Home

migra SC/MC 5/3 Profinet User`s Manual

image

Contents

1. frame DA static 0x206 6 0x80 MIGRA frame SA static 0x207 7 0x81 MIGRA frame FC with response 0x208 8 0x56 V 0x209 9 0x3D 0x20A 10 0x30 0 0x20B 11 0x30 0 0x20C 12 0x30 0 0x20D 13 0x31 T 0x20E 14 0x32 2 0x20F 15 0x33 3 0x210 16 0x03 MIGRA frame ETX static Profinet Input Data HMS Profinet Con Description memory input tent address index 0x000 0 Ox9F Status register HIGH without meaning 0x001 1 0 Status register LOW without meaning 0x002 2 x Trigger byte Is increased by 1 value after the reception of every response frame after en x 1 tries into index 3 9 have been done 0x003 3 6 Length byte response length 0x004 4 0x02 MIGRA response STX static 0x005 5 0x80 MIGRA response DA static 0x006 6 0x81 MIGRA response SA static 0x007 7 0x80 MIGRA response FC static 0x008 8 0x30 MIGRA response 0 no error 0x009 9 0x03 MIGRA response ETX static Page 7 microSYST Systemelectronic GmbH Zur Centralwerkst tte 10 DE 92637 Weiden 49 961 39166 0 49 961 39166 10 info microsyst de www microsyst de micro SYST migra SC MC 5 3 Profinet Large Format Graphics Compatible Display with Profinet Interface 2 4 Configuration via RS232 The interface is already pre configured at the delivery Normally the customer does not have to do anything
2. here Anyhow if there are any changes desired it can happen with the Win dows PC software ABC Config Tool of HMS at the compact disc The connection between PC and interface must be done with a null modem cable pin 2 3 pin 3 2 pin 5 5 with 9 pole SUB D socket connector at both ends Start the ABC Config Tool after installation Press the button Cancel of the dialog Konfiguration Open the file HMS MIGRA cfg which you can find at the compact disc The standard Profinet output data width is 68 bytes the input data width is 27 bytes You can use any input output width which must be adjusted with the ABC Config Tool then You can change the Profinet output data width with the entry field Subnetzwerk MIGRA Produce 1 VariableDataObject Maximum Data length It is 3 Maximum Data length gt Standard 68 bytes Gerate Konfiguration x Fa Alphabetisch Kategorisiert Subnetzwerk E General T MIGRA Data location 00203 EJ Produce 1 BERNIE Ox0041 Of VariableD ataDbiect El Operations Consume 1 Byte swap No swapping Of VariableData0bject End Character Value 0x00 Cill tan nand Ditka NiasbKlad Note MIGRA frames must no be longer than 235 bytes gt Maximum Data length lt 236 0x00EC gt Profinet output data width lt 239 bytes Page 8 microSYST Systemelectronic GmbH Zur Centralwerkst tte 10 DE 92637 Weiden Z 49 961 39166 0 49 961 39
3. the l frame is executed with an increasing x 1 by 1 value after the entries in index 3 17 have been done 0x203 3 14 Length byte frame length 0x204 4 0x02 MIGRA frame STX static 0x205 5 0x81 MIGRA frame DA static 0x206 6 0x80 MIGRA frame SA static 0x207 7 0x80 MIGRA frame FC without response 0x208 8 0x6D m 0x209 9 0x69 0x20A 10 0x63 C 0x20B 11 0x72 f 0x20C 12 Ox6F 0 0x20D 13 0x53 0x20E 14 0x59 ER Ox20F 15 0x53 S 0x210 16 0x54 F 0x211 17 0x03 MIGRA frame ETX static Page 6 microSYST Systemelectronic GmbH Zur Centralwerkst tte 10 DE 92637 Weiden Z 49 961 39166 0 49 961 39166 10 info microsyst de www microsyst de micro SYST migra SC MC 5 3 Profinet Large Format Graphics Compatible Display with Profinet Interface 2 Variable 000 shall be set with the value 123 with response Profinet Output Data HMS Profinet Con Description memory output tent address index 0x200 0 0 Control register HIGH Fest auf 0 0x201 1 0 Control register LOW Fest auf 0 0x202 2 x Trigger byte The transmission of the frame is executed with an increasing by x 1 1 value after the entries in index 3 16 have been done 0x203 3 13 Length byte Frame length 0x204 4 0x02 MIGRA frame STX static 0x205 5 0x81 MIGRA
