubertemperatur    Dieses Ger  t sollte nicht in einem Bereich mit einer Umgebungstemperatur   ber der   AN maximal empfohlen
40. dules    To obtain the list of supported cables for your adapter  please refer to www mellanox com   gt  Prod   ucts   gt  Cables and Transceivers        3 6 1 Cable Installation  1  All cables can be inserted or removed with the unit powered        2  To insert a cable  press the connector into the port receptacle until the connector is firmly  seated     a  Support the weight of the cable before connecting the cable to the adapter card  Do this by using a cable  holder or tying the cable to the rack    b  Determine the correct orientation of the connector to the card before inserting the connector  Do not try and  insert the connector upside down  This may damage the adapter card     c  Insert the connector into the adapter card  Be careful to insert the connector straight into the cage  Do not  apply any torque  up or down  to the connector cage in the adapter card     d  Make sure that the connector locks in place     2 When installing cables make sure that the latches engage             Always install and remove cables by pushing or pulling the cable and connector in     straight line with the card     3  After inserting a cable into a port  the Yellow LED indicator will light when the physical con   nection is established  that is  when the unit is powered on and a cable is plugged into the port  with the other end of the connector plugged into a functioning port   See Section 7 12      Adapter LED Operation     on page 61     4  After plugging in a cable  lock the conn
41. e to browse to a location  Click Install to create     server image of MLNX VPI at the specified network location or click Cancel to exit the  wizard    Network location     NA    InstallShield          Mellanox Technologies 40      ConnectX 4 Ethernet Single and Dual        QSFP28 Adapter Card User Manual Rev 1 3      Step 5  Click Install to extract this folder  or click Change to install to a different folder     Network Location  Specify a network location for the server image of the product        Enter the network location or click Change to browse to a location  Click Install to create a  server image of MLNX_VPI at the specified network location or click Cancel to exit the  wizard     Network location   F A    Change       InstallShield    InstallShield Wizard Completed    The InstallShield Wizard has successfully installed MLNX_VPI   Y Click Finish to exit the wizard        4 2 6 Uninstalling Mellanox WinOF 2 Driver    4 2 6 1 Attended Uninstallation   gt  To uninstall MLNX WinOF2 on a single node     Click Start  gt  Control Panel  gt  Programs and Features  gt  MLNX_WinOF2  gt  Uninstall    NOTE  This requires elevated administrator privileges     Mellanox Technologies 41      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      4 2 6 2 Unattended Uninstallation    If no reboot options are specified  the installer restarts the computer whenever necessary without      4 displaying any prompt      warning to the user         Use the  
42. ec   tory      openshmem            fca and ibutils   e The kernel modules are installed under     lib modules  uname  r  updates on SLES and Fedora Distributions  e  lib modules  uname  r  extra minx ofa kernel on RHEL and other RedHat like   Distributions     lib modules uname  r  updates dkms  on Ubuntu       Firmware   The firmware of existing network adapter devices will be updated if the fol   lowing two conditions are fulfilled     The installation script is run in default mode  that is  without the option      without   fw update         The firmware version of the adapter device is older than the firmware version  included with the Mellanox OFED ISO image  Note  If an adapter   s Flash was originally programmed with an Expansion ROM  image  the automatic firmware update will also burn an Expansion ROM image   e Incase your machine has an unsupported network adapter device  no firmware  update will occur and the error message below will be printed    I  Querying device       E  Can t auto detect fw configuration file       Please contact your hardware vendor for help on firmware updates                 4 1 3 3 Installation Logging    While installing MLNX_OFED  the install log for each selected package will be saved in a sepa   rate log file     The path to the directory containing the log files will be displayed after running the installation  script in the following format   Logs dir   tmp MLNX OFED LINUX  lt version gt   lt PID gt  logs      Example   Logs dir   tm
43. ector using the latching mechanism particular to the  cable vendor  When a logical connection is made the Green LED will light  When data is  being transferred the Green LED will blink  See Section 7 12     Adapter LED Operation     on  page 61     5  Care should be taken as not to impede the air exhaust flow through the ventilation holes  Use  cable lengths which allow for routing horizontally around to the side of the chassis before  bending upward or downward in the rack     6  To remove a cable  disengage the locks and slowly pull the connector away from the port  receptacle  LED indicator will turn off when the cable is unseated     Mellanox Technologies 18      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      3 7 Identify the Card    Your System    3 71 On Windows    1  Open Device Manager on the server  Click start   gt  Run  and then enter  devmgmt msc    2  Expand System Devices and locate your Mellanox ConnectX 4 adapter card     3  Right click the mouse on your adapter s row and select properties to display the adapter card  properties window     4  Click the Details tab and select Hardware Ids  Windows 2012 R2  from the Properties pull   down menu     Figure 1  PCI Device  Example                 Events   Resources   Power Man  General   Advanced   Information   Driver Details                   Mellanox ConnectX 4       Adapter  2   lt      Property    Hardware Ids               Value    PCI VEN_15B38DEV_10138SUBSYS_000815B38RE
44. ellanox Technologies 67    ConnectX 4 Ethernet Single and Dual        QSFP28 Adapter          User Manual Rev 1 3             12C compatible Connector Pinout    Figure 9  Compatible Connector Plug and Pinout                      nn Signal Name  1 GND  2 SCL  3 SDA             Mellanox Technologies 68       ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter          User Manual Rev 1 3    Appendix B  Finding the MAC and Serial Number on the  Adapter Card    Each Mellanox adapter card has a different identifier printed on the label  serial number and the  card MAC for the Ethernet protocol    Figure 10  MCX413A BCAT Board Label    Model No  CX413A  ConnectX 4 40GbE  P N  MCX413A BCAT    2015 10 08           Rev  A4    5           806  01504 put  MAC  00 02 C9 27 05 1C     Made      Israel    Figure 11  MCX414A BCAT Board Label    Model No  CX414A    ConnectX 4 40GbE  PIN  MCX414A BCAT       2015 10 08  INN Rev  a4    S N  MT0806X01504 TEAT  MAC  00 02 C9 27 05 1C     Made    Israel    Figure 12  MCX415A BCAT Board Label    Model No  CX415A    ConnectX 4 40GbE  P N  MCX415A BCAT    2015 10 08         LL Rev  A5            MT0806X01504    MAC  00 02 C9 27 05 1C Tz  Made in Israel                            Mellanox Technologies 69         ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      Figure 13  MCX416A BCAT Board Label  Model No  CX416A    ConnectX 4 40GbE  P N  MCX416A BCAT    2015 10 08                  Rev    6    S N      0806  015
