Home

User Manual - Discount Fire Supplies

image

Contents

1. TWINFLEX pro Repeater Panel Engineering and Commissioning Manual Contents MINTO A T T NT 4 System DESIG Mis cia ir lr aci ie aaao EESE 4 Equipment Guarantees miii raakana aaa daanan kaenda ad sasaauid dashagddhaensededtatndagsvhudecenvaeddas 4 Anti Static Handling Guidelines c cccccccesseeceeneeceeeeeceaeeeeeeeseeeeeceaeeesaaeeceaeeseaeeeeaaeseeaaeseeeeesaeeesaeseeaeeeeneeeaas 4 WANING seeds sees ca E ETEA AA EEE A E AE T E A TE EE eat A NT N ETA 4 EMOS a na ance aa a aa aL E A A A Aa a OA ai aaa Aiat 5 The TWINFLEXOp o Syste e a aas r e ea aar aeran a Aarra Aa aeeai aaae aa eaaa AE iaaea anaiai haarde aAa aisada Pi capitana 5 Repeater Panel Remote Display Unit RDU ssssssssuunnennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn ununun nnnnnn nnmnnn nnmnnn nnmnnn naa 5 General Operation of Repeater Panel csseccesecesessseeseeeneneeeeeneeseaesaseeeeneeeeseaeseaaesasneeeneeeeseaesesnaesesneeeeseenenees 6 Gontro Panel Front sa islands Sas ah sepa ne neces 6 ED PIMGIC ATOM cia A a a E E EROS a aa a ch a atar EA TDi 6 Fire Alami ControlS arseen diccecavsanceass canta a S 0 ondaa dada contatacees dhs ETETE daa A caes 7 System Controls ii A veel eve a iaa 7 O tt AOS 7 Access Level 1 Normal Controls Enabled LED off ecccceececeeeeeeeeeeeeeeeeeeaeeeeeeeseeeeeteaeeeseaeeeeeeeees 8 Access Level 2 user Controls Enabled LED ON oooococincccconccononaconocnnancccnnrnnnnnnn nano cnn nc cnn nn anar cnn 8 End Use
2. ADDRESS For Service Phone During Working Hours Out of Working Hours 12 TWINFLEX pro Repeater Panel Engineering and Commissioning Manual Fire Alarm User Notice Note The Fire alarm system installed in this building has Alarm Confirmation technology to help eliminate false alarms Please read and understand the following information in order to make the most use of the system Operation When the detector within your area activates it will initially only operate the sounders within your own area for a predetermined Confirmation time At the end of the Confirmation time the system will check the detector again to see if the activation has cleared If so the sounders will silence and no further action need be taken If however the detector is still activated the entire system will go into alarm operating all the sounders on the system Action Required If you think that you may have accidentally set off the fire alarms then check the following If the fire alarm within your area only is sounding then check your own area for the cause of the alarm If this proves to be a false alarm due to dust cooking fumes steam cigarette smoke etc then clear the smoke from the area in order to allow the system to reset itself after a few minutes If this happens then no further action is required If the fire alarms in the communal areas are also sounding then follow the building s fire procedures
3. TWINFLE gt Xpro FIRE DETECTION SYSTEM Fire Detection 8 Alarm System Repeater Panel Suitable for TWINFLEX pro control panels from V2 00 Repeater Panel User Manual TO BE RETAINED BY THE END USER 26 1194 Issue 1 TWINFLEX pro Repeater Panel Engineering and Commissioning Manual Fike s policy is one of continual improvement and the right to change a specification at any time without notice is reserved Whilst every care has been taken to ensure that the contents of this document are correct at time of publication Fike shall be under no liability whatsoever in respect of such contents Due to the complexity and inherent importance of a life risk type system training on this equipment is essential and commissioning should only be carried out by competent persons Fike cannot guarantee the operation of any equipment unless all documented instructions are complied with without variation E amp OE TWINFLEX Mulitpoint Fike and Fike Corporation are registered trademarks of Fike Corporation and its subsidiaries All other trademarks trade names or company names referenced herein are the property of their respective owners Fike equipment is protected by one or more of the following patent numbers GB2426367 GB2370670 EP1158472 PT1035528T GB2346758 EP0917121 GB2329056 EP0980056 GB2325018 GB2305284 EP1174835 EP0856828 GB2327752 GB2313690 2009 Fike Safety Technology Ltd All rights reserved Document revised July 2013
