1. The Components of the CVE ECO 2 RFT 13 How to operate the unit Maintenence and warranty Information for the installer Manufacturer s statement 0 EC Declaration of Conformity SPOANDAHRWN 1 Introduction Interior comfort and energy efficiency are becoming increasingly important considerations in building More and more equipment is being developed to control the climate within the home while meeting the requirements for comfort and energy efficiency One of these devices is the Heatrae Sadia CVE ECO 2 RFT extractor unit which is the heart of the whole house ventilation system AHeatrae Sadia CVE ECO 2 RFT has been installed in your home In this user manual you will find information about the necessity of good ventilation and how your Heatrae Sadia CVE ECO 2 RFT works Additionally we explain how to operate and maintain the unit It is important that you read this user manual thoroughly before using the ventilation system in your home It is also a good idea to keep the manual near your Heatrae Sadia CVE ECO 2 RFT unit Compliance with Building Regulations The 2010 Edition of the U K Building Regulations Approved Document F1 Means of Ventilation applicable in England and Wales details 4 clearly defined systems of ventilation to dwellings System 3 Continuous mechanical extract MEV is complied with by the new CVE ECO 2 RFT ultra high efficiency whole house extract ventilation system
2. System 3 Continuous mechanical extract requires a minimum high rate in each wet room to be achieved Kitchens 13 I s and both utilities and bathrooms 8 I s sanitary only 6 l s The minimum low rate is calculated by taking the number of bedrooms in the dwelling and applying the V s value from Table 5 1b In addition the rate should be no less than 0 3 l s per m of internal floor area all storey s plus for each additional occupant over and above the anticipated two for the first bedroom and one for each of the others a further 4 I s must be added to the extract rate The system provides quiet uninterrupted extract ventilation from the dwelling removing warm stale air via all of the wet rooms creating a permanent air path through the property from the dry habitable rooms Air is usually drawn into the property through background ventilators located in the building facades However if the system is being installed to solve an incoming airborne noise issue background ventilators may be omitted subject to the proven air tightness of the dwelling There is a boost facility on the fan which enables the extract rates from all wet rooms to be increased to counter increased pollutants cause by cooking or bathing activities The current Building Scotland Regulations refers to continuously operating mechanical extract ventilation in accordance with the guidance in BRE Building Research Establishment Digest 398 a pap
3. electronics consist of a basic printed circuit board with an integrated RFT receiver which will permit the RFT remote control switches to operate the switches The user should not touch any electronic parts they may be electrically live 6 How to operate the unit Individual CVE ECO 2 RFT ventilation systems can be controlled either by a three speed hard wired switch or by a wireless three speed RFT Radio frequency RF operation switch The RFT radio frequency operation switch transmitter can be used as a 3 position mode switch with timer feature for the CVE ECO 2 RFT ventilation unit This operation switch can be used to set the ventilation unit to one of the three ventilation modes capacities The modes are Mode 1 Low mode Mode 2 Medium mode Mode 3 High mode The low mode is used at night the medium mode during the day when there are people at home and the high mode when cooking showering or bathing The switch also has a timer The ventilation unit can be switched to high mode for a predetermined time by pressing the timer button The timer automatically 16 switches the ventilation unit to low mode after the time has elapsed The length of time set for the timer is determined by the user Press the timer button once to set the ventilation unit to high mode for 10 minutes Press the timer button twice to set the ventilation unit to high mode for 20 minutes Press the timer button three times
4. on top of the appliance Regularly inspect the appliance for visible defects If any faults are found contact Heatrae Sadia immediately The appliance must only be installed by a professionally qualified person Ensure that the electrical system to which the appliance is connected complies with applicable standards Use a multi polar switch with a minimum contact gap of 3 mm to install the appliance Switch off the appliance at the main switch a if the appliance does not function correctly b before cleaning the outside of the appliance c if the appliance is not to be used for any length of time Be careful to avoid damaging the electric circuit Do not use the appliance to control activation of water heaters room heaters etc nor should it discharge into the flues of any such appliances Ensure that the appliance discharges into a single duct dedicated to this product which is routed to the outside The air to be extracted from the dwelling must be clean i e free of grease soot chemical and corrosive agents explosive or flammable mixtures Keep the appliance intake and outlet valves grilles free to ensure optimum airflow at all times Electronic components The Heatrae Sadia CVE ECO 2 RFT fan contains parts which may be live Consult a professionally qualified installer in the event of an alleged fault All repairs and maintenance work should be carried out by a professionally qualified installer Maintenan
