Home
User Manual - Interlogix
Contents
1. 48 Digia Il User Manual
2. Camera Each camera has its own submenu The number of submenus depends on how many cameras your Digia II supports Title Set the title for the camera up to 12 characters Recording Set the recording method for this camera which include the following e Disable the camera does not display in live mode and does not record Alarms the camera displays in live mode but records according to the Alarms menu settings e Schedule the camera displays in live mode but records according to the Schedule and Alarms menu settings e Continuous the camera displays in live mode and continuously records Frame rate Select the frame rate for this camera from 1 to 30 frames per second fps The frames available at any time are distributed across all recording channels continuous schedule alarms The recording resolution set in the Recording menu determines the fps See Zable 11 on page 46 Quality level Select the recording quality for this camera Choose lowest to 6 highest Covert Select to make the camera appear disabled but actually record to the method set Sequence list Select to include this camera in the sequence list Sequence works only in full screen view Dwell time Set the dwell time between 1 and 99 seconds This is a property of the sequencing function and defines how long the sequencing display will dwell on this camera Brightness Set the brightness level for this camera Default is 50 Contrast Set the c
3. This end user license agreement Agreement is a legal agreement between GE and You Read the following terms and conditions carefully before installing or using this Software This agreement provides a license from GE to use the Software It also contains warranty information disclaimers and liability limitations Installing and or using the Software confirms Your agreement to be bound by these terms and conditions If You do not agree with these terms and conditions do not install or use the Software or if already installed immediately cease all use of the Software and promptly uninstall all components of the Software 1 Definitions The following definitions apply to this document a GE with respect to title to or warranty of the Software means GE Security Inc a Dela ware corporation b Software means the executable software or firmware programs and accompanying documentation installed on the GE products plus any upgrades modified versions updates additions and copies of the software furnished to Customer during the term of the license granted herein c Documentation means all associated media printed materials and electronic docu mentation accompanying the Software d Licensed Product means the Software and Documentation e Customer means the person or organization or parent or subsidiary thereof who uses the Software for its intended purposes and excludes distributors authori
4. 1 16 1 8 1 4 and 1 2 slow motion increments You usually use this after you pause video Search The search function uses time and filter based searches Press to open the search screen Live Live mode displays video as it is happens Press to open the live video mode Export Export lets you transfer video to a USB device Press to open the export screen Display Display lets you access the video configurations your model has either full screen 4 9 or 16 channels Press this repeatedly to cycle through your unit s configurations Menu The main menu is where you configure your Digia II Press to open the main menu 1 to 16 Channel buttons open a camera s video feed your unit will either have 4 9 or 16 channels Press the channel number that corresponds to the video feed you want to view 4 gt av Use the directional buttons to navigate through menus Enter Select an option that is highlighted Use in combination to configure your display and freeze or zoom in on live video Front panel indicators The front panel indicators lets you monitor your Digia IL and include the following Power indicator Indicates there is power to the unit Record indicator Indicates that the system is recording Hard disk drive activity indicator Indicates the hard disk drive is active Alarm indicator Indicates an alarm is set Network access indicator Indicates the DVR s access to the network USB Use this in the export and firmware
5. identify the type of circuit intended cable type or relevant circuit characteristics Figure 8 Back panel connections 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 i Cioci goa 14C15C16C AUDIO SVGA IN Lan PARTIEL ELLE NC C NO cas ESC ANC FCRC TCC s p Olesa O I B S7S7S7STS7STSTST SISI 0 Ld m GE um OUT USB MAIN MONITOR ALARM OUT DC19V Ea Chapter 2 13 Installation Battery replacement When you replace a battery ensure the following e Replace a battery with the correct type e Follow the instructions when you dispose of used batteries Note Itis not expected for a user to have to change this battery only authorized service personnel WARNING Using an incorrect battery could lead to product failure battery corrosion and possible damage to the unit Dispose of used batteries according to local directives Upgrade firmware The latest firmware is available from GE Video Upgrade at http www gesecurity com videoupgrades To upgrade firmware do the following 1 Click the Digia II firmware link to begin the download The system notifies you when the download is complete Copy the file to your USB drive Plug your USB drive into either of the two USB ports on the Digia II unit Figure 8 on page 12 Press Menu 2 A A Log on to the Main menu use the default Admin passcode as the primary and the User passcode as the secondary See Passcodes on page 24 Scroll down to the System menu Press En
