1. Page 1 23 24 24 25 26 26 27 27 28 29 30 31 33 33 34 35 36 User Manual User Manual GARDTEC 800 Series User Information Control Panel Model SAM 81 84 i No of Keypads eypad 1 Location pe eypad 2 Location pe eypad 4 Location pe eypad 5 Location 840 pe eypad 6 Location 840 pe eypad 7 Location 840 pe eypad 8 Location 840 pe ACE Mode if fitted Normal Securit High Securit Keyswitch 1 Location Reserved User Code User No Keyswitch 2 Location Reserved User Code User No Keyswitch 3 Location Reserved User Code User No Keyswitch 4 Location Reserved User Code User No Keyswitch 5 Location Reserved User Code User No Keyswitch 6 Location Reserved User Code User No switch 7 Location Reserved User Code User No switch 8 Location Reserved User Code User No Note Please ensure this section is completed by the installation engineer Page 2 GARDTEC 800 Series User Manual Introduction The Gardtec 800 Series of control panels consists of 3 models the Gardtec 800 the Gardtec 876 and the Gardtec 840 Two types of display variation are also available LCD giving two rows of 16 character English text and LED giving two 7 segment LED digits Throughout this manual references will be made to the specific model of control panel and also the display type You may find this information from the user information section on page 2 of this manual Please take time to familiarise yourself with the ty
2. The system is now reset Page 20 GARDTEC 800 Series User Manual Using LED Keypads This section is dedicated to using LED keypads Twin Seven Segment Setting The System 800 816 840 With the display showing Un 2 Enter the User Code followed by YES if Master or Main type code has been used 3 The display will show E and the exit tone will sound Exit the premises via the authorised exit route the exit tone will change if any detectors are violated during exit 4 Once the premises are secure listen that the exit tone returns to the continuous tone 5 Wait until the exit tone finishes before leaving Note Setting the system with an area code will set only the area associated with that code Note Setting an unset system with a cleaner code will set the full system Unsetting The System 800 816 840 1 Enter the premises via the authorised entry route the broken entry tone will sound 2 Proceed to the keypad enter a valid user code the display will show Un 3 The system is now Unset Note If an area code has been entered only the area associated with that code will be Unset Note If a cleaner code has been entered only the cleaner area will be Unset Page 21 User Manual GARDTEC 800 Series Part Setting The System using Master amp Main type codes 800 816 840 1 With the display showing Un Enter a Master or Main type code 2 The display will show SE flashing Press
3. GARDTEC 800 Series 4 The exit tone may or may not be heard dependant on the system settings Exit the premises or retire to an unprotected part of the system At the end of the exit time either the exit sounder will stop or a single beep will be emitted dependant on system settings Part Setting System using Area 1 2 or 3 codes 1 With the display showing Enter an Area Code 1 2 or 3 the exit tone will sound and the display will show for example Press NO then 1 2 or 3 for the Part Set you require the display will show for example The exit sounders may or may not go silent this will depend on the system settings Exit the premises or retire to an unprotected part of the system At the end of the exit time either the exit sounder will stop or a single beep will be emitted dependant on system settings Page 7 User Manual 840 lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 EXIT Now 1 All Zones ON 15 EXIT Now 1 Part 1 20 User Manual GARDTEC 800 Series Area Setting using Master or global Main codes 840 Areas will need to have been set up by the installation company 1 Note With the display showing cce cUNSET gt gt gt gt 01 JAN 18 58 01 Enter a Master or global Main code the display will show for example Do you wantto Set ELIZABETH Pres
