1. OVER LOAD icon This icon appears and an alarm sounds to indicate the battery supplied outlets are overloaded To clear the overload unplug If it appears that our Product failed to protect any equipment plugged into it we will also send you forms for making your claim for the some of your equipment from the battery supplied outlets until the icon turns off and the alarm stops connected equipment We will repair or replace the equipment that was damaged because of the failure of our Product or pay you the BATT CAPACITY meter This meter displays the approximate charge level of the UPS s internal battery in 25 increments During a blackout fair market value NOT REPLACEMENT COST of the equipment at of the time of the damage We will use Orion Blue Book or or severe brownout the UPS switches to battery power the BATTERY icon appears and the battery charge level decreases another a third party valuation guide or eBay craigslist or other source to establish that amount Our maximum liability is limited to LOAD CAPACITY meter This meter displays the approximate output load level of the UPS battery outlets in 25 increments 150 000 for the AVRG750LCD and 200 000 for the AVRG900LCD FAULT The following number appears if there is a problem with the UPS Press the POWER button to turn the UPS off Ba ag E22 Battery Mode or AC Utility Power Mode Overload fault Unplug at least one piece of equipment from battery outlets and turn the Who Pays For
2. Product What is the Period of Coverage patery Mode or AGUUNY Power Mode Overngad Faull ocpurg wign This warranty covers the Product for three years Connected equipment is covered for as long as you own the Product Constant tone connected equipment exceeds the rating of battery outlets of the unit Please unplug at least one piece of equipment from battery outlets Who Is Covered This warranty only covers the original purchaser Coverage ends if you sell or otherwise transfer the Product Battery Output Short Fault Please unplug at least one piece of equipment from How Do You Get Warranty Service Constant tone battery outlets and turn on the UPS again If the fault still exists please contact 1 Before contacting CyberPower identify Your Product model number the Purchase Date and each item of Connected Equipment CyberPower Systems for support 2 Email us at tech cpsww com or Call us at 877 297 6937 3 If your product requires warranty service you must provide a copy of your dated purchase receipt or invoice Constant tone Charger Fault Contact CyberPower Systems for support How Do You Open A Connected Equipment Claim omm 1 Call us at 877 297 6937 or write to us at Cyber Power Systems USA Inc 4241 12th Ave E STE 400 Shakopee MN 55379 or send us an e mail message at claims cpsww com for instructions within 10 days of the occurrence DEFINITIONS FOR ILLUMINATED LCD INDICATORS 2 When you contact CyberPower identify the Prod
3. Shipping UPS on again We pay when we send items to you you pay when you send items to us E21 Battery Output Short fault Unplug at least one piece of equipment from battery outlets and turn the UPS on again What Are Some Examples Of What This Warranty Does Not Cover E01 Charger Fault Contact CyberPower Systems for support 1 This Warranty does not cover any software that was damaged or needs to be replaced due to the failure of the Product or any data E24 Internal Fault Contact CyberPower Systems for support that is lost as a result of the failure or the restoration of data or records or the reinstallation of software TECHNICAL SPECIFICATIONS 2 This Warranty does not cover or apply to misuse modification operation or storage outside environmental limits of the Product or the equipment connected to it nor for damage while in transit or in storage nor if there has been improper operation or maintenance or use with items not designed or intended for use with the Product such as laser printers appliances aquariums medical or life What Other Limitations Apply Capacity LOO AN AONA SEON 1 This Warranty does not apply unless the Product and the equipment that was connected to it were connected to properly wired and lets includi li ith electrical f f th lectrical ithout th f Nominal input Voltage ea grounded outlets including compliance with electrical and safety codes of the most current electrical code without the use of any ada
