Home
Manual - Microh
Contents
1. MIEROF PROFESSIONAL PRODUCTS WWW IMICPONPPO COMmM USER MANUAL LED STAR DRAPE Keep this manual for future reference TABLE OF CONTENTS 1 INTRODUCTION AND UNPACKING 1 2 SAFTEY INSTRUCTIONS 1 2 3 OPERATION INSTRUCTIONS 2 4 4 MOUNTING AND INSTALLATION 4 5 5 DMX 512 CONTROL CONNECTIONS 5 6 MENU NAVIGATION 6 7 7 DMX CHANNELS 8 8 KEY FEATURES 9 9 TECHNICAL SPECIFICATIONS 9 10 MAINTENANCE AND CLEANING 10 1 INTRODUCTION AND UNPACKING Thank you for purchasing the MICROH LED STAR DRAPE For your own safety and knowledge please read this manual before installing or operating the device This manual covers the important information on installation and applications Please install and operate the fixture according to instructions Meanwhile please keep this manual for future reference The MICROH LED STAR DRAPE is made of a cotton velour base for the front and a polyester nylon based material for the backing and is fire treated for event use The fixture is designed and manufactured strictly following CE standards complying with international standard DMX512 protocol This fixture is applicable but not limited to large scale live performances theater studio nightclubs and discos The MICROH LED STAR DRAPE uses powerful TRI 3in1 LED s which feature high brightness and stability Please carefully unpack it when you receive the fixture and check if it was damaged during the transportation And please check whet
2. DIMENSIONS 13 x 19 5 396 x 594 cm NET WEIGHT 37 1 lbs 16 83 kgs WARRANTY 1 Year Limited Warranty 10 MAINTENANCE AND CLEANING The following points have to be considered during the inspection 1 All screws for installing the device or parts of the device must be tightly connected and must not be corroded 2 There must not be any deformations on the housing colour lenses fixations or installation spots ceiling suspension trussing 3 Mechanically moved parts must not show any traces of wearing and must not rotate with unbalances 4 The electric power supply cables must not show any damage material fatigue or sediments Further instructions depending on the installation spot and usage must be handled by a skilled installer or technician Any safety issues must be resolved CAUTION DISCONNECT POWER BEFORE SERVICING In order to keep the fixture in good condition and extend the life we suggest regular cleaning to the fixture 1 Clean the inside and outside lens each week to avoid the light output from darkening due to accumulation of dust dirt etc 2 Clean the fan each week 3 A detailed electrical check by approved technician every three months is advised Ensure the circuit contacts are in good condition and prevent from overheating 4 Do not machine wash Professional dry clean only Flame Retardant Duration 10 Washes We recommend a frequent cleaning of the device Please use a moist lint free cloth
3. Never use alcohol or solvents There are no serviceable parts inside the device Please refer to the instructions under Installation instructions Should you need any spare parts please order genuine MICROH parts from your local dealer IF YOU SHOULD EXPERIENCE ANY PROBLEMS OR ISSUES PLEASE CONTACT MICROH PROFESSIONAL PRODUCTS BY EMAIL AT info microhpro com In the event that your unit is defective in any way please contact your local dealer to obtain an RA number for service repair DISCLAIMER MICROH believes that the information contained within this user manual is accurate However Microh is not responsible for any error or addendums to this manual If you have any comments or general suggestions on how this manual can be improved please contact info microhpro com Thank you 10 PROFESSIONAL PRODUCTS www microhpro com
4. UTPUT CONTROLLER FIXTURE 1 FIXTURE 2 FIXTURE 3 us LA MIA UP TO 30 UNITSIN MASTER SLAVE MODE M MSS NS SN o ctr tr c XLR CABLE XLR CABLE XLR CABLE DMX Output DMX Input COMMON 3 Pin XLR Socket 3 Pin XLR Socket mou SPI For installations where the DMX cable has to run a long distance or is in an electrically noisy environment it is recommended to use a DMX terminator This helps in preventing corruption of the digital control signal by electrical noise The DMX terminator is simply an XLR plug with a 120 O resistor connected between pins 2 and 3 which is then plugged into the output XLR socket of the last fixture in the chain Please see illustrations below 1209 3 1 PIN 3 PIN 2 dd uM SINN EN ALL Abe ZEIT mm Pag DMX 24 CH Mode Fu Fri J LIE DMX 32CH Mode eM Green dimmer Fir NE L Blu Blue dimmer Blue dimmer sn nana Moown Menu Y Slog E COLA BOLA Sound Chase Nasen 7 DMX CHANNEL MODE 1 channel A Bris Chanel Fundtien Pescoription q BDimmer LED Macro Effect 1 Macro Effect 2 Macro Effect 3 Macro Effect 4 Macro Effect 5 Macro Effect 6 Macro Effect 7 Macro Effect B Macro Effect 9 Macro Effect 10 Macro Effect 11 Macro Effect 12 Macro Effect 13 Macro Effect 14 Macro Effect 15 Speet of Effect Macro intensity 2 Macro Effect 3 Effect Speed MODE 2 24Channel p EP C132 Charel Func
