Home

E-HEART and CARDIOSTART

image

Contents

1. PAUS DEFIB NPI MEDICAL TECHNOLOGIES BIPHASIC DEFIBRILLATORS E HEART CardioStart E e SEI E HEART CardioStart The lightest ONLY 8 82 lbs 4Kg e Perfect match for trolleys and MICU S With the innovative flip down display Shock resistant and anti flame Multiple angles offers greater comfort and safety wherever the patient is e Display Resolution High Resolution Color LCD Easy access to connectors e Weight 9 48 Lb 4 3 Kg Display Resolution High Resolution Color LCD Physical Characteristics Flip down display 7 5 Height 7 In Length 16 In Width 12 In Inches 6 3 In Physical Characteristics e Height 9 In Length 10 In Width 9 In e Inches 7 In 02 GET NEW PRODUCTS CALL US OR ORDER AT www usdefib com OPTIONALS Pulse oximetry with indicator of the spo2 value and programmable alarms for maximum and minimum SPO2 External Transthoracic pacemaker non invasive multi programmable microprocessor Non Invasive Blood Pressure NIBP AED Mode that automatically analyzes cardiac arrhythmias and patient ECG Capnography that uses side stream and mainstream type sensors ETCO2 Protection against defibrillator discharge self test svvitching to emergency mode and override mode Software for drug calculation Software for intubation ventilation mode 360 Joules 7 Y 12VDC connection for MICU DIS MASSIMO TECHNOL
2. permanent paddles interchangeable which requires simultaneous activation of both controls one in each paddle minimizing the risk of accidental shocks Selection of the charge level by APEX PADDLE key it charges by pressing the STERNUM PADDLE key and it triggers the shock by the paddles by simultaneously pressing both paddle keys Clear stages indication charging ready shocking and disarming Patient s thoracic impedance analysis which increases the defibrillation effectiveness and reduces the risk of heart injuries Monitoring the paddles contact on the patient s chest by the Bargraph on the display and on the shock paddles With the equipment powered by the power grid or even powered by new and fully charged battery its charging time is lower or equal to 5 seconds for 200 joules and less than or equal to 6 seconds to 360 joules The charging times can be adjusted by the user if desired Indicator of contact of the paddles with the patient displaying the contact intensity Charge canceled automatically after 30 seconds if there is no triggering or manually by pressing cancel The information canceled appears on the display Clock Timer seconds counter Date and Shock Counter lt performs self diagnostic test when it is turned on It indicates the mode and charge energy on the screen Automatic charge adjustment When in SYNCHRONIZED MODE it triggers the shock synchronized with th
3. 6 07 08 09 10 15 20 25 30 35 40 45 50 for child defibrillation External Paddle and adult internal defibrillation internal paddle and 01 02 03 04 05 06 07 08 09 10 15 20 25 30 35 40 45 50 70 90 100 110 120 150 180 200 Joules for adult defibrillation External paddle 270 Joules Version 01 02 03 04 05 06 07 08 09 10 15 20 25 30 35 40 45 50 for child defibrillation external paddle and internal adult defibrillation internal paddle and 01 02 03 04 05 06 07 08 09 10 15 20 25 30 35 40 45 50 70 90 100 110 120 150 180 200 270 Joules for adult defibrillation External paddle 360 Joules Version 01 02 03 04 05 06 07 08 09 10 15 20 25 30 35 40 45 50 for child defibrillation external paddles and internal adult defibrillation internal paddle and 01 02 03 04 05 06 07 08 09 10 15 20 25 30 35 40 45 50 70 90 100 110 120 150 180 200 240 360 Joules adult defibrillation External paddle Support to fix the paddles and carrying handle part of the case can be used regardless of the housing bag External interchangeable paddles Adult and pediatric multifunctional disposable paddles adult and pediatric for Pacemaker and AED Both monitors and defibrillate Adaptable to any patient it even has an intelligent safety system that limits the charge for internal use and pediatric neonatal use 04 Use of reusable pads adult pediatric
