Home

Intramuscular Injection Simulator

image

Contents

1. 3 2 1 Injection site Intramuscular injections into the muscles of the upper arm are administered at the highest point of the deltoid muscle m deltoideus To do this first locate the acromion point of the shoulder The injection or puncturing site is located three finger widths approx 2 below the palpated acromion 3 2 2 Disinfection of the skin Please use only normal tap water to disinfect the skin since ordinary disinfectants may damage the materials of the model 3 2 3 Intramuscular i m injection and removal of the cannula Intramuscular injections are usually administered perpendicularly at a 90 angle to the skin surface Now introduce the cannula into the deltoid muscle as deeply as required approx 1 2 cm To exclude the possibility that the vessel has been punctured perform an aspiration Then administer the injection slowly When finished withdraw the cannula with a quick tug Then compress the injection site with a sterile pad 4 Operation amp storage 4 1 Fastening the simulator to a person Place the injection simulator at the transition from shoulder to upper arm and attach it to the upper arm with the fastening strap To do this thread the strap through the buckle and pull tight to the desired width then press the buckle closed 4 2 Tabletop operation Position the injection simulator on a level and non slippery surface 4 3 Storage The injection simulator is best stored at a dry place at ro
2. Intramuscular Injection Simulator English Thank you for choosing a 3B Scientific product Please read the user manual carefully before using the unit to ensure a flawless operation and to enable you to work in a satisfactory way with this product Table of contents 1 Ouick Instructions 3 11 Turning the unit on 3 1 2 Tbutton C button 3 1 3 Matrix of the result indicator 4 14 Turning the unit off 4 2 Getting started and operation 4 2 1 Accessories 4 2 2 Some preliminary remarks 4 2 3 Power supply 4 24 Inserting and removing the batteries 4 3 Working with the P55 6 3 1 Operation 6 3 111 Layout of the display 6 3 1 2 Turning the unit on and off 6 3 1 3 Training mode T button 6 3 14 Control mode C button 6 3 2 Administering an intramuscular i m injection into the upper arm 7 3 2 1 Injection site 7 3 2 2 Disinfection of the skin 7 3 2 3 Intramuscular i m injection and removal of the cannula 7 4 Operation and Storage 7 41 Fastening the simulator to a person 7 N 4 2 Tabletop operation 4 3 Storage 7 5 General safety precautions 7 6 Frequently asked questions FAQ s 8 6 1 The battery indicator is flashing after turning the unit on again the indicator is off but why does it then light up again 8 6 2 Why can t the injection simulator be turned on again after prolonged storage 8 6 3 Which types of batteries are recom mended for the injection simulator 8 6 4 Canialso operate the injec
3. LED green when you have performed the intramuscular injection correctly negative feedback result indicator LED red acoustic signal when you hit the bone When performing the injection at incorrect sites or not deep enough no result will be indicated To perform another injection in the training mode please press the T button T again 3 1 4 Control mode C button Pressthe C button i The yellow status indicator next to the C button lights up Now administer the injection The information whether the site and depth of the injection have been selected correctly is now temporarily saved by the unit but not yet displayed After completing the injection press the C button once more to indicate the result The yellow status indicator next to the C button will flash during this process You will receive positive feedback result indicator LED green when you have performed the injection into the muscle correctly correct site and correct depth English Intramuscular Injection Simulator negative feedback result indicator LED red when you have performed the injection incorrectly at wrong sites and or not deep enough When hitting a bone during the injection you will receive immediate negative feedback result indicator LED red acoustic signal To perform another injection in the control mode please press the C button again 3 2 Administering an intramuscular i m injection into the upper arm
4. injection into the muscle correctly negative feedback result indicator LED red acoustic signal when you hit the bone le In the control mode C button you will receive no feedback while performing an injection into the muscle The result will be saved and you have to press the C button again to check whether you have carried out the intramuscular injection correctly or incorrectly You will receive positive feedback result indicator LED green when you have performed the intramuscular injection correcily negative feedback result indicator LED red when you have performed the injection incorrectly When you hit the bone while injecting you will immediately receive negative feedback result indicator LED red acoustic signal Intramuscular Injection Simulator English 1 3 Matrix of the result indicator Result indicator Result indicator training mode control mode Correct injection site green Incorrect injection site red Injection into the bone red red 1 4 Turning the unit OFF The unit automatically switches off when it has not been used for a period of two minutes or can be manually turned off by simultaneously pressing the T button and the C button 2 Getting started and operation 2 1 Accessories P55 Injection Simulator upper arm with humerus stump foam muscle and silicone skin preassembled Replacement silicone skin Disposable 5 ml syringe Injection cannula for intramuscul
