User`s Manual
Contents
1. 16 bit 1 64 000 2000 series input and option cards 2011 IN Process input 2000 BASE Base card with power supply 2021 MU Multi input 2000 REL2 Alarm card NO NC 2031 IR Infrared sensor input 2000 REL3 Alarm card Closing contacts 2041 SG Strain gage measurement 2000 OUT Output card U and 2051 PU Scaleable frequency indicator 2000 RS Serial output RS232 or RS485 2061 CO Counter input max 5 kHz 2000 1 0 4 pcs input output ports 2066 SEC Timer function s min h ext 60 V 100 mA 2071 RS Serial input RS232 RS485 2081 BCD BCD Gray binary code input 1 5 digits 11 Manufacturer Nokeval Oy Yritt j katu 12 37100 NOKIA Tel 358 0 3 342 4800 Fax 358 0 3 342 2066 http www nokeval com
2. ALrESE Alarms reset by external contact if user function selected from the reset function ZEro Tare function by external contact or front panel key Tare function resets of that moment display value Tare can be removed by pressing the front panel and keys at the same time NoFILt Lopass filter bypass Use when there is a switch indicating large changes in input value Access code functions Access code can be entered when the display shows Code Access code is formed with AV keys Each time key is pressed line moves from left to right Entering access code mustbe started within 3 second after text Code appears to display Total number of combinations is 4 4096 Note If You enter k x x it means that access code is not used If configuration access code is forgotten the access code can be reset by switching power off and holding down buttons and while connecting power back again Torememberaccesscodebetteritis recommended to give names to buttons 1 A 2 V 3 4 gt This helps You to form codes with numbers e g number 143311 A gt X AA CFCode gt Access code for configuration mode If You feel that You entered wrong code You can enter itagain See detailed instructions above ALCode gt Access code for alarm level mode Must be entered to access into alarm level setting mode from normal measuring mode Teaching potentiometer range CAL gt Select text
3. CAL into display with AW keys Push gt Enter access code kkkkkX Select with AV keys text POt into display and led A1 lits Turn potentiometer into minimum and press gt key for 1 second Select AW text Pot and led A2 Turn potentiometer into maximum position and press gt Exit to main menu with key X 2011 Connections Input output cards Input Output Alarms l Display Hold 6 6 6 6 sa 5 Ne 5 Relay Ai 1 D gt V 4 4 No 4 Com gt 3 3 3 MA Pie 2 Ne Ur Relay A2 24 VDC 11 1 No 1 I En l e wie Slot A Slot B Slot C RE transmitter Slot A is for sensor input and Power supply 85 240 VAC slots B and C for optional cards connectors 7 and 8 grey connector or 24 VDC green connettor 7 and 9 no polarity Voltage current input Potentiometer Potentiometer size 6 6 100Q 10kQ 5 5 4 0 5 10V 4 gt 3 Common 3 2 0 4 20 mA 2 1 1 Open jumper J2 when potentiometer is used 2 wire transmitter External contact 6 6 5 2 wire transmitter 5 4 4 20 mA 4 7 3 al d Dg 2 1 1 Power supply for Slot A transmitter 24 V max 150 mA Sensor supply 24 VDC 50 mA m Common DO O B O 0 24VDC max 50 mA Construction of fi
4. D and display shows aarm level A1 LED blinks to inform that unitis in alarm level stage Second bush lights A2 LED andindicator shows alarm 2 level Third press returns display into measuring stage If buttons are not pressed with in 60 seconds unit returns automatically into measuring stage When A1 or A2 led blinks user can enter edit mode by pressing A or W key Values can be changed as described below Accept change by key Alarm level setting Accept and exit with button Value selection A 400 00 AV Numbers 0 9 Alarm levels are selected with AV buttons one number at a time Changing begins fromthe most signifigant digit on the left decimal point is selected first Next digit to right is selected with button Selecting next digit Cy gt 400 00 Desimal point selection with AV keys before number selection Configuration Configuration can be started by pressing and holding Alarm values can be selectedin configuration mode or and A keys simultaneously for 2 seconds Arrow in measuring mode Hysteresis and alarm type can be keys AV moves up and down in main menu Desired selected only in configuration mode function is selected with key Save mode can be Changes can be restored by selecting text UnDO into selected directly by pushing key in main menu display and pressing key Note Detailed To save and exit push while save is displayed configuration stage descrip
