Contents
1. UHW tank pump CH gas boiler CH pump Radiator heat load EUROSTER 11E USER MANUAL 7 Utility hot water re circulation pump control mode the so called third pipe EUROSTER 11E 1 Controller EUROSTER 11E Re circulated water temperature ude A So N 3 Re circulation pump 4 CH boiler with UHW tank J 5 CH pump 6 Radiator heat load ar 16 ELECTRONIC WASTE MANAGEMENT INFORMATION We made every effort to get as a long controller lifetime as possible However the device is subject to natural tear and wear We ask you to have a controller that will not meet your requirements any more brought in to an electronic waste management facility Electronic waste is collected free of charge by local distributors of electronic equipment Inappropriate management of electronic waste may lead to an unnecessary environment pollution Cardboard boxes should be disposed of at a paper recycling facility EUROSTER 11E CONTROLLER WARRANTY CERTIFICATE Warranty terms 1 Warranty is valid for 24 months from the controller sale date 2 Warranty is valid exclusively on the territory of Poland 3 Claimed controller together with this warranty certificate must be supplied to the seller or directly mailed via Poczta Polska mail operator to the manufacturer 4 Warranty claims shall be processed within 14 business days from the date the manufacturer has received the claimed device 5 Controller may be repaired exclusiv
2. see section 8 below 7 MODE OF OPERATION AND FACTORY DEFAULT PRESETS The EUROSTER E11E controller may be operated in two modes it may control CH system pump or UHW system pump In the former mode the CH system pump is engaged if sensor temperature has exceeded the preset limit In the latter mode the UHW system pump is kept running until sensor temperature reaches the preset value Restore one of the factory default presets to change the mode e Set 1 has been complied for layouts in which CH system pump is controlled Set 2 has been complied for layouts in which UHW pump is controlled Proceed as follows to restore factory presets e g in order to change the controller operational mode Press the knob and while holding it depressed turn the controller off and on Fd factory defaults is displayed Release the knob Digit O is displayed Select the desired set of defaults 1 or 2 and accept the selection Check and correct the presets if needed 8 CONTROLLER PRESETS Shortly after power supply of the controller is turned on current state of the system is shown on the display Turn the knob to the right to enter the preset browse edit mode General procedure to edit a preset 1 Turn the knob to select the desired preset parameter The controller displays current value of the selected parameter top and its number bottom Press the knob The displayed parameter value starts to blink Set the desi
3. shorted Sh or opened OP Check replace the sensor cable or ship the controller together with the sensor to service c Pump does not operate Turn on the controller and make sure that pump icon is displayed If not check the presets or restore factory ones see section B d Nie znaleziono r d a odwo ania Check pump connection d Controller knob operates erratically Pulse generator failure Have the controller serviced 12 COMPATIBILITY WITH STANDARDS CERTIFICATES The EUROSTER 11E controller meets all requirements of the EMC and the LVD EU Directives The CE Conformity Declaration is available on the http www euroster com pl Internet webpage 13 SPECIFICATIONS a Mains 230 V 50Hz b Current consumption max 7 mA 1 6 W c Output rated load 3A d Length of cables 15m e Dimensions width x height x depth 150 x 90 x 54 mm 14 KIT CONTENTS a controller box with temperature sensor b sensor hose clip c box fasteners anchors d this Installation amp Operation Manual e template to drill holes for fasteners anchors EUROSTER 11E USER MANUAL 15 CONNECTION DIAGRAMS Diagrams presented below are simplified not every element necessary to correctly operate the system is shown Central heating pump control mode te a dae ca al EUROSTER 11E controller CH boiler Heat source temperature sensor CH pump Radiator heat load EUROSTER 11E controller UHW tank temperature sensor UHW tank
4. EE test the controller the controller OFF OFF ON ON 9 CONTROLLER OPERATION Central heating pump control mode e The pump is engaged as soon as the boiler temperature Tboier has exceeded the preset threshold Tprest by more than half of the pump hysteresis Hpump T boiler gt T preset Hpump 2 e The pump is disengaged as soon as the boiler temperature has dropped below the threshold by more than half of the hysteresis T boiler lt T preset m Hpump 2 Utility hot water pump control mode e The pump is engaged as soon as the UHW tank temperature Tian has dropped below the threshold Tpresee by more than half of the pump hysteresis Hpump Trank lt T preset A pump 2 e The pump is disengaged as soon as the UHW tank temperature has exceeded the threshold by more than half of the hysteresis Trank gt T preset Hpump 2 10 THE ANTY STOP FUNCTION The ANTY STOP function turns on the pump immediately after the controller is turned on then every 14 days AS letters are blinking on the controller display while the function is active Any alarm generated while the ANTY STOP function is active overheating or temperature sensor failure aborts the function execution EUROSTER 11E USER MANUAL 11 TROUBLESHOOTING a Device is dead Burnt mains fuse or ROM failure Replace the fuse or have the controller serviced b Sensor icon on the display blinks Sh or OP letters next to the icon Sensor circuit
