Home

IR Intelligent Speed Dome User`s Manual Version 1.0

image

Contents

1. 2 2 Set address dial switch mn Figure 2 3 d N 1 CD ii ke 4e TCE en The encode mode adopts binary system 1 to 8 is the valid bit The highest address bit is 255 You can refer to the following sheet for more information Address 1 2 3 4 5 6 7 8 1 OFF OFF OFF OFF OFF OFF OFF OFF 1 ON OFF OFF OFF OFF OFF OFF OFF 2 OFF ON OFF OFF OFF OFF OFF OFF 3 ON ON OFF OFF OFF OFF OFF OFF 4 OFF OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF ON ON OFF OFF OFF OFF ON ON OFF OFF OFF OFF ON ON OFF OFF OFF OFF ON ON OFF OFF OFF ON ON ON ON ON ON OFF ON ON OFF ON ON OFF ON ON ON OFF ON OFF OFF ON 254 255 3 Cable Connection 3 1 RS485 and Power Cable Connection There are three cable groups power cable RS 485 cable and video cable They are used to transmit video signal control signal and power connection Please connect the power cable to the power socket of the speed dome connect the RS485 cable to the RS485 port of the speed dome See Figure 3 1 and Figure 3 2 Power RS485 and Video Connection Figure 3 2 Name Function 485 A 485 A It is to control dome built in PTZ B 485 B It is to control dome built in PTZ GND Ground
2. 13 4 1 Screen uiec E seras saas 13 4 2 Self diagnosis System Information reete e eese eese tatnen estne teen re to tatnen tatnen tatnen sn eee ves sene rene 14 4 3 ETC E S 14 4 4 Menu Operation neret ett EROR IR tir I EEN ee beqe Ui tet ea ae sssrini teebes iasota io Sona astia 15 4 434 System Information see reen 15 4 4 2 Display Setting secet eae 16 4439 Camera Setting coit deese i ee erii et lige metet eie de ye eee 16 444 Function Settings ios teen ooa ehe eU I ntl ha i hti 20 4 45 dRElight Setup etre ert e aimed gi a etate i p RR 26 4 5 Dome Abnormal Phenomenon Operation sorsssrsnsossnenssssnsnsnsnnenssssnsnsnsnnenssssnsnsnsnnsnsnnsnsnsnssnsnssnsnsnsnssnnsnne 27 4 5 1 Restore to Factory Default Setup sese nnne nennen nnne nennen 27 4 5 2 PTZ Movement is not smooth W ssssseseserereere nerne erne ener enne enne nnne nn trennen entere nnns 27 57 FAQ e 28 5 1 Daily Maintenance E 28 5 2 Problems and Solutions 5 erret tertie eti rv te Von soes eee UIS PU ea pore s Ove VT Pe cnuasnavevebseensevonseveoses 28 6 APPENDIX I THUNDER PROOF AND SURGE PROTECTION eene 29 f APPENDIX II ABOUT RS485 BUS erret ter eren terere p e Sene o epe neo ea aus
3. BACK Go back to previous menu EXIT Log out system menu Note The dwell time between two orders should be less than one minute otherwise system will set to default value as one minute After click PROGRAM STOP do not click CALL button before icon disappears completely Any manual operation during the pattern procedure will terminate current dome pattern operation 4 4 4 6 Privacy Masking Window blank 23 Please make sure you current camera supports this function PRIVACY NO ACTIVATE RESIZE DELETE SAVE BACK EXIT Move the cursor to PRIVACY ZONE and click confirm button system goes to privacy mask setup interface The zone amount may vary due to different series product Note For security reasons please set privacy zone a little bit larger than the privacy object size Each time after modifications you need to move the cursor to SAVE button and then click confirm button to get all setup activated Otherwise privacy zone may not move correspondingly with the object Please enter privacy zone menu now all the privacy zones are closed Move the cursor to PRIVACY NO please use left right key to set different privacy zones For example shift to 001 section and then move the cursor to ACTIVATE Secondly use left right key to select ON mode Now there is a privacy zone in the screen centre Thirdly use PTZ to move camera so that privacy object fit well with screen centre Fourthl
4. means preset number And the SETTING column pops up an OK Now you successfully added a preset Please note you need to enable display preset title function first Main menu gt display setting gt preset title Repeat the above procedures to set more presets Once you want to modify a preset you can input the preset number you want to modify and then follow the above steps to set the preset You can successfully modify a preset content CALL Here is to recall preset Move the cursor to PRESET NO and then input corresponding preset value Then move the cursor to CALL and then click confirm button to go to a preset BACK Go back to previous menu EXIT Log out system menu For PELCO protocol user please refer to the following special functions Call preset Call preset 28 or preset 95 to go to dome menu Call preset 29 or preset 99 to go to scan Call preset 24 or preset 81 to go to pattern Call preset 25 or preset 82 to go to cruise tour Call preset 30 or preset 96 to stop scan or pattern Call preset 31 or preset 83 to begin rotation Call preset 33 to enable PTZ 180 degrees rotation Call preset 34 to set dome position as 0 Set preset Set preset 26 or 92 to set scan left limit Set preset 27 or 93 to set scan right limit Set preset 22 or 79 to begin record Set preset 23 or 80 to stop record 4 4 4 2 Pan PAN SPEED 160 RUN STOP BACK EXIT Move the cursor to PAN button and then click confirm button to go to set
5. AUDIO OUT Reserved audio port Audio output port Right now the device does not support this function GND Reserved audio port Ground port audio 9 Right now the device does not support this function IN Reserved audio port Audio connection port Right now the device does not support this function VIDEO GND Ground port OUT Video output port Power port connection interface is shown as in Figure 3 3 OHHH Figure 3 3 Name Function AC24V 24V power port Connect to the power cable EARTH Ground port AC24V 24V power port Connect to power cable 3 2 System Layout 3 2 1 BUS connection Please refer to Figure 3 4 and Figure 3 5 for BUS cable connection Input AC 220V Output AC 24V Video Output Transformer Figure 3 4 10 RS 485 Terminal resistance on Figure 3 5 Note Please use shielded twisted pair The shielded layer shall connect to GND firmly otherwise it may affect communication or video work 3 2 2 Star Connection Please refer to Figure 3 6 for start connection information Figure 3 6 3 3 Keyboard Connection This series dome supports keyboard operation You can use keyboard to control the dome and PTZ The display and control can work simultaneously One keyboard can control maximum 255 speed domes Please refer to Figure 3 7 mu Keyboard Su Figure 3 7 This IR intelligent speed dome protocol is open a