5. Operation 3 1 1 Layout of the display O Status light red LED for battery Start button G T button training mode 4 Status indicator yellow LED for T button G Status indicator red LED for C button 6 C button control mode Result indicator red and green LED 3 1 2 Turning the unit ON and OFF Turning ON Press the Start button o All LEDs will now flash five times to confirm functionality If not please check if the batteries have been inserted correctly and if necessary replace them with new batteries or fully recharged batteries If individual LEDs should not light up please contact your dealer s customer service After the function test the unit will automatically switch into training mode This is confirmed by the yellow status indicator for training mode Turning OFF The P55 Injection Simulator automatically turns off when it has not been used for a period of two minutes However it can also be manually switched off by pressing T simultaneously During prolonged periods of non usage please remove the batteries from the battery compartment This is to prevent any leaking batteries from causing damage to the unit 3 1 3 Training mode T button Press the T button T The yellow status indicator next to the T button lights up Now administer the injection You will receive immediate feedback as follows while performing the injection positive feedback result indicator
6. ar injections AA batteries Operating instructions CD ROM 2 2 Some preliminary remarks Place the supplied batteries into the P55 Injection Simulator before first usage see 2 4 Inserting the batteries Please use only the rechargeable or non rechargeable batteries for the P55 Injection Simulator recommended on page 8 section 6 3 When inserting the batteries please ensure correct polarity Incorrectly inserted batteries may damage the unit The skin of the 3B Scientific injectable upper arm is made of an elastic material silicone After prolonged usage and repeated punctures in the same area it may become necessary to substitute the skin with the supplied replacement skin Injections into the simulator should only be performed using cannula gauges 20 and 21 gauge 0 8 4 cm long syringe 2 3 Power supply The P55 Injection Simulator is supplied with two 1 5 V type AA LR6 alkaline manganese batteries These enable an operating time of up to 20 hours This period may vary depending on the type of batteries used 2 4 Inserting and replacing the batteries Pull the felt cover attached at the rear of the injection simulator down at the flap see p 5 figs 1 and 2 Open the cover of the battery compartment and then insert the supplied AA batteries ensuring correct polarity see p 5 figs 3 and 4 English Intramuscular Injection Simulator Intramuscular Injection Simulator English 3 Working with the P55 3 1
7. harge even while the unit is turned off Self discharge is approximately 2096 per month Even disposable batteries run down slightly while the injection simulator is turned off Tip Remove the batteries from the battery compartment when not using the unit for a prolonged period of time This is to prevent that any leaking batteries cause damage to the unit After the injection simulator has not been used for a prolonged period of time only insert freshly recharged batteries or new batteries into the unit 6 3 Which types of batteries are recommended for the injection simulator We recommend the use of alkaline manganese batteries type AA batteries or LR6 Zinc carbon batteries should not be used 6 4 Can I also operate the injection simulator with rechargeable batteries Yes you can use Ni MH nickel metal hydride or Ni Cd nickel cadmium rechargeable batteries You will achieve a substantially longer operation time with Ni MH batteries than with Ni Cd batteries Tip Use batteries of the same type age and manufacturer only 7 Transport and packaging Please check the shipping and product packaging for any damage In case of transport damage please contact your dealer Please keep the original packaging This special packaging is the best protection for your valuable product during transport 8 Maintenance 8 1 Care instructions The silicone skin of the injection simulator can be cleaned with a mild soap solution Please do not