4. To set the system with a biased keyswitch insert the key and turn it then return the key to the original position and remove To unset repeat this operation Page 5 User Manual GARDTEC 800 Series Unsetting The System 800 816 840 1 Note Note Enter the premises via the authorised entry route the broken entry tone will sound proceed to the keypad At the keypad enter a valid code the display will show lt lt lt lt UN SET gt gt gt gt Area information may be shown on 840 01 JAN 18 58 01 The system is now unset If an Area Code 840 Only has been entered only the area associated with that code will be unset If a Cleaner Code has been entered only the cleaner area will be unset Part Setting The System using Master amp Main type codes 800 816 840 1 Note Note With the display showing ene gt Enter a Master or Main type code the display will show for example Do you want to User Name on 816 amp 840 Only Set STUART Press 1 2 or 3 for Part 1 2 or 3 the display will show for example 1 2 3 may not show on Gardtec 800 amp 816 EXIT Now 123C Part 1 15 840 Only If a Global code Master or Main has been used all areas that are being set will be Part 1 set 840 Only If an Area Main code has been used only Part 1 set for that associated area will occur Page 6
5. entering characters up to 9 If you require a blank space press YES while the is displayed 13 As you press YES for the ninth character or if you have jumped from step 9 the display will change to Do you want to Prog USER CODES 14 If you wish to program other User Codes return to step 4 Or Press 0 to return to lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 Page 16 GARDTEC 800 Series User Manual Programming Time amp Date 800 816 840 1 With the display showing lt lt lt lt UNSET gt gt gt gt 01 JAN 18 58 01 2 Enter a Master Code the display will show Do you want to User Names on 816 amp 840 Only Set STUART 3 Press NO six times the display will show Do you want to Set DATE TIME 4 Press YES the display will show Enter Day Month Then YES 5 Enter the Day Month ie 0706 for 7th June followed by YES The display will show Enter Hrs Mins 1 Then YES 6 Enter the time using 24Hr Clock ie 23 30 for 11 30pm followed by YES the display will show Do you want to Set DATE TIME 7 Press 0 the display will show 2222UN SETS S55 07 Jun 23 30 02 Page 17 User Manual GARDTEC 800 Series User Initiating Remote Access Optional 800 8
6. using Duress on the Gardtec Series see Using Duress Section Page 3 User Manual GARDTEC 800 Series User Code Types 840 Ten types of User Codes are available on the Gardtec 840 and each type allows for different levels of access In total 47 User codes may be programmed by a Master Level User Code to any of the ten types User number 1 will always be a Master Level User but the remaining 46 User Codes may be programmed to the required level of access The Code Levels should be viewed as two groups global codes that give system control and area codes that give area control The User Code levels available and the functions available for the levels are Global Code Levels 0 Set Only Only Allows for the setting of the system 1 Main Allows Setting Part Setting Area Setting Zone Remove System Test Unsetting 3 Master Allows Setting Part Setting Area Setting Zone Remove System Test Viewing the Log Chime On Off Program User Codes Set Time Date Unsetting Area Code Levels 2 Area 1 Allows Area 1 Setting Area 1 Part Setting Area 1 Unsetting 4 Cleaner Full System Setting from unset system Cleaner Area Unsetting from set system Cleaner Part Set from part cleaner set system 5 Area 2 Allows Area 2 Setting Area 2 Part Setting Area 2 Unsetting 6 Area 3 Allows Area 3 Setting Area 3 Part Setting Area 3 Unsetting 7 Main 1 Allows Area 1 Setting Area 1 Part Setting Area 1 Zo
7. 1 2 or 3 for Part 1 2 or 3 the display will show the E and The two bottom bars if Part 1 has been selected The top and bottom bars if Part 2 has been selected The bottom bar only if Part 3 has been selected Note If a Global code Master or Main has been used all areas that are being set would be Part Set Note If an Area Main code has been used only the Part Set associated with that area would be Part Set 3 The exit tone may or may not be heard dependant on the system settings 4 Exit the premises or retire to an unprotected part of the system At the end of the exit time either the exit tone will stop or a single beep will be emitted dependant on system settings Part Setting System using Area 1 2 or 3 codes 840 1 With the display showing Un Enter an Area code 1 2 or 3 2 The exit tone will sound and the display will show E 3 Press NO then 1 2 or 3 for Part 1 2 or 3 The bars on the display will change to The two bottom bars if Part 1 has been selected The top and bottom bars if Part 2 has been selected The bottom bar only if Part 3 has been selected 4 The exit tone may or may not be heard dependant on the system settings 5 Exit the premises or retire to an unprotected part of the system At the end of the exit time either the exit tone will stop or a single beep will be emitted dependant on system settings Page 22 GARDTEC 800 Series User Manual 840 Area Setting using Master or Global Main