6. Manual Tilt Motion 0 1 120 S Manual Tilt Scan 0 180 Section Control Port RS485 BUS Baud Rate 1200 2400 4800 9600 Optional PTZ Scan Accuracy 0 06 0 015 Signal Format PAL NTSC Camera mode S N Ratio gt 50dB Effective Pixel 768 H 494 V 795 H gt 596 V 976 H X582 V Horizontal Resolution 480TVL 540TVL 700TVL Fan Fan works continuously Humidity lt 90 Environment 40 C 60 C Outdoor 2 Protocol Baud Rate Address setup Before you operate you need to set protocol baud rate and address Otherwise you can not control the product 2 1 Protocol and Baud Rate Setup Please configure the following settings before begin controlling dome e Address e Baud rate Parity Note Please reboot the speed dome to get all the setups activated Open the lower dome the interface is shown as below See Figure 2 1 SW2 OFF ON OFF ON Figure 2 1 SW1 OFF ON Figure 2 2 Please refer to the protocol sheets for detailed information Reserved Baud rate Parity 1200 Connect to the 120 2 1 2 3 4 5 6 7 8 ON Please note the speed dome cans automatically recognize the DH SD PELCO D PELCO P Usually you do not need to set Please refer to the baud rate sheet for detailed information Baud Rate 9600bps 4800bps 2400bps 1200bps Please refer to the parity setup sheet for detailed information
7. It is to set PTZ speed The value ranges from 1 to 3 Please use the left right button on the keyboard or in the speed dome terminal menu to set SET ZERO It is to set the PTZ initial position Please move the PTZ to the corresponding position and then click the confirm button to complete the setup POWER UP It is to set the dome operation when the speed dome boots up Click the confirm button to go to the next interface to set 25 MENU IDLE If current setup is ON once you open the menu and leave it idle for specified period the menu may automatically disappear If current setup is OFF the menu is always there and will not disappear Please use the left right button to set The option includes 1m 2m 3m 4m 5m off The default value is 1 minute PTZ AUTO STOP The speed dome will stop all the PTZ operations when there is no command for the specified time It includes various setups Please use the left right button to set HEATER SETTING Please highlight the current item and then click the confirm button to go to the next interface to set BACK Go back to the previous menu EXIT Log out the system menu Power Up Move the cursor to the POWER UP item and then click the confirm button you can go to the fourth menu POWER UP PARAMTER BACK EXIT POWER UP It is to set the PTZ operation when the speed dome boots up The option includes NONE AUTO SCAN PRESET PATTERN TOUR and etc Please use the left right button on the keyboard or
8. SHUTTER LOW LIMIT It is to set the camera slow shutter If the shutter time is too long it may affect the video real time feature o NOISE REDUCTION There may be noise when the camera is monitoring the low illumination environments You can use the digital filter to process the noise to guarantee the clear video o 3D NOISE REDUCTION System can reduce the noise according to the previous frames and current frame It has the sound noise reduction function but it may affect the video real time feature BACK Go back to previous menu EXIT Log out system menu 4 4 3 3 Day Night Setting Move the cursor to DAY NIGHT SETTING and then click confirm button you can go to the submenu DAY NIGHT SENSITIVITY SAVE BACK EXIT DAY NIGHT There are four options IR auto auto black and white color Please use the left right button on the keyboard or in the speed dome terminal menu to set SENSITIVITY It is the threshold value when the system switches from the black and white to the color in the auto mode BACK Go back to previous menu EXIT Log out system menu 4 4 3 4 Next Page Move the cursor to NEXT PAGE and then click confirm button you can go to the submenu PICTURE FLIP ON OFF FREEZE FUNCTION ON OFF FOCUS SENSITIVITY DEFAULT LOW STABILIZATION ON OFF CAMERA FACTORY DEFAULT CAMERA RESTATRT BACK EXIT PICTURE FLIP This function allows you to turn the image rotation 180 degrees There are two options on off
9. in the speed dome terminal menu to set PARAMTER Here you can set the serial number of the corresponding operation such as the scan preset pattern tour Please use the left right button on the keyboard or in the speed dome terminal menu to set BACK Go back to the previous menu EXIT Log out the system menu Heater Setting Move the cursor to the HEATER item and then click the confirm button you can go to the third menu 4 4 5 HEATER SETTING TEMPERATURE ENABLE TEMPERATURE DISABLE BACK EXIT HEATER SETTING There are three options auto on off Please use the left right button on the keyboard or in the speed dome terminal menu to set TEMPERATURE ENABLE The heater is on when the speed dome internal temperature is below the threshold you set here TEMPERATURE DISABLE The heater is off when the speed dome internal temperature is higher than the threshold you set here BACK Go back to the previous menu EXIT Log out the system menu IR Light Setup 26 IR SENSITIVITY 4 IRLIGHT CTRL ZOOM PRI NEAR LIGHT 50 FAR LIGHT 50 IRLIGHT COMP 03 BACK EXIT Move the cursor to highlight IR LIGHT SETTING button and then click confirm button IR SENSITIVITY Here you can enable the IR light sensitivity function SWITCH ZOOM It is the zoom rate of the near light and far light IRLIGHT CTRL There are three options Zoom rate has the higher priority height has the higher priority manual NEAR LIGHT It is the
10. medium and near light brightness FAR LIGHT It is the far light brightness IR LIGHT COMPENSATION It is the whole compensation level of the IR light 4 5 Dome Abnormal Phenomenon Operation 4 5 1 Restore to Factory Default Setup From main menu SYSTEM INFORMATION move cursor to FACTORY DEFAULT and click confirm button Dome will reboot and all the setups restore to factory default setup 4 5 2 PTZ Movement is not smooth From menu to SYSTEM INFORMATION move cursor to RESTART and click confirm button This reboot will not modify all activated setup such as preset tour and pattern 27 5 FAQ 5 1 Daily Maintenance Please clean dome cover regularly to get vivid image Handle the cover with care Use water to wash Don t use cloth to clean Use mild detergent to clean if there is too much dust Note The sweat from your hand may erode plating surface your nail may scrape dome cover result in blur image 5 2 Problems and Solutions SYMPTOM CAUSE SOLUTION No self diagnosis no video signal when I connect dome to power Red LED is not on 24V AC does not apply to the power Or connection is Check 24V AC power is connected or properly earthed too loose Check power supply condition Power off or Transformer or check 24V transformer problem Red LED light is on 24V AC power is low Something wrong with power socket Use multimeter to check dome load Ple
11. to the final explanation of us e Please visit our website or contact your local service engineer for more information 32
