Home
        UET Series Torque Analyzer Operations Manual - aimco
         Contents
1.  Kgf m  KgfCm  gfCm   cNm  Nm and FTLB      Using the    A C    button  select time for AutoClr or turn off  this automatically clears the display after  selected time  press enter after selection         If not using AutoClr  press the    CLR    button to clear display        Table of Contents         Introduction  e Features      Clockwise and Counterclockwise Operation      Components  e Buttons     Off  amp  On Zero  e Unit IO Connections     DC In    Keylock    RS 232    e Other Components      Batteries    Rundown Fixtures    RS 232      Setting Modes  e Peak   e 1    Peak   e Track      Setting Engineering Units      Setting AutoClr      Programming    e Set Filter  e Sleep Mode  e Lock Out Mode      Calibration    Page  Number    WWW LU NNN D NY NY N IA    A A A  R    Nn NM    D N N N    00       Introduction       Thank you for purchasing the UET Series torque testers from AIMCO  We sincerely appreciate your business     The UET Series instruments demonstrate AIMCO   s ongoing pursuit of product excellence and total customer  satisfaction     The AIMCO Universal Electronic Tester is designed specifically for the requirements of today   s production  facilities  Small  portable  accurate  durable  and most importantly  this tester is very easy to use     Please read through this manual prior to using your tester and if you have any questions  please call us at    800  852 1368 for Customer Service     Features   e Keylock security   e RS 232 data output   e Simple  on
2.  Unused  5 Ground       November 2006  3        Setting Modes       The AIMCO UET Series Testers support three modes of operation  Peak  1  Peak  and Track  These modes are  selectable with the MDE button        ANT  A LS    AutoClr    4Pk             Peak    Peak displays and retains the maximum torque experienced by the transducer  Peak  mode is used for dial torque wrench testing  preset torque tools  and power tool  verification testing     ist Peak  When the MDE key is pressed  the operating mode switches to 1  Peak     1    Peak detects the    first peak    of torque experienced by the transducer  1  Peak mode is  used for click wrench calibration and testing  capturing the initial peak torque by  monitoring the torque signal drop as it occurs when a click wrench actuates  1  Peak can  reduce operator influences to provide the user with more accurate torque wrench  performance data     Track  When the MDE key is pressed again  the operating mode switches to Track     Track displays torque as it is being applied to the transducer  Track mode is used  primarily for verifying calibration of the unit and can also be used when testing and  calibrating dial torque wrenches or in conjunction with a torque loading mechanism     Notice that    AutoClr    disappears when Track is enabled   Pressing the MDE key again cycles back to Peak mode     Now that the mode has switched back to Peak     AutoClr    reappears        November 2006       Setting Engineering Units                
3.  decreasing  order     When finished  press the CLR ent key to accept the value and return to operational  mode  or press the PGM key to accept the value and continue to the next Program  Function     Sleep Mode    To conserve battery life  these testers are equipped with a    sleep    mode  which sets the  unit to standby after a user selectable of time has passed without activity  To access the  sleep mode  press the PGM key four times  This example shows sleep turned off     Press the Up Arrow key to increase the number of minutes the unit will wait for input  or  press the Down Arrow key to decrease the number  This example shows a value of four  minutes     The highest possible sleep setting is 20 minutes  Press CLR ent to accept the value and  return to operational mode  or press the PGM key to accept the value and continue to the  next function        November 2006       Programming cor        Lock Out Mode  pce For security reasons  it may be desirable to limit the modes and functions available to the    personnel using this equipment  The Lock Out Mode enables the user to specify the      h modes and functions unavailable to others and ensure security by removing the Program  LL  Key located on the back side of the unit        Use the Up Arrow or Down Arrow keys to cycle through all the possible lockout  choices  This example indicates that after the program key is removed  the operator will  not be able to change the unit   s operation mode        na    wi This exam