4. OGY Monitoring of carbon monoxide saturation SPCO Monitoring of Metal Hemoglobin SpMET CARDIOSTART amp E HEART FEATURES Patient Analysis System Patient Analysis Automatically analyses the patient thoracic impedance increasing the defibrillation effectiveness and reducing the risk of heart damage Electrocardiogram FEATURES ECG 3 12 Derivations DI DII DIII through 3 way ECG cable and DI Dil DIII aVL aVR aVF and VI to 6 through 5 way ECG cable All derivations Automatic Interpretation of the patient ECG Capture of the ECG signal by the reusable or disposable electrodes or by transthoracic adhesives electrodes of the pacemaker or by their own paddles Heart Rate 10 to 300 bpm Accuracy 01 BPM with numerical display Protection against the defibrillation Numerical indication of heart rate on the display QRS detector Detection and rejection of pacemaker Very High sensitivity to the R wave Capture sensitivity ECG amplification stage 5 10 15 20 30 and 40 mm mV line filter 60 Hz rejection in common mode greater than 90dB Audible and visual alarms loose electrode asystole tachycardia bradycardia fibrillation with digital adjustment Isolation of the patient CF type Defibrillator proof lt performs a periodical self test Trace Freeze lt monitors the paddles impedance Defibrillation Scale 200 Joules Version 01 02 03 04 05 0
5. com DEFIBRILLATORS PARAMETERS NON INVASIVE BLOOD PRESSURE NIBP PAR MEDIZIN TECHNOLOGY GERMANY Systolic diastolic and mean blood pressure measurements by the oscillometric method in adult pediatric and neonatal patients safety and protection in pediatric and neonatal use It presents simultaneous data on the screen manual and automatic operation mode In the automatic mode it is programmable from to 120 minutes Programmable interval for cuff inflating Auto zero before each measurement It has alarm for minimum maximum and average pressure It has sound and visual programmable alarms that are triggered automatically when you exceed the upper and lower limits of the adjusted values for blood pressure and heart rate and it has 03 priority levels Range of blood pressure measurement up to 300MMhG Range of heart rate measurement from 30BPM to 250BPM CAPNOGRAPHY ETCO2 RESPIRONICS TECHNOLOGY USA The capnography module uses the sensor Side stream and Mainstream miniaturized type After connecting the sensor itis necessary to wait for approximately minute for the set to be ready for measurements After this time you should see a light on the sensor indicating their qualification Once connected to the respirator tube it shows the patient information The capnography sensor should be placed over the adapter to prevent condensation if it occurs it will interfere with the reading measurement Ca
6. e QRS complex with the energy delivery time lt 20ms Maximum delay time for signal stabilization 5 seconds after ideal connection of the sensor to the patient When BIPHASIC DEFIBRILLATOR MONITOR is set in automatic mode the energy charge follows a triggering sequence of 50 200 and 200 Detection and rejection of pacemaker pulse Impedance detection in the range of 25 Ohm to 50 Ohm for the shocks Displays all programming parameters beep indicator battery status etc Internal memory including curves date and time of approximately 250MB or more which corresponds to more than 100 hours of continuous recording Enables continuous ECG critical events and procedures to be recorded in the memory Memory card allows communication with PC through connection for viewing memory data Enables the posterior reading of the ECG trace of memory of events through hardware and or specific software optional GET NEW PRODUCTS CALL US OR ORDER AT www usdefib com CARDIOSTART amp E HEART FEATURES Battery Pack Type Lithium Manageable rechargeable internal battery e Interchangeable and it can be replaced by the user internal protection fuses charging alarm indicators e Capacity 220 Shocks 200 J or 10 hours continuous operation with full battery e Standby life 5 years e Charging time 4 Hours e Power Automatic 00 240 full range optional e 50hz and 60hz or directly from the ambulance batter
7. munity to transients and external electromagnetic fields High mechanical resistance to vibration Technical specifications are subject to change without previous notice 05 GET NEW PRODUCTS CALL US OR ORDER AT www usdefib com DEFIBRILLATORS PARAMETERS PRINTER High Resolution thermal printer with manual and automatic modes one channel optional two channels Paper size 48mm X 20mm approx Paper speed 12 5 25 50 mm sec High Resolution with registration on the occurrence of each triggering AED MODE AUTOMATIC ANALYSIS SYSTEM Automatic ECG evaluation which detects QRS complexes and automatically identifies malignant arrhythmias ventricular tachycardia and ventricular fibrillation that require defibrillation It features voice and text command on the display to instruct the rescuer during the resuscitation sequence Optional Pediatric Pads 06 EXTERNAL PACEMAKER The external pacemaker was designed to stimulate the heart in case of disturbances in the rhythm and internal faults in the conduction of its electric impulse It is used in cardiac surgery as an emergency cardiac pacemaker Some transthoracic applications for the pacemaker are indicated for Treatment of symptomatic bradycardia or bradiasystoly during emergency and during and after cardiac surgery to facilitate the insertion of a transvenous stimulator electrode External pacemaker transthoracic non invasi