12. 12 IRIS SETTING NOISE REDUCTION 03 EXPOSURE COM i 3D NOISE CONTROL ON OFF SLOW AE BACK SLOW SHUTTER EXIT WDR ENBALE NEXT PAGE BACK EXIT AE MODE Here you can set the camera exposure mode It includes auto manual AV iris priority TV shutter priority Please use the left right button on the keyboard or in the speed dome terminal menu to set o Auto It becomes valid after you set the exposure compensation backlight compensation BLC slow shutter wide dynamic region WDR o Manual It becomes valid after you set the gain setting shutter iris setting wide dynamic region WDR o AV It becomes valid after you set the exposure setting iris setting wide dynamic region WDR o TV It becomes valid after you set the shutter setting exposure compensation wide dynamic region WDR GAIN SETTING The value ranges from 1 to 16 Default value is 2 Please use the left right button on the keyboard or in the speed dome terminal menu to set SHUTTER You can set shutter speed here The value ranges from 1 3 to 1 10000 Please use the left right button on the keyboard or in the speed dome terminal menu to set IRIS SETTING The value ranges from 1 to 18 Please use the left right button on the keyboard or in the speed dome terminal menu to set EXPOSURE COM The value ranges from 1 to 15 Please use the left right button on the keyboard or in the speed dome terminal menu to set SLOW AE In the strong l
13. ATURE Display dome internal temperature or not There are three options C F Off Please use the left right button on the keyboard or in the speed dome terminal menu to set TITLE DISPLAY Here you can set to display the speed dome title or not BACK Go back to the previous menu EXIT Log out system menu 4 4 8 Camera Setting 16 WB SETTING EXPOSURE SETTING DAY NIGHT SETTING FOCUS MODE AUTO FOCUS LIMIT 30CM ZOOM SPEED 08 DIGITAL ZOOM OFF APERTURE 09 NEXT PAGE BACK EXIT Move the cursor to CAMERA SETTING and then click confirm button you can go to the submenu WHITE BALANCE SETUP It is to set the camera white balance mode In includes auto ATW outdoor indoor mode 1 mode 1 mode 2 Please use the left right button on the keyboard or in the speed dome terminal menu to set EXPOSURE SETTING It is to set the camera exposure mode gain and etc Move the cursor to current option and then click confirm button you can go to the third menu DAY NIGHT Set day night mode There are four options IR auto black and white color auto Please use the left right button on the keyboard or in the speed dome terminal menu to set FOCUS MODE There are two modes Manual Auto Please use the left right button on the keyboard or in the speed dome terminal menu to set FOCUS LIMIT It is to set the distance between the camera and the object It can prevent the focus distance is too small which may result in focusing on the enclos
14. IR Intelligent Speed Dome User s Manual Version 1 0 0 Table of Contents 1 FEATURES AND FUNCTIONS inks ta cun ddxna nuu Ea nio daga dua d cuo nnd 1 1 GONe fal nte elle ERRREREROET TUS TU EORR EE 1 2 Id u PM TI NRI 2 1 On Screen Menu 20 enn ete t eet b eren Heer o p tete 2 2 On sscreen TIPS sic ternehmen nee NOSOP ER RO he uS 2 3 Support multiple protocols ede eve den nea UE reste e e ERE se 24 Proportional Fanan Tilt inch rA RR OA RD ERAN He ER 2 5 Preset Setup and Recall idi en btetee i d ee ee bit Re nn 263 AUTO SCAN c sess ees US etie enne ante ebbe entitatem 2 7 Auto Touring e nein se sis ana sin ei 12 9 Auto Patternzsesecetee dot etate meta AAE EA EEA teta etae teiten d RR UR He 29 Privacy Maskas uer nee eee teet ede de Beast she bin I ee 2 10 FEINIgbIUMISIOE a eis Bin EIER II eee eben Wii eae 2 11 DWG SEERE 2 12 Self diagnesis sets ee tani a drin i udi at A eet 2 13 Day Night Mode B W amp Color Mode sssssssseseseseseeeen renes 2 14 PUTO FOCUS sess acte tusanento moet og eit i re eit oto eit i arse edd oda etc e eid DER 2 15 Backlight Compensation etr eme pec i t Re e e RE deeds 2 16 Pan Tiltatid ZOO Messinia RH et OO OE PORRO ERRORI RARO Kee 2 17 3bntelligent LOCATON niiden e erre rtr dete nere tei de erre rtis 2 18 Idle Status x ose epe ooo UN Oven ae ede oque gto qe RR eod see de 2 19 Power UD
15. Please use the left right button on the keyboard or in the speed dome terminal menu to set FREEZE FUNCTION This function allows the system from one preset to another preset without showing the video during the PTZ movement There are two options on off Please use the left right button on the keyboard or in the speed dome terminal menu to set FOCUS SENSITIVITY It is the auto focus sensitivity STABALIZATION It is to remove the risk of the video vibration resulting from the speed dome movement CAMERA FACTORY DEFAULT SETTING Move the cursor to current item and then click confirm button to restore factory default setup CAMERE RESTART Move the cursor to current item and then click confirm button to reboot the camera 19 BACK Go back to previous menu EXIT Log out system menu Slight difference may be found due to different IR intelligent speed dome series 4 4 4 Function Setting PRESET PAN AUTO SCAN AUTO CRUISE AUTO PATTERN IDLE MOTION PRIVACY MASKING NEXT PAGE BACK EXIT Please go back to main menu and move the cursor to FUNCTION SETTING click confirm button You can see the above interface 4 4 4 Preset Setup PRESET Move the cursor to PRESET and then click confirm button to go to the third submenu PAN It is to set the speed dome rotation speed Move the cursor to PAN and then click confirm button to go to the third submenu AUTO SCAN It is to set the speed dome scan number and scan speed Move the c
16. SET NORTH DIRECTION Set dome benchmark direction so that you can know the angel between the benchmark and then current location Please move the cursor to the option and then click confirm button until you see O K Now you have set north direction LANGUAGE The dome menu language There are several languages for you to select Please use the left right button on the keyboard or in the speed dome terminal menu to set FACTORY DEFAULT Restore dome factory default setup Please move the cursor to the option and then click confirm button until you see O K Now you can see the IP dome begin rebooting to restore factory default setup RESTART Reboot the speed dome BACK Go back to the previous menu EXIT Log out system menu 4 4 1 1 Initialization information ADDR 001 H BAUD RATE 9600 PARITY NONE SOFTWARE V1 00 0 RHAGAD BACK EXIT Move the cursor to INITIAL INFORMATION and then click confirm button you can see the above interface Here you can view dome basic information 15 4 4 1 2 Address Information ADDR TYPE ADDR HARD ADDR SOFT BACK EXIT Move the cursor to SITE INFORMATION and then click confirm button ADDR TYPE There are two options soft and hard Please use the left right button on the keyboard or in the speed dome terminal menu to set Please note you need to reboot to activate current setup ADDR HARD It is an address you set in the dial switch You can not modify it through sof
17. XIT Move the cursor to highlight CRUISE item and then click confirm button to go to set interface CRUISE NO Here is to ser tour number The value ranges from 1 to 8 Please use the left right button on the keyboard or in the speed dome terminal menu to set CRUISE SETTING Move the cursor to cruise setting item and then click confirm button You can see the following interface Here you can add or remove the preset and set the corresponding dwell time and call speed One cruise can max include 32 presets The preset value ranges from 0 to 255 NO PRESET DWELL SPEED 01 000 005 013 02 000 005 013 03 000 005 013 32 000 005 013 B DWELL Here is t set dwell time The value ranges from 3s to 255s Please use the left right button on the keyboard or in the speed dome terminal menu to set m SPEED The speed value ranges from 1 to 16 When you move the cursor to one cruise number you can use left right button to turn the page There are 8 cruises in each page and there are total 4 pages When you move the cursor to one cruise number please click confirm button to set the cruise Please use up down button to set preset number dwell time and speed Use the left right button to go to the next cruise Click confirm button you can exit the setup After you completed the setup move the cursor to back button to go to the previous interface 22 DELETE CRUISE Here is to delete a cruise Input cruise number in CRUISE NO and then mov