5. EET 9 Input OUtpUt Cards A A nananana naan ana Kaanaa annan annan an nneen 9 Potentiometer ciniti ennenen naamaa a aa Aaa aa ea Kaa ENEE 9 ExternallCOMtaot ege gedoe eebe tate te aad teen maat S 9 Field GIS EE e E 10 2000 series input and option Garde 11 Modular indicator serie 2000 11 Manufacturer Nokeval Oy Yritt j katu 12 37100 NOKIA FINLAND Tel 358 0 3 342 4800 Fax 358 0 3 342 2066 http www nokeval com Field display X 2011 Display hold l transmitter l L Relays 6 Relay A1 N Relay A2 LJ HHH 5 4 3 2 1 Slot C Power supply General Description Indicator X 2011 is designed for general process inputs 0 4 20 mA 0 5 10V and potentiometers 1000 10 KQ Designers main goal has been to achieve a unit with fast introduction time and easy of use Input selection and display scaling can be easily done by front panel keys 4 keys Optional alarm level and hysteresis additional card 2000 REL wtih two NC NO relays can also be easily controlled from indicators front panel X 2011 measuring accuracy is 0 05 FS 15 bits and it is designed for 3 4 digit panel mounted process display When wider span is used display value can be stabilized with freely selectable filter This operation makes it possible to use this indicator even as 5 digit display If larger numerical value is required same time with fast display updating time itis recommended
6. Nokeval No 110507 User s Manual Models 575F 1000F 1100 1800F 2011 for process inputs Contents General Ree e E 3 Fi ldidisplay AE 3 Indicator family 2000 sviin haces aa taen teh cadet ieee Mais 3 Technical specification eee eeceeeeeeeeeeenneeeeeeeeeeeaeeeeeeeeeaaeeeeeeeeenaaeeeeeeeeeeaaes 4 Blue 4 lm TO OA Gnat onen a kaka E Kankaan oku ege dee eg ee e e adeaedeeexsp gad 4 Control panel eege ege oton Oia att Da a as kan e 5 Configuration stage 5 Resetting access Code 0 lt ouu sanonnan amen a aa aava ma TEKI Te INVA EEE Nai 5 Alarm level setting kk 5 Alarm Seting EE 5 eil In E 6 Configuration parameters eceosoussssss saana naan naa a aa iiaia 7 Alar Si area a a eet EE ege eg 7 Dec number of decimals ccccccceececcceceeeeeseeceeeeeeeeeeeceeeeeeeeeeeceeeenensenees 7 Lo Hi display SCALING cccuuuossseses nannaa EENEN nannaa ana NANESTE 7 Ree UC EE 7 Steppass filtet seet Aeefeeere S inaianei hha Naine naiai 7 Dead dead zone around zeng 8 Intens display brigtness ee ceeeceeeeeeeeteeeee aa a a nan naan ana naan a eanet 8 del EE 8 External contact FUNCTION sssini nan aa an naa nana a naan iaa 8 ACCESS Code TUNCTHIONS suinionsssinsnn 0 ness ans na aan a aava ma aN UTAN Aa Nana aii 8 Teaching potentiometer position uuuooososuss naan a nannaa a naan n ennen 8 ENEE 9 Voltage CUITENt iNPUT sssooooooooiin nenne naan aan naan aa nananana naene neen 9 C
7. age input gt 1 MQ 0 05 FS 24 VDC max 50 mA Input resistance Accuracy Sensor supply Potentiometer 1000 10 ko Reference voltage 2 5 V max load current 25 mA Accuracy 0 05 FS Alarms 2 alarms relays max 240 VAC option 2A selectable hysteresis 100 automatic or manual reset selectable direction General Input filter Digital freely selectable AD converter 15 bits 1 32000 Measuring speed 7 meas second Temperature effect 0 005 C Alarm indicators 2 A1 and A2 Power supply 85 240 VAC or 12 30 VDC 22 28 VAC Consumption 12 W without sensor supply F ex 24 VDC 0 5A Case material 575F Dark noryl 1000F 1100F 1800F black metal Terminals 2 5 mm removable Digit size 57 mm 575F 100 mm 1000F and 1100F or180mm 1800F Powersupply 85 240 VAC or 24VDC Case protection IP65 Weight 575F 3kg 1000F 5kg 1100F 8kg 1800F 15 kg How to order XX 575F 1000F 1100F or 1800F Input card XX 2011 REL2 24VDC Alarm card REL2 Supply voltage 85 240 VAC or 24VDC Last parameter always power 24 VDC or 230 VAC Order types doesn t contain optional card symbol 2000 e g 2000 REL2 is specified only REL2 Unit may have one input card and two optional cards Unit can be updated to other input types only by changing the input card and adding needed option cards Optional cards are same for all 2000 series units Alarm card 2000 REL2 REL2 with type code Dimension