4. 166 10 info microsyst de www microsyst de micro SYST migra SC MC 5 3 Profinet Large Format Graphics Compatible Display with Profinet Interface You can change the Profinet input data width with the entry field Sub netzwerk MIGRA Consume 1 VariableDataObject Maximum Data length It is 3 Maximum Data length gt Standard 27 bytes Gerate Konfiguration x on Alphabetisch Kategorisiert w Subnetzwerk E General T MIGRA Data location 00003 E Produce 1 Reece 0x001F E Variable ataDbiect El Operations 5 2 Consume 1 Byte swap No swapping of VariableD ata bject End Character Value 0x00 Fill mancad Rutas Mieahlard Note MIGRA response frames are currently not longer than 23 bytes gt Maximum Data length 24 0x0018 gt Profinet input data width 27 bytes If you renounce the commands ESC D and ESC P the MIGRA re sponse frames have a constant length of 6 bytes gt Maximum Data length 7 0x0007 gt Profinet input data width 10 bytes Please do not change any other parameters in addition to the de scribed ones If you are not sure contact the technical support of microSYST Please do the following steps in order to save the changed configuration Click the symbol Verbinden g Click the symbol Download zum ABC S After transmission is finished click Verbindung trennen g Si Page 9 microSYST Systemelectroni
5. alue after the reception of every response frame 0x003 3 6 23 Length byte response length 0x004 4 0x02 MIGRA response STX static 0x005 5 0x80 MIGRA response DA static 0x006 6 0x81 MIGRA response SA static 0x007 7 0x80 MIGRA response FC static 0x008 8 XX MIGRA response Data unit 1 Byte 0x009 9 XX MIGRA response Data unit 2 Byte 0x00A 10 XX MIGRA response Data unit 3 Byte ss XX ais 0x008 8 n 1 XX MIGRA response Data unit n Byte n 1 0x008 n 8 n 0x03 MIGRA response ETX static max OxO1A_ max 26 Note In many cases you do not need the response frame The necessary frame intervals which depend on the effort for the eva luation can also be defined as an experiment Page 5 microSYST Systemelectronic GmbH Zur Centralwerkstatte 10 DE 92637 Weiden 49 961 39166 0 49 961 39166 10 info microsyst de www microsyst de micro SYST migra SC MC 5 3 Profinet Large Format Graphics Compatible Display with Profinet Interface 2 3 Examples 1 The online text microSYST shall be shown at the display with out response Profinet Output Data HMS Profinet Con Description memory output tent address index 0x200 0 0 Control register HIGH static 0 0x201 1 0 Control register LOW static 0 0x202 2 X Trigger byte The transmission of
6. c GmbH Zur Centralwerkstatte 10 DE 92637 Weiden T 49 961 39166 0 49 961 39166 10 info microsyst de www microsyst de micro SYST migra SC MC 5 3 Profinet Large Format Graphics Compatible Display with Profinet Interface 3 Connector Pin Assignments RS232 connector of the MIGRA Configuration and controlling the MIGRA 9pol Sub D plug connector Pin RS232 RS485 Standard at displays with more the 64 pixels in height O e O O O Rel Po no O ON O 5 VDC SSS Rein O Er only if an external bus termination is needed RS232 connector of the HMS Profinet interface Configuration of the Profinet interface 9pol Sub D connector Pin RS232 RS232 Plug Connector Socket Connector Standard original HMS cable Page 10 microSYST Systemelectronic GmbH Zur Centralwerkst tte 10 DE 92637 Weiden 49 961 39166 0 49 961 39166 10 info microsyst de www microsyst de micro SYST migra SC MC 5 3 Profinet Large Format Graphics Compatible Display with Profinet Interface Profinet connector of the HMS Profinet interface Controlling the MIGRA via Profinet Profinet socket Assignment Page 11 microSYST Systemelectronic GmbH Zur Centralwerkst tte 10 DE 92637 Weiden 49 961 39166 0 49 961 39166 10 info microsyst de www microsyst de micro SYST migra SC MC 5 3 Profinet Large Format Graphics Compatible Display with Profinet Interface 4 Versions Overview De