5. he device is not in use or before cleaning it Never pull out the plug by tugging the power cord During initial start up some smoke or smell may arise This is a normal process and does not necessarily mean that the device is defective It should decrease gradually Please do not project the beam onto combustible substances Fixtures cannot be installed on or near combustible substances Keep more than 50cm distance from wall for proper ventilation and air flow If your fixture is or has become damaged in any way it shall be exclusively replaced or repaired by the manufacturer to avoid any hazard CAUTION Never touch the device during operation The housing may heat up CAUTION Never look directly into the light source as sensitive persons may suffer an epileptic shock CAUTION The electric connection must only be carried out by a qualified electrician 3 OPERATION INSTRUCTIONS Do not turn on the fixture if it has been through severe temperature differences Damage may occur to the fixture Wait until unit is at room temperature to operate The unit should be protected from any tremor or agitation during transport Do not expose the fixture in any excessive heat moisture or any environment with too much dust when installing Do not lay any power cables on the floor It may cause electronic shock or damage to persons or equipment Make sure to attach the safety chain and ensure the screws are properly screwed in
6. her the following items are included inside the box Drape One Power Cord One 5 Pin Control Cable One Controller 1 User Manual One 2 SAFTEY INSTRUCTIONS CAUTION ELECTRIC SHOCK WARNING USE EXTREME CAUTION WHEN HANDLING WIRES This device has left the factory in perfect condition In order to maintain this condition and to ensure safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual IS Important Damages caused by the disregard of this user manual are not subject to warranty The dealer will not accept liability for any resulting defects or problems If the device has been exposed to temperature changes do not switch it on immediately The arising condensation could damage the device Leave the device switched off until it has reached room temperature and is dry This device falls under protection class l therefore it is essential that the device be grounded The electrical connection must be carried out by a qualified technician The device should only be used with rate voltage and frequency Make sure that the available voltage is not higher than 120V as stated at the end of this manual Make sure the power cord is never crimped or damaged in any way as this could cause shock and damage If your power chord is damaged in any way please purchase a new cable from your local MICROH dealer Always disconnect power when t
7. nd 15 being the fastest STROBE FLASH To apply strobe FLASH to one of the auto modes select FLxx from the main menu and use the UP and DOWN buttons to select your desired flash rate from 1 to 15 1 being the slowest and 15 being the fastest Bg Manual mode f rr L i Red dimmer 2 gii Green dimmer 3 bL iG Blue dimmer B Auto mode 1 FLI i5 Flash 2 FR IS Automatic fade in and fade out 3 AG fe Auto change 7 color 4 LEIG Chasetignts 5 E Gi 15 Chase lights speed E Sound control mode 1 E LI TJ El Sound Chase lights 2 c QUE 25 Sound 7 color flash 3 SENS Se00 se15 Synchronization mode master and siave 1 Master light Choose same as manual auto sound control mode wav 2 Ali slave lights AOG x 4 MOUNTING AND INSTALLATION Caution For added protection mount the fixtures in areas outside walking paths seating areas or in areas were the fixture might be reached by unauthorized personnel Before mounting the fixture to any surface make sure that the installation area can hold a minimum point load of 10 times the device s weight Fixture installation must always be secured with a secondary safety attachment such as an appropriate safety cable Never stand directly below the device when mounting removing or servicing the fixture Whether installing inverted on a truss or ceiling Be sure this fixture is kept away from any and all flammable materials decoration etc Always use and install the sup
8. plied safety cable as a safety measure to prevent accidental damage and or injury in the event the mounting fails Mounting Points Overhead mounting requires extensive experience including calculating working load limits A knowledge of the installation material being used and periodic safety inspection of all installation material and the fixture are all imperative and should only be performed by a qualified technician Improper installation can result in bodily injury and damage Be sure to complete all rigging and installation procedures before connecting the main power cord to the appropriate wall outlet Picture of back of unit hung with pipe amp drape Regardless of the rigging option you choose for your MICROH LED STAR DRAPE always be sure to secure your fixture with a safety cable The fixture provides a built in rigging point for a safety cable on the hanging bracket as illustrated above Be sure to only use the designated rigging point for the safety cable 5 DMX 512 CONTROL CONNECTIONS This fixture complies with international USITT DMX standards and can be used with either a 3 pin or 5 pin DMX connector Plug in the provided 3 pin XLR cable to the female 3 pin XLR output of your controller and the other side to the male 3 pin XLR input of the LED STAR DRAPE To connect the units to DMX you must daisy chain the fixtures together as referred in the diagram below Always end your DMX 512 connection with a DMX terminator DMX O