18. ase contact retailer to replace power socket No self diagnosis There is a noise Power supply is inadequate Replace power socket Mechanical malfunction Need electrical engineer help Self diagnosis is ok No video signal Power connection is too loose connect tightly Check the circuit connection Connect again Video switch connection is wrong or improper operation Please refer to user s manual for cable connection information Self diagnosis is o k but I can not operate the dome Control circuit is not properly connected check control cable connection Dome address protocol or baud rate setup is not right Please refer to user s manual for detailed information Video signal loss occurs in high speed rotation Power supply is not sufficient Replace power socket Video signal is not successive Circuit connection is too loose Connect tightly Video switch or power problem Need electrical engineer help Video is not clear Focus is in manual mode Control manually Dome cover is dirty Wash dome cover During camera switch there is a tilt movement in the monitor Camera power is not in the same Phase When several domes are connected to one transformer please connect the transformer output cable to the domes same side 28 6 Appendix Thunder Proof and Surge Protection This series speed dom
19. asy syn Renan ena R e e Rasa e san Euh 30 ii 7 1 RS485 BUS Main FEAT vsccecisoiicUicccsescscesdsddectessdsouadcovosscosessosdeddeseutestsovosdDieusstestssceseesenteeesdsvsudoneccvessseeuadcsdseteest 30 7 2 RS485 Bus Transmission Distance susssesesenensnsnonsesenensnsnennnensnnenenenensnononnenenensnsnnnensnsenenenensnsnsnensenensnsnsnenensnsenen 30 7 3 Connection Methods and Terminal Resistance usssesesesessnsnonononsenensnsnnnenensnnnenenensnsnnnenensssenenensnsnensnsenensnsnene 30 7 4 The Problem in Practical Use ccssssssssssssssssscecesesssesessscsessssesesssesesassssesesesessscsessssssesesesesesessssesesesesnsececeseeseses 30 7 5 RS485 Bus FAQ pee H 31 8 APPENDIX TOXIC OR HAZARDOUS MATERIALS OR ELEMENTS 32 iii Welcome Thank you for purchasing our product This user s manual is designed to be a reference tool for the operation of your system Here you can find information about this speed dome features and functions as well as a detailed menu tree Please keep it well for future reference Before installation and operation please read the following safeguards and warnings carefully iv Important Safeguards and Warnings 1 Electrical safety e All installation and operation here should conform to your local electrical safety codes The power shall conform to the requirement in the SELV Safety Extra Low Voltage and the Limited power sou
20. ation easier It supports various languages and protocol auto recognition It supports 360 continuously pan 92 filt and 180 auto fli p It can realize no blind spot monitor This series product can be widely used in remote monitor environments such as electric power customs and water conservancy It is suitable for the monitor environments of low illuminations such as the village town and suburb 1 2 Features This series speed dome has the following features 1 2 1 On Screen Menu This series product menu supports multiple languages display and switch It is easy for you to view dome information and configure dome camera parameters 1 2 2 On screen Tips It is the screen operation prompt Here you can set call preset and display the preset number during the tour It can display preset title system software version speed dome position coordinates and etc 1 2 3 Support multiple protocols This series speed dome supports universally used protocols such as PELCO P and PELCO D You can use various devices such as matrix control keyboard and DVR and protocols to operate speed dome 1 2 4 Proportional Pan and Tilt This function keeps the image from moving too fast when there is a large amount of zoom Speed dome continually decreases or increases pan and tilt speeds in proportion to depth of zoom When zooms speed is increasing the camera moving speed becomes slow When zooms speed is decreasing the camera moving speed becomes fas
21. e Figure 6 1 Video Lighting Rod Communication _ Lighting Rod Power Lighting Rod The speed dome shall be installed within the 45 angel of the lighting rod Earth cable resistance shall be less than 40 Steel tube shield Figure 6 1 29 7 Appendix II About RS485 Bus 7 1 RS485 Bus Main Feature RS485 is semi duplex communication cable of impedance 1202 Its max load amount is 32 effective loads including main control device and devices to be charged 7 2 RS485 Bus Transmission Distance When we take 0 56mm 24AWG twisted pair as communication cable the max transmission distance theoretically are listed below according to different baud rates Baud Rate Max Distance 2400 BPS 1800M 4800 BPS 1200M 9600 BPS 800M In the following situations the max transmission distance shall become shorter accordingly The communication cable is a little bit thin The surrounding environment has strong electromagnetic interference There are too much devices connected to the RS485 bus And vice versa the max transmission distance shall become longer 7 3 Connection Methods and Terminal Resistance 1 RS485 bus requires all devices use the following connection methods Both terminals shall have 120 Q resistance See Figure 7 1 TWP e px Figure 7 1 Or you can refer to for the simplified way as in Figure 7 2 But the distance between D shall n
22. e adopts TVS lighting protection technology It can effectively prevent damages from various pulse signals below 1500W such as sudden lighting and surge While maintaining your local electrical safety code you still need to take necessary precaution measures when installing the speed dome in the outdoor environment The distance between the signal transmission cable and high voltage device or high voltage cable shall be at least 50 meters Outdoor cable layout shall go under the penthouse if possible For vast land please use sealing steel tube under the land to implement cable layout and connects one point to the earth Open floor cable layout is forbidden In area of strong thunderstorm hit or near high sensitive voltage such as near high voltage transformer substation you need to install additional high power thunder protection device or lightning rod The thunder protection and earth of the outdoor device and cable shall be considered in the building whole thunder protection and conform to your local national or industry standard System shall adopt equal potential wiring The earth device shall meet anti jamming and at the same time conforms to your local electrical safety code The earth device shall not short circuit to N neutral line of high voltage power grid or mixed with other wires When connect the system to the earth alone the earth resistance shall not be more than 42 and earth cable cross sectional area shall below 25 mm2 Se