45. en Temperatur von 55  C  131  F  betrieben werden  Es ist ein Luft   strom von 200 LFM bei maximaler Umgebungstemperatur erforderlich  Au  erdem  sollten mindestens 8 cm  3 in   Freiraum um die Bel  ftungs  ffnungen sein  um einen  einwandfreien Luftstrom zu gew  hrleisten     3  Bei Gewitter   Elektrische Gefahr    Arbeiten Sie w  hrend eines Gewitters und Blitzschlag nicht am Ger  t  schlie  en Sie  keine Kabel an oder ab     4  Anschlie  en Trennen von  Kupferkabel    Kupferkabel sind schwer und nicht flexible  Deshalb m  ssen sie vorsichtig an die  LA Anschl  sse angebracht bzw  davon getrennt werden  Lesen Sie die speziellen Warnun   gen und Anleitungen des Kabelherstellers     5  Ger  teinstallation    Diese Ger  t sollte nur von geschultem und qualifiziertem Personal installiert  aus   getauscht oder gewartet werden     6  Ger  teentsorgung    Die Entsorgung dieses Ger  ts sollte unter Beachtung aller nationalen Gesetze Bestim   A mungen erfolgen     7  Regionale und nationale elektrische Bestimmungen t    Dieses Ger  t sollte unter Beachtung der regionalen und nationalen elektrischen Bes   timmungen installiert werden     This equipment should be installed in compliance with local and national elec     LA trical codes     Mellanox Technologies 77    ConnectX 4 Ethernet Single and Dual        QSFP28 Adapter          User Manual Rev 1 3       8  Strahlenkontak    Achtung     Nutzung von Steuerungen oder Einstellungen oder Ausf  hrung von  Prozeduren  die hier nicht spez
46. er  MLNX 15 5583      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      Table of Contents    Table of Contents sn m war ome Ro Re      e a Le fec a cn ic  List ob Tables arr a RTI RG EORR CR               eee                Last OF 1065 EE NUERA RA AT  Revision History ars      About this Manual    soe Cesc sae Me                        Intended  Audience       2                     petet eee qu eb epus 9   Related Documentation                                                    9   Document Conventions    i                     10   Technical                ete ue E E MEE DAN IR EX TM 10   Firmware Updates                                                       10   Chapter 1 Introduction         ll  1  Product  Overview ier e a ede ERE      er HET US 11   1 2     Features and Benefits      2 aaa DL dus aedes aes 13   1 3 Operating Systems Distributions                                       14   1 4     Connectivity asco ei    bie ek                                          ees 14   Chapter 2  Interface er ne DD  2 1 Ethernet QSFP28 Interface                                           15   2 2  IPCI Express Interface ru       du ann LINGEN 15   2 2  I2C compatible Interface              ann 15   274  BED Interface Li 3                   een ke eR 15   Chapter 3 Hardware                                                                16  3 1  System Requirements  ru    ee        wean es ae 16   3 1 1                                     Se       
47. ernet Drivers   gt  Windows SW Driver   gt  Download  Follow the installation instructions  included in the download package  also available from the download page      4 2 1 Hardware and Software Requirements    Table 7   Hardware and Software Requirements                   Description  Package  Windows Server 2012 R2  64 bit only  MLNX WinOF2 1 21 All x64 exe  Windows Server 2012  64 bit only  MLNX WinOF2 1 21 All x64 exe          a  The Operating System listed above must run with administrator privileges     4 2 2 Downloading Mellanox WinOF 2 Driver  To download the  exe according to your Operating System  please follow the steps below   Step 1  Obtain the machine architecture   For Windows Server 2012   2012 R2  1  To go to the Start menu  position your mouse in the bottom right corner of the  Remote Desktop of your screen   2  Open a CMD console  Click Task Manager    gt File    gt  Run new task  and enter  CMD    3  Enter the following command    gt  echo  PROCESSOR ARCHITECTURES    On an x64  64 bit  machine  the output will be  AMD64      Step 2  Go to the Mellanox WinOF 2 web page at   http   www mellanox com   gt  Products   gt  Ethernet   gt  Windows SW Drivers     Step 3  Download the  exe image according to the architecture of your machine  see Step 1    The  name of the  exe is in the following format  MLNX_WinOF2  lt version gt _ lt arch gt  exe       Installing the incorrect  exe file is prohibited  If you do so  an error message will be dis       played  For 
48. example  if you try to install a 64 bit  exe on a 32 bit machine  the wizard  will display the following  or a similar  error message        This installation package is not supported by this  processor type  Contact your product vendor     OK       Mellanox Technologies 33      ConnectX 4 Ethernet Single and Dual        QSFP28 Adapter Card User Manual Rev 1 3      4 2 3 Installing Mellanox WinOF 2 Driver    This section provides instructions for two types of installation procedures   e    Attended Installation       An installation procedure that requires frequent user intervention        Unattended Installation       An automated installation procedure that requires no user intervention     Both Attended and Unattended installations require administrator privileges     4 2 3 1 Attended Installation  The following is an example of an installation session   Step 1  Double click the  exe and follow the GUI instructions to install MLNX WinOF2     Step 2   Optional  Manually configure your setup to contain the logs option    gt  MLNX WinOF2 1 21 All x64 exe  v  l vx  LogFile      Step 3   Optional  If you do not want to upgrade your firmware version        MLNX VPI WinOF 1 21 All win2012 x64 exe  v  MT SKIPFWUPGRD 1   Step 4  Click Next in the Welcome screen     Welcome to the InstallShield Wizard for  MLNX WinOF2    The InstallShield R  Wizard will install MLNX  WinOF2 on your  computer  To continue  dick Next     WARNING  This program is protected by copyright law and  interna
