Home
USER MANUAL
Contents
1. RFID type Manchester 64 read only Max reading distance 8 cm Number of outputs 1 SPST NO relay output Nominal switching capacity 2 30V DC Max switching power 60 W de Max switching voltage 220 V DC output Max switching current 2 A Min switching capacity 10 uA 10 mV DC Insulation Basic do not connect mains voltage Dimensions L x W x H 80 x 110 x 26 mm Weight 80 g Ambient temperature 0 to 50 C Ambient humidity max 95 no condensation Maximum altitude 2000 m Mounting position vertical Transport and storage temperature 20 to 60 C Pollution degree 2 Protection class IP 30 O Longo programmable controller LPC 2 1D3 special module SMARTER LIVING SYSTEMS 5 PROGRAMMERS GUIDE Variables There are 22 bytes available for reading and writing from to ID3 module While whole frame of 26 bytes is transferred at a time LPC Manager variables described in the table below are accessed separately VBOOLS8 N variable range Comm status New ID received BIT2 BIT3 BIT4 BIT5 Remove switch status Door switch status VBOOLS8 N 1 variable range BITO BIT 1 BIT2 BIT3 BIT4 BIT5 BIT6 BIT7 Pushbuttons and LEDs can be added on the customer request Longo programmable controller LPC 2 1D3 special module VBOOL8 N 2 SMARTTEH LIVING SYSTEM
2. SMARTEH LIVING SYSTEMS USER MANUAL Longo programmable controller LPC 2 1D3 special module Version 8 SMARTEH d o o Trg tigrovcev 1 5220 Tolmin Slovenia Tel 386 0 388 44 00 e mail info smarteh si www smarteh si Longo programmable controller LPC 2 1D3 special module SMARTER LIVING SYSTEMS Written by SMARTEH d o o Copyright 2012 SMARTEH d o o User Manual Document Version 008 July 1 2012 lt a Longo programmable controller LPC 2 1D3 special module SMARTER LIVING SYSTEMS STANDARDS AND PROVISIONS Standards recommendations regulations and provisions of the country in which the devices will operate must be considered while planning and setting up electrical devices Work on 230 VAC network is allowed for authorized personnel only DANGER WARNINGS Devices or modules must be protected from moisture dirt and damage during transport storing and operation WARRANTY CONDITIONS For all modules LONGO LPC 2 if no modifications are performed upon and are correctly connected by authorized personnel in consideration of maximum allowed connecting power we offer warranty for 24 months from date of sale to end buyer In case of claims within warranty time which are based on material malfunctions the producer offers free replacement The method of return of malfunctioned module together with description can be arranged with our authorized represen
3. Table 4 K3 K3 1 9 VDC Power supply output K3 2 Digital input O 9 VDC 9 VDC digital input Table 5 LEDs amp Buttons Power LED on the upper side of the module Green LED indicates power supply status On power supply OK Off power supply missing or power off Internal fault LED on the upper side of the module Red LED indicates LPC 2 1D1 communication state On RS485 communication fault Off RS485 communication OK Green LED indicates On RFID key standard OK and ID OK J LED RFID key standard and card number valid number Red LED indicates FAULT X LED Dev Sonden O NDR Sn NO and number card number wrong Table 6 S2 RS485 ADDRESS Switch 1 Switch 2 0 OFF OFF 1 OFF ON 2 ON OFF 3 ON ON Longo programmable controller LPC 2 1D3 special module SMARTER LIVING SYSTEMS 3 2 Mounting instructions Figure 3 Housing dimensions 26 ae ed ij x Tr e Dimensions in millimeters All connections module attachments and assembling must be done while module is not connected to the main power supply outside the room It is advised to avoid direct sunlight or position near heating cooling source object Round flush mounting box e g Gewiss GW 24232 60 mm is recommended for installation A box must be installed with screw holes in the horizontal position The LPC 2 1D3 module sh
