image

Contents

1. 2 piece i CC Link ve Direct coupled communication Analog I O section section 7 8 Terminal numbers and ll a appearance ON Power supply on PIRLED OFF Power supply off Normal operation S 0 1s intervals indicate an output range setting error 0 5s intervals indicate a digital value setting error 24VDC power supply shutoff or watchdog timer error occurred RUN LED On Indicate that the SELECT SET switch is in the SET position Flashing 0 1s intervals indicate that the output range setting is not any of user range settings 1 to 3 0 5s intervals indicates that you attempted to eee make offset gain setting outside the setting range did EER Off Indicates that the SELECT SET switch is in the SELECT or center position L RUN On Normal communication LED Off Communication cutoff time expiration error On Indicates that transmission speed setting or station number setting is outside the range Flicker at fixed intervals Indicates that transmission speed setting or station number setting was changed from that at power on Flicker at unfixed intervals Indicates that you forgot fitting the termination resistor or the module or CC Link dedicated cable is affected by noise Off Indicates normal communications Normal mode appearance Offset gain Normally OFF djusti ne Test The LEDs lit change every time the SELECT SET mode switch is moved to SELECT et Used to make
2. 66 2 517 1326 Spain Mitsubishi Electric Europe B V Spanish Indonesia P T Autoteknindo Sumber Makmur Branch Muara Karang Selatan Block A Utara No 1 Kav No 11 Kawasan Industri Pergudangan Jakarta Utara 14440 P O Box 5045 Jakarta 11050 Indonesia Tel 62 21 6630833 Carretera de Rubi 76 80 E 08190 Sant Cugat del Valles Barcelona Spain Tel 34 93 565 3131 France der Electric Europe B V French India Mes nea 25 Boulevard des Bouvets F 92741 Electronic Sadan NO III Unit No15 Nanterre Cedex France M I D C Bhosari Pune 411026 India Tel 33 1 5568 5568 Tel 91 20 2712 3130 South Africa Circuit Breaker Industries Ltd Australia Mitsubishi Electric Australia Pty Ltd Private Bag 2016 ZA 1600 Isando 348 Victoria Road Rydalmere South Africa N S W 2116 Australia Tel 27 11 928 2000 Tel 61 2 9684 7777 MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN When exported from Japan this manual does not require application to the Ministry of Economy Trade and Industry for service transaction permission Specifications subject to change without notice
3. MITSUBISHI Digital Analog Converter Module Type AJ65SBT 62DA User s Manual Hardware Thank you for buying the Mitsubishi general purpose programmable controller MELSEC Series Prior to use please read both this manual and detailed manual thoroughly and familiarize yourself with the product MODEL AJ65S 62DA U H JE MODEL CODE 133110 IB NA 0800139 G 1112 MEE EEE 2000 MITSUBISHI ELECTRIC CORPORATION O SAFETY PRECAUTIONS e Read these precautions before using this product Before using this product please read this manual and the relevant manuals carefully and pay full attention to safety to handle the product correctly These precautions apply only to this equipment Refer to the user s manual of the CPU module to use for a description of the programmable controller system safety precautions In this manual the safety precautions are classified into two levels AAWARNING and Z CAUTION Indicates that incorrect handling may cause hazardous AWARNING conditions resulting in death or severe injury NCAUTION Indicates that incorrect handling may cause hazardous conditions resulting in minor or moderate injury or property damage N uf Under some circumstances failure to observe the precautions given under CAUTION may lead to serious consequences Observe the precautions of both levels because they are important for personal and system safety Make sure that the end users re
