Home

3352 Series

image

Contents

1. DVB ASI 270 1 485 Gbps SMPTE 292 2 97 Gbps SMPTE 424M 2006 Equalization Automatic up to 100m of Belden 1694A at 3 0 Gbps 200m at 1 485 Gbps and 350m at 270 Mbps Return Loss gt 10dB up to 2 97 Gbps Page 4 Fiberlink 3352 Series User s Manual Fiberlink 3352 Series Technical Specifications Technical Specifications 3352 Transmitter Specifications cont Serial Video BNC Loop Through Output Number of Loop Throughs 1 Signal Level DC Offset Rise Fall Time Overshoot Timing Jitter Alignment Jitter Re clocking Optical Output Connector Wavelength Emmiter Type Re clocking Fiberlink 3352 Series User s Manual 800mV 10 OV 0 5V lt 135 ps at 2 97 Gbps per SMPTE 424M 2006 lt 270 ps at 1 485 Gbps per SMPTE 292 0 4 ns to 1 5 ns at 270 Mbps per SMPTE 259M lt 10 of amplitude lt 0 2 Ul at 270 Mbps lt 1 0 Ul at 1 485 Gbps lt 2 0 Ul at 2 97 Gbps with color bar signal lt 0 2 Ul at 270 Mbps lt 0 2 Ul at 1 485 Gbps lt 0 3 Ul at 2 97 Gbps with color bar signal At 270 Mbps 1 485 Gbps amp 2 97 Gbps LC receptacle PC polish or ST 1310nm nominal FP Laser At 270 Mbps 1 485 Gbps amp 2 97 Gbps Page 5 Fiberlink 3352 Series Technical Specifications Technical Specifications 3352 Receiver Specifications Fiber Optic Input Connector LC receptacle PC polish or ST Wavelength 1100 1620 nm Maximum Input Power 0 dBm Serial Video BNC Ou
2. Loss of receive signal card version only Note The 3G HD and SD LEDs indicators are off when a non standard signal is applied Fiberlink 3352 Series User s Manual Page 9 Fiberlink 3352 Series Operating Pointers Troubleshooting Operating Pointers Remember to check attenuation of the fiber optic cable The system will only operate properly if these specifications fall within the range of the system s loss budget Troubleshooting Multimode fiber optic cable contains an optical fiber with a light carrying core that is only 0025 inches 62 5 microns in diameter Single mode fiber optic cable has an even smaller core only 00032 to 0004 inches 8 10 microns This is smaller than a human hair Therefore any minute particles of dirt or dust can easily block the fiber from accepting or radiating light To prevent this from happening always use the provided dust caps when ever optical connectors are exposed to air It is also a good idea to gently clean the tip of an optical connector with a lint free cloth moistened with alcohol whenever dust is suspected The status of the LEDs should provide the first clue as to the origin of any operational failure If these are off it usually means that the fiber is broken or has too much attenuation Next be certain that the input and output signal connections are correct An optical power meter such as the Fiberlink 6615 a visible light source such as the Fiberli
3. site testing of fiber networks during construction and maintenance procedures It can be used to measure the power of an optical signal reaching the receiving end of a fiber optic cable as generated either by a transmitter unit or by a light source such as the 6620 Fiberlink 6620 Three Wavelength Light Source The Fiberlink Three Wavelength Light Source offers a laser output at wavelengths of 1310 and 1550 nm and VCSEL output at 850 nm allowing for convenient on site testing of fiber networks during construction and maintenance procedures Fiberlink 3352 Series User s Manual Page 13 Fiberlink 3352 Series Accessories and Related Products Fiberlink 3360 3G HD SD SDI amp 4 Pair AES Audio Series i i j EN Zi L ER A An e E a ot gel r Gt The Fiberlink 3360 Series allows you to transmit 3G HD or SD SDI as per SMPTE 424M 2006 292 and 259 with the ability to embed up to 8 channels 4 pairs of AES EBU digital audio Convenient switches on the 3360 Series transmitter allow the operator to embed each of the four pairs of audio independently to strip previously serialized audio or to pass it through without modification At the receive end of the fiber optic link the operator can decide which audio pairs they need de embedded Audio signals are not required to operate the Fiberlink 3360 link and it can be used as a stand alone 3G HD SD SDI optical link Previously serialized data is lef