5. rate ventilation CVE ECO 2 RFT or One or more RFT switches with three speed settings 3 Individual ventilation system How the individual ventilation system works The extractor unit ventilates several rooms in the home through ducts fitted in the kitchen the bathroom the WC and all other wet rooms These are connected to the central extractor fan system To ensure there is a good distribution of air valves are fitted to the openings of the ventilation ducts in the rooms to be ventilated Air is extracted from the rooms through these valves while fresh air from outside enters the home through openings such as grilles in the walls and windows of living rooms and bedrooms 4 The CVE ECO 2 RFT central ventilation unit The CVE ECO 2 RFT was developed to maintain a comfortable climate within the home by means of an energy efficient and convenient technology The energy efficiency comes from the application of direct current motors The CVE ECO 2 RFT has the added convenience of radio frequency RFT remote control Energy efficient direct current motor The energy efficiency demands of homes and building practises are becoming increasingly stringent For this reason the Heatrae Sadia CVE ECO 2 RFT is equipped with direct current motors These make the unit very energy efficient and deliver significant savings on electricity costs up to 80 Innovative technology Anumber of innovative technologies have bee
6. to set the ventilation unit to high mode for 30 minutes If the operation switch is used by choosing mode 1 2 or 3 while the timer is in operation the timer is switched off and the ventilation unit operates in the chosen mode Hard wired 3 position switch 24 The CVE ECO 2 RFT can be operated using the 3 position switch HRS 3 Step one is used at night step two during the day when there are people at home and step three when cooking showering or bathing 4 CVE ECO 2 RFT 3 position switch HRS 3 LNL 230V 50Hz 7 Maintenence and warranty Maintenance Technical maintenance of the CVE ECO 2 RFT is not necessary However the unit will need to be cleaned once every three to four years depending on the accumulation of dust You can check yourself whether the extractor unit is very dirty but it must be cleaned by a qualified technician To check whether your extractor unit is dirty follow these steps Isolate the unit from the mains power supply Remove one or more of the blue sealing covers so that you can see the fan Inspect the fan for dust and dirt A little dust makes hardly any difference to the fan s performance If the layer of dust and dirt is more than 1 mm thick on the inside of the blades we advise having the fan cleaned Check the bearings You can do this by spinning the fan Check that the bearings don t make any noise Check that th
7. HEATRAESADIA CVEECO 2 SMARTER CLEANER WARMER Installer and user manual Safety War ning Do not use this appliance for functions other than those described in the booklet After removing the appliance from its packaging ensure that it is complete and undamaged In doubt contact Heatrae Sadia Do not leave the packaging within reach of children or the infirm Certain fundamental rules must be observed when using any electrical appliance including a never touch appliances with wet or damp hands b never touch appliances while barefoot c do not allow children to use the appliance without supervision d supervise infirm persons when using the appliance Store the appliance out of the reach of children and infirm persons if you decide to disconnect it from the power supply and no longer use it Do not operate the appliance in the presence of inflammable substances or vapours alcohols insecticides petrol etc Caution The following general instructions are important Follow the safety instructions to prevent fan damage and personal injuries Maintenance instructions must be followed to prevent damage and or excessive wear and tear The specifications in this manual may not be modified The fans may not be modified The motor module is only suitable for a 230V 50 Hz A C system Do not expose the appliance to the weather rain sun etc Do not place objects