8. 16 840 Access Remote allows your installation company to examine your system and re program system settings as you need the changes without the need for an engineer to visit your premises If your system has remote communications fitted your installation company may have programmed the system so that you initialise the Access Remote call usually on lines with incoming calls barred To initiate the Remote Call follow the instructions below 1 Negotiate with your installation company when you should initiate the Remote Call 2 With the display showing lt c lt lt UNSET gt gt gt gt 01 JAN 18 58 01 3 Enter a Master Code the display will show Do you want to User Names on 816 amp 840 Only Set STUART 4 Press NO seven times the display will show Do you want to Access Remote 5 Press YES the display will show Please WAIT Until Dialling commences Then Please WAIT Dialling Until Connection Then Please WAIT Connect 6 When your installation company has finished the display will show lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 Note In the event of any errors the display will show I ERROR Try Again Page 18 GARDTEC 800 Series User Manual Resetting After an Alarm 800 816 840 Your installation company will have progra
9. GARDINER TECHNOLOGY GARDIT ES 800 Series 800 816 840 LCD User Instructions amp LED User Instructions GARDTEC 800 Series Contents User Information eeeeeeeeeneeeeeneeeeneeeeee Using LCD Keypads e jigo o P oiiTo ENA RR ANA E RR DRE RR RO User Code Type ariista aa Setting The System a Unsetting The System Part Setting The System 00 eceeeseseeseeseneetseeeeeeetaee Area Setting rara REMOVING ZONES ccecccceseceeeeseeeeeeneeeeseeerseseeeeeseenenees Testing The System Viewing The Event Log Changing The Chime Status Programming User Codes Programming Time amp Date User Initiating Remote Access Resetting After An Alarm Using LED Keypads Setting The System Unsetting The System Part Setting The System Area Setting aerem sa saias agudo adia as ento sbre atada REMOVING ZoNe Sanninina anh es Testing The System ieii Viewing The Event Log Changing The Chime Status Programming User Codes User Initiating Remote Access Resetting After An Alarm LED Display Glossary ai System Attributes essere Service Record css mese assassinas E User GHAI ssiri ranura e e ES ao Sadia ACE INStructions asc casaca en aesvi niaaa Programming ACE Keyfobs onto your System
10. Only Set STUART 3 Press NO the display will show EFE REMOVE Zones 4 Press YES the display will show Enter Zone No then YES or NO 5 Enter the zone number you wish to remove followed by YES pressing NO will un remove a zone the display will show Enter Zone No then YES or NO 6 Repeat step 5 until you have removed all the required zones 7 Press 0 to escape the display will show Do you want to Set STUART 8 Press YES the continuous exit tone will sound 9 Exit the premises via the authorised exit route the exit tone will change as detectors are violated When the premises are secure listen that the exit tone returns to the continuous tone Wait until the exit tone finishes before leaving Note Zone remove is only effective for the one set Page 9 User Manual GARDTEC 800 Series Testing The System Master amp Main codes only 800 816 840 1 With the display showing lt lt lt lt UNSET gt gt gt gt 01 JAN 18 58 01 2 Enter a Master or Main level code 5 the display will show o you want to User Names on 816 amp 840 Only Set STUART 3 Press NO the display will show Do you want to REMOVE Zones 4 Press NO the display will show Bia vail want i TEST the System 5 Press YES the
11. R TECHNOLOGY Gardiner Technology Ltd Queensway Rochdale Lancashire OL11 1TQ United Kingdom Internet http www gardiner technology com e mail sales gardiner technology com Ce THE BRITISH SECURITY e NDUSTRY ASSOCIATION INVESTOR IN PEOPLE pa PR4345 Rev1 1