49. g of the Dual port Adapter Card on page 61 for the location on the board     2 4 LED Interface    There is a one bi color I O LED per port  For LED specifications  please refer to Section 7 12      Adapter LED Operation     on page 61     Mellanox Technologies 15      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      3 Hardware Installation  3 1 System Requirements    3 1 1 Hardware    A system with a PCI Express x16 or x8 slot is required for installing the card     3 1 2 Operating Systems Distributions    Please refer to Section 1 3     Operating Systems Distributions     on page 14     3 1 3 Software Stacks    Mellanox OpenFabric software package MLNX OFED for Linux  WinOF 2 for Windows and  VMware  See Chapter 4    Driver Installation    on page 21     3 2 Safety Precautions    The adapter is being installed in a system that operates with voltages that can be lethal   Before opening the case of the system  observe the following precautions to avoid  injury and prevent damage to system components     Remove any metallic objects from your hands and wrists   Make sure to use only insulated tools     Verify that the system is powered off and is unplugged          It is strongly recommended to use an ESD strap or other antistatic devices     3 3 Pre installation Checklist    1  Verify that your system meets the hardware and software requirements stated above   2  Shut down your system if active    3  After shutting down the system  turn off 
50. gt  iso   You can download it from http   www mellanox com   gt  Products   gt  Software   gt  Ether   net Drivers     Step 3  Use the md5sum utility to confirm the file integrity of your ISO image  Run the following  command and compare the result to the value provided on the download page     host1  md5sum MLNX OFED LINUX   ver     OS label gt  iso    Mellanox Technologies 21      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      4 1 3 Installing Mellanox             The installation script  minxofedinstal1l  performs the following   e Discovers the currently installed kernel      Uninstalls any software stacks that are part of the standard operating system distribution  or another vendor s commercial stack    e Installs the MLNX OFED LINUX binary RPMs  if they are available for the current  kernel       Identifies the currently installed Ethernet network adapters and automatically  upgrades  the firmware    Usage    mnt mlnxofedinstall  OPTIONS     The installation script removes all previously installed Mellanox OFED packages and re installs  from scratch  You will be prompted to acknowledge the deletion of the old packages        Pre existing configuration files will be saved with the extension     conf rpmsave              e If you need to install Mellanox OFED on an entire  homogeneous  cluster  a common  strategy is to mount the ISO image on one of the cluster nodes and then copy it to a  shared file system such as NFS  To install o
51. ifiziert sind  kann zu gef  hrlichem Strahlenkon   takt f  hren      Klasse 1 Laserprodukt und Referenzen zu den aktuellsten Lasterstandards    ICE 60 825 1 1993   A1 1997   A2 2001 und EN 60825 1 1994 A1 1996   A2 2001       Mellanox Technologies 78      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      Appendix     Advertencias de seguridad para la insta   lacion  Warnings in Spanish     1  Instrucciones de instalaci  n    Antes de conectar el equipo a la fuente de alimentacion  leer todas las instrucciones de  instalacion     2  Sobrecalentamiento    No se debe utilizar el equipo en un area con una temperatura ambiente superior a la   LA maxima recomendada  55  C 131  F   Ademas  para garantizar una circulacion de aire  adecuada  se debe dejar como minimo un espacio de 8 cm  3 pulgadas  alrededor de las  aberturas de ventilacion     3  Cuando hay rayos  peligro de descarga el  ctrica    No utilizar el equipo ni conectar o desconectar cables durante periodos de actividad de                    4  Conexi  n y desconexi  n del cable Copper    Dado que los cables de cobre son pesados y no son flexibles  su conexi  n a los conec   LA tores y su desconexion se deben efectuar con mucho cuidado  Para ver advertencias     instrucciones especiales  consultar al fabricante del cable     5  Instalaci  n de equipos    La instalaci  n  el reemplazo y el mantenimiento de este equipo estar  n a cargo   nica   mente de personal capacitado y competente    
52. iption    and latency over various  configurations  Network Direct   InfiniBand     This feature requires 496KB on  your hard drive                 Install to   C  Program Files  Mellanox MLNX_WinOF2 Performance tools  Change       InstallShield          b  Click Install to start the installation     Ready to Install the Program  The wizard is ready to begin installation        Click Install to begin the installation     If you want to review or change any of your installation settings  click Back  Click Cancel to  exit the wizard     InstallShield          Mellanox Technologies 37      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      Step 9  Click Finish to complete the installation       MLNX_WinOF2   InstallShield Wizard Lx            InstallShield Wizard Completed    The InstallShield Wizard has successfully installed  MLNX_WinOF2  Click Finish to exit the wizard      C  Show release notes          4 2 3 2 Unattended Installation    displaying any prompt or warning to the user               7 If no reboot options are specified  the installer restarts the computer whenever necessary without       Use       norestart       forcerestart standard command line options to control reboots     The following is an example of an unattended installation session     Step 1  Open a CMD console  Windows Server 2012 R2    Click Start    gt  Task Manager   gt File    gt   Run new task    gt  and enter CMD     Step 2  Install the driver  Run    gt  MLN
53. make tgz   Note  This program will create MLNX OFED LINUX TGZ for rhel6 3 under  tmp directory   All Mellanox  OEM  OFED  or Distribution IB packages will be removed    Do you want to continue   y N  y   See log file  tmp mlnx ofed 180 21642 104       Building OFED RPMs  Please wait     Removing OFED RPMs     Created  tmp MLNX OFED LINUX x x x rhel6 3 x86 64 ext tgz      The script adds the following lines to  etc security limits conf for the userspace  components such as MPI         soft memlock unlimited      hard memlock unlimited      These settings set the amount of memory that can be pinned by a user space application to unlimited  If  desired  tune the value unlimited to a specific amount of RAM     4 1 3 1 Installation Procedure  Step 1  Login to the installation machine as root   Step 2  Mount the ISO image on your machine   host1  mount  o ro loop MLNX OFED LINUX   ver     0S label gt   lt CPU arch gt  iso  mnt    Step3  Run the installation script       mnt mlnxofedinstall  Logs dir   tmp MLNX OFED LINUX x x x logs   This program will install the MLNX OFED LINUX package on your machine    Note that all other Mellanox  OEM  OFED  or Distribution IB packages will be removed   Uninstalling the previous version of MLNX OFED LINUX          Starting MLNX OFED LINUX x x x installation        Installation finished successfully     Attempting to perform Firmware update     Querying Mellanox devices firmware        Mellanox Technologies 23      ConnectX 4 Ethernet Single and