4. Communications Specialties Fiberlink 3352 User s Manual Fiberlink 3352 Series Bidirectional 3G HD SD SDI Transmission over one single mode fiber Bidirectional broadcast quality 3G HD SD SDI transmission over one single mode fiber The 3352 Series provides a cost effective method to send two channels of 3G HD SD SDI with or without embedded audio in opposite directions over one fiber ge Dila es Communications Specialties Inc World Headquarters 55 Cabot Court Hauppauge New York 11788 USA Tel 631 273 0404 Fax 631 273 1638 info commspecial com commspecial com Fiberlink 3352 Series Contents Contents WV CLC OIE J OOO gg HHHH HH eee need aves oes 3 Fa SS ee all wnn ae Yel lik eee andine we see a ee ee 3 Package COMING 2 304 5icatocaueacmieage set 0005 TAERE REEERE RAFET EURES 3 Technical Specifications Model Part Number Specifications 0 KK 4 General SPECIICALONS vx i hanrsicdegorn nancy iors hoes ee tecalaneorwnniens 4 Transmission Specifications 0 cc cece cece eee eee eneeeeeees 4 Receive SPECIICANONS sss ssdssukscaceeedeadue kk K k kk k k k e kk k e 5 Operating Loss Budgets ccc cece eect kK kK kk K k kk k k k 6 Maximum Useable Distance cece kK KK KK KK kK kK k k 6 ITistallatiori INS UCTIONS i xi kya k ya aA la ada a kal a Giya a W KEL 0R 2 Wan 7 Alarm Switch Settings amp Opt
5. als over entire link budget and operating temperature range e Compliant with SMPTE 424M 2006 259M 2006 292 2006 e Supports transmission of SMPTE 305M 2005 310M 2004 344M 2000 DVB ASI e Supports 3G HD SD SDI inputs with embedded audio and data and DVB ASI e 8db Optical Link Budget 2 97 Gbps e Wide operating temperature range 10 C to 50 C e Available in Box and Card versions e Card version compatible with the Fiberlink 6000A Rack Card Cage e Designed and Manufactured in the USA by CSI Package Contents e One Fiberlink 3352 Transceiver e This User s Manual Fiberlink 3352 Series User s Manual Page 3 Fiberlink 3352 Series Technical Specifications Technical Specifications Model Part Number Specification Unit Type Part Number Transceiver Box 3352 B7L LC 3352 B7S ST Transceiver Rack Card 3352 C7L LC 3352 C7S ST General Specifications Indicators Power Data Rate lock 3G HD SD DVB ASI Alarm Card Version Only Box Version Dimensions 6 5Wx1 15Hx6L inches 165 W x 29H x 152 L mm Weight 12 3 ounces 382 grams Slots in 6000A Card Cage 2 Power 9 24 volts AC or DC 3 25 watts 11 08 BTU Hr Operating Temperature 10 C to 50 C MTBF 145 000 Hours 3352 Transmitter Specifications Serial Video BNC Input Number of Inputs 1 Data Rate Range 19 4 Mbps to 2 97 Gbps Supported Standards SMPTE 259M 292 424M 2006 305M 310M 344M DVB ASI Re clocked Data Rates 270 Mbps SMPTE 259M
6. ect viewing of this radiation should be avoided at all times Fiberlink 3352 Series User s Manual Page 7 Fiberlink 3352 Series Alarm Switch Settings amp Options Alarm Switch Settings amp Options The Rack Card version of this product has an additional red indicator LED that illuminates when an alarm condition exists The rack card unit also provides an output to drive a model 6020A Alarm Sensing Module which provides an audible tone and activates a set of contacts for external signaling purposes Alarm Switch Settings for the Transmitter Card Switch Position Alarm Indication On Off Loss of transmit signal Enabled Disabled Loss of receive signal Enabled Disabled Page 8 Fiberlink 3352 Series User s Manual Fiberlink 3352 Series LED Indicators Indicator LEDs The Fiberlink 3352 Series has four integral indicator LEDs that are used to monitor the state of the unit Card versions have an additional Alarm LED Indicator LEDs Status Definition On Indicates that correct power has been applied Off Indicates no 3G SDI or HD SDI data rate lock On Indicates 3G SDI or HD SDI data rate lock at 2 97 Gbps or 2 97 1 001 Gbps or 1 485 Gbps or 1 485 1 001 Indicates no SD SDI or DVB ASI data rate lock On Indicates SD SDI or DVB ASI data rate lock at 270 Mbps Alarm On Loss of transmit and or receive signal card version only Transmit LOS On Loss of transmit signal card version only Receive LOS On
7. ect the video source to the video input BNC connectors on each transceiver unit 2 Connect the video output cable to one of the two video output BNC connectors on each transceiver unit 3 Terminate any unused BNC output connectors at 75 Ohms 4 Connect the fiber optic cable to each transceiver unit 5 Connect the Universal Power Supply to each transceiver unit For box versions using DC power please refer to figure 1 6 When power is applied the green POWER LED should illuminate indicating the presence of operating power The 3G HD SD RATE LED will give an indication as described in the Indicator LED s and Alarm Circuitry section of this manual 7 The system should now be operational Note The Rack Card version has an additional LEDs for indicating the presence of an alarm condition and loss of signals Refer to Indicator LED s and Alarm Circuitry sections of this manual Figure 1 Power Connector DC Input Polarity Negative Positive 9 24 Volts AC or DC The transmitting element in the Fiberlink 3352 transceiver unit contains a solid state Laser Diode located in the optical connector This device emits invisible infrared electromag netic radiation which can be harmful to human eyes The radiation from this optical connector if viewed at close range with no fiber optic cable connected to the optical connector may be sufficient intensity to cause instantaneous damage to the retina of the eye Dir