23. e the cursor to DELETE cruise click confirm button to delete CALL Here is to activate cruise Input touring number in touring NO and highlight CALL click confirm button to activate touring e STOP Here is to terminate touring BACK Go back to previous menu EXIT Log out system menu 4 4 4 5 Pattern PATTERN NO 001 PROGRAM START PROGRAM STOP RUN STOP BACK EXIT Pattern function can memory PTZ operation and camera focus zoom in and zoom out From the start position dome begins auto movement repeatedly This series IP dome supports maximum 5 patterns and one pattern can max support 400 commands Move the cursor to PATTERN and click confirm button PATTERN NO Here is to set pattern number The value ranges from 1 to 5 Please click left right key to configure PROGRAM START Here is to memorize pattern starting point An icon OK pops up in screen to prompt you system begins memory pattern PROGRAM STOP Here is to set pattern stop point After all the movement move the cursor to PROGRAM STOP and then click confirm button Now you have set one pattern System pops up an icon OK to prompt you system has memories one pattern RUN Here is to activate pattern Input pattern number move the cursor to RUN and click confirm button system begins running pattern e STOP Here is to stop current pattern Input pattern number move the cursor to STOP and click confirm button System stops current pattern
24. ight environment you can lower the camera exposure speed to capture the image and enhance the definition The value ranges from 1 to 16 The bigger the value the higher the exposure speed Please use the left right button on the keyboard or in the speed dome terminal menu to set SLOW SHUTTER In lower illumination environment you can lower the cameras auto exposure time to capture the image and enhance the definition Please note for the moving object the image trail phenomenon may occur Please use the left right button on the keyboard or in the speed dome terminal menu to set WDR ENBALE It is an abbreviation for wide dynamic region Please make sure your camera supports current function This function can adjust the video brightness when the contrast between the strong light and the dark light is too high Please use the left right button on the keyboard or in the speed dome terminal menu to set NEXT PAGE It includes BLC GAIN LIMIT SLOW SHUTTER LOW LIMIT NOISE REDUCTION 3D NOISE REDUCTION Move the cursor to the item and then click the left right button to set o BLC Itis an abbreviation for back light compensation System can compensate the object in the dark light to achieve a clear video Please use the left right button on the keyboard or in the speed dome terminal menu to set 18 o GAIN LIMIT It is to control the camera gain The video noise may be too high if the gain value is large in the low illumination o SLOW
25. n the central window and automatically zooms All of these allow you to trace precisely 1 2 18 Idle Status When there is no available order you can use menu to set dome idle status after specified duration The idle status includes turn to specified preset or go to scan tour or pattern function 1 2 19 Power up The speed dome executes the power up operation after it rebooted and completed the initialization The power up function includes auto preset scan tour pattern and none 1 2 20 Image Flip You can enable image flip in the menu The flip function allows you to view continuous video 1 3 Specifications 1 3 1 Performance Specifications All digital design All data are in the connection board No data loss when power off occurs e Integrated design high stability e IR intelligent speed dome max support 255 presets Support 8 auto EUR touring Each touring max has 32 presets Built in e 5 auto scan Decode 5 auto pattern Each pattern can max support 400 commands and the interval shall be less than 60s Built in direction indicator RS485 BUS control Support max 24 privacy mask zones Built in various adjustable protocols baud rate e Fine stepper driver stable performance react quickly precisely positioning e Integrated design tight structure Built in PTZ Elegant mechanical driver device Support 360 degrees continuous rotation no monitor blind spot e 0 17s rotation speed while maintain s
26. nd repositions itself for uninterrupted viewing of any subjects that passes directly beneath the dome 1 2 12 Self diagnosis There is a self diagnosis procedure when dome boots up e Tilt and vertical engine check Camera diagnostics Display dome information and diagnosis information such as address protocol baud rate type 1 2 13 Day Night Mode B W amp Color Mode System supports auto manual switch in low illumination You can specify the switch time Inthe auto mode and photosensitive resistance mode the camera can automatically switch the CCD level according to the light change In the manual mode it can use the menu or the button to realize the color display black and white display and schedule switch All the modes will have automatically activation operation on the IR light except the camera auto mode e This function works with the IR night vision function 1 2 14 Auto Focus Auto focus allows the lens to remain in focus during zoom in zoom out and motion functions to get vivid image You can use FAR or NEAR button to adjust focus manually 1 2 15 Backlight Compensation Balance the brightest and darkest sections of a scene to produce a more vivid picture 1 2 16 Pan Tilt and Zoom Supports zoom in and zoom out during tilt and pan movement In this period focus and iris are both in auto mode to get vivid image 1 2 17 3D Intelligent Location Working with DVR just click part of the current scene will be displayed i
27. nd supports multiple popular system platforms in today s market Please contact us freely if some matrix systems do not support dome camera communication 11 protocol The most direct and easy way is to use current system to process video signal and add some control keyboards to control speed dome See Figure 3 8 Matrix or multiple image Processor Keyboard Figure 3 8 12 4 Menu 4 1 Screen Menu Index Note ERR means current setup is invalid Please restore factory default setup Slight difference may be found in the parameter interface due to different product series SYSTEM INITIAL INFORMATION INEORMATION ADDR INFORMATION SYSTEM TIME SETTING SET NORTH LANGUAGE ENGLISH FACTORY DEFAULT RESTART DISPLAY SETTING CAMERA SETTING DIGITAL ZOOM APERTURE FUNCTION SETTING DERI PAGE IR LIGHT SETTING IR SENSITIVITY 4 IRLIGHT CTRL ZOOM PRI NEAR LIGHT 50 FAR LIGHT 50 IRLIGHT COMP 3 13 The above diagram illustrates the overall structure of the speed dome setup menu Note e ERR means current setup is invalid Please make sure all the cable connections are right 4 2 Self diagnosis System Information ADDR 001 H BAUD RATE 9600 PARITY NONE SOFTWARE V1 00 0R BACK EXIT After installation please connect speed dome to power The system goes on a self diagnosis and then it pops up the above interface to show the system information If there is anything wro