4. solderless terminals 2 max connection Direct coupled 18 point terminal block analog output area I O area M3 x 5 2 Tightening torque 0 59 to 0 88N m Applicable solderless terminals 2 max e RAV1 25 3 conforming to JIS C 2805 Applicable solderless Applicable wire size 0 3 to 1 25mm terminals e V2 MS3 RAP2 3SL TGV2 3N Applicable wire size 1 25 to 2 0mm Dielectric withstand voltage AJ65SBT 62DA M4 screw x 0 7mm x 16mm or more Module mounting screw tightening torque range 0 78 to 1 08N m Can also be mounted to DIN rail External power supply Current consumption 0 16A at 24VDC Weight 0 20 kg D A conversion values are fluctuated by self heating within approx 30 minutes after power is turned ON 2 3 Checking hardware versions The hardware versions of the AJ65SBT 62DA can be checked on the DATE section on the rating plate which is situated on the side of the module CC Link MITSUBISHI Year and month of manufacture Hardware version Software version Conformed standard OO MITSUBISHI ELECTRIC CORPORATION MADE IN JAPAN BD992C154H06 3 NAME OF EACH PART The name of each part in the AJ65SBT 62DA is shown a STATION _NO 4020 10 8 4 2 1 W RUN LRUNLERR CH12 OFFSETGAIN Ae Bo ea ee Tafuna MITSUBISHI MELSEC AssssBT 62DA SET DOWN ZDAL DG 2 248 TEST O IA DB SLD A FG TEST NC COM NC OM NC NC NC
5. to products other than Mitsubishi products and to other duties Country Region Sales office Tel Country Region Sales office Tel U S A Mitsubishi Electric Automation Inc China Mitsubishi Electric Automation 500 Corporate Woods Parkway Vernon China Ltd Hills IL 60061 U S A A F Zhi Fu Plazz No 80 Xin Chang Road Tel 1 847 478 2100 Shanghai 200003 China Tel 86 21 6120 0808 Brazil MELCO TEC Rep Com e Assessoria Tecnica Ltda Taiwan Setsuyo Enterprise Co Ltd Rua Correia Dias 184 6F No 105 Wu Kung 3rd Rd Wu Ku nn a andar Hsiang Taipei Hsine Taiwan i u zi d y Tel 886 2 2299 24 Tel 55 11 5908 8331 a Germany Mitsubishi Electric Europe B V German sorea ane a oo Autsnelloh Pen 1480 6 Gayang dong G k Gothaer Strasse 8 D 40880 Ratingen BR Be a al GERMANY Seoul 157 200 Korea Tel 49 2102 486 0 Tel 82 2 3660 9552 U K Mitsubishi Electric Europe B V UK Singapore Mitsubishi Electric Asia Pte Ltd Branch 307 Alexandra Road 05 01 02 Travellers Lane Hatfield Hertfordshire Mitsubishi Electric Building AL10 8XB U K Singapore 159943 Tel 44 1707 276100 Tel 65 6470 2480 Italy Mitsubishi Electric Europe B V Italian Thailand Mitsubishi Electric Automation Thailand Branch Co Ltd Centro Dir Colleoni Pal Perseo Ingr 2 Bang Chan Industrial Estate No 111 Via Paracelso 12 20041 Agrate Brianza Moo 4 Serithai Rd T Kannayao Milano Italy A Kannayao Bangkok 10230 Thailand Tel 39 039 60531 Tel
6. G User s Manual 13JR64 CC Link System Master Local Module User s Manual A 6 COMPLIANCE WITH EMC AND LOW VOLTAGE DIRECTIVES 1 Method of ensuring compliance To ensure that Mitsubishi programmable controllers maintain EMC and Low Voltage Directives when incorporated into other machinery or equipment certain measures may be necessary Please refer to one of the following manuals e User s manual for the CPU module or head module used e Safety Guidelines This manual is included with the CPU module base unit or head module The CE mark on the side of the programmable controller indicates compliance with EMC and Low Voltage Directives 2 Additional measures To ensure that this product maintains EMC and Low Voltage Directives please refer to one of the manuals listed under 1 A 7 1 OVERVIEW This user s manual explains the specifications names and setting of parts wiring and others of Type AJ65SBT 62DA digital analog converter module hereafter abbreviated to the AJ65SBT 62DA which is used as a remote device station of a CC Link system 2 SPECIFICATION 2 1 General specifications The general specifications of the AJ65SBT 62DA are shown below Specification Operating ambient 0 to 55 C temperature Storage ambient 20 to 75 C temperature Operating ambient humidity a Storage ambient 10 to 90 RH non condensing humidit ne F Constant Half Sweep requency acceleration amplitude count Complian