54. n all the cluster nodes  use cluster aware  tools  such as pdsh      e If your kernel version does not match with any of the offered pre built RPMs  you can  add your kernel version by using the    mlnx_add_kernel_support sh    script located  under the docs  directory     On Redhat and SLES distributions with errata kernel installed there is no need to use the  minx add kernel support sh script  The regular installation can be performed and weak   a  updates mechanism will create symbolic links to the MLNX OFED kernel modules     The  minx add kernel support  sh    script can be executed directly from the minxofedinstall  script  For further information  please see     add kernel   support   option below       On Ubuntu and Debian distributions drivers installation use Dynamic Kernel Module     4 Support  DKMS  framework  Thus  the drivers  compilation will take place on the host  during MLNX_OFED installation    os Therefore  using  mlnx_add_kernel_support sh  is irrelevant on Ubuntu and  Debian distributions        1  The firmware will not be updated if you run the install script with the    without fw update    option     Mellanox Technologies 22      ConnectX 4 Ethernet Single and Dual        QSFP28 Adapter Card User Manual Rev 1 3      Example    The following command will create    MLNX OFED LINUX ISO image for RedHat 6 3 under  the  tmp directory         MLNX OFED LINUX x x x rhel6 3 x86 64 mlnx add kernel support sh  m  tmp MLNX OFED    LINUX x x x rhel6 3 x86 64    
55. nnector Pin Name Port A Signal Name   1 GND GND   2 TXN_2 Tx2n   3 TXP_2 Tx2p   4 GND GND   5 TXN_4 Tx4n   6 TXP_4 Tx4p   7 GND GND   8 ModSelL_Port0 ModSelL  9 ResetL_Port0 ResetL  10             11 SCL SCL  12 SDA SDA  13 GND GND  14        3 Rx3p  15 RXN_3 Rx3n       Mellanox Technologies 64      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      Table 20   Connector Pin Number and Name to Signal Name                                                                                   Connector Pin Number Connector Pin Name Port A Signal Name  16 GND GND  17 RXP_1 Rx1p  18 RXN 1          19 GND GND  20 GND GND  21 RXN 2 Rx2n  22 RXP 2 Rx2p  23 GND GND  24 RXN 4 Rx4n  25 RXP 4 Rx4p  26 GND GND  27 ModPrsl PortO Mod PrsL  28 IntL IntL  29             30       1  31 LPMode        0 LPMode  32 GND GND  33 TXP 3 Tx3p  34 TXN 3 Tx3n  35 GND GND  36        1           37        1           38 GND GND                   Mellanox Technologies 65      ConnectX 4 Ethernet Single and Dual        QSFP28 Adapter Card User Manual Rev 1 3         2    Mellanox Technologies 66    PCI Express x8 or x16 Connector Pinout    The adapter cards use a standard PCI Express x8 orx16 edge connector and the PCI Express x8 or    x16 standard pinout according to the PCI Express 3 0 specification     61    ol   vol ol ol         Figure 7  PCle x8 Connector Pinout          P12V_AUX 1  P12V AUX 2  P12V AUX 3  GND 26  GND 27  P3V3 AUX 2  GND 28  GND 29  P3V3 5  P3V3 6  P3V3 7
56. norestart or  forcerestart standard command line options to control reboots      gt  To uninstall MLNX WinOF2 in unattended mode     Step 1  Open a CMD console  Windows Server 2012 R2    Click Start    gt  Task Manager    gt File    gt   Run new task    gt  and enter CMD     Step 2  Uninstall the driver  Run    gt  MLNX WinOF2 1 21 All win2012 x64 exe  S  x  v  qn     42 7 Firmware Upgrade    If the machine has a standard Mellanox card with an older firmware version  the firmware will be  automatically updated as part of the WinOF 2 package installation    For information on how to upgrade firmware manually  please refer to MFT User Manual   http   www mellanox com page management_tools       Mellanox Technologies 42      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      4 3 VMware Driver    For VMware  download and install the latest Mellanox ConnectX 4 NATIVE ESXi Driver for  VMware vSphere software package available via the Mellanox web site at  http   www mella   nox com   gt  Products   gt  Adapter Ethernet SW   gt  Download  This chapter describes how to  install and test Mellanox ConnectX 4 NATIVE ESXi Driver for VMware vSphere on a single  host machine with Mellanox Ethernet adapter hardware installed     4 3 1 Hardware and Software Requirements    Table 8   Hardware and Software Requirements       Requirements Description       Platforms A server platform with an adapter card based on one of the following Mellanox  Technologies    
57. nual      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      This User Manual describes                Technologies ConnectX   4 Ethernet Single and Dual  QSFP28 port PCI Express x8 and x16 adapter cards  It provides details as to the interfaces of the  board  specifications  required software and firmware for operating the board  and relevant docu     mentation     Intended Audience    This manual is intended for the installer and user of these cards     The manual assumes basic familiarity with Ethernet network and architecture specifications     Related Documentation    Table 2   Documents List       Mellanox Firmware Tools  MFT  User  Manual  Document no  2204UG    User Manual describing the set of MFT firmware management  tools for a single node    See http   www mellanox com   gt  Products   gt  Software   gt  Firm   ware Tools          Mellanox Firmware Utility  mlxup  User  Manual and Release Notes    Mellanox firmware update and query utility used to update the  firmware  See http   www mellanox com   gt    Products   gt  Software   gt  Firmware Tools   gt  mlxup Firmware  Utility          Mellanox OFED for Linux  User Manual  Document no  2877    User Manual describing OFED features  performance  Band diag   nostic  tools content and configuration See http   www mella   nox com   gt  Products   gt  Software   gt  Ethernet Drivers  gt   Mellanox OpenFabrics Enterprise Distribution for Linux  MLNX   _OFED           WinOF 2 for Window
58. ol Support    0GBASE KR  SGMII       Data Rate  1 10 25 40 50 Gb s    Ethernet       PCI Express Gen3  SERDES   8 0GT s  16 lanes  2 0 and 1 1 compatible        Voltage  12V  3 3V       Power and Temperature  Operational 0  C to 55  C  Environmental Non operational  40  C to 70  C       Humidity  90  relative humidity        Safety  CB   cTUVus   CE       Regulatory                FCC   VCCI   ICES   RCM                RoHS  RoHS R6       a  For both operational and non operational states     Mellanox Technologies 56      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      78   MCX416A GCAT Specifications  Table 16   MCX416A GCAT Specifications Table    Size  2 71 in  x 5 6 in   68 90mm x 142 24 mm      low profile       Physical  Connector  Dual QSFP28  Copper and optical        Ethernet  50GBASE R2  50GBASE R4  40GBASE CR4  40GBASE KR4   40GBASE SR4  40GBASE LR4  40GBASE ER4  40GBASE R2  25GBASE R   20GBASE KR2  1000BASE CX  1000BASE KX  10GBASE SR  10GBASE   LR 10GBASE ER  10GBASE CX4  10GBASE KX4  I0GBASE CR    Protocol Support    0GBASE KR  SGMII       Data Rate  1 10 25 40 50 Gb s     Ethernet       PCI Express Gen3  SERDES   8 0GT s  16 lanes  2 0 and 1 1 compatible        Voltage  12V  3 3V       Typical Power     Passive Cables  14 19W       Maximum Power  Passive Cables  16 00W  3 5W Active Cables  23 78       Power and       Maximum power available through QSFP28 port  3 5W  Environmental       Temperature  Operational 0 C to 55  C