28. ng during the self diagnosis system pops up error code The above interface disappears after speed dome received the first command or the display time lasts for 40 seconds ADDR Here you can view dome address information For example 001 H 1 is the address number H is hard address mode S is software address mode Baud rate Dome communication baud rate Parity Communication parity bit format e Software Dome PTZ software version When you are using the control keyboard or the matrix host to control the device please make sure the control parameter of the keyboard or the matrix host is the same with the speed dome OSD including address baud rate parity Please make sure the cable connection is OK 4 3 Main Menu You can open the IP dome menu via control keyboard matrix or soeed dome control terminal SYSTEM INFORMATION DISPLAY SETTING CAMERA SETTING FUNCTION SETTING IR LIGHT SETTING EXIT SYSTEM INFORMATION Dome self diagnosis information address information set north direction language factory default setup reboot and so on DISPLAY INFORMATION Display dome preset title azimuth display direction zoom dome internal temperature and etc CAMERA PARAMETERS Set camera white balance setup camera exposure setup day night setup focus setup focus limit Zoom speed digital zoom aperture setup The next page includes flip freeze focus sensitivity stabilization factory default reboo
29. off can control RS485 Bus connection are not Connect RS 485 Bus again the speed good Replace RS485 Bus dome but is not e One RS485 bus is off Add terminal matching resistance smooth The distance between host and e Add RS485 distributor speed dome is too far Parallel connected too much speed domes 31 8 Appendix Toxic or Hazardous Materials or Elements Toxic or Hazardous Materials or Elements Component Name Pb Hg Cd Cr VI PBB PBDE Sheet Metal o o o o o o Plastic Parts o o o o o o PCB o o o o o 2 Housing o o o o o o Camera Driver o o o o o o Bearing o o o o o 7 Connection 2 5 Cable Motor O 9 O O O Q If possible Power 2 s o If possible Bracket E T E d If possible Accessories o o o o o o Note O Indicates that the concentration of the hazardous substance in all homogeneous materials in the parts is below the relevant threshold of the SJ T11363 2006 standard X Indicates that the concentration of the hazardous substance of at least one of all homogeneous materials in the parts is above the relevant threshold of the SJ T 11363 2006 standard Note e This manual is for reference only Slight difference may be found in the user interface e All the designs and software here are subject to change without prior written notice e If there is any uncertainty or controversy please refer
30. ot exceed 7M Main Control Device Figure 7 2 2 Please refer to chapter 2 1 for 1200 resistance information on the main board 7 4 The Problem in Practical Use In practical usage we usually adopt star type connection The terminal resistance shall connect to the furthest two devices Such as device 1 and device 15 in Figure 7 3 But this connection way does not 30 conform to RS485 Bus standard When the distances between devices are too long the signal reflection occurs and anti jamming decreases thus the signal reliability becomes very low You can see speed dome is not under control or speed dome is running automatically and can not stop E s iy Fr Main Control Device Figure 7 3 In this situation we recommend RS485 distributor This device can turn star type connection into the connection that conforms to RS485 bus industry standard which can avoid the above mentioned problems and enhance communication reliability See Figure 7 4 Figure 7 4 7 5 RS485 Bus FAQ Phenomenon Possible Reasons Solution Speed dome e Host address baud rate and e Modify host or speed dome setup can run self speed dome address baud rate e Switch RS485 positive end and diagnosis but are not match negative end can not control Positive and negative end of e Fix connection cable firmly it RS485 Bus are misconnected Replace RS485 Bus e Connection cable is loose e RS485 Bus connection are cut
31. rce is rated 24V AC in the IEC60950 1 We assume no liability or responsibility for all the fires or electrical shock caused by improper handling or installation Weare not liable for any problems caused by unauthorized modification or attempted repair 2 Transportation Security No heavy stress violent vibration or water splash are allowed during transportation storage and installation Please use the original packing material or the material of the same quality when you ship it back to the manufacturer 3 Installation Do not apply power to the product before completing installation Do not put object on the product 4 Environment This series product should be installed in a cool dry place away from direct sunlight inflammable explosive substances and etc The working temperature ranges from 40 C 60 C Outdoor Please keep it away from the electromagnetic radiation object and environment Please keep the sound ventilation Do not allow the water and other liquid falling into the device Please make sure the CCD CMOS component is out of the radiation of the laser beam device Otherwise it may result in CCD CMOS optical component damage 5 Daily Maintenance Current series product has no power button Please unplug all corresponding power cables before your begin installation or daily maintenance work Please keep the dustproof cap back to protect the CCD or CMOS part if
32. set IDLE TIME System idle period The value ranges from 1 to 720 minutes Please use the left right button on the keyboard or in the speed dome terminal menu to set IDLE ACTION There are several functions you can select NONE PRESET SCAN TOURING PATTERN Please use the left right button on the keyboard or in the speed dome terminal menu to set PRESET NO Here is for you to set preset number The value ranges from 1 to 255 System goes to specified preset when idle status is on AUTO SCAN NO The value ranges from 1 to 5 Please use the left right button on the keyboard or in the speed dome terminal menu to set System begins specified scan when idle status is on CRUISE NO The value ranges from 1 to 8 Please use the left right button on the keyboard or in the speed dome terminal menu to set System begins specified touring when idle status is on PATTERN NO The value ranges from 1 to 5 Please use the left right button on the keyboard or in the speed dome terminal menu to set System begins specified pattern when idle status is on SAVE Move the cursor to SAVE and click confirm button to save current setup BACK Go back to previous menu EXIT Log out system menu 4 4 4 8 Next Page Move the cursor to the NEXT PAGE and then click the confirm button you can go to the third menu to set the PTZ SPEED SET ZERO POWER UP and etc PTZ SPEED SET ZERO POWER UP MENU IDLE PTZ AUTO STOP HEATER SETTING SAVE BACK EXIT PTZ SPEED