6. in the Camera menu It will switch to the next feed after the defined dwell time interval Event notifications Check this box to enable the alarm icons to display A M V F Output type Select the monitor signal type you require Choose VGA for computer monitors or BNC for TV monitors System The System menu includes both the System date amp time and System admin submenus System date amp time Use the System date amp time submenu Figure 24 to update your system settings Figure 24 System date amp time Chapter 4 User menus Digia II Menu System lt lt System Date amp Time gt gt Date Time Format MM DD YYYY 12 HR Set Date 12 19 2006 TUE Set Time 03 06 54p Daylight Savings Start On MAR 2ND SUN From 02 00a to 03 00a End On NOV 1ST SUN From 03 00a to 02 00a Time Synchronize Time Server 220 130 158 052 Time Zone GMT Time Update by DAY The menu options include the following Date time format Choose between MM DD Y Y Y Y DD MM Y Y Y Y and YY Y Y MM DD and between 12 HR and 24 HR Set date Set time Set the current date and time Daylight saving Check this box if you want to enable daylight saving time If you are setting up daylight saving time check this box last after you have specified all the other settings Start on Select when daylight saving time begins Choose the month the week last 1st 2nd 3rd and 4th and the day of the week you want applie
7. Digia II User Manual 0000000000000000 tee Digia Il Copyright Disclaimer Trademarks and patents Software license agreement Copyright O 2007 GE Security All rights reserved This document may not be copied in whole or in part or otherwise reproduced without prior written consent from GE Security except where specifically permitted under US and international copyright law Document number 10580078B May 2007 The information in this document is subject to change without notice GE Security GE assumes no responsibility for inaccuracies or omissions and specifically disclaims any liabilities losses or risks personal or otherwise incurred as a consequence directly or indirectly of the use or application of any of the contents of this document For the latest documentation contact your local supplier or visit us online at www gesecurity com This publication may contain examples of screen captures and reports used in daily operations Examples may include fictitious names of individuals and companies Any similarity to names and addresses of actual businesses or persons is entirely coincidental GE and the GE monogram are registered trademarks of General Electric Company Digia Il product and logo are registered trademarks of GE Security Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products Important
8. The Save to Avi button becomes active 4 Click Save to Avi Figure 13 Save to AVI Digia Player xi Les TT e g q er vu r 5 Select the frame rate for the AVI file under Images Per Second 6 Select whether you want the system to create the AVI file with or without audio 7 Click Save Play AVI files To play an AVI file once you have downloaded and installed the DivX codec just double click the file Your video should open in Windows Media Player 22 Digia II User Manual Activate a motion detection grid To define what areas of the camera image set off a motion event do the following 1 A E A o Set the motion detection to Partial Note Enabled cells are shaded green and disabled cells are blank Use the directional buttons to navigate through the grid Press Enter to begin the cell selection Use the directional buttons to select the cells you require Press Enter again to toggle all the selected cells The cells become enabled if they were disabled and disabled if they were enabled Press Menu to save your changes and exit back to the Alarms menu Chapter 4 User menus This chapter provides a description of your Digia II s main menu In this chapter O Digia FT Main WAN A A n on 24 Digia II User Manual Passcodes Table 3 indicates the passcodes and what menus and submenus you can access for your passcode type Passcode types include the following Administrative passcod
9. You can use the following features during playback e Quadrant configuration press Display repeatedly to cycle through available configurations Camera views press any Camera button 1 to 16 You can stop or increase the image size with the freeze or zoom functions You can press Export at any time during playback to open the Export menu The system transfers the date and time video information into the Export menu Chapter 3 19 Digia Il features Export video to a USB device You can export a recorded video file to a USB device To export recorded video do the following 1 Press Export on the front panel of the Digia II Figure 1 on page 2 2 The Export menu displays the video that you can export Figure 10 Figure 10 Export menu Digia 11 Menu Search Available Video Start 11 30 2006 06 33 58a End 12 19 2006 03 17 42p Camera No 01 Start Date 12 19 2006 TUE Time 03 27 46p End Date 12 19 2006 TUE Time 03 32 46p Export Type DGA Start Export Select the camera view that you want to export Set the start date and time of the recorded video that you want to export Set the end date and time of the recorded video that you want to export Set the export type Choose from DGA AVI or DGA player FL Er A te Highlight Start Export and press Enter to begin the export process The system assigns a name to the file in the following format CH YYYYMMDDHHMMSS YYYYMMDDHHMMSS CH is the channel number that r