5. EUROSTER 11E USER MANUAL EUROSTER 11E CENTRAL HEATING UTILITY HOT WATER SYSTEM PUMP CONTROLLER CEO MANUFACTURER P H P U AS Polanka 8a 3 61 131 Poznan POLAND 1 INTRODUCTION Carefully study this user manual to learn how to correctly operate the EUROSTER 11E central heating utility hot water system pump controller 2 FIELD OF APPLICATION EUROSTER 11E is a modern microprocessor based controller used to control central heating CH system pump or utility hot water UHW system pump The EUROSTER 11E controller features the ANTY STOP EUROSTER 411E function that prevents idle pump rotors against seizing Once r the heating season is over every 14 days the function automatically turns ON the pumps for 30 seconds To that end the controller must be left powered up 3 VISIBLE CONTROLLER ELEMENTS 1 230 VAC mains input 2 230 VAC power supply to pump 3 Input for temperature sensor cable 4 Mains switch 5 LCD display 6 Knob 4 INSTALLATION Hazardous voltages may be present inside the controller and on its cables Therefore it is expressly forbidden to install the device prior to disconnecting its mains power supply Only qualified technicians may install the controller Do not install any devices showing signs of any mechanical damage The procedure a Mount the controller using a pair of supplied nylon nail it fasteners anchors mount the controller box on a EUROSTER 11E USER MANUAL wall or an
6. ely by the manufacturer or by other party clearly authorized by the manufacturer 6 Warranty becomes invalidated in case of any mechanical damage incorrect operation and or making any repairs by unauthorized persons 7 This consumer warranty does not exclude restrict nor suspend any right of the Buyer ensuing if the product would not meet any of the sale contract terms sale date serial number date of manufacture signature stamp Service phone 48 655 71 20 12 Business entity that issued this warranty certificate P H P U AS Agnieszka Szyma ska Kaczy ska Chumi tki 4 63 840 Krobia Poland
7. ly controlled Alarm icon blinks in case of an alarm State of the heat source boiler furnace animated icon see description below UHW system pump icon lit while the pump is running UHW system control mode CH system pump icon lit while the pump is running CH system control mode Heat source boiler UHW tank temperature CH system UHW system control mode respectively other displayed parameter value 9 UHW tank temperature sensor icon UHW system control mode 10 Menu option number displayed while set point values are browsed set ee a Animated icon that visually presents state of the heat source boiler furnace is for information purposes only it does not influence operation of the controller in any EUROSTER 11E USER MANUAL 3 way Normal operation A lt gt M Supply temperature between 35 C and 90 C gt M Supply temperature gt 90 C Overheating lt Furnace put out Supply temperature lt 35 C 6 TURNING THE CONTROLLER ON e Turn the controller mains switch 4 in section 3 into the I position gt Device firmware version No and compilation date are sequentially displayed for 2 s gt AS letters are blinking on the display while the ANTY STOP function turns on the pump gt State of the system is shown on the display e If the controller is being turned on for the first time select the desired mode of operation see section 7 below and set the desired controller presets
8. red new value and press the knob to accept it or Wait 10 seconds until the displayed parameter value stops blinking in order to abort the edit procedure to leave the current value intact Configuration windows are numbered to facilitate manipulations User may edit the following EUROSTER 11E USER MANUAL 4 controller parameters presets 1 Controlled temperature Threshold temperature at which controller will turn the respective pump ON OFF 2 Pump hysteresis Difference between the temperature at which the controller turns the pump ON and the temperature at which the controller turns it OFF See section 9 below for details 3 Temperature sensor correction A constant added to subtracted from all values measured by external temperature sensor to compensate for difference in respect to water temperature inside the system 4 Pump manual operation test Display current pump status commanded by the controller 0 1 pump disengaged engaged Press the knob and modify the parameter value to manually control the pump Press the knob once more or leave it inactive for 10 seconds to resume automatic mode of control All presets are listed below for two possible modes of operation e CH central heating pump control mode e UHW utility hot water pump control mode Parameter Preset value Controlled temperature 4 Pump hysteresis Temperature sensor correction 4 Pump manual operation as calculated by as calculated by N
9. y other suitable supporting structure e using fasteners fix controller cables to the wall b Install temperature sensors e do not immerse sensors in liquids nor install them within stream of flue gases install boiler temperature sensor at the boiler point specially designed for that purpose or else on an unshielded boiler outlet pipe as close to the boiler as possible or install UHW tank temperature sensor at the tank point specially designed for that purpose using hose clips tighten the sensor to its pipe and cover it with thermal insulation c Hook up pump power supply cable connect yellow or yellow green PE wire with the connect blue wire with the N terminal connect brown wire with the L terminal terminal d Verify the connections check up all cable connections and tighten terminal box lids e Hook up the controller e make sure controller cables are protected against incidental cut off plug the controller power supply cable into a 230V 50Hz mains socket equipped with a grounding pin The controller must not be installed in a place where the ambient temperature may exceed 40 C 5 CONTROLLER DISPLAY Elements of the controller display HYSTERESIS TEMPERATURE CORRECTION Name of the controlled parameter displayed while set point values are browsed set Heat source boiler temperature sensor icon CH system control mode Manual operation mode icon lit while the temperature is manual
Download Pdf Manuals
Related Search
Related Contents
` していませんか? 自 素材・加工部門シーズ集 Deluxe High Wall Mini Split Service Manual ETCR010 Split Type High Accuracy Leakage Current Sensor User`s Philips PET723/05 User's Manual KIPOR POWER PRODUCTS CO., LTD. IG2000/IG2000P/IG2000S Kit de Virtualización de Escritorio X550 GAS COMPACT CLEANING SYSTEM INSTALLATION Copyright © All rights reserved.