33. t 1 2 5 Preset Setup and Recall Preset function is to save the address information such as PTZ pan tilt focus and etc to the memory so that you can quickly adjust the dome and PTZ to the correct position This series speed dome max supports 255 presets in PELCOD and PELCOP protocols 1 2 6 Auto Scan Camera scans back and forth regularly in a horizontal field Here you need to set left and right limit and scan speed You can set 5 scanning paths 1 2 7 Auto Touring Add addresses into a routine in a desired order and then set time and stop duration for each address The dome will begin an auto touring between these addresses You can set 8 touring paths 1 2 8 Auto Pattern Memorize dome operation such as pan tilt and zoom to repeat Focus and iris are in auto mode during auto pattern For each pattern the time should be less than 60 seconds You can set 5 pattern paths 1 2 9 Privacy Masking Privacy masking is a user defined four sided area that can not be viewed by you The masking area will move with pan and tilt functions and automatically adjust in size as the lens zooms You can set 8 privacy masking zones Depends on camera type 1 2 10 IR Night Vision In the night vision status it can use the IR light to spot the monitor object or you can monitor the environments in the low illumination at night 1 2 11 Auto Flip As long as you continue to hold the keyboard joystick in the down position the dome rotates 180 degrees a
34. t and etc FUNCTION SETTING Set preset pan auto scan auto cruise auto pattern idle motion and privacy mask function The next page includes PTZ speed initialization position setup power up menu idle time PTZ auto stop setup heater setting and etc e IRLIGHT SETTING Set dome IR sensitivity IR light control principle medium and far light bright far light 14 bright IR light compensation and etc e EXIT Log out the system menu 4 4 Menu Operation In the speed dome main menu you can use the left right button on the keyboard or in the speed dome terminal menu to configure the system menu Before setup please move the cursor to the current item you want to configure Inmain menu please click confirm button to go to the sub menu or use left right key to configure setup Use up down button to select back option and then click confirm button to go back to the previous menu Use up down button to select exit option and then click confirm button to log out system menu All setup here will not lose when encounter power failure 4 4 1 System Information INITIAL INFORMATION ADDR INFORMATION SET NORTH LANGUAGE ENGLISH FACTORY DEFAULT RESTART BACK EXIT INITIAL INFORMATION Move the cursor to INITIAL INFORMATION and then click confirm button to go to the third submenu ADDR INFORMATION Move the cursor to SITE INFORMATION and then click confirm button to go to the third submenu
35. table image e 180 degrees tilt continuous monitor Support zoom level has the higher priority default manual Built in IR Inthe night vision status it can use the IR light to spot the monitor light object or you can monitor the environments in the low illumination at night Built in zoom lens high IAS e Auto focus Fsolttion e Auto iris control integrated e Auto brightness control digital e Auto white balance i process e Auto day night switch Auto B W amp color switch color camera Preset title display View dome initial setup information Modify camera parameter OSD Set preset Set auto scan Set auto patter Set auto day night switch Auto B W amp color switch Set privacy mask zones 1 3 2 Technical Specifications Power AC 24V 3A 20 Includes temperature control circuit Camera Driver Consumption 11W IR Light Consumption s20W Decoder Built in Engine Stepper motor Preset 255 in PELCO protocol Auto Tour 8 Auto Pattern 5 Auto Scan 5 Privacy Mask Maximum 24 zones Information Address dome title dome coordinates temperature and etc Lens Adjust speed in accordance with lens Auto Rotation Tilt 92 auto rotates to pan 180 Auto Pan 0 360 continuously Manual Pan Motion 0 1 200 S Speed Preset Maximum 60 240 s There are 16 level You can set from the menu Speed
36. the device does not work for a long time Do not touch CCD CMOS component You can use the blower to clean the dust on the surface of the device You can use the dry cloth with some alcohol or mild detergent to clear if necessary e Do not use the volatility solvent such as the benzene or thinner or detergent with strong abradibility It may result in lens damage or it may adversely affect the device performance If there is too much dust please use the water to dilute the mild detergent first and then use it to clean the device Finally use the dry cloth to clean the device 6 About Accessories Always use all the accessories recommended by manufacturer Before installation please open the package and check that all the components are included in the package Contact you local retailer ASAP if something is missing in your package vi 1 Features and Functions 1 1 General Introduction This series IR intelligent speed dome product is an integrated high intelligent speed dome It adopts waterproof design and has small and delicate shape This is a digital and intelligent product of vivid video It supports the auto IR light enable function in low illumination environments and the near and far light intelligent control The installation is convenient The IR intelligent speed dome external ports adopt the buckle device to realize the quick installation There is waterproof interface for the pipe thread All of these make the install
37. tware ADDR SOFT You can set address via software It is to say you can use menu to modify dome address The value ranges from 0 to 254 Please use the left right button on the keyboard or in the speed dome terminal menu to set BACK Go back to the previous menu EXIT Log out system menu 4 4 2 Display Setting PRESET TITLE ON ON OFF AZIMUTH DISP ON ON OFF POSITION OFF ON OFF ZOOM DISP OFF ON OFF INSIDE TEMP OFF C FOFF TITLE DISP OFF ON OFF BACK EXIT Move the cursor to DISPLAY SETUP and then click confirm button you can go to the third submenu Please use the left right button on the keyboard or in the speed dome terminal menu to set After completed setup please click save button to save current setup PRESET TITLE Display dome preset title or not Please use the left right button on the keyboard or in the speed dome terminal menu to set You can go to Function Setup gt Preset section to set corresponding preset value and preset title AZIMUTH DISP Display dome current coordinates or not Please use the left right button on the keyboard or in the speed dome terminal menu to set POSITION Display the angel between the benchmark and then current location Please use the left right button on the keyboard or in the speed dome terminal menu to set ZOOM DISP Display speed dome zoom speed or not Please use the left right button on the keyboard or in the speed dome terminal menu to set INSIDE TEMPER