12. Tamper keypad 4 may show 1 to 4 Page 29 User Manual Displays Whilst Viewing Log 04 Alarm occurred because of zone 4 was activated o 04 Alarm occurred because of tamper on zone 4 04 flashing zone 4 was removed Lr Telephone Line restored Pr Power restored d3 Duress code by user 3 TE Watchdog reset Ar Alarm was reset bo bells on O1 User code 1 used may show 1 to 47 F2 Fire activated from alert keys on keypad 2 A2 Alert activated from alert keys on keypad 2 P2 Panic activated from alert keys on keypad 2 tF A zone on test has failed rL read Log Page 30 GARDTEC 800 Series GARDTEC 800 Series User Manual System Attributes one No one Type Descriptor 816 840 Areas 840 Part Info Example EE Fronbor 182 Ai Pi2 a E User Manual GARDTEC 800 Series Zone Type Descriptor 816 840 Areas 840 Part Info GARDTEC 800 Series User Manual Zone Type Descriptor 816 840 Part Info Service Record Date Comments Signature Alarm Reset Type Tamper Reset Type Page 33 GARDTEC 800 Series User Chart 800 816 840 Please use this chart to indicate what user names have been programmed onto your system and those that are in use User Manual Page 34 GARDTEC 800 Series User Manual ACE User Instructions 800 816 840 ACE Advanced Control Equipment allows control of your Gardtec 800 Series system via Infra Red Remote control Ace is availa
13. Whilst viewing the Log Pressing NO will move back to the previous event Pressing YES will move forwards to the next event Pressing 7 will take you back to the first event of the previous day Pressing 9 will take you forwards to the first event of the next day Pressing 3 will display the Date Time in the format Day of month two digits Month two digits Hour two digits Seconds two digits When you have finished viewing the Log press 0 twice to return to the Unset condition A complete list of possible LED displays is given in the section LED Display Glossary Page 25 User Manual GARDTEC 800 Series Changing The Chime Status Master code only 800 816 840 The Chime zones will have previously been programmed by your installation company A Master level code may change the status of the chime between On and Off To do so proceed as follows 1 With the display showing Un enter a Master code 2 The display will show SE flashing 3 Press NO four times the display will show Ch 4 Press YES the display will show oF or on 5 Press NO to change the Chime status 6 When you have finished press 0 twice to return to the Unset condition Programming User Codes Master code only 800 816 840 Please refer to pages 2 amp 34 for details of codes already programmed onto your system 1 With the display showing Un enter a Master code 2 The display will show SE 3 Press NO five
14. ble built in to a range of keypads or as a stand alone unit control is via neat remote keyfob s We strongly advise that User Number 1 is not used for ACE in order that the user retains control of the programming functions 8 1 Point the keyfob at the ACE receiver and press the button al Setting the System with ACE 2 When the exit tone sounds exit the premises in the usual way Part Setting the System with ACE 1 Point the keyfob at the ACE receiver and press the button 2 When you hear the exit tone press the keyfob button again within 3 seconds for Part Set 1 or Press 1 2 or 3 on the receiver keypad for the Part Set you require Unseitting the System with ACE 1 Enter the premises via an authorised entry point 2 Point the keyfob at the receiver and press the button Page 35 User Manual GARDTEC 800 Series Programming ACE 800 816 840 Keyfobs onto your System Two modes are available for ACE these are Normal amp High Security Please check the User Information Chart on page 2 noting the mode of your ACE control Normal Security In this mode up to fourteen keyfobs may be programmed onto a single user number 1 Follow the procedure for programming user codes to the point when the user code is entered 2 Point the keyfob at the ACE unit and press the button on the fob 3 Repeat this procedure for any other fobs you wish to be programmed using the same user number each ti
15. change the status of the Chime then press YES the display will show Do you want to Change Chime 6 Press 0 to escape the display will show lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 Page 13 User Manual GARDTEC 800 Series Programming User Codes Master code only 800 816 840 The charts on pages 2 amp 34 should be completed by the engineer user for future reference of what codes have been allocated on your system Under no circumstances should the actual user code be written down If your installation company has given you keyswitches for the operation of your system the last five user codes may have been reserved for use by these keyswitches If your engineer has indicated see pages 2 amp 34 that some of the user numbers on your system have been reserved you should not use them whilst programming user codes If you do so your system may be adversely affected 1 With the display showing lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 2 Enter a Master Code the display will show Do you Want to User Names on 816 amp 840 Only Set STUART 5 Do you want to 3 Press NO five times the display will show Prog USER CODES 4 Press YES the display will show Enter User No 1 7 displayed on 800 amp 816 1 47 Then YES 5 Enter the