4. abled position to go from access level 1 to access level 2 System Controls The menus may be navigated to by using the UP DOWN keys to move the required selection to the top and pressing ENTER to select the chosen one In the example below pressing enter will select current faults Current Events Select 4 v Enter ESC Press the ESC key to exit to the previous menu Access Levels The menu system is divided into two access levels in order to restrict access to those who require it For simple indication the status of the Controls Enabled light will show the level selected as follows E Controls Access Level Description Enabled LED Key Operation 1 NORM 2 USER Access to the Controls requires the operation of the enable controls key Access Level 2 User in order to protect against unauthorised access to the system TWINFLEX pro Repeater Panel Engineering and Commissioning Manual Access Level 1 Normal Controls Enabled LED off Note When in the normal mode the quiescent screen will automatically change to display any fires or faults on the system Pressing the enter button when in level 1 will show the Current Events Menus and may be scrolled through by pressing the UP and DOWN keys Press the ESC key to exit the menu Option 1 Current Fires Option 2 Current Faults Option 3 Current Disables Option 4 Current warnings Events are displayed in text format and may be scrolled through by press
5. al Technical support will not be available if the instruction manual has not been read and understood Please have this instruction manual available whenever you call for technical support EMC This equipment when installed is subject to the EMC directive 2004 108 EC lt is also subject to UK Statutory Instrument 2006 No 3418 To maintain EMC compliance this system must be installed as defined within this manual Any deviation from this renders the installer liable for any EMC problems that may occur either to the equipment or to any other equipment affected by the installation The TWINFLEX pro System The TWINFLEX pro system is an intelligent 2 wire system utilising a conventional type cabling format The system is classed as Analogue non addressable due to the architecture used within the design All field devices including sounders can be connected to the zone via a common 2 core screened cable The devices communicate with the control panel using the TWINFLEX data protocol Repeater Panel Remote Display Unit RDU The TWINFLEX pro repeater panel is smaller than the TWINFLEX pro control panel It does not itself connect to or control detection devices Instead it connects to a control panel and reports events which occur on the control panel It can also perform system controls over the network i e Silence Alarms Reset Sound Alarms amp Silence Buzzer A maximum of 8 repeater panels can be connect
6. ed to a single control panel TWINFLEX pro Repeater Panel Engineering and Commissioning Manual General Operation of Repeater Panel Control Panel Front General Indication LEDs Repeater Information Screen Fire Alarm Controls a OC O O _O O o WINELEX tre oire fault disabled VER FIRE DETECTION SYSTEM H system controls REPEATER MODULE fire alarm controls tum key to enable controls System Controls Controls Enabled Keyswitch LED Indication The operation of the LED indication on the front of the repeater panel is described below The LED indication on the repeater panel can also be confirmed by checking the message displayed in the repeater information screen or by accessing the relevant event log from the repeater menu FIRE FAULT TEST POWER Description Colour State Reason DISABLED Yellow This indicates that a disablement action is in place Continuous The control panel is in the fire state Display will show the zone of origin Yellow Continuous The control panel is in the fault state Display will show the origin This indicates that a test routine is in place Green Continuous This indicates that power is being supplied to the panel TWINFLEX pro Repeater Panel Engineering and Commissioning Manual Fire Alarm Controls The main Fire Alarm Controls may be enabled by turning the key switch to the controls en