38. u a ene ann BRD ra Roe E Rer bins EE RR PROP EUER RETE EYE EE es 2 22 22 2 22 2 2 20 Image Flip sense ERE PERDER EBERT 1 3 S Pe ification RATER 1 3 1 Performance Specifications cecceecesescsssseseeeesesesesesescesesesecseneseeaescsesecsesesaescsececseseaeseseceeaeeesavseeeeseaeeetateesees 1327 Technical Specific ti ns 2 2 32 rasante esse Se 2 PROTOCOL BAUD RATE ADDRESS SETUP nuuussanssunannuuunnnununannunnnnnnnununnununnannnnnnnnnnnnnn 6 2 1 Protocol and Baud Rate Setup sssssssusususnsnsnsnssssssssssnsnsnenensnsnsnsnsnsnnnsnnnnnnsnsnsnsnsnsnssssssssssnsnsnsnsnsnsnsnsnsnsnsnssnsnsnsnsnse 2 2 Set address dial SWICK once erri een e sae dve dl eb de asc se eset eee vac ibo resin eee ode eve n e Pre Cue ci de Tees i 3 CABLE CONNECTION aaaea aaae cot iu Enna xs na a krR xS nau ER dp n Svid adus ep Cin Rd nen ARE ERR R uda 9 3 1 RS485 and Power Cable Connection sssusssssensossnenssssnensnssnensnssnsnsnsnnensnssnsnsnsnnensnssnsnsnsnnsnssnsnsnsnssnsnssssnsnsnssnnsen 9 3 2 System Layout erase pestes eerie S DERE ANSE SENERE SENE SENERE RE SES SES SS SEE SES ve estas eese tense tio SES SEER ESSENSEN 10 3 23 BUS conrnieclion cub es ed NONI 10 3 2 2 Star Gonnecliorsu tst aH bete tet trit deniedkid abhi ah het 11 3 3 Keyboard Connection eric eds doe ta Geo ie n eae so Dean aa Ue icta geo ernennen Dea nae ages 11 Az lbper
39. up interface PAN SPEED Set dome rotation speed The Value ranges from 1 to 255 Please use the left right button on the keyboard or in the speed dome terminal menu to set RUN Move the cursor to call item and then click confirm button The dome begins 360 degrees continuous rotation e STOP Highlight stop item and then click confirm button The dome stops rotation BACK Go back to previous menu EXIT Log out system menu 4 4 4 3 Scan SCAN NO 001 SET LEFT LIMIT SET RIGHT LIMIT SCAN SPEED 160 RUN STOP BACK EXIT Move the cursor to SCAN button and then click confirm button 21 SCAN NO Here is to set auto scan number The value ranges from 1 to 5 Please use the left right button on the keyboard or in the speed dome terminal menu to set SET LEFT LIMIT Here is to set camera left address Click confirm button to save current setup SET RIGHT LIMIT Here is to set camera right address Click confirm button to save current setup SCAN SPEED The value ranges from 1 to 255 Please use the left right button on the keyboard or in the speed dome terminal menu to set RUN Please input auto scan number first and then please move the cursor to RUN and click confirm button to activate auto scan function STOP Here is to terminate auto scan function BACK Go back to previous menu EXIT Log out system menu 4 4 4 4 Cruise Touring CRUISE NO 001 CRUISE SETTING DELETE CRUISE RUN STOP BACK E
40. ure At the same time you can change the distance to change the focus speed There are various options such 1cm 5cm 30cm 1m 5m 15m ZOOM SPEED The zoom speed value ranges from 1 to 8 The bigger the value the faster the speed Please use the left right button on the keyboard or in the speed dome terminal menu to set DIGITAL ZOOM There are two options on off Please use the left right button on the keyboard or in the speed dome terminal menu to set APERTURE It is to adjust the lens to achieve clear video The value ranges from 1 to 16 Please use the left right button on the keyboard or in the speed dome terminal menu to set NEXT PAGE It includes the following options picture flip freeze function focus sensitivity stabilization camera factory default setup camera restart Please use the left right button on the keyboard or in the speed dome terminal menu to set Click the OK button you can view the rest camera settings BACK Go back to previous menu EXIT Log out system menu 4 4 3 1 White Balance Setup WBMODE AUTO Move the cursor to WHITE BALANCE MODE and then click confirm button you can go to the submenu WHITE BALANCE MODE Set white balance adjustment mode It includes auto ATW indoor mode 1 mode 2 mode 3 Please use the left right button on the keyboard or in the speed dome terminal menu to set 4 4 3 2 Exposure Setting 17 AE MODE BLC ON OFF GAIN SETTING GAIN LIMIT 08 SHUTTER SLOW SHUTTER LIMIT 1
41. ursor to SCAN and then click confirm button to go to the third submenu AUTO CRUISE It is to set the cruise tour number and task Move the cursor to AUTO CRUISE and then click confirm button to go to the third submenu AUTO PATTERN It is to set the pattern number and etc Move the cursor to PATTERN and then click confirm button to go to the third submenu IDLE MOTION It is to set the idle movement and idle time Move the cursor to IDLE MOTION and then click confirm button to go to the third submenu PRIVACY MASKING Move the cursor to PRIVACY MASKING and then click confirm button to go to the third submenu NEXT PAGE It includes PTZ speed set zero power up menu idle PTZ auto stop and heater Move the cursor to the item and then click the confirm button to set Click the confirm button to view rest setting items BACK Go back to previous menu EXIT Log out system menu PRESET NO 001 TITLE PRESETO001 SETTING CALL BACK EXIT Move the cursor to PRESET button and then click confirm button to go to set interface PRESET NO Please use left right key to modify preset number The value ranges from 1 to 255 20 TITLE Title text is the label used for you to identify the camera System will automatically name a title for the camera SETTING Please input preset number first and then select the monitor zone Please move the cursor to setting and click confirm button The system will pop up a message PRESET Here
42. y move the cursor to RESIZE and then click left and right key to adjust privacy zone direction and size Fifthly move the cursor to SAVE and then click confirm button to exit PRIVACY NO Here is to set privacy mask zones Please use the left right button on the keyboard or in the speed dome terminal menu to set The value ranges from 1 to 24 ACTIVATE There are two settings on and off When activate function is on the privacy mask function will be activated and displays in the screen When activate function is off the privacy mask function will be closed and the blank will not displayed in the screen RESIZE Itis to adjust the privacy zone size Please continue pressing direction button to widen or narrow zone size is to narrow the horizontal width and is to widen the horizontal width 7 is to widen vertical height and is to narrow the vertical height SAVE Here is to save user setup e DELETE Here is to delete setup and the privacy mask zone disappears Click the OK button to set BACK Go back to previous menu EXIT Log out system menu 4 4 4 7 Idle Motion 24 IDLE FUNC OFF IDLE TIME 010MIN IDLE ACTION PRESET PRESET NO 001 AUTO SCAN NO 001 CRUISE NO 001 PATTERN NO 001 SAVE BACK EXIT When there is no available command for specified time dome automatically goes on the previous set functions IDLE FUNCTION There are two modes ON OFF Please use left right key to

Download Pdf Manuals