4. UPS is Reda ensure the battery s maximum charge capacity it is recommended that you charge the battery plugged into an AC outlet the battery will automatically charge whether the UPS is turned on or turned off 2 With the UPS unit turned off and unplugged connect your computer monitor and any other peripherals requiring battery backup into the battery power supplied outlets Plug the other peripheral equipment eg printer scanner speakers etc into the full time surge protection outlets DO NOT plug a laser printer paper shredder copier space heater vacuum cleaner sump pump or other large electrical device into the Battery and Surge Protected Outlets The power demands of these devices will overload and possibly damage the unit 3 To protect a fax phone or modem line connect a telephone cable from the wall jack outlet to the IN jack of the UPS Connect a telephone cable from one of the UPS OUT jacks to the modem port on the computer The other UPS OUT jack can be used to protect a telephone or fax machine 4 Plug the UPS into a 2 pole 3 wire grounded receptacle wall outlet Make sure the wall branch outlet is protected by a fuse or circuit breaker and does not service equipment with large electrical demands e g air Q ETO 5 Press the power switch to turn the unit on The Power On indicator light will illuminate green and the unit will beep once conditioner refrigerator copier etc Th
5. CyberPower Reliability Quality Value AVRG750LCD AVRG900LCD User s Manual PRODUCT REGISTRATION Thank you for purchasing a CyberPower product Please take a few minutes to register your product at www cpsww com registration Registration certifies your product s warranty confirms your ownership in the event of a product loss or theft and entitles you to free technical support Register your product now to receive the benefits of CyberPower ownership IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important safety instructions Please read and follow all instructions carefully during installation and operation of the unit Read this manual thoroughly before attempting to unpack install or operate your UPS CAUTION To prevent the risk of fire or electric shock install in a temperature and humidity controlled indoor area free of conductive contaminants Please see specifications for acceptable temperature and humidity range CAUTION To reduce the risk of electric shock do not remove the cover except to service the battery Turn off and unplug the unit before servicing the batteries There are no user serviceable parts inside except for the battery CAUTION Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected CAUTION The UPS must be connected to an AC power outlet with fuse or circuit breaker protection Do not plug into an outlet that is not gr
6. Full time surge protection outlets stop providing power to equipment Circuit breaker button is projecting from the side of the unit Turn the UPS off and unplug at least one piece of equipment Wait 10 seconds reset the circuit breaker by pressing the button and then turn the UPS on Circuit breaker has been tripped due to an overload Battery not fully charged Recharge the battery by leaving the UPS plugged in The UPS does not perform expected runtime Contact CyberPower Systems about replacement batteries at tech cpsww com Battery is worn out The on off switch is designed to prevent damage from rapidly turning it off and on Turn the UPS off Wait 10 seconds and then turn the UPS on The unit is not connected to an AC outlet The unit must be connected to a 120V 60Hz outlet The UPa will OU TUN on Contact CyberPower Systems about replacement batteries at tech cpsww com The battery is worn out Mechanical problem Contact CyberPower Systems at tech cpsww com The frequency is outside of the operating range of 57 63Hz Turn the UPS off Make sure the frequency range is within 57 63Hz Or you can turn the UPS on in battery mode Connect the USB cable to the UPS unit and an open USB The USB cable is not connected peiton the backo ine computer PowerPanel Personal Edition is inactive all icons are gray The USB cable is connected to a bad USB port Check for a different USB port and plug
7. UTION Risk of Energy Hazard 12V maximum 9 Ampere hour battery Before replacing batteries remove conductive jewelry such as chains wrist watches and rings High energy through conductive materials could cause severe burns 3 CAUTION Do not dispose of batteries in a fire The batteries may explode 4 CAUTION Do not open or mutilate batteries Released material is harmful to the skin and eyes It may be toxic CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF USED BATTERIES ACCORDING TO LOCAL REGULATIONS TO REPLACE THE BATTERY Turn off and unplug all connected equipment Unplug it from the AC power source Turn the UPS upside down Remove the 1 retaining screw Slide the battery compartment cover completely off of the unit Remove the battery from the compartment Disconnect the battery wires from the battery o N D o e ee Dee Install the replacement battery by connecting the red wire and black wire to the positive and negative terminal of the battery o Put the battery back into the compartment 10 Slide back the battery compartment cover and tighten the retaining screw 11 Charge the unit for 8 hours to fully charge the battery REMINDER Batteries are considered HAZARDOUS WASTE and must be disposed of properly Most retailers that sell lead acid batteries collects used batteries for recycling as required by local regulations TROUBLESHOOTING Problem Possible Cause sowon