4.  lt P    AIMCO    UET Series Torque Analyzer  Operations Manual       PO Box 16460  Portland  OR 97292 0460 e 800 852 1368 e Fax 800 582 9015       Quick Start Guide       When unpacking the UET Series tester  ensure that you have all six components     P    10     1  UET Series Instrument  as pictured   Rundown Fixture  joint simulator   Power bit to engage bolt in Rundown fixture    Security Key  gt     AC Power  amp  Battery Charger    DARAN    Operations Manual       lease read manual prior to usin       Insert key into center I O  as pictured     If using a power tool  insert rundown fixture into female square of transducer  1f using a manual  torque tool  insert bit adapter directly into transducer female square    Push the    On    button  the white circle with a white dot     The unit will default and only be active in the first direction used  CW or CCW   to use in the other  direction  simply press the    On    button to re zero the instrument and re initialize zero    Using the    PGM    button  select L O  to    OFF     press enter after selection     Using the    PGM    button  select Filt  for Pulse tools  amp  Click wrenches  at least 1000  for all other  tools  500 is sufficient  press enter after selection     Using the    MDE    button  select torque mode  Pk  1  Pk or Track    Pk is for Power tools  Dial  wrenches  and Preset torque limiting tools  1  Pk is for Click type tools   Using the    ENG    button  select the desired engineering unit  IN LB  IN OZ 
5. The AIMCO UET Series Testers support eight engineering units  FT LB  IN LB  IN OZ   Kgf m  KgfCm  gfCm  Nm  and cNm  These units are selectable on the fly through use  of the ENG button which will cycle through all eight units     A unit set for IN LBs     When the ENG button is pressed  units change to IN OZ     Changing the engineering units will clear the peak     Pressing ENG again switches the units to Kgf m  Continue pressing the ENG button  until the desired engineering unit is reached     The selection order is  Kgf m  KgfCm  gfCm  cNm  Nm  FT LB  IN LB  IN OZ   NOTE  When scrolling through the different engineering units  an Over Range    designator    _ _ _ _    may appear  signifying an out of range selection  For example  a  1 000 ft  lb  system would show over range if In Oz was selected        November 2006       Setting AutoClr             a          AutoClr works in the Peak and 1   Peak Modes  freeing the operator from manually  clearing the display after a reading  AutoClr can be set from one to nine seconds or  completely off     When AutoClr is disabled  the reading will be retained on the LCD display until the  operator presses the CLR key     Pressing the A C key displays the current AutoClr setting     Pressing the A C key again will change    OFF    to a value of    1     referring to the number  of seconds the system will hold a reading on the LCD display before clearing     Repeatedly press the A C key to scroll from    OFF    to    9     When the de
6. circle is    OFF    while the button labeled with the circle with a dot in the center is the    ON    and    ZERO    button   Occasionally  the user may wish to re establish the zero reference between the transducer and the tester   particularly when taking measurements in both directions   To zero the unit during operation  press the     ON ZERO    button     Unit 10 Connections       The IO ports are on the back of the unit  The AIMCO UET has three interface ports   All of these ports are labeled on the back of the unit     DC In    The interface for the AC Adapter is supplied with the unit  Use  this to operate unit with AC power and recharge the batteries     Keylock    The    key    is a small  black plastic connector that is inserted into  the small receptacle in the center position  When this key is  removed  the functions and modes specified for lockout will be  disabled  See Page 8 for additional details on    lockouts           RS 232    If you are communicating to a printer  data collector  computer  etc   this is the mini plug connector for the  RS 232 cable  Serial data is sent every time the unit clears automatically or the CLR button is pressed  See  page 3 for details        November 2006  2        Components con        Other Components  Batteries    The AIMCO UET testers employ a dedicated charging circuit  With the AC adapter plugged in  the battery will  fully charge in approximately 3 hours  the system can be used while charging  Fully charged batteries sh
7. e button operation    e Dedicated  integrated transducer in horizontal or vertical configurations    Clockwise and Counterclockwise Operation    The AIMCO Universal Electronic Tester is capable of operating in both the clockwise and counterclockwise  directions  Please Note  If a unit is not calibrated in the counterclockwise direction  it will not function in the  counterclockwise direction and the    OVERLOAD    flag will appear     Please Note  When working in Peak or First Peak modes  the default direction  CW CCW  is set by the first  torque measurement  To change direction  the unit must be zeroed  press the On Zero key  before taking a  measurement in the opposite direction     To ensure accuracy  you should always remove hysteresis when changing the direction of torquing   By loading  the transducer to 90  FSD in the direction of intended use several times  3 to 5          November 2006  l        Components          The five program buttons on the keypad of the AIMCO Universal Electronic Tester perform multiple functions   The dominant function   labeled in bolder  larger letters on the buttons are used during normal unit operation   They are  PGM  MDE  ENG  A C  and CLR     The secondary functions   labeled in thinner  smaller letters on the buttons are used for programming the unit   They are  down arrow  up arrow  step  and ent     Off  amp  On Zero    The two oval buttons on the face of the tester are the power and zero buttons  The button labeled with the empty  