59. onnectivity    Interoperable 1 10 25 40 50 100 Gb s Ethernet switches      Passive copper cable with ESD protection      Powered connectors for optical and active cable support    Mellanox Technologies 14      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      2 Interfaces    Each adapter card includes the following interfaces        Ethernet QSFP28 Interface         PCI Express Interface    e   2C compatible Interface         LED Interface     The adapter cards include special circuits to protect from ESD shocks to the card server when  plugging copper cables     2 1 Ethernet QSFP28 Interface    The network ports of the ConnectX   4 adapter card are compliant with the IEEE 802 3 Ethernet  standards listed in Table 4     Features     on page 13  Ethernet traffic is transmitted through the  cards  QSFP28 connectors     2 2 PCI Express Interface    The ConnectX   4 adapter card supports PCI Express 3 0  1 1 and 2 0 compatible  through an  x8 x16 edge connector  The device can be either a master initiating the PCI Express bus opera   tions  or a slave responding to PCI bus operations  The following lists PCIe interface features     e PCIe Gen 3 0 compliant  1 1 and 2 0 compatible      2 5  5 0  or 8 0 GT s link rate x8 x16     Auto negotiates to x16  x8  x4  x2  or x1     Support for MSI MSI X mechanisms    23   C compatible Interface    A three pin header on the adapter cards is provided as the PC compatible interface  See Mechan   ical Drawin
60. ort QSFP28 Adapter Card User Manual Rev 1 3    74   MCX416A BCAT Specifications    Table 12         416            Specifications Table    Size  2 71 in  x 5 6 in   68 90mm x 142 24 mm      low profile       Physical  Connector  Dual QSFP28  Copper and optical        Ethernet  40GBASE CR4  40GBASE KR4  40GBASE SR4  40GBASE LR4   40GBASE ER4  40GBASE R2  25GBASE R  20GBASE KR2  1000BASE CX   1000BASE KX  10GBASE SR  10GBASE LR 10GBASE ER  10GBASE CX4   Protocol Support    0GBASE KX4  10GBASE CR  10GBASE KR  SGMII       Data Rate  1 10 25 40 Gb s     Ethernet       PCI Express Gen3  SERDES   8 0GT s  16 lanes  2 0 and 1 1 compatible        Voltage  12V  3 3V       Typical Power     Passive Cables  14 95W       Maximum Power  Passive Cables  16 69W  1 5W Active Cables  20 02W       Power and      Maximum power available through QSFP28 port  3 5W  Environmental       Temperature  Operational 0 C to 55  C  Non operational  40  C to 70  C       Humidity  90  relative humidity        Air Flow  See Airflow Specifications on page 60       Safety  CB   cTUVus   CE2       Regulatory                         VCCI   ICES   RCM       RoHS  RoHS R6                a  Typical power for ATIS traffic load   b  For both operational and non operational states     Mellanox Technologies 53      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      75   MCX413A GCAT Specifications  Table 13   MCX413A GCAT Specifications Table    Size  2 71 in  x 5 6 in   68 90mm x 142 
61. p MLNX OFED LINUX x x x logs    4 1 3 4 openibd Script  As of MLNX OFED v2 2 1 0 0 the openibd script supports pre post start stop scripts     This can be controlled by setting the variables below in the  etc band openibd conf file     OPENIBD PRE START  OPENIBD POST START  OPENIBD PRE STOP  OPENIBD POST STOP    Example                 OPENIBD POST START  sbin openibd post start sh    4 1 3 5 Driver Load Upon System Boot    Upon system boot  the Mellanox drivers will be loaded automatically     Mellanox Technologies 25      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3       gt  To prevent automatic load of the Mellanox drivers upon system boot   Step 1  Add the following lines to the   etc modprobe d mlnx conf  file     blacklist mlx4_core  blacklist mlx4 en  blacklist mlx5 core  blacklist mlx5 ib    Step 2  Set    ONBOOT no  in the   etc band openib conf  file     4 1 3 6 minxofedinstall Return Codes    Table 6 lists the mInxofedinstall script return codes and their meanings     Table 6   minxofedinstall Return Codes                               Return Code Meaning   0 The Installation ended successfully   1 The installation failed   2 No firmware was found for the adapter device   22 Invalid parameter   28 Not enough free space   171 Not applicable to this system configuration  This can occur  when the required hardware is not present on the system    172 Prerequisites are not met  For example  missing the required  software installed or
62. p yyyymmdd  log    Mellanox Technologies 46      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      6    6 1    Mellanox Technologies 47    Troubleshooting    General             Server unable to find  the adapter    Ensure that the adapter is placed correctly   Make sure the adapter slot and the adapter are compatible   Install the adapter in a different PCI Express slot   Use the drivers that came with the adapter or download the latest  Make sure your motherboard has the latest BIOS   Try to reboot the server          The adapter no longer  works    Reseat the adapter in its slot or a different slot  if necessary  Try using another cable    Reinstall the drivers for the network driver files may be damaged  or deleted    Reboot the server          Adapters stopped  working after  installing another  adapter    Try removing and re installing all adapters  Check that cables are connected properly  Make sure your motherboard has the latest BIOS          Link indicator light is    Ensure that adapter driver s is loaded  Try another port on the switch  Make sure the cable is securely attached                   off Check your are using the proper cables that do not exceed the rec   y 8   ommended lengths  Verify that your switch and adapter port are compatible   Link light is on  but Check that the latest driver is loaded   with no Check that both the adapter and its link are set to the same speed  communication and duplex settings  established 