8. conds 63 of step change 0 000 no damping 0 500 normal damping 8191 maximum damping Lowpass filter Stpass gt Steppass filter When strong damping see Lopass filter in used ittakes very long for the indicator to settle after large changes in input value This can be elimi nated with steppass filter Normally the unfiltered input value dashed line in the graph fluctuates around the filtered value However after large changes the sign of the difference between unfiltered and filtered value will remain unchanged fora while When this time exceeds the Stpass value in seconds the lopass filter is reset and the indicator will jump to the current input value Steppass filter Ste ppass Dead gt Dead zone around zero If the input reading is smaller than the Dead value the display is rounded to zero This is especially handy in weighing and flow measure ment applications To prevent negative values only set Dead 0 To disable the dead zone set Dead 1 or any negative value Intens gt Display brightness 1 5 st to select accept with factory default 4 5 brightest Input selection Input gt Select input Display Input 4 20mA 4 20mA 0 20mA 0 20 mA 0 5u 0 5V 0 10u 0 10V SPEC Factory settings Pot Potentiometer External contact function Contac gt OFF External contact not ni use Hold Display holding by external closing contact
9. eld display series The field display series is modular and easy to as semble according to customers wishes The basic construction consists of mother board with tree slots A BandC Slot A determines meter type and provides always input signal Slot B and C are interchangeable As factory delivery input signal is always installed into slot A outputinto slot B and alarms into slot C In case of f ex 4 alarms and relay card with 2 change over contact 2 2 relays are used you must place second Allcards have relay card into slot B You can have different types of meters by only changing the input card in slot A Data sheet of each type of meter dictates the possible combinations Recalibration of card is not needed only scaling and other settings must be set using front panel keys calibration memory lt gt pinni p dl 2 37 A p n ul m Ce 8 4 JA T Se PP m E 2 y J m p 14 cal ce m lt nA AM o Pa A ed 4 T lee Slots A C A B c Power supply 12 32 VDC Green connector or 85 240 VAC Grey connector Change of meter type Input cardis placed always to slot A By changing input card you can get an other type of meter You can change meter with pulse input to meter with current input thermocouple strain gage etc Control electronic case Additi
10. es Undo or save changes Save Alarms Alm 1 and Alm 2 gt Level alarm level Hyst hysteresis High level alarm Type Alarm type selection Select one of the following LoNo Low level contact normal open HiNo High level contact normal open LoNc Low level contact normal closed HiNc High level contact normal closed Reset Auto or manual reset User manual reset from front panel or external contact conf menu contac Auto automatic reset Dec gt Number of decimals in display Select 0 4 with AV keys and accept with key When Dec value is negative the corresponding number of last digits is rounded to zero f ex Dec 2 two last digits are always zero Lo Hi gt Display scaling Lo value represents display scaling at4 mA or 0 mA 0V and Hi value which is represents display scaling at 20 mA 10V F ex 4 mA 0 0 and 20 mA 100 0 When value is in display it can be changed by pushing key or continue straight into SAVE mode with x Access code for configuration More information on next page External contact selection OFF External contact not in use HoLd Display holding by closing contact ALrESE Alarms reset by external contact ZEro Tare function NoFiLt Bypassing the filter Calibration See details on potentiometer calibration Lopass gt First order digital lowpass filter for input Functions like a RC circuitdamping variations in the reading Set the time constant in se
11. onalslots Additional cards provide output 4 20 MA alarms serial inter face BCD output etc Meter data sheet dictates possible combinations grey connectors allow line voltage 110 240 VAC relay contacts Hait N Be Power supply There are two different mother boards power supply 85 240 VAC and 12 32 VDC VDC mother board accepts 24 VAC Connectors are colour coded Modular field display series 575F 1800F Display Option cards T Alarm cards 6543 2 1 JE 2 relay card 4 alarm types Topo ed change over contacts DAG 3 relay card closing contacts E 41 0 ports E A Model 2011 Sensor supply 2021 E 2 relays change over contacts a lt 2011 also with remote reset ADC 2 LAW Output cards not for 2011 0 4 20 mA 0 10 V RS232 or RS485 Process inputs model 2011 Input card contains 0 20 mA 4 20 mA microprocessor 0 5 10 V bus control Power supolys Potentiometer 1009 5KQ keys control 85 240VAC or display control 12 32VDC 24VAC Model 2021 contains also process inputs but it can also measure RTD sensors and ther mocouples 2021 has very accurate and fast A D converter