8. ould  provide approximately 16 hours of continuous use     Rundown Fixtures    Each unit is shipped complete with a rundown fixture  joint simulator   The above  illustration demonstrates the Rundown Fixture  The washer stack is comprised of  belleville washers  designed to compress as the bolt tightens  By varying the arrange   ment of these washers  various joint rates can be simulated  To test power tools  it is  necessary to use joint simulators  The joint simulator has a male square drive which is  inserted into the female square of the transducer  This Rundown Fixture can be  configured from a hard to a soft joint  The standard configuration is a medium joint up to 1 000 in Ib        RS 232  Ground      Transmit Ce        sf 9   Every time the unit clears a reading  whether through the AutoClr function or when the CLR button is pressed   the value is transmitted through the RS 232 port  This value is transmitted as serial data and can be read by a  printer  computer  or data collector  RS 232 cable sets are not included with the system but may be ordered  separately as an accessory     RS232 Transfer Protocol RS32 Datastream Format  Protocol Value sdddddbuuuuucl  where   Cable 9 pin to mini plug s Sign  space or    c Carriage Return  Baud 9600 d Data with Decimal Point   Line Feed  Parity None u Units  Bits 8  S Bit 1    Handshake Xon  Xoff    RS232 Cable Pinouts  Pin   Description Pin   Description  1 Unused 6 Unused  2 Transmit 7 Unused  3 Receive 8 Unused  4 Unused 9
9. ple indicates that after the program key is removed  the operator will not be    able to change the status of AutoClr        AutoCir        This example indicates that after the program key is removed  the operator will not be  able to change the unit   s operation mode or change the status of AutoClr     AutoCir       oa This example indicates that after the program key is removed  the operator will not be  Ir able to change the unit   s operation mode or engineering units   LLL   The possible lockout options are  Mode  AutoClr  Mode  amp  AutoClr  Engineering       Units  Mode  amp  Engineering Units  AutoClr  amp  Engineering Units  Mode  AutoClr    amp  Engineering Units  and None  OFF         Calibration       We strongly urge against customer use of the calibration function  This is used by AIMCO or AIMCO approved  Service Centers for the calibration of transducers to displays        November 2006  8     1204 E Maple Road  Troy  MI 48083  248 583 1180  248 583 7115  Fax        AIMCO    Corporate Headquarters    10000 SE Pine Street  Portland  OR 97216  800 852 1368  800 582 9015  Fax   www aimco global com    Ave  Morones Prieto 2110 Pte    Col  Loma Larga  Monterrey  NL CP 64710  Mexico   011 52 81 1001 1600  011 52 81 1001 1630  Fax     LIT MAN252     2006 AIMCO    
10. sired value is  shown  press the CLR ent button     Once CLR ent is pressed  the unit will return to operational mode with AutoClr now  showing on the bottom right of the display  Because AutoClr is now active  this reading  will remain on the LCD display for the user specified number of seconds          and then clear the LCD display  From now on  every reading will clear automatically  after the specified number of seconds     Remember that AutoClr will not work in Track Mode           Programming       Fut  con  h h             Fut  cone    a LILI             hea  Lim  C   a  Lt       The Program Key  PGM  is located on the front panel  Pressing the Program Key  repeatedly will cycle through the following Program Functions  please see the associated  sections for details about each function   To deactivate the program button and lockout  selected features  remove the tamper key on the left side of the unit     Set Filter    The filter is used to set the Hz speed at which the unit will capture peak  Press the PGM  key one time to access the Set Filter Function  This example shows a unit set at 500 Hz     Pressing the Up Arrow key will increase the value by 500 to 1000 Hz     Pressing the Up Arrow key again will increase the value by 500 to 1500 Hz     Pressing the Up Arrow key again will increase the value by 500 to 2000 Hz     Press the Up Arrow key again and the value will cycle back to 500 Hz     You can also use the down arrow key to cycle through the Hz settings but in
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Pioneer F9210 Installation Guide  cahier osmose 2008.cdr - Les Équipements Lapierre  CL08 カタログ  本器を末永く ご鶏いただくために~~ ご使用の前に二融取扱説明をよくお  Henry Schein Practice Solutions  Epson Stylus Pro 10000 Print Engine with Photographic Dye Ink Product Support Bulletin  ASUS M51AD J9019 User's Manual    Copyright © All rights reserved. 