8. arpets parquet newspapers and cigarettes contain substances that harm the health of the residents All the moisture such as water vapour and aromatic substances should be removed from the homes The correct use of the ventilation system is important Ventilation requires energy The correct use of the ventilation system can limit energy loss as much as possible Your home has a Heatrae Sadia CVE ECO 2 RFT system This system can contribute extensively to a healthy interior climate and an optimum comfort level Another advantage is that the electricity costs are lower than other ventilation systems The ventilation system can however only function correctly when used and maintained in a responsible manner Some data 5 to 20 of people have an airway disorder The number of house dust mite has increased a hundredfold in the past 25 years The number of people suffering from Chronic Non Specific Lung Disease has doubled in the last 15 years 10 Research has proven that fighting moisture in homes greatly contributes to the decrease of allergic reactions of people with an airway disorder The correct use and maintenance of your ventilation system makes this possible An individual ventilation system has been built into your home This self contained system allows you to adjust your individual ventilation system The system consists of the following parts CVE ECO 2 RFT extractor unit Valves Switch to select low or high
9. ce The ventilation unit should be inspected regularly for contamination Electrically discharge the unit before carrying out any work on it First isolate the unit from the mains supply and make sure that the unit is not re connected to the supply socket by yourself or anyone else before you have completed the work Rotating parts The CVE ECO 2 RFT fan contains rotating mechanical parts These parts will keep on turning for a few seconds after disconnecting the unit from the supply For this reason wait at least 10 seconds after isolating the product before opening the unit The fan will not be moving after these 10 seconds have elapsed Sharp edges of the ducts The valves in your home should also be cleaned regularly These can be removed from the wall or ceiling Beware of protruding duct sections These can be very sharp Replacing the valves The valves should always be placed back in their original locations Do not turn the valve during the cleaning process make sure to mark the setting before cleaning the valve If the valves are switched or set differently the ventilation volumes will no longer be correct and the ventilation system will not work optimally The bathroom may then remain humid for too long your toilet may be very cool or your kitchen may smell mouldy Contents Introduction Why is ventilation important is Individual ventilation system 2 11 The CVE ECO 2 RFT central ventilation unit
10. chinery into which it is to be incorporated is in conformity with the provisions of Machinery Directive 2006 42 EC for which the most important instructions can be found in the manual We explicitly state that the CE marking on the product only refers to the Low Voltage Directive 2006 95 EC and the EMC Directive 2004 108 EC After the submission of a declaration according to Annex IIA of the Machinery Directive for the entire installation the CE marking on the device also refers to the Machinery Directive 2006 42 EC 24 10 EC Declaration of Conformity According to Annex Il of the Machinery Directive 2006 42 EC We Name of installer Full address and country Hereby declare under our own responsibility to have installed the following product with type designation Mechanical extract unit type CVE ECO 2 RFT to which this declaration refers We declare the entire installation being a single machine in conformity with the Machinery Directive Place Date Name Position Signature Company Stamp 25 26 27 HEATRAESADIA SMARTER CLEANER WARMER HEATRAE SADIA HEATING Hurricane Way Norwich NR6 6EA www heatraesadia com SERVICE 0844 8711535 SERVICE FAX 0844 8711528 EMAIL heatraesadiaservice heateam co uk 28 36006183 issue 01
11. d has two potentiometers to adjust the ventilation unit The potentiometers can be adjusted to set the minimum and or maximum capacity Potentiometer 1 adjusts the low setting for the unit This potentiometer is limited on the lower side so there can never be too little ventilation The factory setting is 75 m h This potentiometer should be adjusted to achieve the minimum rate as defined in ADF If the minimum rate cannot be achieved at low speed then the medium speed should be set to the ADF minimum rate instead The medium speed is calculated automatically by the unit it is defined by a difference in the low and high speeds Potentiometer 2 adjusts the high speed setting This potentiometer has a factory setting of 225 m h The high speed should be adjusted to the high rate as defined in ADF The available range is 175 m h to 325 m h at 150 Pa When setting up the system if more ventilation is needed open the valves more fully to obtain the required capacity before adjusting the speed Increasing the rpms of the motor leads to increased energy consumption and higher noise levels Removal of the front cover The front cover can be removed using a screwdriver The clasp is on the left top side of the cover and the extractor case The cover can be pressed open by horizontally inserting a screwdriver into the clasp The cover can then be pulled out by hand 22 Removal of motor chassis with motor fan assembly There a