7. for evacuation If you discover a genuine fire then follow the building s fire procedures for evacuation activating the nearest Fire Alarm manual call point on the way out if the alarms are not already sounding Do not attempt to put out the fire unless it is safe to do so Further Information Further information will be located adjacent to the Main Fire Alarm Control Panel or may be obtained from either the person responsible for building maintenance or from the Fire Alarm Company responsible for maintaining the Fire Alarm System 13 TWINFLEX pro Repeater Panel Engineering and Commissioning Manual Engineers Notes 14 TWINFLEX pro Repeater Panel Engineering and Commissioning Manual Technical Support Contact your distributor for technical support on this product Do not call the Fike Safety Technology technical support department unless your distributor has first given their advice and attempted to rectify the issue Technical support will not be available if the instruction manual has not been read and understood Please have this instruction manual available whenever you call for technical support CE Fike Safety Technology Ltd 31 Springvale Ind Est Cwmbran UK NP44 5BD 13 DoP 505 0010 15
8. ing the UP and DOWN keys Press the ESC key to exit the menu Access Level 2 user Controls Enabled LED on Pressing the enter button when in level 2 will show the Main Menu and may be scrolled through by pressing the UP and DOWN keys Press the ESC key to exit the menu Option 1 Current Events 1 Current Fires 2 Current Faults 3 Current Disables 4 Current warnings Option 2 Test Repeater 1 Test LEDs 2 Test Keypad 3 Test Buzzer 4 TestLCD 5 Test Backlight Option 3 Repeater Details 1 Buzzer 2 Software Version 3 Repeater Panel 4 Display Baudrate TWINFLEX pro Repeater Panel Engineering and Commissioning Manual End User Training A Fire Alarm System is of little use if the end user and or the responsible persons who will be present in the building do not know how to operate and respond to the system It is therefore essential that commissioning includes training for the users of the system and responsible persons User instructions and a Zone Chart should be left adjacent to the control panel As access to the system must be controlled by responsible persons it would be unusual to display the access codes on this notice These codes must however be available for the responsible persons so ensure that they know and record them in a secure place The TWINFLEX pro User Guide should be explained and left with the responsible person on site for storage in an accessible and known location in order that the resp
9. onsible person and the service engineer may keep information records up to date A single page user instruction sheet is included at the end of this manual A copy of this should be mounted adjacent to the control panel Maintenance The repeater panel does not require user maintenance however periodic functional checks should be carried out by an engineer or responsible persons TWINFLEX pro Repeater Panel Engineering and Commissioning Manual Technical Data Repeater Panel Specification Dimensions mm 250 x 140 x 85 Weight 650 grams Construction UL94 VO rated ABS Cable Entry 6 x 20mm knockouts 4 x double 20mm knockouts Cable type 2 core 1 5mm screened fire rated cable Operating voltage Operating current Quiescent 24V DC Nominal 24V DC Range 21 32V DC 16 mA back light off Operating current Max 24V DC 50 mA controls enabled back light on Communications Multi drop RS 485 Total peripheral bus length 500m max IP rating 20 Maximum number of repeaters per control 8 panel Operating temperature 5 C to 50 C 10 TWINFLEX pro Repeater Panel Engineering and Commissioning Manual Fire Alarm System Notice To Enable the Control Panel Keys fire alarm controls Stent co ca ay You may gain access to the fire alarm controls by inserting the key turning Y4 turn The Controls Enabled LED should then be illuminated To disable the c