8. ions kk kk KK kK k kk kk k k k l 8 Helena EEDE rb eeac ees err JJJ rJ J yj11 9 Operating Pointers 2 2 cic kek kK kK kK kk kk kk kk k kk kk kek ee ee e e eke 10 lse a ola SED _ c 5nmoamrmmrprmrbprrr r ma di 10 Maintenance and Repairs kk KK kk kK kk k kk kk k 11 ewaney a DxDDDw e_rwreenmnmxD F a a annnnammmm 11 Lac an ogoggg g e eo e gN egNAaAa a DM Iii 220_oo2za2Z2 2 px 12 Accessories and Related Products k kk kk KK KK KK KK kK kk k 13 Page 2 Fiberlink 3352 Series User s Manual Fiberlink 3352 Series Welcome Features Package Contents Welcome Thank you for purchasing Communications Specialties Inc s Fiberlink 3352 Series The 3352 Series is used to transmit two 3G HD SD SDI signals with or without embedded audio and data in opposite directions over a single fiber optic core The system delivers noise free transmission that retains all of the signals initial parameters regardless of fiber optic cable attenuation The 3352 Series also provides immunity to video pathological signals over the entire link budget and operating temperature range Features e Transmit two channels of 3G HD SD SDI one upstream one downstream e Signal is equalized and re clocked prior to fiber optic transmission e Features an equalized and re clocked SDI loop through e Features two equalized and re clocked SDI outputs e Immunity to pathological sign
9. ll materials must be shipped to CSI at the expense and risk of the Buyer CSI s obligation under this warranty will be limited at its option to either the repair or replacement of defective units including free materials and labor In no event shall CSI be responsible for any incidental or consequential damages or loss of profits or goodwill CSI shall not be obligated to replace or repair equipment that has been damaged by fire war acts of God or similar causes or equipment that has been serviced by unauthorized personnel altered improperly installed or abused RMA numbers and repairs can be obtained from Communications Specialties Inc 55 Cabot Court Hauppauge NY 11788 USA Tel 631 273 0404 Fax 631 273 1638 RMA numbers can also be obtained from our web site commspecial com Please have your serial number available Page 12 Fiberlink 3352 Series User s Manual Fiberlink 3352 Series Accessories and Related Products Fiberlink 6610 Visible Light Source The Fiberlink Visible Light Source provides a visible 650 nm laser output that can be used for identifying fiber breaks and individual fibers within fiber bundles allowing for convenient on site testing of fiber networks during construction and maintenance procedures Fiberlink 6615 Optical Power Meter The Fiberlink Optical Power Meter measures the power of optical signals at 850 980 1310 and 1550 nm wavelengths allowing for convenient on
10. nk 6610 and a Three Wavelength Light Source such as the Fiberlink 6620 can greatly assist and expedite troubleshooting of fiber optic transmission systems and are recommended tools all installers should have available Finally although multimode and single mode devices may look the same they will not operate properly together Using the wrong device or fiber can easily add more attenuation than specified resulting in poor overall performance It should be noted that some of our fiber optic products support both single mode and multimode fiber in the same unit If after reviewing the above possibilities the system is still not operating please contact the Customer Service Department for further assistance If you suspect your problem is caused by the optics or the fiber optic cable and you have an optical power meter please take the appropriate measurements prior to contacting support Page 10 Fiberlink 3352 Series User s Manual Fiberlink 3352 Series Maintenance and Repairs Certifications Maintenance and Repairs The Fiberlink 3352 Series has been manufactured using the latest semiconductor devices and techniques that electronic technology has to offer They have been designed for long reliable and trouble free service and are not normally field repairable Should difficulty be encountered Communications Specialties maintains a complete service facility to render accurate timely and reliable service of all p