16. codes 1 With the display showing Un Enter a Master or global Main code 2 The display will show SE flashing Press YES to start setting the system the exit tone will sound 3 To turn Area 1 Off press YES 1 and or To turn Area 2 Off press YES 2 and or To turn Area 3 Off press YES 3 and or To turn the Cleaner Area Off press YES 0 4 Exit the premises or retire to an unprotected part of the system At the end of the exit time the exit tone will stop provided the system was clear Note Areas must first be programmed by the installation company 840 Area Setting using Area codes Area codes are only effective to their own area with the exception of the cleaner area which may be turned off by an area code only if all areas are in the unset condition Removing Zones Master amp Main codes onl 800 816 840 If programmed by the installation company individual zones may be removed this may only be done by a Master or Main level of code It should be noted that if an Area Main code is being used 840 Only only zones associated with that area may be removed 1 With the display showing Un Enter a Master or Main level code 2 The display will show SE flashing press NO 3 The Display will show F E flashing press YES 4 The display will show F 5 Enter the zone number you wish to remove followed by YES Page 23 User Manual GARDTEC 800 Series The display will show r If you w
17. display will show Test ALL Areas This step not applicable on 800 amp 816 6 Press YES to test the full system or NO until the area you wish to test is shown 7 Press YES the display will show Status 4 Strobe for 3 seconds 6 Sounder 9 Bell Then for example lt All Zones OK gt TESTING 8 Pressing 1 will enter zone Status mode All zones will show on the display and will be deleted as each zone is triggered Press 0 to escape Pressing 6 will silence the internal sounder Pressing 4 will toggle the Strobe On Off Pressing 9 will toggle the Bell On Off Page 10 GARDTEC 800 Series 9 10 Whilst in Test mode any zones violated will sound the internal sounder if it has not been silenced and show on the display When you have finished testing the system press 0 twice the display will show Viewing The Event Log Master code only 1 With the display showing Enter a Master Code the display will show for example User Names on 816 amp 840 Only Press NO three times the display will show Press YES the display will show for 3 seconds Then for example Page 11 User Manual lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 800 816 840 lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 Do you wantto Set STUART Do you
18. ish to remove other zones return to step 5 Or To escape press 0 the display will show SE flashing Press YES to start setting the system Exit the premises or retire to an unprotected part of the system At the end of the exit time the exit tone will stop provided the system was clear Zone remove is only effective for the one set Testing The System Master amp Main codes only 800 816 840 With the display showing Un Enter a Master or Main level code the display will show SE flashing Press NO twice the display will show t E flashing Press YES the display will show t A press YES if you wish to test all areas or press NO until the area you wish to test is displayed then press YES The display will show t E if all zones are clear Whilst in test mode Pressing 6 will silence the internal sounders Pressing 4 will toggle the strobe On Off Pressing 9 will toggle the Bells On Off When you have finished testing the system press 0 twice to return to the Unset condition Page 24 GARDTEC 800 Series User Manual Viewing The Event Log Master code only 800 816 840 Note With the display showing Un enter a Master code The display will show SE flashing press NO three times The display will show L o flashing Press YES the display may show for example AL this is the most recent event If you have a printer connected pressing 1 will toggle the printer On Off