10. ontrol panel keys turn the key switch off When disabled the Controls Enabled LED should then be extinguished To prevent unauthorised operation the controls should be kept disabled and the key kept secure under the control of the responsible person To Manually Operate the Fire Alarm Sounders f fire alarm controls tum key to enable controle Enable the controls and then press SOUND ALARMS To silence the alarm sounders press SILENCE ALARMS The red FIRE LED will illuminate The fire alarms and the internal buzzer will operate as programmed Take appropriate action as defined by the emergency plan for the premises To silence the alarm press SILENCE ALARMS then establish the cause of the alarm and enter the details in the log book Reset any Manual Call Points which may have been operated or if a detector has been operated be sure that the cause of the alarm has been removed before resetting the system by pressing RESET SYSTEM The fault LED will illuminate The internal buzzer will sound To mute the internal buzzer press SILENCE BUZZER Investigate and rectify the appropriate fault competent persons Once the fault has been rectified the fault indication will clear automatically 11 TWINFLEX pro Repeater Panel Engineering and Commissioning Manual Important Notes FIRE ALARM COMPANY ADDRESS FOR SERVICE CALL Working hours Call Out FIRE ALARM COMPANY
11. r Tr me pe RN oP ep AS oe Se EE ene mao 9 MAINTON AN CO ooo Nai 9 Technical Dita ii na TAE Ean EEES NEIRE TAE 10 Repeater Panel Specification oooonnnccinnin nnnnnnnnnnnccnnnonccnnccnrnrcn cc 10 Fire Alarm Syst m NOUUG 000 11 To Enable the Control Panel Keys ooooicccincccinncicnncccnonccnnonnnonann nac c cnn crnrnnrrn 11 To Manually Operate the Fire Alarm SOUNUEIS oooccccccnnncconocnconcccnonnnn non nono cnn cnn rn 11 Following a Fire Alarm OperatiON oocccnnnccinnniconcccnonccnnnnnnn nan nn noc r cnn 11 Following a Fault Condition oooonnccccccnnnnconoconnncccnonccnn rra narrar cnn 11 A O A TEO 12 Fire Alarm User Notice dsd 13 Engineers NotesS coi in iia 14 Technical SUP O ra ae e ae aaeeea a E a T a id tee dhs 15 TWINFLEX pro Repeater Panel Engineering and Commissioning Manual Introduction This Manual is intended as a guide to the engineering and commissioning principles of the TWINFLEX pro Repeater Panel and covers the system hardware information only Due to the complexity and inherent importance of a system covering a Life Protection Risk training on this equipment is essential and commissioning should only be carried out by competent and approved persons For further details of the availability of commissioning services please contact your supplier System Design gt This document does not cover Fire Alarm system design and a basic understanding is assumed A knowledge of BS5839 Pt 1 2002 Fire Detec
12. tion and Alarm Systems for Buildings is essential It is strongly recommended that a suitably qualified and competent person is consulted in connection with the Fire Alarm System design and that the entire system is commissioned in accordance with the current national standards and specifications Equipment Guarantee gt The equipment carries no warranty unless the system is installed commissioned and serviced in accordance with this manual and the relevant standards by a suitably qualified and competent person or organisation Anti Static Handling Guidelines gt Warning gt Immediately prior to handling any PCBs or other static sensitive devices it is essential to ensure that a personal connection to earth is made with an anti static wrist strap or similar apparatus Always handle PCBs by their sides and avoid touching any components PCBs should also be stored in a clean dry place which is free from vibration dust and excessive heat and is protected from mechanical damage Do not attempt to install this equipment until you have fully read and understood this manual Failure to do so may result in damage to the equipment and could invalidate the warranty For technical support please contact your distributor Do not call the Fike Safety Technology support department unless your distributor has first given their advice and attempted to rectify the issue TWINFLEX pro Repeater Panel Engineering and Commissioning Manu

Download Pdf Manuals

image

Related Search

Related Contents

How to set up a Conference Call Through this user guide we would  Service Manual Model 6400 Cardridge Tape Drive  Husqvarna Z 42" User's Manual  MANUAL DE INSTRUCCIONES REFRIGERADOR  USER MANUAL - AV-iQ  Bedienungsanleitung  MODE D`EMPLOI  Back to Basics BPE3BRAUS User's Manual  L8542874 10/2008 rev 0 UNIONE NAZIONALE COSTRUTTORI  DICHIARAZIONE DI INCORPORAZIONE DECLARATION OF  