8. ave setup mode and go back to the status display a Utility High Voltage Range Adjust the value of high voltage range b Utility Low Voltage Range Adjust the value of low voltage range c LCD L1 LO ON OFF When LCD is set to L1 LCD will be always ON When LCD is set to LO LCD will dim if untouched for 1 minute In battery mode LCD is always on regardless if the setting is L1 or LO 6 LCD module display LCD display shows all the UPS information using icons and messages For more information please review the Definitions for Illuminated LCD Indicators section 7 USB Port The USB port allows connection and communication between the USB port on the computer and the UPS unit Communication Protection Ports Communication protection ports will protect any standard modem fax or telephone line RJ11 9 Circuit Breaker Located on the side of the UPS the circuit breaker provides overload and fault protection 10 Ground Screw The ground screw is used for any equipment that needs a chassis ground connection 11 Outlets Designed for AC Adapters The UPS unit has four widely spaced outlets AC power adapters can be plugged into the UPS without overlapping or blocking adjacent outlets REPLACING THE BATTERY Replacement of batteries located in an OPERATOR ACCESS AREA 1 When replacing batteries replace with the same number of the following battery CyberPower RB1270B for AVRG750LCD CyberPower RB1290A for AVRG900LCD 2 CA
9. e warranty prohibits the use of extension cords outlet strips and surge strips in conjunction with the UPS unit 6 If an overload is detected an audible alarm will sound and the unit will emit one long beep To correct this turn the UPS off and unplug at least one piece of equipment from the battery power supplied outlets Make sure the circuit breaker is depressed and then turn the UPS on 7 To maintain optimal battery charge leave the UPS plugged into an AC outlet at all times 8 To store the UPS for an extended period of time cover it and store with the battery fully charged While in storage recharge the battery every three months to ensure optimal battery life 9 Ensure the wall outlet and UPS are located near the equipment being attached for proper accessibility BASIC OPERATION DESCRIPTION 1 Battery and Surge Protected Outlets The unit has six battery powered and surge protected outlets to ensure temporary uninterrupted operation of your equipment during a power failure DO NOT plug a laser printer paper shredder copier space heater vacuum cleaner sump pump or other large electrical device into the Battery and Surge Protected Outlets The power demands of these devices will overload and possibly damage the unit 2 Full Time Surge Protection Outlets The unit has six surge suppression outlets 3 Power Switch Used as the master on off switch for equipment connected to the battery power suppli
10. ed outlets To turn the UPS ON press the power button for approximately 2 seconds you will hear a constant tone 1 second and release after a short beep To turn the UPS OFF press the power button for approximately 2 seconds you will hear a constant tone 1 second and release after two short beeps Alarm setting The audible alarm can be turned Off or On by quickly pressing the POWER button twice The default setting is for the Alarm On To turn the Alarm Off quickly press the power button twice You will hear two short beeps when the Alarm is turned Off To turn the Alarm back On quickly press the power button twice You will hear a single short beep when the Alarm is turned On When the Alarm is turned Off there will be no audible notification when the UPS reaches a low battery state 4 Power On Indicator This LED is illuminated when the utility power is normal and the UPS outlets are providing power free of surges and spikes 5 Mode Switch Press the Mode Switch for approximately 3 seconds to enter setup mode to select three functions Utility High Voltage Range Utility Low Voltage Range and LCD sleep ON OFF When a function is selected press Mode Switch for 3 seconds to view options When an option is selected wait for 8 seconds for the setting to be confirmed After the setting has been confirmed the LCD screen will leave setup mode and go back to status display If there is no action for 8 seconds during setup the LCD will also le