12. e 2 Why is ventilation important Ventilation is necessary In the past people built houses which were not air tight which leaked air for example at the connection point of the wall and the floor or roof Cracks were always visible around windows and doors All these openings ensured that large volumes of air moved in and out of the buildings When the wind was blowing the complete air content of the home was refreshed three to four times an hour This ensured very good ventilation of the home but a lot of energy was lost Construction methods have changed Floors walls and roofs are when possible constructed with a layer of insulation The insulation ensures that there are nearly no cracks and the airtightness is increased It is a misconception to think that there is still enough ventilation in a home without some type of ventilation system Ventilation is absolutely necessary in an air tight home to prevent problems related to humidity mould and the health of the residents Moisture content of the home Incorrect use of the ventilation system by the resident in combination with today s well insulated homes gives humidity an open field The moisture content in the home increases and can cause health humidity and mould problems A family of four persons produces 14 to 20 litres of moisture per day just by breathing sleeping cooking washing dishwashing bathing watering plants etc Many products such as textile c
13. e fan doesn t swing from side to 18 side If the fan is set in motion by hand it should only rotate a few times and then come to a standstill with a few jolts This is a characteristic of a direct current fan and is completely normal Depending on the outcome of the inspection the fan should be cleaned and or made ready for use Fit the blue sealing covers to close the inlets Re energise the mains supply Valves The valves have to be cleaned regularly to ensure the constant and reliable operation of the ventilation System and for your own health Make sure that the setting of the system air flow is not changed when you clean the valves The valve could be turned by accident and this would mean that the opening becomes larger or smaller Each valve should be placed back in the same duct opening in the same room from which it was removed Cleaning valves Valves without a filter can be removed from the duct opening The foam ring if applicable should be removed before cleaning the valve in warm water and washing up liquid Replace the valve in the duct opening after cleaning The valve should always be placed in the same duct opening it was removed from Maintenance of Ducting It is our recommendation that the ducting connected to the Extract Terminals located in kitchens utilities bathrooms and en suites needs to be inspected every 3 years and cleaned every 6 years Cleaning of the grille and duct
14. emoved with a screwdriver Insert the screwdriver Hi ce horizontally in the space provided on the top left and press open the cover You can then remove the cover by hand 2 gt lt 2 Note Disconnect the unit from the mains supply before removing the front cover ear P The blue covers on the unit close off the unused air inlets to prevent leakage of air and ensure that maximum capacity is used 14 Service module If there is a fault with the motor or electronics the technician can easily fix the unit by replacing the service module The warranty on the service module is for two years from the installation date For more information about the terms and conditions of the warranty see chapter 7 p 18 Motor driven fan The motor driven fan forms the heart of the ventilation unit and has been specially designed for the CVE ECO 2 RFT During the development of the direct current motor special attention was paid to low noise levels high efficiency and a high volume of air moved This contributes to a healthy and comfortable interior climate in your home and lower operating costs Electronics The electronics are also an important part of the unit When you change settings with the switch the electronics carry out your command The motor is set to the desired number of rpms to ensure sufficient ventilation The
15. er based on the former government department s and now private company own tests and recommendations specifically 0 5 air changes per hour throughout the property The Heatrae Sadia CVE ECO 2 complies fully with the recommendations contained within this document With the Government actively encouraging energy saving and a target for all new homes to be carbon zero by 2016 the Heatrae Sadia CVE ECO 2 RFT has been designed future proof The Code for Sustainable Homes was updated in October 2010 to reflect the changes to the 2010 Building Regulations Level 4 now requires a further 2596 reduction in CO2 emissions To achieve the three highest levels of reduction of carbon emissions the air leakage of the dwelling must be improved so significantly that continuous ventilation becomes the only appropriate method In addition it must be demonstrated that the ventilation system itself must be energy efficient The Heatrae Sadia CVE ECO 2 RFT with its low energy D C motor and innovative impeller has been independently tested by the Building Research Establishment BRE to the appropriate SAP Appendix Q test methodology and is therefore Appendix Q eligible 1 The Governments Standard Assessment Procedure SAP is a method assessing the energy performance of dwellings and SAP Appendix Q provides an allowance for the benefits of energy saving appliances products may be independently assessed and the results uploaded to the SAP websit