19. make a note of the four digit number given on the display call the installation company or central station for an Anti Code and proceed as shown from step 4 4 To reset the system with an Anti Code enter the number given by the central station or installation company into the keypad this may contain the YES amp NO keys 5 The system is now reset Page 28 GARDTEC 800 Series User Manual LED Display Glossary 800 816 840 Displays During Normal Use Er Reset is required by a higher level code or an error has Un System Unset occurred whilst programming E The system is full setting Ac Reset by Anti Code is required as The system is fully set SE flashing Do you want to Set E The system is part 1 setting TE Remove zones The system is part 1 set 4E Test system ES The system is part 2 setting Ch Change Chime I The system is part 2 set Uc Program User codes E The system is part 3 setting dt Program date time a The system is part 3 set Lo Log CS The system is cleaner setting vo Waiting for numeric input c The system is cleaner set W wait system in use AL An alarm has occurred press NO En Engineer code reset required to view En flashing Call Engineer Fb Fuse blown or battery volts low e Cb Control box tamper e bb bell box tamper e E1 Expander1 tamper may show 1 to 8 PL Telephone Line fault or coms fail Pe Power Cut et4
20. me e g User 1 or User 2 etc each time 4 If more than one ACE receiver is fitted fobs need to be programmed onto all ACE receivers yet again the same user number should be used Note When programming the fob onto more than one receiver on the same system the bution on the fob MUST be held down continuously between programming onio the first and subsequent ACE receivers High Security In this mode each keyfob will occupy a User number The number of keyfobs that may be used is limited by the maximum number of user codes available on the system up to a maximum of fourteen 1 Follow the procedure for programming user codes to the point when the user code is entered 2 Point the keyfob at the ACE unit and press the button on the fob 3 Repeat this procedure for any other fobs you wish to be programmed using a different user number each time e g User 1 or User 2 etc each time 4 If more than one ACE receiver is fitted fobs need to be programmed onto all ACE receivers retaining the same user number for each individual fob Note When programming the fob onto more than one receiver on the same system the bution on the fob MUST be held down continuously between programming onto the first and other ACE receivers Note In all cases when the ACE is used only Master amp Main user levels will allow part setting via the keyfob Other code levels will only allow part setting in conjunction with the keypad Page 36 GARDINE
21. mmed the reset modes for your system so that it complies to your insurance company and legislation requirements Your installation company will have informed you as to the type of reset that your system is set for Before attempting to reset your system ensure that the system is Un set 1 If the system is programmed for any code reset enter a user followed by YES if Master or Main code is used the exit tone will sound and the display will show for example 123 may not show on Gardtec 800 amp 816 EXIT Now 123C All Zones ON 15 2 Enter the code again to abort the setting 3 The system is now reset Or If a higher level of code is required one of the following displays will be shown Can t Set Use Use a Master code to reset the system Master Code Or Can t Set Use Call the installation company ENGNR Code Or Can t Set Use Call the installation company and quote Enel want Node the number given Or Can t Set Use Anti Code 1234 Page 19 User Manual GARDTEC 800 Series 4 To reset the system with an anti Code contact the central station or engineer as instructed by the installation company and quote the source given by the display The central station or engineer will give a return Anti Code this may contain the YES amp NO keys for example 5 YES 2 4 Enter this Anti Code into the keypad