4. 1 L FEATURE ee EE E ee ee ne 2 SINS TAHAT ON ee aa a ar E 3 3 1 Connection SCHEINE een ee des Dane eue 3 3 2 Mounting INS TUCEIONS seen 5 D MOULE NA DCUING oarriero EEEE E outer ER EE ENN 7 4 TECHNICAL SPECIFICATIONS ae ae in 8 D PROGRAMMERS GUIDES tre caved ee ee res ce ews 9 O CHANGE Ss TE TE EE EE N 11 NOTES E E en E 12 jii e a Longo programmable controller LPC 2 1D3 special module SMARTER LIVING SYSTEMS 1 DESCRIPTION LPC 2 1D3 card reader RFID identification special module is used for a room door unlock On room entrance the identification card ID card must be approached to the identification module In case that ID card is read correctly correct RFID key standard the green LED switches on and a short whistle appears If ID card for correspondent room is valid valid ID card number green LED switches on again and a short whistle appears After few moments the electric lock will open use LPC Manager for function logics If the ID card number is wrong the red LED switches on and a longer whistle appears refer to the Table 5 LPC 2 1D3 is connected to the main control unit RS485 port using interconnection cable e g SIC4 7 which must be ordered together with LPC 2 ID3 reader When more special modules e g 4xLPC 2 1D3 are connected to main control unit splitter e g SPL 2 is also required refer to the Figure 2 LPC 2 1D3 module RS485 address 0 3 is selected through two switches on the back s
5. S variable range Relay output command BIT 1 BIT2 BIT3 Received ID OK command Received ID Fault command BIT6 BIT7 VBOOL8 N 3 variable range BITO BIT1 BIT2 BIT3 BIT4 BITS Pushbuttons and LEDs can be added on the customer request VWORD 16 N 4 variable range Received ID WORD1 Received ID WORD2 Received ID WORD3 WORD4 WORD5 WORD6 WORD7 WORD8 WORD9 WORD10 10 a Longo programmable controller LPC 2 ID3 special module SMARTER 6 CHANGES LIVING SYSTEMS The following table describes all the changes to the document Date V Description 1 7 2012 008 CGP General update 7 5 2010 007 Updated warranty permanence 2 8 2007 006 updated K2 output specs updated description about connecting to main control unit 26 4 2007 005 updated connection scheme updated power supply source 15 3 2006 004 Added relay contacts rating Added pollution degree class 27 3 2005 003 The initial version issued as LPC 2 1D3 module UserManual 11 Longo programmable controller LPC 2 1D3 special module SMARTTEH LIVING SYSTEMS 7 NOTES
6. els NOTE Signal wires must be installed separately from power and high voltage wires in accordance with general industry electrical installation standard Longo programmable controller LPC 2 1D3 special module SMARTER LIVING SYSTEMS 3 3 Module labeling Figure 5 Labels on housing Label 1 MC3 sample Label 2 MC3 sample LPC 2 MC3 S N MC3 S9 0500000190 P N 225MC304001001 DIC 16 05 Label 1 description 1 LPC 2 MC3 is the full product name 2 P N 225MC3040001001 is the part number 225 general code for product family MC3 short product name 04001 sequence code 04 year of code opening 001 derivation code 001 version code reserved for future HW and or SW firmware upgrades 3 D C 16 05 is the date code 16 week and 05 year of production Label 2 description 1 S N MC3 S9 0500000190 is the serial number MC3 short product name S9 user code test procedure e g Smarteh person xxx 0500000190 year and current stack code 05 year last two cyphers 00000190 current stack number previous module would have the stack number 00000189 and the next one 00000191 3 Longo programmable controller LPC 2 1D3 special module 3 SMARTTEH LIVING SYSTEMS 4 TECHNICAL SPECIFICATIONS Table 5 Technical specifications Power supply from main control unit LPC 2 MC7 Interconnection connector type Berg M Power consumption 0 5 W