8. pnography Functional Specifications Expired CO2 curve shown continuously on the screen Optional self calibration procedure that exempts the use of specific gases for periodical calibration value of expired CO2 minimum inspired CO2 and a value of respiratory rate continuously displayed on the screen e Miniaturized sensor with self calibration Optional clamp cuff hose adult pediatric and neonatal 2 Ok PULSE OXIMETRY SPO2 Plethysmographic curve indication and values of oxygen saturation and pulse rate shown on the numeric display and in percentage Em plethysmographic wave amplitude adjusted on the screen it has full alarm system and audible and visual indication of the 5802 level through the tone of pulse signal the volumes of alarms and audible pulse indicator are independently adjustable adjustable audiovisual alarm low and high SPO2 and low and high heart rate bradycardia and tachycardia alarm pulse not detected sensor disconnected searching for pulse silencing the alarm for 02 minutes key good response at low perfusion Sampling range approximately 70 to 100 Accuracy of 3 The accuracy of the measured saturation is indeterminate when it is between 0 and 69 Optional adult SPO2 sensor clip child clip universal Y clip and ear clip 07 MEDICAL TECHNOLOGIES CERTIFICATIONS Ce sas 0120
9. ve multiprogrammable on the DEMAND modes Asynchronous fixed and Emergency Control of the process of stimulation through the Defibrillator keyboard The application of stimulation pulses can be displayed by a LED on the panel It is possible to set the pacemaker in three different modes of operation VOO VVI and Emergency InVOO and VVI modes the pacemaker will be stimulating and transmitting information to the display amplitude width frequency and mode Stimulation current without charge connected 200mA Off OmA ECG Uptake by the adhesive paddles output stimulation adhesive electrodes PADDLE s Frequency one can vary the frequency of stimulation between 30 and 200 ppm Amplitude the amplitude value can be set between 5 and 200mA Width You can select pulse widths between 5 and 50ms 25 Specification of the stimulation system Stimulation frequency 30 ppm to 200 ppm at ppm steps Pulse amplitude OmA to 200mA in mA steps Pulse width Oms to 50ms in ms steps Emergency VOO 70 ppm 100mA 20ms Defibrillation discharge protection up to 400 Joules The above specifications frequency amplitude and pulse width can be changed when requested by the user Pacing Mode Demand emergency fixed rate Pacing Rate ppm 30 200 ppm Output current mA 0 to 200 mA Pulse Width m sec 0 50 m sec ECG Recorder Yes Gus GET NEW PRODUCTS CALL US OR ORDER AT www usdefib
10. y 2 Vdc e Index of protection IP22 All accessories necessary for the perfect functioning of the equipment followed in all the parameters configured User Manual and Warranty Certificate Controls and Indications Indication of paddle contact Timer Clock seconds counter e Shock counter Text and voice command whether or not a shock is advised Language English Possibility to change language through software Accessories Professional 3 lead power cord Ol set of adult reusable electrode paddles Interchangeable adult pediatric Ol set of 3 5 lead patient cable Ol conductive gel Ol transportation bag e User manual and warranty certificate and more accessories for the perfect performance of the equipment Extra Accessories Internal Pads Data Recording and Transmission It provides through connection communication with microcomputer to display e Memory data optional Memory for event filing DS u tt Optional Accessories Disposable pacemaker transthoracic electrodes Adult pediatric neonatal oximetry sensor Capnography kit Cuff and hose for NIBP measuring Environmental Temperature 40 to 70 Relative Humidity 10 to 100 Atmospheric Pressure 500 pHa through 1060 hPa 525 mmHg through 795 mmHg Shock and Water Resistance Protection Level IP 22 Airplanes Low level of electromagnetic field radiation e High im

Download Pdf Manuals

image

Related Search

Related Contents

取扱説明書 - オークセール  USER`S MANUAL - Tyconpower.com  ESP Ultima Zone Controller Manual LM-ZC  Pioneer DVR-K15VA  Foglio Istruzioni  MANUAL DEL PROPIETARIO  G-Stomper User Manual - PLANET  Fujitsu Service Pack, 3Y, On-Site  Sweex USB Internet Phone with Display  February~March 2013 - The Daimler Lanchester Owners Club in  