63. power and unplug the cord    4      Remove the card from its package  Please note that the card must be placed on an antistatic  surface     5  Check the card for visible signs of damage  Do not attempt to install the card if damaged     3 4 Bracket Installation Instructions    The card is usually shipped with a tall bracket installed  If this form factor is suitable for your  requirements  you can skip the remainder of this section and move to Section 3 5     Card Installa   tion Instructions     on page 17  If you need to replace it with the short bracket that is included in  the shipping box  please follow the instructions in this section     Due to risk of damaging the EMI gasket  it is not recommended to replace the bracket     more than three times     Mellanox Technologies 16      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3           replace the bracket you will need the following parts     The new bracket of the proper height      The 2 screws saved from the removal of the bracket    e The 2 fiber washers saved from the removal of the bracket    3 41 Removing the Existing Bracket    1  Remove the two screws holding the bracket in place  The bracket comes loose from the card     LA Be careful not to put stress on the LEDs     2  Save the two screws and the two fiber washers     3 4 2 Installing the New Bracket    1  Place the bracket onto the card until the screw holes line up     Do not force the bracket onto the card  You may have
64. reduces application run  time  ConnectX 4 advanced acceleration technology enables higher cluster effi   ciency and scalability to tens of thousands of nodes     Mellanox Technologies 13      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      Table 4   Features     Adapter functionality enabling reduced CPU overhead allowing more available    CPU offload CPU for computation tasks     Support for port based Quality of Service enabling various application require     Quality of Service  908  ments for latency and SLA    Hardware based I O ConnectX 4 provides dedicated adapter resources and guaranteed isolation and  Virtualization protection for virtual machines within the server     A consolidated compute and storage network achieves significant cost perfor   Storage Acceleration mance advantages over multi fabric networks  Standard block and  file access protocols can leverage RDMA for high performance storage access     ConnectX 4 SR IOV technology provides dedicated adapter resources and    ey guaranteed isolation and protection for virtual machines  VM  within the server     a  This section describes hardware features and capabilities  Please refer to the driver release notes for feature availability  See  Table 2     Documents List     on page 9        1 3 Operating Systems Distributions    RHEL CentOS      Windows     FreeBSD     VMware     OpenFabrics Enterprise Distribution  OFED    e OpenFabrics Windows Distribution  WinOF 2     1 4 C
65. s  User Manual  Document no  MLX 15 3280    User Manual describing WinOF 2 features  performance  Ethernet  diagnostic  tools content and configuration  See http   www mella   nox com     Products   gt  Software   gt  Windows SW Drivers          Mellanox OFED for Windows Driver  Release Notes    Release notes for                Technologies MLNX_EN for Linux  driver kit for Mellanox adapter cards  See http   www mella   nox com   gt  Products   gt  Software   gt  Ethernet Drivers     gt  Mellanox OFED for Windows   gt  WinOF 2 Release Notes          Mellanox EN for Linux Driver Release  Notes    Release notes for                Technologies MLNX_EN for Linux  driver kit for Mellanox adapter cards  See http   www mella   nox com   gt  Products   gt  Software   gt  Ethernet   Drivers   gt  Mellanox EN for Linux          Mellanox VMware for Ethernet User Man   ual  Document no  MLNX 15 4896          User Manual describing the various components of the Mellanox  ConnectX   4 NATIVE ESXi stack  See   gt  http   www mella   nox com Products   gt  Software   gt  Ethernet Drivers   gt  VMware  Driver   gt  User Manual v4 15 2 0          Mellanox Technologies 9         ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      Mellanox VMware for Ethernet Release Release notes for Mellanox ConnectX   4 NATIVE ESXi stack   Notes See   gt  http   www mellanox com Software   gt  Ethernet Drivers    gt  VMware Driver   gt  Release Notes             IEEE Std 802 
66. security  subscription manager  This system is not registered to Red Hat Subscription Management  You can use subscrip        tion manager to register   Setting up Group Process  Resolving Dependencies       Running transaction check        Package ar mgr x86 64 0 1 0 0 11 g22fff4a will be installed    rds devel x86 64 0 2 0 6mlnx 1   rds tools x86 64 0 2 0 6mlnx 1   srptools x86 64 0 0 0 4mlnx3 OFED 2 0 2 6 7 11 ge863cb7  Complete     Installing MLNX OFED using the YUM tool does not automatically update the firmware   To update the firmware to the version included in MLNX OFED package  you can either     Mellanox Technologies 28      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3                      mInxofedinstall script with the    fw update only  flag  or      Update the firmware to the latest version available on Mellanox Technologies    Web site  as described in Chapter 5    Updating Adapter Card Firmware    on page 46     4 1 5 3 Uninstalling Mellanox OFED using the YUM Tool  If MLNX_OFED was installed using the yum tool  then it can be uninstalled as follow   yum groupremove   lt group name            The    group name gt     must be the same group name that was previously used to install  MLNX OFED     4 1 6 Installing MLNX OFED using apt get  This type of installation is applicable to Debian and Ubuntu Operating Systems     4 1 6 1 Setting up MLNX OFED apt get Repository  Step 1  Log into the installation machine as root   Step2  E
67. those specified herein may result in hazardous radiation exposure        Mellanox Technologies 73          ConnectX 4 Ethernet Single and Dual        QSFP28 Adapter          User Manual Rev 1 3    CLASS 1 LASER PRODUCT and reference to the most recent laser standards          60 825 1 1993     1 1997     2 2001 and EN 60825 1 1994 A 1 1996   A2 20     Mellanox Technologies 74      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      Appendix D  Avertissements de s  curit   d   installation   Warnings in French     1  Instructions d   installation    Lisez toutes les instructions d   installation avant de brancher le mat  riel    la source  d   alimentation   lectrique     2  Temp  rature excessive    Ce materiel ne doit pas fonctionner dans une zone avec une temp  rature ambiante   LA d  passant le maximum recommand   de 55  C  131  F   Un flux d   air de 200LFM     cette temp  rature ambiante maximale est n  cessaire  En outre  pour garantir un bon    coulement de l   air  laissez au moins 8 cm  3 pouces  d   espace libre autour des ouver   tures de ventilation     3  Orages   dangers   lectriques    Pendant un orage  il ne faut pas utiliser le mat  riel et il ne faut pas brancher ou  d  brancher les c  bles     4  Branchement d  branchement des c  bles en cuivre    Les c  bles en cuivre sont lourds et ne sont pas flexibles  il faut donc faire tr  s attention  LA en les branchant et en les d  branchant des connecteurs  Consultez le fabricant 