11. ounded lf you need to de energize this equipment turn off and unplug the unit CAUTION To avoid electric shock turn off the unit and unplug it from the AC power source before installing a computer component CAUTION Not for use in a computer room as defined in the Standard for the Protection of Electronic Computer Data Processing Equipment ANSI NFPA 75 CAUTION To reduce the risk of fire connect only to a circuit provided with 20 amperes maximum branch circuit over current protection in accordance with the National Electric Code ANSI NFPA 70 DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT CyberPower Systems does not sell products for life support or medical applications DO NOT use in any circumstance that would affect operation and safety of life support equipment any medical applications or patient care DO NOT USE WITH OR NEAR AQUARIUMS To reduce the risk of fire or electric shock do not use with or near an aquarium Condensation from the aquarium can cause the unit to short out DO NOT USE THE UPS ON ANY TRANSPORTATION To reduce the risk of fire or electric shock do not use the unit on any transportation such as airplanes or ships The effect of shock or vibration caused during transit and the damp environment can cause the unit to short out INSTALLING YOUR UPS SYSTEM INTRODUCTION Thank you for selecting a CyberPower Systems UPS product This UPS is designed to provide unsurpassed power protection operation and performance d
12. pters or other connectors Input Frequency 60 Hz 3 Hz 2 The Product must have been plugged directly into the power source and the equipment connected to the Product must be directly connected to the Product and not daisy chained together in serial fashion with any extension cords another Product or device Or BaMeTy UPURI One TEOVACT D similar to the Product surge suppressor or power tap Any such installation voids the Limited Warranty Automatic Voltage Regulator AVR 3 The Product and equipment connected to it must have been used properly in a suitable and proper environment and in conformance with any license instruction manual or warnings provided with the Product and the equipment connected to it On Battery Output Frequenc 60Hz 1 ae ein ee ee i 4 The Product must have been used at all times within the limitations on the Product s VA Watt capacity Max Load for UPS Outlets 750VA 450W 900VA 480W 5 The sole and exclusive remedies of the Initial Customer are those provided by this Warranty oe A 5 Max Eoad for Pull Time Suge Protection outlets T What Limitations Apply if Mere 3 monnecied Equipment Guaranies CEG Coverage for My Product The Product was designed to eliminate disrupting and damaging effects of momentary less than 1ms voltage spikes or impulses On Battery Output Wave Form Simulated Sine Wave Form from lightning or other power transients If it can be shown that a voltage spike lasting longer than 1ms has occ
13. quariums ANY z SUCH USE IS IMPROPER AND IS A MISUSE OF THE PRODUCT Where Can I Get More Information The application of the United Nations Convention of Contracts for the International Sale of Goods is expressly excluded CYB ERPOWER G REEN POWER UPS T M TECH NOLOGY CyberPower is the warrantor under this Limited Warranty For further information please feel free to contact CyberPower at CyberPower Systems USA Inc 4241 12th Ave E STE 400 Shakopee MN 55379 call us at 877 297 6937 or send us an e mail message at claims cpsww com Advanced Energy Saving Patented Bypass Technology CyberPower s patented GreenPower UPS with Bypass Technology reduces UPS energy costs by up to 75 compared to conventional UPS models Even when utility power is normal conventional UPS models constantly pass power through a transformer By contrast under normal conditions the advanced circuitry CyberPower Systems encourages environmentally sound methods for disposal and recycling of its UPS products of a GreenPower UPS bypasses the transformer As a result the power efficiency is significantly Please dispose and or recycle your UPS and batteries in accordance to the local regulations of your state increased while decreasing waste heat using less energy and reducing energy costs When an abnormal power condition occurs the GreenPower UPS automatically runs power through its ENEROV SAVING ASTONS TESETVEG REPFOAUCNON WIHNOUE permis