7. cessary configuration software Alter natively you can find the files at the home page of HMS www anybus com The connectors for the configuration RS232 and the controlling via Profinet are accessible from the outside 2 1 Linking to a Profinet IO Controller The linking to the PLC of the Profinet side is described in the document PROFINETIO_Slave_Step7_1 10 pdf example for Siemens S7 Alternatively the IP address subnet mask etc can be adjusted with the IP Config Tool of HMS compact disk Page 3 microSYST Systemelectronic GmbH Zur Centralwerkstatte 10 DE 92637 Weiden 49 961 39166 0 49 961 39166 10 info microsyst de www microsyst de micro SYST migra SC MC 5 3 Profinet Large Format Graphics Compatible Display with Profinet Interface 2 2 Transmission of the MIGRA frames The frames which are described in the user s manual migra SC MC 5 3 Serial 02 81 80 8X DATA Unit 03 must be entered in the Profi net output data as follows HMS Profinet Con Description memory output tent address index 0x200 0 0 Control register HIGH static 0 0x201 1 0 Control register LOW static 0 0x202 2 XX Trigger byte The transmission of the frame is executed with an increasing by 1 value 0x203 3 6 64 Length byte frame length 0x204 4 0x02 MIGRA frame STX static 0x205 5 0x81 MIGRA frame DA static 0x206 6 0x80 MIGRA
8. frame SA static 0x207 7 0x80 MIGRA frame FC or 0x80 without response 0x81 0x81 with response 0x208 8 XX MIGRA frame Data unit 1 Byte 0x209 9 XX MIGRA frame Data unit 2 Byte 0x20A 10 XX MIGRA frame Data unit 3 Byte oe XX ue 0x208 n 1 8 n 1 XX MIGRA frame Data unit n Byte 0x208 n 8 n 0x03 MIGRA frame ETX static max 0x243 max 67 The length byte and the MIGRA frame must be entered first Then the trigger byte must be increased by 1 value Thereby the entered frame is transmitted to the MIGRA If the controlling happens without response frame FC 0x80 the re spectively next frame must be sent approx 100 to 200 ms soonest If you use the response FC 0x81 the respectively next frame must be sent soonest after receiving the response Page 4 microSYST Systemelectronic GmbH Zur Centralwerkstatte 10 DE 92637 Weiden 49 961 39166 0 49 961 39166 10 info microsyst de www microsyst de micro SYST migra SC MC 5 3 Profinet Large Format Graphics Compatible Display with Profinet Interface A possible response appears in the Profinet input data HMS Profinet Con Description memory input tent address index 0x000 0 Ox9F Status register HIGH without meaning 0x001 1 0 Status register LOW without meaning 0x002 2 XX Trigger byte Is increased by 1 v
9. migra SC MC 5 3 Profinet Large Format Graphics Compatible Display with Profinet Interface User s Manual microSYST Systemelectronic GmbH Zur Centralwerkstatte 10 DE 92637 Weiden 49 961 39166 0 49 961 39166 10 info microsyst de www microsyst de micro igra SC MC 5 3 Profinet Large Format Graphics Compatible Display with Profinet Interface Index 1 GENERAL 3 2 PROFINET INTERFACE 3 2 1 Linking to a Profinet IO Controller 3 2 2 Transmission of the MIGRA frames 4 2 3 Examples 6 2 4 Configuration via RS232 8 3 CONNECTOR PIN ASSIGNMENTS 10 4 VERSIONS OVERVIEW 12 Page 2 microSYST Systemelectronic GmbH Zur Centralwerkstatte 10 DE 92637 Weiden 49 961 39166 0 49 961 39166 10 info microsyst de www microsyst de micro SYST migra SC MC 5 3 Profinet Large Format Graphics Compatible Display with Profinet Interface 1 General This display is based on the migra SC MC 5 3 Serial which is ex panded by a Profinet interface The interface is used for the connection to a Profinet controller PLC at one side and the data exchange RS485 frames to the display The frames for the display correspond to those of the serial MIGRA and are described in the user s manual migra SC MC 5 3 Serial 2 Profinet Interface The internal interface is the Anybus Communicator for PROFINET of the company HMS AB7013 B At the enclosed compact disc you can find the documentation and the ne
10. scription 1 00 05 03 2008 Nickl Document created Certified per DIN EN ISO 9001 2000 Page 12 microSYST Systemelectronic GmbH Zur Centralwerkst tte 10 DE 92637 Weiden 49 961 39166 0 49 961 39166 10 info microsyst de www microsyst de

Download Pdf Manuals

image

Related Search

Related Contents

ビーポップ  Home Decorators Collection 0815200260 Instructions / Assembly  USER GUIDE HDDVR186  Philips SMARTSPOT Recessed spot light 59683/31/16  ABRE-PUERTAS DE GARAJE Modelo 3585 3/4 HP  Johnson Hardware 100FD Series User's Manual  Manuale d'uso e manutenzione Compressore K13090 User Guide  TP-Link T3700G-28TQ User Guide  INSTRUCTIONS FOR USE FOR C    