8. ized persons carrying out or attempting repairs modifications or changes or when the product or any part of it has been damaged by an accident unintended usage or misuse 8 4 Reguest for replacement parts Silicone skin XP300 In case of a complaint please indicate the serial number located at the center of the bottom of the base housing under the felt cover of the injection simulator 11 3B SCIENTIFIC Bgiqesssstolu 3B Scientific GmbH Rudorffweg 8 21031 Hamburg Germany Tel 49 40 73966 0 Fax 49 40 73966 100 www 3bscientific com 3b 3bscientific com O Copyright 2005 for instruction manual and design of product 3B Scientific GMbH Germany P55 03 05 1
9. om temperature Do not expose the injection simulator to direct sunlight since heat over 45 C may cause the material to deform or become brittle When the injection simulator is not used for a prolonged period of time it is recommended to remove the batteries 5 General safety precautions Keep out of the reach of children Do not recharge batteries LR6 under any circumstances Risk of Explosion Empty batteries must be disposed of in accordance with the national requirements Environment components must be disposed of in accordance with the relevant national environment regulations concerning the decommissioning and final disposal of the unit Recharge batteries only with a suitable charging set Do not use any powerful chemicals to clean the unit since these may cause damage to the materials of the model Intramuscular Injection Simulator English 6 Frequently asked questions FAQs 6 1 The battery indicator is flashing After turning the unit on again the indicator is off But why does it then light up again This may happen when batteries of different capacities are used In this case please replace the batteries with new ones Tip As a rule only use batteries of the same type the same capacity the same age and the same manufacturer Mark matching batteries accordingly 6 2 Why can t the injection simulator be turned on again after prolonged storage Rechargeable batteries are subject to self disc
10. tion simulator with rechargeable batteries 8 7 Transport and packaging 8 8 Maintenance 8 8 1 Care instructions 8 8 2 Exchanging the silicone skin 8 8 3 Warranty 11 8 4 Request for replacement parts 11 English Intramuscular Injection Simulator 1 Ouick Instructions D Status light red LED for battery 2 Start button G T button training mode O Status indicator yellow LED for T button Status indicator yellow LED for C button 6 C button control mode Result indicator red and green LED G 1 1 Turning the unit ON Before using the unit for the first time please insert the supplied batteries 2x AA see p 4 2 4 Info Status light battery isoff gt battery is okay Status light battery 3r shows solid red 3r battery is running low Status light battery gt flashes red please exchange battery Map Press the Start button All LEDs will now light up for the functional control phase 4 When the Status indicator for the T button lights up this is a signal that the unit is ready for operation see p 6 3 1 2 1 2 T button C button You can select either the training mode or the control mode Please press the T button for the training mode and the C button for the control mode To the training mode T button you will immediately receive feedback as follows while administering the injection positive feedback result indicator LED green when you have performed the
11. use any detergents containing solvents as these will damage the silicone skin 8 2 Exchanging the silicone skin Undo the three snap fasteners located under the stretcher frame on one side of the stretcher frame of the injection simulator see p 9 fig 5 To do so pull the stretcher frame outwards on the left and right at the grooves in the base housing of the simulator and lift the frame off upwards see p 9 fig 6 Attention Please make sure that the foam muscle is not detached from the underlying bone during this process The silicone skin can now be easily removed see p 10 figs 7 and 8 and substituted by the replacement silicone skin The old silicone skin can be disposed of with normal household waste English Intramuscular Injection Simulator 10 Intramuscular Injection Simulator English English Intramuscular Injection Simulator 8 3 Warranty The warranty period for the injection simulator is 36 months from the invoice date and shall include engineering material and manufacturing defects and the electronic functions of the unit provided that the unit has been subjected to normal usage and appropriate maintenance The warranty shall not cover parts subject to wear such as silicone skin foam core injection cannula disposable syringe and batteries Within the scope of the warranty claim 3B Scientific shall not be obliged to pay compensation for damage caused in the context of or as a conseguence of non author

Download Pdf Manuals

image

Related Search

Related Contents

VGN-NS series  VL-W600 - Panasonic  IC50 詰め替えカートリッジ取扱説明書 EP-301/302/4004/702A/703A    WL-1502 User`s Manual v1.2  Fujitsu CELSIUS M720  Design Project  Art.-Nr.: 90100181 - BTW Spezialwerkzeug GmbH  Mode d`emploi. Détecteur télécommandable et télé programmable  Herzlichen Glückwunsch zum Erwerb des DYMOND  