14. roviding to the computer during normal AC Utility Power mode and battery backup mode descriptions apply when the UPS is you MUSI pay Mie cost el the repalcesumat ESTIMATED RUNTIME This displays the run time estimate of the UPS with the current battery Plugged into an AC outlet and turned How Long Do I Have To Make A Claim capacity and load on or when the UPS is on battery All claims must be made within ten days of the occurrence NORMAL icon This icon appears when the UPS is working under normal conditions What Will We Do To Correct Problems BATTERY icon During a severe brownout or blackout this icon appears and an alarm sounds two short beeps followed by a pause to indicate CyberPower will inspect and examine the Product the UPS is operating from its internal batteries During a prolonged brownout or blackout the alarm will sound continuously to indicate the UPS s If the Product is defective in material or workmanship CyberPower will repair or replace it at CyberPower s expense or if batteries are nearly out of power You should save files and turn off your equipment immediately or allow the software to shut the system down CyberPower is unable to or decides not to repair or replace the Product if defective within a reasonable time CyberPower will refund SILENT MODE icon This icon appears whenever the UPS is in silent mode to you the full purchase price you paid for the Product purchase receipt showing price paid is required
15. sion IS proulbiice transformer to regulate voltage and provide safe power Since utility power is normal over 88 of the time TECHNOLOGY the GreenPower UPS operates primarily in its efficient bypass mode The GreenPower UPS is also manufactured in accordance with the Restriction on Hazardous Substances ROHS directive making it one of the most environmentally friendly on the market today
16. the cable in Shutdown your computer and turn the UPS off Wait 10 seconds and turn the UPS back on This should reset the unit The unit is not providing battery power Additional troubleshooting information can be found at Support at www CPSww com DEFINITIONS FOR LED INDICATORS amp AUDIBLE ALARMS Limited Warranty and Connected Equipment Guarantee val al Read the following terms and conditions carefully before using the CyberPower AVRG750LCD AVRG900LCD the Product By CONDIHON using the Product you consent to be bound by and become a party to the terms and conditions of this Limited Warranty and Power Alarm Connected Equipment Guarantee together referred to as this Warranty If you do not agree to the terms and conditions of this Warranty you should return the Product for a full refund prior to using it Who is Providing this Warranty Beep twice Utility Failure The UPS is providing power to battery power supplied outlets CyberPower Systems USA Inc CyberPower provides this Limited Warranty every 30 seconds from its battery What Does This Warranty Cover Rapid beeping every 1 2 Utility Failure The UPS is providing battery power Rapid beeping indicates This warranty covers defects in materials and workmanship in the Product under normal use and conditions It also covers equipment second the unit will run out of power soon that was connected to the Product and damaged because of the failure of the
17. uct the Purchase Date and the item s of Connected Equipment Have information on all applicable insurance or other resources of recovery payment that are available to the Initial Customer and Request INPUT voltage meter This meter measures the AC voltage that the UPS system is receiving from the LOAD BATT CAP INPUT OUTPUT RUN TIME eS OmOeT a x w ja 3 You must provide a dated purchase receipt or other proof of the original purchase and provide a description of the damage to your Y connected equipment utility wall outlet The UPS is designed to continuously supply connected equipment with stable output voltage In the event of a complete power loss severe brownout or over voltage the UPS relies on its X m i Dl 7 x ES o internal battery to supply consistent 110 120 output voltage The INPUT voltage meter can be used as Vam Va Nir 4 Pack and ship the product to CyberPower and if requested the item s of Connected Equipment a repair cost estimate for the a diagnostic tool to identify poor quality input power The Lep disiayAndicalse a variety damage to the Connected Equipment and all claim forms that CyberPower provides to you Show the Claim Number on the shipping OUTPUT voltage meter This meter measures in real time the AC voltage that the UPS system is of UPS operational conditions All label or include it with the product You must prepay all shipping costs you are responsible for packaging and shipment and p