68. tional 0  C to 55  C  Non operational  40  C to 70  C       Humidity  90  relative humidity        Air Flow  See Airflow Specifications on page 60       Safety  CB   cTUVus   CE2       Regulatory                         VCCI   ICES   RCM             RoHS  RoHS R6          a  Typical power for ATIS traffic load   b  For both operational and non operational states     Mellanox Technologies 51      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3    7 3        415            Specifications    Table 11   MCX415A BCAT Specifications Table    Size  2 71 in  x 5 6 in   68 90mm x 142 24 mm      low profile  Physical       Connector  Single QSFP28  Copper and optical        Ethernet  40GBASE CR4  40GBASE KR4  40GBASE SR4  40GBASE LR4   40GBASE ER4  40GBASE R2  25GBASE R  20GBASE KR2  1000                1000BASE KX  10GBASE SR  10GBASE LR  10GBASE ER  10GBASE CX4   Protocol Support    0GBASE KX4  10GBASE CR  10GBASE KR  SGMII       Data Rate  1 10 25 40 Gb s     Ethernet       PCI Express Gen3  SERDES   8 0GT s  16 lanes  2 0 and 1 1 compatible        Voltage  12V  3 3V       Power and Temperature  Operational 0  C to 55  C  Environmental Non operational  40  C to 70  C       Humidity  90  relative humidity        Safety         cTUVus   CE       Regulatory                         VCCI   ICES   RCM             RoHS  RoHS R6          a  For both operational and non operational states     Mellanox Technologies 52      ConnectX 4 Ethernet Single and Dual P
69. tional treaties           1  MT SKIPFWUPGRD default value is False    Mellanox Technologies 34      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      Step 5  Read then accept the license agreement and click Next     Please read the following license agreement carefully        Copyright  c  2005 2015  Mellanox Technologies All    rights reserved        Redistribution and use in source and binary forms  with  or without modification  are permitted provided that the  following conditions are met     Redistributions of source code must retain the above  copyright notice  this list of conditions and the  following disclaimer          mms mises nnna in hinas Fawr mmm mannadnan tha nahara    O L accept the terms in the license agreement   8  I do not accept the terms in the license agreement    v    InstallShield           m                    Step 6  Select the target folder for the installation     Destination Folder  Click Next to install to this folder  or click Change to install to a differer       Install MLNX_WinOF2 to   C  Program Files Mellanox MLNX_WinOF2     InstallShield          Mellanox Technologies 35      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3             7  The firmware upgrade screen will be displayed in the following cases     Ifthe user has an OEM card  In this case  the firmware will not be displayed       Ifthe user has a standard Mellanox card with an older firmware version  the firm
70. tions                   quel Once installed  open a CMD window and run   cd C  Program Files Mellanox WinMFT  mst start  mst status  flint  d  lt mst_device gt      Ports Information vstat          Download the latest firmware version using the PSID board ID   http   www mellanox com supportdownloader   flint  d  lt mst_device gt     1  lt firmware_bin_file gt  b    Firmware Version  Upgrade                Event log viewer     MST device logs     mst start   Collect log file     mst status      C  Users Administrator gt  flint  d  lt mst_device gt  dc  gt  dump con   figuration  log      C  Users Administrator gt  mstdump  lt mst_device gt  dc  gt  mst   dump log                            Mellanox Technologies 49      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3    7 Specifications    71   MCX413A BCAT Specifications  Table 9   MCX413A BCAT Specifications Table    Size  2 71 in  x 5 6 in   68 90mm x 142 24 mm      low profile       Physical  Connector  Single QSFP28  Copper and optical        Ethernet  40GBASE CR4  40GBASE KR4  40GBASE SR4  40GBASE LR4   40GBASE ER4  40GBASE R2  25GBASE R  20GBASE KR2  1000BASE CX   1000BASE KX  10GBASE SR  I0GBASE LR  10GBASE ER  10GBASE CX4   Protocol Support   10GBASE KX4  10GBASE CR  10GBASE KR  SGMII       Data Rate  1 10 25 40 Gb s     Ethernet       PCI Express Gen3  SERDES   8 0GT s  8 lanes  2 0 and 1 1 compatible        Voltage  12V  3 3V       Typical Power     Passive Cables  10 18W       Maxim
71. tmp mlnx ofed repo  etc yum repos d     Mellanox Technologies 27      ConnectX 4 Ethernet Single and Dual        QSFP28 Adapter Card User Manual Rev 1 3      Step 9  Check that the repository was successfully added       yum repolist   Loaded plugins  product id  security  subscription manager   This system is not registered to Red Hat Subscription Management  You can use subscrip   tion manager to register     repo id repo name status  mlnx ofed MLNX OFED Repository 108  rpmforge RHEL 6Server   RPMforge net   dag 217591    repolist  8 351    4 1 5 2 Installing MLNX_OFED using the YUM          After setting up the YUM repository for MLNX_OFED package  perform the following   Step 1  View the available package groups by invoking       yum grouplist   grep MLNX           LNX OFED ALL   LNX OFED BASIC   LNX OFED GUEST   LNX OFED HYPERVISOR   LNX OFED VMA   LNX OFED VMA ETH   LNX OFED VMA VPI                                        Where   LNX OFED ALL Installs all available packages in MLNX OFED   LNX OFED BASIC Installs basic packages required for running Mellanox cards   LNX OFED GUEST Installs packages required by guest OS   LNX OFED HYPERVISOR Installs packages required by hypervisor OS   LNX OFED VMA Installs packages required by VMA   LNX OFED VMA ETH Installs packages required by VMA to work over Ethernet   LNX OFED VMA VPI Installs packages required by VMA to support VPI   Step 2  Install the desired group     yum groupinstall  MLNX OFED ALL   Loaded plugins  product id  
72. um Power  Passive Cables  11 79W  1 5W Active Cables  13 45W       Power and      Maximum power available through QSFP28 port  3 5W  Environmental       Temperature  Operational 0 C to 55  C  Non operational  40  C to 70  C       Humidity  90  relative humidity        Air Flow  See Airflow Specifications on page 60       Safety  CB   cTUVus   CE2       Regulatory                FCC   VCCI   ICES   RCM       RoHS  RoHS R6             a  Typical power for ATIS traffic load   b  For both operational and non operational states     Mellanox Technologies 50      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      72   MCX414A BCAT Specifications  Table 10         414            Specifications Table    Size  2 71 in  x 5 6 in   68 90mm x 142 24 mm      low profile  Physical       Connector  Dual QSFP28  Copper and optical        Ethernet  40GBASE CRA  40GBASE KR4  40GBASE SR4  40GBASE LR4   40GBASE ER4  40GBASE R2  25GBASE R  20GBASE KR2  1000                1000BASE KX  10GBASE SR  10GBASE LR  10GBASE ER  10GBASE CX4     10GBASE KX4  10GBASE CR  10GBASE KR  SGMII  Protocol Support       Data Rate  1 10 25 40 Gb s     Ethernet       PCI Express Gen3  SERDES   8 0GT s  8 lanes  2 0 and 1 1 compatible   Voltage  12V  3 3V          Typical Power     Passive Cables  11 86W       Maximum Power  Passive Cables  13 50W  1 5W Active Cables  16 83W       Power and       Maximum power available through QSFP28 port  3 5W  Environmental       Temperature  Opera