9. ress is set leave the unit powered on for 3 minutes in order to store the address within the unit so that it returns to that address when powered off on SOUND ACTIVE MODE From the main menu select either SOUA or SOUF SOUA mode with chase randomly through the internal programs activated by sound SOUF mode will chase through 7 individual full bar colours To adjust the audio sensitivity select SEnS from the main menu and press ENTER Using the UP and DOWN buttons select number 0 through 15 0 being the lowest and 15 being the highest sensitivity MANUAL MODE From the main menu select rLXX gLXX and bLxx and use the UP and DOWN buttons to adjust each individual colour from numbers 0 through 15 0 being off and 15 being the full intensity This will create a custom colour mix of your choosing COLOUR FADE From the main menu select FAXX and use the UP and DOWN buttons to select the speed of the colour fade AUTO COLOUR CHANGE 7 COLOUR CHANGE From the main menu select ASXX and use the UP and DOWN buttons to select the speed of colour change 0 being the slowest 15 being the fastest CHASE MODE From the main menu select CEXX and use the UP and DOWN buttons to select your desired chase from numbers 1 through 15 To adjust the speed of the chase select CSXX from the main menu and use the UP and DOWN buttons to select speeds 1 to 15 1 being the slowest a
10. tien Bo crietier 1 u LED Color Red LED intensity o 2 LED Color Green LED intensity _ 3 d LEO Color PE Blue e LED i Ja LED intensity 22 LED Cotor Red LED intensity 23 LED Color Green LED intensity 24 LED Color Bive LED intensity MODE 3 32Channel F An Strobe slow tofast x Chanel Functien 1 Dimmer Dimmer full On 2 LED Color Red LED intensity _ 3 LED Color Green LED intensity 4 LED Color Blue LED intensity Dimmer gt 29 Diner Strobe slow tofast Dimmer full on Red LED intensity Green LED intensity Blue LED inten sity LED Color LEO Color LED Color sra lts e D LX E amp o a 5 5 S za ls m O 22 0 25 O 5 5 C 2 5 5 D ZT amp amp mmo e Value O ez q 8M ID Lo Ze a D gt Ss O Im 5 CO Ss Os C LIE SS Oo 15 gt 4 6 Gs 2 212 So 2 O zum o zss 8 KEY FEATURES 128 x Watt 5mm Tri Colour SMD 50 50 LEDs 9 XLR Input amp Output PowerCon AC Input All Metal Grommets on all 4 Sides for Mounting Heavy Duty Velcro to Attach Multiple Drapes for Seamless Look Digital 4 Button Display Stand Alone Master Slave DMX amp Auto RGB Infinite Colour Mixing Possibility Effects RGB Colour Mixing Strobe Bright Burst Effect Auto Programs Includes Controller and Control Cable 9 TECHNICAL SPECIFICATIONS LAMP 128 x V4 Watt 5mm Tri Colour SMD 50 50 LEDs VOLTAGE 120VAC 60Hz FUSE 250VAC 2A MAX 240W
11. when installing the fixture Make sure the lens is in good condition It is recommended to replace the unit if there are any damages or severe scratches Make sure the fixture is operated and installed by qualified personnel Keep the original packaging in case of defective product Any non manufacturer additions modifications or changes in any way will void all warranty Please do not attempt to open unit It is only to be serviced by an authorized technician If this occurs or is apparent the warranty will be voided The fixture s warranty will be voided if there are any malfunctions from not following the user manual or any illegal operation shock short circuit electronic shock lamp broke etc This fixture is equipped with 6 operating modes Master Slave DMX Sound Active Manual Mode Colour Fade and Colour Chase MASTER SLAVE MODE By connecting either the 3 or 5 pin DMX you can daisy chain up to 30 units on master slave mode Daisy chain the fixtures together by plugging from the DMX output of the first fixture into the DMX input of the second fixture and so on On your Master fixture set the unit to SOUND MANUAL COLOUR FADE or COLOUR CHASE control and select one of the internal programs All slave lights must be set A001 DMX From the main menu select ADDR and press ENTER By using the UP and DOWN buttons you can set the DMX address Press ENTER when number is reached Once the add
Download Pdf Manuals
Related Search
Related Contents
1 Premere - Aerne Menu PureLink PI090 MANUEL D`INSTRUCTIONS - MRC NextBase Click 7 Lite Duo Deluxe User Guide--Creating Custom Event Prints MANUAL DE INSTRUCCIONES User Manual - Comkit Online Instructions de service Copyright © All rights reserved.
Failed to retrieve file