22. ne Remove Area 1 Test Area 1 Unsetting 8 Main 2 Allows Area 2 Setting Area 2 Part Setting Area 2 Zone Remove Area 2 Test Area 2 Unsetting 9 Main 3 Allows Area 3 Setting Area 3 Part Setting Area 3 Zone Remove Area 3 Test Area 3 Unsetting Page 4 GARDTEC 800 Series User Manual Setting The System 800 816 840 1 With the display showing lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 2 Enter the User code followed by YES if Master or Main type code has been used The display will show EXIT Now 1236 and a continuous exit tone will sound All Zones ON 15 1 23 C may not show on Gardtec 800 amp 816 3 Exit the premises via the authorised exit route the exit tone will change if any detectors are violated during exit 4 Once the premises are secure listen that the exit tone returns to the continuous tone 5 Wait until the exit tone finishes before leaving Note Setting the system with an area code 840 Only will set only the area associated with that code Note Setting an unset system with a cleaner code will set the full system Setting amp Unsetting the System via a Keyswitch 800 816 840 One of two types of keyswitch es may have been fitted to your system Normal To set the system with a normal keyswitch insert the key and turn to the ON position then remove the key To unset insert the key and turn to the OFF position Biased
23. pe of equipment fitted to your premises as it will prove invaluable whilst using this manual User Code Types 800 816 Four types of User Codes are available on the Gardtec 800 and six types on the Gardtec 876 each user code type allows for different levels of access In total 7 User codes may be programmed by a Master Level User Code User number 1 will always be a Master Level User but the remaining 6 User Codes may be programmed by a Master Code to the required level of access These may be changed at any time via a Master level code The User Code levels available and the functions available for the levels are 1 Set Only Only Allows for the setting of the system 2 Main User Allows Setting Part Setting Zone Remove if programmed by engineer System Test Unsetting Reset after Alarm if programmed by engineer 3 User Allows Setting Part Setting Reset after Alarm if programmed by engineer Unsetting 4 Master Allows Setting Unsetting Zone Remove if programmed by User 1 always Master engineer Test System View Log Chime On Off User Codes Set Time Date Reset After Alarm if programmed by engineer Unsetting 5 Cleaner Full System Setting from unset system 816 Only Cleaner Area Unsetting from set system Cleaner Part Set from part cleaner set system 6 Duress Initiates a Duress call to Central Station whilst appearing 816 Only to operate the system as normal Note For information on
24. s YES to start setting the system the exit tone will sound and the display will show EXIT Now 123C All Zones ON 30 To turn Area 1 Off press YES 1 and or To turn Area 2 Off press YES 2 and or To turn Area 3 Off press YES 3 and or To turn the Cleaner Area Off press YES 0 As areas are turned off they will be removed from the display Exit the premises or retire to an un protected area as detectors are violated the continuous exit tone will change Areas must first be programmed by the installation company before they will appear on the display Area Setting using Area codes 840 Area codes are only effective to their own area with the exception of the cleaner area This may be turned off by an area code only if all areas are in the unset condition Use is the same as Setting the system shown on page 5 but only the relevant area will be set Page 8 GARDTEC 800 Series User Manual Removing Zones Master amp Main codes only 800 816 840 If programmed by the installation company individual zones may be removed this may only be done by a Master or Main level of code It should be noted that if an Area Main code is being used only zones associated with that area may be removed 1 With the display showing lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 2 Enter a Master or Main level code the display will show Do you want to User Names on 816 amp 840
25. ted to do so by the installation company 1 With the display showing Un enter a master level code then press NO seven times the display will flash Ar 2 Press YES the display will show W Wait then di Dialling then Cn Connected 3 When the installation company has finished the display will return to Un In the event of an error the display will show Er you should try again Page 27 User Manual GARDTEC 800 Series Resetting After An Alarm 800 816 840 Your installation company will have programmed the reset modes for your system so that it complies to your insurance company and legislation requirements Your installation company will have informed you as to the type of reset that your system is set for Before attempting to reset your system ensure that the system is Un set 1 If the system is programmed for any code reset enter a user followed by YES if Master or Main code is used the exit tone will sound and the display will show for example E 2 Enter the code again to abort the setting 3 The system is now reset Or If the display shows Er when you attempt to reset it refer to the programmed reset mode and take the appropriate action as follows Reset Type Action Master Code Use a Master code to set and abort setting Engineer Code Call the installation company Engineer Anti Code Call the installation company Anti Code When you try to set the system