7. ide of the module refer to the Table 6 NOTE For proper system configuration and data allocation please refer to LPC Composer software help menu LPC 2 1D3 module can be modified on customer request front label changed push buttons added LEDs added Please contact manufacturer for more information a Longo programmable controller LPC 2 1D3 special module SMARTTEH LIVING SYSTEMS 2 FEATURES SMARTEH Figure 1 LPC 2 1D3 special module Table 1 Technical data RFID identification OK J LED FAULT X LED Power LED Internal fault LED Digital input Relay output Longo programmable controller LPC 2 1D3 special module 3 INSTALLATION 3 1 Connection scheme Figure 2 Connection scheme SMARTTEH LIVING SYSTEMS SIC4 7 SIC4 7 SIC4 7 SPL 2 ID3 Backside connection SIC4 7 SMARTEH ID3 Longo programmable controller LPC 2 1D3 special module Table 2 K1 SMARTTEH LIVING SYSTEMS K1 1 GND Ground K1 2 9 VDC Power supply input K1 3 Standard RS485 A Data receive send line A K1 4 Standard RS485 B Data receive send line B Table 3 K2 K2 1 Voltage free contact Make contact NO K2 2 Voltage free contact Make contact NO
8. ould be positioned on the wall inside or Mounting instructions 1 Mount LPC 2 1D3 module back plate to the provided leveled place on the wall 2 Fasten 2 screws DIN 7981 or similar 3 mm max head height 3 mm to fix LPC 2 1D3 module to its place 3 Connect interconnection cable to the interconnection connector K1 Max allowed tractive force is 30N 4 Set the correct RS485 address S2 switch for LPC 2 1D3 refer to the Table 6 5 Power PWR green LED should switch on according to the Table 5 6 Mount LPC 2 1D3 module front plate to the back plate IMPORTANT Front plate must be placed in order that switch 1 according to the Figure 2 is pressed normally is released 7 Fasten the screw in the bottom carefully not too strong to fix the front plate to the back plate NOTE a Longo programmable controller LPC 2 ID3 special module SMARTER LIVING SYSTEMS LPC 2 MC3 main control module should be powered separately from other electrical appliance connected to LPC 2 system Signal wires must be installed separately from power and high voltage wires in accordance with general industry electrical installation standard Several RFID panels should not be mounted close to each other Minimum distance to next panel is at least 30 cm This restrict also applies in cases of mounting panels on both sides of the wall Adequate shielding material and provisions should be used to avoid interference between pan
9. tative Warranty does not include damage due to transport or because of unconsidered corresponding regulations of the country where the module is installed This device must be connected properly by the provided connection scheme in this manual Misconnections may result in device damage fire or personal injury Hazardous voltage in the device can cause electric shock and may result in personal injury or death NEVER SERVICE THIS PRODUCT YOURSELF This device must not be installed in the systems critical for life e g medical devices aircrafts etc If the device is used in a manner not specified by the manufacturer the degree of protection provided by the equipment may be impaired X Waste electrical and electronic equipment WEEE must be collected separately LONGO LPC 2 complies to the following standards e EMC EN 61000 6 2 EN 50082 EN 61000 6 4 EN 50081 e LVD IEC 61131 2 e Vibrations and climatic mechanical EN 60068 2 6 EN 60068 2 27 EN 60068 2 29 Smarteh d o o operates a policy of continuous development Therefore we reserve the right to make changes and improvements to any of the products described in this manual without any prior notice MANUFACTURER SMARTEH d o o Trg tigrovcev 1 5220 Tolmin Slovenia Longo programmable controller LPC 2 1D3 special module SMART EH LIVING SYSTEMS Index Longo programmable controller LPC 2 1D3 special module T DESCRIPTION a a A E E en ie
Download Pdf Manuals
Related Search
Related Contents
User Guide - City of Toronto Verbatim Candle 3000K 300lm USER`S MANUAL - GSI Highway Products A Annexes 1001 Hi - Ordre professionnel des inhalothérapeutes du AGILIA Sony CDX-CA400 User's Manual Grove - RTC User Manual 「かばん及びスーツケース Version1.0」 認定基準書(案) 2007年9月 - アイエイアイ Copyright © All rights reserved.