12. s 281 500 670 1045 281 455 625 1025 118 147 210 330 96 120 130 210 10 0 S 10 N o 00 co v Glands Dimensions shown in the order 575F 1000F 1100F 1800F 301 482 650 1030 2xPG11 1000F 1800F metal enclosure 575F plastic enclosure Control panel Conf LED Unit is in configuration mode External contact indicator A3 Alarm relay indicators A1 A2 Arrow buttons AW are used to change numerical values and when moving in menu structure Star key exits selected function Configuration stage Configuration can be started by pressing and holding and A keys simultaneously for 2 seconds Configuration stage is for selecting input display scaling and alarm function NC NO Specified instructions on pages 6 7 Configuration Resetting access code If configuration access code is forgotten the access code can be reset by switching power off and holding down buttons and while connecting power back again Alarm setting If alarm state is secured with access code ALCode it must be entered before user can change view alarm levels See access code setting on page 7 Alarm values can be changed and viewed in measuring stage Other functions must be done in configuration mode Unit has two alarm levels which canbe viewed with gt button After gt press lights A1 LE
13. tion on next page Beginning and A Av on menu keys undo save save Hr Cancel and Quit Save and Exit Auto manual reset User manual reset by front panel key Auto automatic reset Select alarm type low or high LoNo LoNc alarm LoNo LoNc HiNo or HiNc Select hysteresis Set alarm value Setting Select number amount with decimal point AW f ex 125 000 and then Alarm level 2 like alarm 1 gt value AY Decimal selection 4 0 4 Accept by x key twice Set min value of display when input signal is on mimum value f ex 4 mA Return Set maximum value of display when input signal is on maximum level Lowpass filter Steppass filter Dead zone around zero Brightness of display 1 5 Default value 3 Text Inputs Select input type __ 4 20 mA_ 4 20 mA 0 20MmA 0 20 mA 0 5u 0 5V 0 10u 0 10V SPec Special range Pot Potentiometer CONTAC Display holding alarm reset and tare function CFCODE ALCODE Access code for alarms Configuration parameters Toenterintoconfiguration mode press and hold A and keys simultaneously for 2 seconds Save mode can be selected directly by pushing key in main menu otherwise key moves backwards Words printed in italic represent indicators display symbols Undo Save gt Exit configuration mode without saving chang
14. to use indicator model X 2021 Decimal point position is freely selectable Separate access codes for configuration and alarm level control can be selected Display brightness can also be selected via front panel keys Front panel protection is IP65 i e dust and sprinkling water proof There are two alternative power possibilities one for mains voltage 85 230 VAC or 24 VDC Both are galvanically isolated from inputt Indicator can supply 24 VDC 150mA to sensor orto other field equipment Indicator family 2000 Field display X 2011 is apart of a larger product family This series field displays are easy to modificate for different type of inputs e g X 2011 canbe changed for Pt100 thermocouple input simply by changing the input card to type 2021 This kind of modification doesn t require any kind of calibration user only configures the unit with front panel keys When input card is changed it changes also the model type e g if process indicator 2011 is modified for strain gage indicator with 2041 STG input card the model will change to X 2041 This model X 2011 is basic indicator in this series If You require min max value memory more alarm relays temperature input or better accuracy You should use the model X 2021 display Technical specification Processinputs 0 20 mA 4 20 mA 0 5V and 0 10V Range 9999 99999 f ex 4 20 mA 58 500 59 500 span 10 00 Display hold by closing contact current 50 O volt