7. ad this manual and then keep the manual in a safe place for future reference Design Precautions WARNING e Configure safety circuits external to the programmable controller to ensure that the entire system operates safely even when a fault occurs in the external power supply or the programmable controller Failure to do so may result in an accident due to an incorrect output or malfunction 1 The status of analog output depends on the setting of various functions that control the analog output Exercise great caution when setting those functions For details of analog output status refer to Section 3 4 1 Combinations of various functions in the user s manual for the module 2 Due to failure of the output element or internal circuit normal output may not be obtained correctly Configure an external circuit for monitoring output signals that could Cause a serious accident A 1 Design Precautions CAUTION e Do not install the control lines or communication cables together with the main circuit lines or power cables Keep a distance of 100mm 3 94 inches or more between them Failure to do so may result in malfunction due to noise e When a module is powered ON OFF voltage or current may instantaneously be output from the output terminal of this module In such case wait until the analog output becomes stable Then start controlling the external device Installation Precautions CAUTION Use t
8. any other kind nor does it confer any patent licenses Mitsubishi electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual O 2000 MITSUBISHI ELECTRIC CORPORATION A 5 CONTENTS 1 OVERVIEW ara 1 2 SPECIFICATION A A O 1 2 1 General specifications e a ae eo 1 22 Performance specifications EEN AAA A errr cree 2 2 3 Checking hardware versions EEE TERETE TNE EES NS Sew SEES ee See REE ES PEERS 3 3 NAME OF EACH PART PTT ee O 4 4 LOADING AND INSTALLATION ret AA A A eee Cer RA 6 4 1 Precautions when handling HSE PLAN RRCCEEN OEE SNIE 6 42 Installation environment iaa oie 6 5 DATA LINK CABLE WIRING E a a a EE EENE 7 5 1 Connection of the CC Link dedicated cables pi ne di yi 7 6 WIRING A a O O 7 6 1 Wiring precautions LENA oor occ rrr tae 7 6 2 Module connection example TCC A Cre A eer Cee re eer ee er eae 8 7 EXTERNAL DIMENSIONS EEE A AS O rer e E 9 ABOUT MANUAL The following manuals are also related to this product In necessary order them by quoting the details in the tables below Detailed Manual Manual name Manual No Model code Digital Analog Converter Module Type AJ65SBT 62DA SH 080107 User s Manual 13JR19 Related Manual Model code AJ61BT11 A1SJ61BT11 User s Manual 13J872 AJ61QBT11 A1SJ61QBT11 User s Manual 13J873 SH 080394E 13JR64 MELSEC L CC Link System Master Local Module SH 080895EN
9. elow Master module AJ65SBT 62DA 1 0 module etc B pie Blue Blue DA 7 y pne White io it DB Terminal Yellow gt ellow Terminal resistor LASI SL a E A ten DG resistor CC Link CC Link so i dedicated cable dedicated cable FG 6 WIRING 6 1 Wiring precautions To obtain maximum performance from the functions of AJ65SBT 62DA and improve the system reliability an external wiring with high durability against noise is required The precautions when performing external wiring are as follows 1 Use separate cables for the AC and AJ65SBT 62DA external output signals in order not to be affected by the AC side surge or conductivity 2 Do not bundle or place with load carrying wires other than the main circuit line high voltage line or programmable controller Noises surges or conductivity may affect the system 3 Place a one point grounding on the programmable controller side for the shielded line or shielded cable 6 2 Module connection example 1 For voltage output Motor drive unit or like 1 Use a two core twist shielded line for the wiring 2 If noise or ripples occur in the external wiring connect a 0 1 to 0 47uF capacitor 25V or higher voltage resistant product to the input terminals of the external device 2 For current output Motor drive unit or like 1 Use a two core twist shielded line for the wiring 2 If noise or ripples occur in the
10. external wiring connect a 0 1 to 0 47uF capacitor 25V or higher voltage resistant product to the input terminals of the external device 7 EXTERNAL DIMENSIONS The external dimensions of the AJ65SBT 62DA is shown below The appearance of the AJ65SBT 62DA varies depending on the hardware version For checking method of the hardware version refer to Section 2 3 1 Hardware version H or later e y 22 118 4 65 4 5 109 4 29 4 5 0 18 0 18 2 4 5 x 5 1 installation hole len we 24v 246 TEA LAS Ce STLNC 717 v 1 Nc TEST 7 OS 900000008 passa 929959337 2 Hardware version G or earlier NP 40 1 57 118 4 65 109 4 29 2 4 5 x 5 1 installation hole M4 installation screw VE bom mm TI TT TS u u W65SBT 62DA er OWN frest _nc v Nc v NC NON TEST esse sessessso Y6SGA O OOOOSO Se F DS 0 rs y 0 16 0 18 Unit mm inch Unit mm inch MEMO MEMO MEMO MEMO WARRANTY Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages
11. he programmable controller in an environment that meets the general specifications in this manual Failure to do so may result in electric shock fire malfunction or damage to or deterioration of the product O For protection of the switches do not remove the cushioning material before installation e Securely fix the module with a DIN rail or mounting screws Tighten the screws within the specified torque range Undertightening can cause drop of the screw short circuit or malfunction Overtightening can damage the screw and or module resulting in drop short circuit or malfunction e Do not directly touch any conductive part of the module Doing so can cause malfunction or failure of the module Wiring Precautions CAUTION e Shut off the external power supply for the system in all phases before wiring Failure to do so may result in damage to the product e Ground the FG terminals to the protective ground conductor dedicated to the programmable controller Failure to do so may result in malfunction e Tighten any unused terminal screws within the specified torque range 0 42 to 0 50Nem Failure to do so may cause a short circuit due to contact with a solderless terminal Use applicable solderless terminals and tighten them within the specified torque range If any spade solderless terminal is used it may be disconnected when the terminal screw comes loose resulting in failure e Check the rated voltage and termina
12. jury to the public or property Notwithstanding the above restrictions Mitsubishi may in its sole discretion authorize use of the PRODUCT in one or more of the Prohibited Applications provided that the usage of the PRODUCT is limited only for the specific applications agreed to by Mitsubishi and provided further that no special quality assurance or fail safe redundant or other safety features which exceed the general specifications of the PRODUCTs are required For details please contact the Mitsubishi representative in your region A 4 REVISIONS The manual number is noted at the lower right of the top cover Revision IB NA 0800139 A Mar 2005 IB NA 0800139 B Section 2 3 SAFETY PRECAUTIONS Conformation to the EMC Directive and Low Voltage Instruction Chapter 1 Section 2 1 2 2 5 2 6 1 Chapter 7 Mar 2006 IB NA 0800139 C Revisions Conformationto the EMC Directive and Low Voltage Instruction Section 2 3 Sep 2006 IB NA 0800139 D SAFETY PRECAUTIONS Chapter 3 Chapter 7 Oct 2008 IB NA 0800139 E SAFETY PRECAUTIONS Compliance with the EMC and Low Voltage Directives Section 2 1 2 2 4 1 6 2 Section5 1 Dec 2010 IB NA 0800139 F Addition CONDITIONS OF USE FOR THE PRODUCT SAFETY PRECAUTIONS About Manual Section 2 1 2 2 4 1 5 1 6 2 Dec 2011 IB NA 0800139 G SAFETY PRECAUTIONS Chinese Section 2 1 This manual confers no industrial property rights or any rights of
13. l layout before wiring to the module and connect the cables correctly Connecting a power supply with a different voltage rating or incorrect wiring may cause a fire or failure A 2 Wiring Precautions CAUTION e Tighten the terminal screw within the specified torque range Undertightening can cause short circuit or malfunction Overtightening can damage the screw and or module resulting in drop short circuit or malfunction O Prevent foreign matter such as dust or wire chips from entering the module Such foreign matter can cause a fire failure or malfunction Place the cables in a duct or clamp them If not dangling cable may swing or inadvertently be pulled resulting in damage to the module or cables or malfunction due to poor contact e Do not install the control lines or communication cables together with the main circuit lines or power cables Failure to do so may result in malfunction due to noise e When disconnecting the cable from the module do not pull the cable by the cable part Loosen the screws of connector before disconnecting the cable Failure to do so may result in damage to the module or cable or malfunction due to poor contact Startup and Maintenance Precautions CAUTION e Do not touch any terminal while power is on Doing so may cause malfunction e Shut off the external power supply for the system in all phases before cleaning the module or retightening the terminal screws Failure t
