Contents
1. User Manual ULTRA PHONE Ultrasonic partial discharge detector TYPE SE 15 TOEI ELECTRIC IND CO LTD T 350 1311 1157 Naka Shinden Sayama shi Saitama Pref TEL 04 2950 0711 FAX 04 2950 0715 WARRANTY Important Notice This certificate shall be presented in case of warranty services Retain this certificate after filling the part marked with Should defects appear under normal usage during warranty period the product is to be repaired free of charge according to our warranty rules Warranted during One Year after purchase Month Year Serial Number IMPORTANT SAFETY INSTRUCTIONS Keep sufficient distance in case of searching discharge for the high voltage electric apparatus such as power transmission lines or electric railway This may cause you being shocked Do not look at the laser irradiating port directly or aim at other person s eye It can cause eye damage or injure health CAREFULLY FOLLOW THESE INSTRUCTIONS TO REDUCE RISK Do not expose the product to rain or moisture The product is not water proof Do not store or use the product in a location subject to dust high humidity and temperatures where they are exposed to direct sunlight Replace the batteries only with the same or equivalent A type recommended by the company Do not touch or scratch the laser irradiating port or the ultrasonic sensor eyelet with any hard or pointed objects This may cause the product malfunction or is da
2. can lead to personal injury or death Do not proceed until the warning is read and thoroughly understood CAUTION amp IMPORTANT INFORMATION This icon indicates important information regarding equipment operation or maintenance or a situation or condition that can lead to equipment malfunction or damage Do not proceed until the warning is read and thoroughly understood NOTE This icon indicates important supplementary information about an activity or concept Product outline The discharge phenomenon happens by either pollution or insulation degradation of private electric equipment This product detects the ultrasonic wave emitted in such discharge phenomenon remotely so as to locate the discharge place by laser beam plotting The characteristics of ultrasonic wave detection can also be applied to detect and locate the place of air or gas leakage from pipes ULTRA PHONE SE 15 features Excellent sensitivity and directivity locates the point of occurrence The laser beam provides easy recognition of the point The digital display of the occurrence magnitude provides easy management Ta Calibration by distance Specification The level display value is calibrated as the distance from Specifications the product is 2 meters l oe Re sere If used at the deferent distance correct the read value by Sensi 30dB to 90dB the following means for reference at 2m distance from the product a The distance is 1 me
3. maged INSTRUCTIONS FOR USE Do not drop or strike strongly the product This may cause the product malfunction or is damaged Do not clean with benzene thinner or alcohol etc The dirt or stain of the body can be cleaned with a mild detergent and dried with a soft cloth Pay attention to the polarity in loading batteries to the product in order to avoid malfunction Remove the batteries from the product which will not be used for a long time and store them in order to avoid stain or malfunction by leakage Thank you for purchasing ULTRA PHONE SE 15 This product detects and measures magnitude level of the ultrasonic wave emitted in discharge phenomenon caused by either pollution or insulation degradation of private electric equipment on which high electric potential is imposed Introduction Do not use the product until the instructions in this document are read and thoroughly understood Save these instructions after being read in the location where they are accessible whenever necessary The company shall not be liable of any loss of any kind including but not limited to claims arising out of the use of the product or defects of the product Safety Precautions The following instructions are provided to prevent harm or any damages to you and other parties so as for the product to be used properly and safely Follow these instructions carefully WARNING This icon warns of a situation or condition that
4. recise measurement is not expected because of the directivity of the parabolic antenna Dimensional Outline Drawing Battery cover 152 Laser irradiating port 278 Parabolic antenna Power switch O i OOo N 036 00800 O 0g5900 oO Ultrasonic sensor eyelet Speaker 94 74
5. ter subtract 6 dB from the read Display 1dB valie Resolution b The distance is 2 meters use the read value as it is Measurement 1 to 3m l ce The dist 3 meters add 5 dB to th d value distance Distance from the product MONTE eas aie Berean ary eae Display device 7 segment LED Battery 4 AA batteries Battery life Approx 20hrs No signal alkaline battery Trouble shooting No display Batteries have died Replace batteries appears Batteries are not properly loaded Load batteries properly 0 to 40 C Not greater than 85 RH temperature non condensing 10 to 50 C Not greater than 85 RH temperature non condensing dimension With batteries Storage case not incl Accessories damaged Please contact the agent you purchased the product or 4 AA batteries our sales department User Manual This document Storage Case appears stained absorbent cotton etc Display lamp Batteries are dying blinks If issues are not fixed yet after above solutions the product may be XA part of the specifications may be modified without notice for improvement of the product F R CAUTIONS in handling batteries Do not expose batteries to heat or fire nor recharge them How to Handle The waste batteries shall not be treated as household waste Follow the regulations when disposing waste batteries or hand e Preparation Four AA batteries are used Remove the cover at back and load batteries per polari
6. ty guide The battery voltage is normal if the LEVEL display lamp is lit after pushing POWER button When the lamp is blinking replace batteries with new ones Also replace batteries with new ones when the lamp is blinking during measurement Push the POWER button and confirm small noise from the speaker Then rub fingers in front of the antenna to hear its noise and confirm the loudness by the display The laser is emitted from the port when the POWER switch is pushed It stops when the switch is released them over to the applicable collection point Remove batteries from the product which will not be used for a long time e Measurement Searching for the fault location The product is powered while the POWER switch is pushed It is turned off if you release the switch button However it remains showing the level displayed before switched off for a few seconds Look for the point where either the loudness of the speaker output or the value of the level display is at the maximum for locating the discharge point The plot by the laser beam at the position of the maximum value is the point of discharge 2 Measuring the acoustic pressure at the fault location The acoustic pressure level is the value which corresponds to the measured value at 2 meter distant from the product 3 Measurement distance Use the product at the range of 1 to 3 meters from the product If the distance is out of range p