18. uring the lifetime of the product UNPACKING Inspect the UPS upon receipt The box should contain the following a UPS unit b User s manual c USB device cable PowerPanel Personal Edition software is available on our website Please visit www cpsww com and go to the Software Section for a free download AUTOMATIC VOLTAGE REGULATOR The AVRG750 LCD AVRG9OOLCD stabilizes inconsistent utility power to nominal levels that are safe for equipment Unstable utility power can be damaging to important data and hardware With Automatic Voltage Regulation AVR damaging voltage levels are corrected to safe levels AVR automatically increases low utility power to a consistent and safe 110 120 volts HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT 1 Ensure that the equipment plugged into the UPS does not exceed the UPS unit s rated capacity If the rated capacities of the unit are exceeded an overload condition may occur and cause the UPS unit to shut down or the circuit breaker to trip 2 There are many factors that can affect the amount of power that your electronic equipment will require For optimal system performance keep the load below 80 of the unit s rated capacity HARDWARE INSTALLATION GUIDE 1 Your new UPS may be used immediately upon receipt However after receiving a new UPS to AN AI A 1 is ES i Je a for at least 8 hours Your UPS is equipped with an auto charge feature When the
19. urred the occurrence will be deemed outside the rated capabilities of the Product and the Limited Warranty is void CyberPower Does Not Cover or Operating Temperature 32 F to 104 F 0 C to 40 C Undertake Any Liability in Any Event for Any of the Following f _ 1 Loss of or damage to data records or software or the restoration of data or records or the reinstallation of software Operating Relative Humidity 0 to 90 NON CONDENSING 2 Damage from causes other than AC Power Line Transients spikes or surges on properly installed grounded and code compliant Size W x H x D 12 2 x 7 x 3 5 120 volt power lines in the United States and Canada transients surges or spikes on standard telephone land lines PBX telephone equipment lines or Base 10T Ethernet lines when properly installed and connected This exclusion applies for example to Net Weight TOLOS 14 a lbs fluctuations in data transmission or reception by CATV or RF transmission or fluctuations or by transients in such transmission Typical Battery Recharge Time 3 Damage from any circumstance described as excluded above with respect to the Product or T F 4 ere TE i 4 Damages from fire flood wind rain rising water leakage or breakage of plumbing abuse misuse or alteration of either the ypical Battery Life 3 to 6 years depending on number of discharge recharge cycles product or the Connected Equipment Recommended Battery Sealed Maintenance Free Lead Acid Battery 5 CyberPower e
20. xcludes any liability for personal injury under the Limited Warranty and Connected Equipment Guarantee CyberPower excludes any liability for direct indirect special incidental or consequential damages whether for damage to or loss of Safety Approvals UL1778 UPS cUL107 FCC DoC Class B property EXCEPT FOR AND ONLY FOR the specific limited agreement of CyberPower to provide certain warranty benefits regarding Connected Equipment under this Warranty loss of profits business interruption or loss of information or data NOTE SYSTEM FUNCTION BLOCK DIAGRAM Surge Suppressor Some States or Provinces do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may Output not apply to you 6 The Product is not for use in high risk activities or with aquariums The Product is not designed or intended for use in hazardous Input environments requiring fail safe performance or for use in any circumstance in which the failure of the Product could lead directly to Pad death personal injury or severe physical or property damage or that would affect operation or safety of any medical or life support device collectively High Risk Activities CyberPower expressly disclaims any express or implied warranty of fitness for High Risk Normal Mode Battery Mode TEELE EEE RE Activities or with aquariums CyberPower does not authorize use of any Product in any High Risk Activities or with A
Download Pdf Manuals
Related Search
Related Contents
NOTICE PT MECABLITZ 45 CL-1 - Galerie Crimestopper Security Products CS-865RKE Automobile Alarm User Manual SPECIAL BRANCH - Offset India Solutions Manuale Utente - Kawai Musical Instruments Manufacturing Co., Ltd. Manual do usuário - Epson America, Inc. Samsung Galaxy Note (10.1) Manual de utilizare 1 - Brother Copyright © All rights reserved.