14. n the PRODUCT The PRODUCT has been designed and manufactured for the purpose of being used in general industries MITSUBISHI SHALL HAVE NO RESPONSIBILITY OR LIABILITY INCLUDING BUT NOT LIMITED TO ANY AND ALL RESPONSIBILITY OR LIABILITY BASED ON CONTRACT WARRANTY TORT PRODUCT LIABILITY FOR ANY INJURY OR DEATH TO PERSONS OR LOSS OR DAMAGE TO PROPERTY CAUSED BY the PRODUCT THAT ARE OPERATED OR USED IN APPLICATION NOT INTENDED OR EXCLUDED BY INSTRUCTIONS PRECAUTIONS OR WARNING CONTAINED IN MITSUBISHI S USER INSTRUCTION AND OR SAFETY MANUALS TECHNICAL BULLETINS AND GUIDELINES FOR the PRODUCT Prohibited Application Prohibited Applications include but not limited to the use of the PRODUCT in e Nuclear Power Plants and any other power plants operated by Power companies and or any other cases in which the public could be affected if any problem or fault occurs in the PRODUCT e Railway companies or Public service purposes and or any other cases in which establishment of a special quality assurance system is required by the Purchaser or End User e Aircraft or Aerospace Medical applications Train equipment transport equipment such as Elevator and Escalator Incineration and Fuel devices Vehicles Manned transportation Equipment for Recreation and Amusement and Safety devices handling of Nuclear or Hazardous Materials or Chemicals Mining and Drilling and or other applications where there is a significant risk of in
15. o do so may cause the module to fail or malfunction Undertightening the terminal screws can cause short circuit or malfunction Overtightening can damage the screw and or module resulting in drop short circuit or malfunction e Do not disassemble or modify the modules Doing so may cause failure malfunction injury or a fire e Do not drop or apply strong shock to the module Doing so may damage the module e Shut off the external power supply for the system in all phases before mounting or removing the module to or from the panel Failure to do so may cause the module to fail or malfunction O After the first use of the product do not mount remove the terminal block to from the module more than 50 times IEC 61131 2 compliant O Before handling the module touch a grounded metal object to discharge the static electricity from the human body Failure to do so may cause the module to fail or malfunction Disposal Precautions CAUTION When disposing of this product treat it as industrial waste A 3 e CONDITIONS OF USE FOR THE PRODUCT e 1 Mitsubishi programmable controller the PRODUCT shall be used in A conditions i where any problem fault or failure occurring in the PRODUCT if any shall not lead to any major or serious accident and ii where the backup and fail safe function are systematically or automatically provided outside of the PRODUCT for the case of any problem fault or failure occurring i
16. offset gain setting in the test mode 4 UP DOWN Used to adjust the offset value and gain value of the channel specified by the switch SELECT SET switch Use the switches in STATION NO 10 20 and 40 to set the tens of the station number Use the switches in STATION NO 1 2 4 and 8 to set the units of the station number The switches are all factory set to OFF Always set the station number within the range 1 to 64 You cannot set the same station number to two or more stations Setting any other number than 1 to 64 will result in an error flickering the L ERR LED Station Station number a0 20 0 8 4 2 I 1 number seting y ae FF ON OFF OFF gt O 7 T O 7 T O 7 T O 7 T STATION NO 40 2010 8 4 2 1 er A MT E era ETE PE TT Se AU o ales Example To set the station number to 32 set the switches as indicated below Station number 40 20 10 8 a 2 1 Set value Setting switches Transmission i speed Transmission speed setting 0 OFF OFF OFF 156kbps switches 1 OFF OFF ON 625kbps 2 5Mbps I 3 OFF ON ON _ 5 0Mbps 10Mbps Always set the transmission speed within the above range The switches are all factory set to OFF Making any other setting than the above will result in an error flickering the L ERR LED Le ee Used to connect the module power supply transmission and I O signals block 7 DIN rail hook Used to m