73. uring   However  Mellanox issues firmware updates occasionally that provide new features and bug  fixes  To check that your card is programmed with the latest available firmware version  down   load the mlxup firmware update and query utility  The utility can query for available Mellanox  adapters and indicate which adapters require a firmware update  If the user confirms  mlxup  upgrades the firmware using embedded images  The latest mlxup executable and documentation  are available from http   www mellanox com   gt  Products   gt  Software   gt  Firmware Tools        5 1 Firmware Update Example     server1     mlxup  Querying Mellanox devices firmware        Device Type  ConnectX4  Part Number  MCX413A BCAT  Description  ConnectX   4 EN network interface card  40GbE single port QSFP28   PCIe3 0 x8  tall bracket  ROHS R6  PSID       2190110032  PCI Device Name  0000 06 00 0  Base GUID  e41d2d0300fd8b8a  Versions  Current Available  FW 12 112          112 112  00   Status  Up to date  Device Type  ConnectX4  Part Number  MCX413A BCAT  Description  ConnectX   4 EN network interface card  40GbE single port QSFP28   PCIe3 0 x8  tall bracket  ROHS R6  PSID       2170110021         Device Name  0000 07 00 0                   0000e41d2da206d4  Versions  Current Available  FW 2 21101161       8100  Status  Update required    Perform FW update   y N   y  Device  1  Up to date  Device  2  Updating FW     Done    Restart needed for updates to take effect   Log File   var log mlxup mlxu
74. ware will be updated  accordingly  However  if the user has both an OEM card and a Mellanox card  only the Mellanox  card will be updated      Y  Upgrade the HCA s firmware version  Recommended    Upgrading the firmware version will reboot your machine     Note  One or more of your HCA adapters has an old firmware version  We recommend  upgrading to a newer firmware version to enable improved functionality and  support driver s capabilities     InstallShield             Step 8  Select a Complete or Custom installation  follow Step a and b on page 37     Setup Type  Choose the setup type that best suits your needs     Please select a setup type        Complete  All program features will be installed   Requires the most disk  space                 Custom    Choose which program features you want installed and where they  will be installed  Recommended for advanced users           Mellanox Technologies 36      ConnectX 4 Ethernet Single and Dual        QSFP28 Adapter Card User Manual Rev 1 3      a  Select the desired feature to install         Performance tools   install the performance tools that are used to measure performance in user envi   ronment        Documentation   contains the User Manual and Release Notes       Management tools   installation tools used for management  such as mlxstat     Custom Setup  Select the program features you want installed        Click on an icon in the list below to change how a feature is installed   El Performace Tools       Feature Descr
75. xtract the MLNX OFED package on a shared location in your network     You can download it from http   www mellanox com  gt  Products  gt  Software   Ethernet   Drivers     Step 3  Create an apt get repository configuration file called   etc apt sources list d mlnx   _ofed list  with the following content     deb file   lt path to extracted MLNX OFED package gt        Step 4  Download and install Mellanox Technologies GPG KEY       wget  40   http   www mellanox com downloads ofed RPM GPG KEY Mellanox   sudo apt key  add      Step 5  Check that the key was successfully imported     apt key list  pub 1024D A9E4B643 2013 08 11  uid     11         Technologies  lt support mellanox com gt   sub 10249 09      269 2013 08 11  Step 6  Update the apt get cache       sudo apt get update    4 1 6 2 Installing MLNX_OFED using the apt get Tool  After setting up the apt get repository for MLNX_OFED package  perform the following   Step 1  View the available package groups by invoking       apt cache search mlnx ofed   mlnx ofed all  mlnx ofed basic  mlnx ofed vma  mlnx ofed vma eth  mlnx ofed vma vpi    Mellanox Technologies 29      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      Where   mlnx ofed all MLNX OFED all installer package   mlnx ofed basic MLNX OFED basic installer package   mlnx ofed vma MLNX OFED vma installer package   mlnx ofed vma eth MLNX OFED vma eth installer package   mlnx ofed vma vpi MLNX OFED vma vpi installer package     Step 2 
76. y  CB   cTUVus   CE       Regulatory                FCC   VCCI   ICES   RCM       RoHS  RoHS R6                a  Typical power for ATIS traffic load   b  For both operational and non operational states     Mellanox Technologies 59      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      7 11 Airflow Specifications       Air Flow  LFM      Air Flow Heat Sink to Port Port to Heat Sink  Direction  Cable Type Passive          an Passive en p   MCX413A BCAT 400 450   400 400    MCX414A BCAT 400 450   400 400    MCX416A BCAT 400 500   400 400    MCX413A GCAT 400 400   400 400    MCX414A GCAT TBD TBD   TBD TBD    MCX416A GCAT 400 500 400 400    MCX415A CCAT 400   700 400   600  MCX416A CCAT 400     850 400   600          a  Cells marked with     are not applicable    Mellanox Technologies 60      ConnectX 4 Ethernet Single and Dual Port QSFP28 Adapter Card User Manual Rev 1 3      7 12 Adapter LED Operation  There is a one bi color I O LED per port  See Table 19     Table 19   Physical and Logical Link Indications       LED Function       Yellow   physical   Constant on indicates    good physical link  link   Blinking indicates a problem with the physical link    If neither LED is lit  then the physical link has not been established       Green   logical  data        constant green indicates a valid logical  data activity  link without data transfer   activity  link   A blinking green indicates a valid logical link with data transfer               
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Manuel d`utilisation Nokia Lumia 800  manuale d`uso - AE SUNTEK VENETO  19 Emploi - Grand Evreux Agglomération  Samsung Multi Sistema - Mural - MH026FAEA manual de utilizador  AH Sharpshooter IS GTL M10  HP V5061u Data Sheet  Huygens Professional User Guide  Garmin TR-1 Instruction Manual  Instalación:  Service Manual - Doosan Infracore    Copyright © All rights reserved. 