26. times the display will show Uc flashing 4 Press YES the display will show U 5 Enter the User number you wish to program 1 to 47 for 840 or 1 to 7 for 800 amp 816 followed by YES 6 The display will show Co Enter the required code 4 5 or 6 digits followed by YES Entering 000000 will delete an existing code 7 The will show t enter the code type from the following list followed by YES Code Types may be seen at the beginning of this manual 8 The display will show Uc flashing Page 26 GARDTEC 800 Series User Manual 9 If you wish to program other User codes return to step 4 Or To return to the Unset condition press 0 800 81 6 840 Programming Date amp Time Note When using LED keypads the Date amp time will only be displayed when the 3 key is pressed whilst viewing the Log 1 With the display showing Un enter a Master code 2 The display will show SE 3 Press NO six times the display will show dt flashing 4 Press YES the display will show d enter the day and month followed by YES e g 0706 for 7th June 5 The display will show t enter the time using the 24Hr clock followed by YES e g 2330 for 11 30pm 6 The display will show dt flashing 7 If you wish to re program the time return to step 4 Or To return to the Unset condition press 0 User Initiating Remote Access Users should only initiate Remote Access when instruc
27. user number 1 to 47 for 840 or 1 to 7 for 800 816 that you wish to program followed by YES the Wow Enter Codes display willshow o Then YES Page 14 GARDTEC 800 Series User Manual 6 Enter the code you require codes may be 4 5 or 6 digits followed by YES Entering 000000 will delete an existing code Note If the code already exists or is a duress of another code an error will be shown choose another code and return to step 6 7 The display will show not if user 1 is being programmed Choose Type The display will scroll showing the code O XXXXXX 1 XXXXXX types available see user types or display 8 Enter the required type followed by YES the display will show for example 816 amp 840 Only User 1 Name STUART 9 If you wish to accept the name shown press YES and jump to step 13 Or If you wish to change the name shown press NO the display will show User 1 Name gt 10 You may now enter up to nine characters for the user name using the layout shown below for the allocation of characters STU VWX YZ 0 9 User Manual GARDTEC 800 Series 11 Referring to the character map enter the required character pressing the 3 key will display G pressing it again will show H and again will show I once the correct character is displayed press YES and the display will move on to the next position 12 Continue
28. wantto View the LOG While Viewing 1 Printer On Off Read Log 01 JAN 18 58 01 User Manual GARDTEC 800 Series 5 This is the most recent event in the log Whilst viewing the Log Pressing NO will move back to the previous event Pressing YES will move forward to the next event Pressing 7 will take you to back to the last event of the previous day Pressing 9 will take you forward to the first event of the next day 6 When you have finished viewing the Log press 0 twice the display will show lt lt lt lt UN SET gt gt gt gt 01 JAN 18 58 01 Changing The Chime Status Master code only 800 816 840 The Chime zones will have previously been programmed by the installation company A Master level code may change the status of the Chime between On and Off To do so proceed as follows 1 With the display showing lt lt lt lt UNSET gt gt gt gt 01 JAN 18 58 01 2 Enter a Master Code the display will show for example Do you want to User Names on 816 amp 840 Only Set STUART 3 Press NO four times the display will show Do you want to Change Chime Page 12 GARDTEC 800 Series User Manual 4 Press YES the display will show for example Chime is Off ok Or Chime is On ok 5 Press NO to