17. ount the module to the DIN rail 4 LOADING AND INSTALLATION 4 1 Precautions when handling The following is an explanation of handling precautions of the module 1 Do not drop or apply any strong impact to the module 2 Tighten the screws such as module installation screws with the following torque Tightening torque range Module installation screw M4 screw 0 78 to 1 08Nem Terminal block terminal screw M3 screw 0 59 to 0 88Nem Terminal block installation screw M3 5 screw 0 68 to 0 98Nem 4 2 Installation environment Never install the A series programmable controller in the following environments 1 Locations where the ambient temperature is outside the range of O to 55 C 2 Locations where the ambient humidity is outside the range of 10 to 99 RH 3 Locations where dew condensation takes place due to sudden temperature changes 4 Locations where there are corrosive and or combustible gasses 5 Locations where there is a high level of conductive power such as dust and iron filings oil mist salt and organic solvents 6 Locations exposed to the direct rays of the sun 7 Locations where strong power and magnetic fields are generated 8 Locations where vibration and shock are directly transmitted to the main module 5 DATA LINK CABLE WIRING 5 1 Connection of the CC Link dedicated cables Connect the CC Link dedicated cable between the AJ65SBT 62DA and master module as shown b
18. put Current 16 bit signed binary 0 to 4095 Voltage 10 to 10V DC external load resistance 2kQ to 1M output 0 to 20mA DC external load resistance 0 to 6002 Digital input value 4000 to User range 4000 setting 1 I O characteristics 10 to 10V maximum resolution Voltage accuracy accuracy relative to maximum value of analog User range output value 0 to 5V pone Current 0 to 4000 setting 3 0 to 20mA Factory setting is 10 to 10V Maximum conversion speed 1ms 1 channel Output short circuit Y es protection Absolute maximum output Voltage 12V Current 21mA Number of analog output Schana modale points CC Link station type Remote device station dlls Shgecupled 1 station RX RY 32 points each RWr RWw 4 points each Communication cable CC Link dedicated cable 500V AC for 1 minute across all power supply and communication system terminals and all analog output terminals Across communication system terminals and all analog output terminals Photocoupler isolated Isolation system Across power supply system terminals and all analog output terminals Photocoupler isolated Across channels Non isolated Noce imini By noise simulator of 500Vp p noise voltage 1us noise width and 25 to y 60Hz noise frequency Communication Point 2 piece terminal block transmission circuit module power supply FG area module 143 x 5 2 Tightening torque 0 59 to 0 88N m External power supply Applicable
19. t Under 5to84Hz 3 5mm 10 times with JIS B intermittent 8 4 to gane A X 3502 and IEC vibration 150Hz 8m s 61131 2 directions Under 5to84Hz 1 75mm vibration 150Hz i 147m s 3 times each in 3 directions X Y Z atmosphere 010 200m Inside a control panel Overvoltage lores category Pollution degree 2 or less 1 This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution network and the machinery within premises Category Il applies to equipment for which electrical power is supplied from fixed facilities The surge voltage withstand level for up to the rated voltage of 300V is 2500V 2 This index indicates the degree to which conductive material is generated in terms of the environment in which the equipment is used Pollution level 2 is when only non conductive pollution occurs A temporary conductivity caused by condensing must be expected occasionally 3 Do not use or store the programmable controller under pressure higher than the atmospheric pressure of altitude Om Doing so may cause malfunction When using the programmable controller under pressure please consult your local Mitsubishi Electric representative Vibration resistance 2 2 Performance specifications The performance specifications of the AJ65SBT 62DA are shown below AJ65SBT 62DA Digital Voltage 16 bit signed binary 4096 to 4095 in