16. ing can be carried out with a damp cloth 8 Information for the installer Installation The CVE ECO 2 RFT can be used in various types of homes both in new building as well as renovation projects The unit can be installed at different places in the home for example in a loft space store room or cupboard The extractor unit can be installed in all positions using the mounting eyes provided against a wall on the ceiling and also on sloping surface The CVE ECO 2 RFT should be installed following the general and local safety and installation regulations and the instructions in this manual The CVE ECO 2 RFT requires 230V 50 Hz mains voltage The tolerance for the mains voltage is 5 A multipolar switch must be fitted with a minimum contact gap of 3 mm The feeder cable is 1 5 m long and the connection is located towards the top of the unit The ducts should be of the correct dimensions 125 mm diameter or 204 X 60 rigid 20 Fans and ducting in or passing through unheated voids or loft spaces should be insulated to reduce the possibility of condensation forming The unit can be connected in various ways RFT The CVE ECO 2 RFT unit is controlled using the radio frequency module For information about installing and operating the RFT option please refer to the handbook provided with the RFT remote control set 21 Setting the basic printed circuit board Potentiometer settings The basic printed circuit boar
17. n used in the development of the CVE ECO 2 RFT For example the unit has a single printed circuit board for both the regulating and the control electronics The construction 12 of the fan is also new The air is now circulated through the fan by cone shaped blades This results in more efficient propulsion of the air and thus to greater energy efficiency 5 The Components of the CVE ECO 2 RFT The CVE ECO 2 RFT is modular and has several different components This makes the system more reliable technically and simpler to service The unit is made of polypropylene a type of plastic This material has a long life and can be cleaned with a damp cloth Housing The housing of the CVE ECO 2 RFT is constructed to allow easy replacement of the parts which makes maintenance and cleaning very simple The unit can be mounted on the wall or ceiling using the mounting brackets provided The unit has five air connections The right port on the unit 1 see diagram p 14 is the outlet funnel for air extracted and blown outside The other four ports 2 see diagram p 14 are for the removal of the air from the home They are located as follows On the top left of the unit On the right side of the unit On the left side of the unit On the bottom of the unit see diagram p 14 Front cover 2 1 i fr To permit installation of the RFT set receiver or other work such as maintenance the unit s front cover can LEA H be r
18. re three slots on the motor chassis The clamps in the slots are released by inserting a flat blade screwdriver into the motor chassis and pulling the screwdriver handle towards the motor chassis After the clamps in all three slots have been opened in this way a lifting strip at the top right of the chassis can be used to remove the entire motor chassis including the motor and fan 9 Manufacturer s statement EC declaration of conformity According to Low Voltage Directive 2006 95 EC and the EMC Directive 2004 108 EC Declaration of Incorporation According to Annex IIB of the Machinery Directive 2006 42 EC Heatrae Sadia Heating Hurricane Way Norwich Norfolk NR6 6EA hereby declare under our sole responsibility that the following products 23 Mechanical extract unit type CVE ECO 2 RFT Is in conformity with the following EC Council Directives Low Voltage Directive 2006 95 EC EMC Directive 2004 108 EC and Applied Harmonised Standards EN60730 1 EN61000 3 2 EN61000 6 1 EN61000 6 3 RoHs Weee and must be regarded as partly completed machinery and is intended to be incorporated in a machine or to be assembled with other machines into a single machine or system to which the Machinery Directive 2006 42 EC applies We want to alert you that the product is designed to be incorporated in a ventilation system and that the partly completed machine must not be put into service until the final ma
Download Pdf Manuals
Related Search
Related Contents
Contenido Sony Ericsson W800i Lire un extrait - Editions Persée mft 96 .... mftn 96 .... b-mft 96 .... b-mftn 96 .... maxi Catálogo de producto (pdf esp) Franke Smeraldo Vigirex RH197P Merlin Gerin PRODUCT GUIDE Toshiba LEDEUD00131C lighting spot GPIB-232CV User Manual Silverstone SST-HE01 Copyright © All rights reserved.