11. roducts The only maintenance that can be provided by the user is to ascertain that optical connectors are free of dust or dirt that could interfere with light transmission and that electrical connections are secure and accurate Please see the Troubleshooting section of this manual for additional information An optical power meter such as the Fiberlink 6615 a visible light source such as the Fiberlink 6610 and a Three Wavelength Light Source such as the Fiberlink 6620 can greatly assist and expedite troubleshooting of fiber optic transmission systems and are recommended tools all installers should have available All other questions or comments should be directed to our Customer Service Department It should be noted that many problems can easily be solved by a simple telephone call If you suspect your problem is caused by the optics or the fiber optic cable and you have an optical power meter please take the appropriate measurements prior to contacting support Certifications C FC G Fiberlink 3352 Series User s Manual Page 11 Fiberlink 3352 Series Warranty LIM ITEDIWARRANTY Communications Specialties Inc CSI warrants that for a period of three years after purchase by the Buyer this product will be free from defects in material and workmanship under normal use and service A Return Material Authorization RMA number must be obtained from CSI before any equipment is returned by the Buyer A
12. t intact throughout the entire transmission process and the 3360 Series is immune to pathological signals over the entire budget link and operating temperature range Signals are equalized and re clocked prior to fiber optic transmission and the 3361 receiver features a re clocked SDI output The 3360 Series is compliant with SMPTE 297 2006 and has the ability to operate seamlessly with Fiberlink Matrix and other SMPTE 297 2006 fiber optic compliant devices Available in card versions and a small footprint box version it is ideal for broad cast or corporate studios OB vans rental and staging auditoriums stadiums and theaters airport or transportation hubs distance learning surgical or medical imaging and more Learn more at commspecial com Page 14 Fiberlink 3352 Series User s Manual Fiberlink 3352 Series Fiberlink 3352 Series User s Manual Page 15 Communications Specialties Fiberlink 3352 Fiberlink 3352 Series Bidirectional 3G HD SD SDI Transmission over one single mode fiber User s Manual Di CSI Senek World Headquarters 55 Cabot Court Hauppauge New York 11788 USA Tel 631 273 0404 Fax 631 273 1638 info commspecial com commspecial com 2011 Communications Specialties Inc All Rights Reserved Fiberlink and the starburst logo are registered trademarks of Communications Specialties Inc CSI and the triangle designs are trademarks of Communications Special
13. ties Inc P N 129215 Rev B
14. tputs Number of Outputs 2 Non inverting Independently Buffered Signal Level 800mV 10 DC Offset OV 0 5V Rise Fall Time lt 135 ps at 2 97 Gbps per SMPTE 424M 2006 lt 270 ps at 1 485 Gbps per SMPTE 292 0 4 ns to 1 5 ns at 270 Mbps per SMPTE 259M Overshoot lt 10 of amplitude Timing Jitter lt 0 2 Ul at 270 Mbps lt 1 0 Ul at 1 485 Gbps lt 2 0 Ul at 2 97 Gbps with color bar signal Alignment Jitter lt 0 2 Ul at 270 Mbps lt 0 2 Ul at 1 485 Gbps lt 0 3 Ul at 2 97 Gbps with color bar signal Re clocking At 270 Mbps 1 485 Gbps amp 2 97 Gbps Loss Budget amp Maximum Useable Distance Operating Loss Budget Single Mode Fiber 0 8 dB at 2 97 Gbps 0 11 dB at 1 485 Gbps 0 11 dB at 270 Mbps Maximum Useable Distance Single Mode Fiber 20 km at 2 97 Gbps 25 km at 1 485 Gbps 30 km at 270 Mbps Distance specifications are approximate and are not guaranteed Operating loss budget must not be exceeded Page 6 Fiberlink 3352 Series User s Manual Fiberlink 3352 Series Installation Instructions Installation Instructions The Fiberlink 3352 Series of fiber optic transmission systems are ready for immediate use and do not require any special tools or equipment However an Optical Power Meter such as the Fiberlink 6615 can be useful in determining optical loss budgets during your systems design and maintenance The following instructions describe the typical installation procedure 1 Conn