10. a and Hawaii Puerto Rico Canada Outside the toll free area 503 885 5700 E mail gesecurity customerservice ge com nstechsrv ge com Fax 888 329 0331 888 329 0332 Note Be ready at the equipment before calling for technical support Online publication library Another great resource for assistance with your GE product is our online publication library To access the library go to our website at the following location http www gesecurity com In the Customer Support menu select the Resource Library link After you register and log on you may search through our online library for the documentation you need 1 Many GE documents are provided as PDFs portable document format To read these documents you will need Adobe Reader which can be downloaded free from Adobe s website at www adobe com Appendix A Reference tables This appendix provides all the default settings that came with your Digia II camera and a recording resolution reference table In this appendix Main menu default values CORTE dass Record MM coo van cans SCheduie MEE 0 A AAA Schedule MENU as capa pda danas nr LOTUS CON te di Network menu Recording resolution corriera STE MN A Recording TORINO cr 44 Digia II User Manual Main menu default values This section provides all the default values for the Digia II submenus which you can access from the Menu button on the f
11. act technical support I want to export video to a CD RW or DVD RW drive The Digia II supports external optical burners via the USB 2 0 port Check www gesecurity com or contact technical support for the latest list of compatible optical drives Chapter 5 41 Troubleshooting maintenance support The Digia II DVR boots up to a startup screen but does not progress to live mode The Digia II runs a self diagnostic test once the unit powers up If a failure is detected such as a fan hard drive or Ethernet the unit may not boot completely Contact technical support The Digia II DVR only records for a few hours Verify that motion recording is set up properly by following the instructions in Alarms on page 15 The DVR will record at a lower frame rate when motion has not been detected to conserve hard disk space Once a camera detects motion the DVR will record at a higher frame rate to ensure a higher resolution during motion events playback The monitor displays no picture First verify the equipment is wired properly Refer to your installation documentation for assistance Verify that all of the wires used work properly Verify that the recorder is properly powered There is no display coming from one of the channels on the DVR Verify that the problem comes from the recorder or the camera Take a working camera and plug it into the port that seems to not be working properly If you see a picture the original recorder or c
12. age 8 Freeze or zoom video To freeze live video or zoom you must be in full screen mode See Freeze or zoom video on page 9 Chapter 3 Digia Il features Search To locate recorded video from your Digia Is hard drive see Figure 9 and do the following 1 2 Press Search on the front panel The Search menu displays Select the search by type either Time or Filters Figure 9 Search GO ls JON A For Time set the date and time to search For Filters choose the starting date and time and the ending date and time to search and select the appropriate search option e Bycamera e By video that was triggered by an alarm Press Search Any results will appear on the Event list page Use the directional buttons to navigate through your entries to select the file you require To export the file press Export See Export video to a USB device on page 19 To play the file press Enter to view the video or for more specific information see Playback on page 18 When you finish you can either press Search to return to the Event list Live to return to live video or Menu to return to the Search menu 17 18 Digia II User Manual Playback The playback controls are on the Digia II front panel Figure 1 on page 2 To playback video directly from your unit do the following 1 2 3 Note Press Live to open Live video Press Play The system begins to play the last five minutes of recorded video
13. amera is faulty I received an onscreen event message Use the list below to resolve any system events that display onscreen Invalid start date Verify the Export start date is within the available video range Invalid start time Verify the Export end time is within the available video range Invalid end date Verify the Export start time is within the available video range Invalid end time Verify the Export end time is within the available video range Start date must be before end date Update Start date so that is before End date Start time must be before end time Update Start time so that is before End time No video available at selected time Update the time from Search time ensure the start and end times make sense No USB device found Verify you have a compatible USB device or reboot with the USB connected Checksum error file may be corrupt Load firmware onto a USB a second time and try again Digia II User Manual Contacting technical support For assistance installing operating maintaining and troubleshooting this product refer to this document and any other documentation provided If you still have questions you may contact technical support during normal business hours Monday through Friday excluding holidays between 5 a m and 5 p m Pacific Time Table 4 Service and support contact information Customer service Technical support Phone Toll free 888 GESECURity 888 437 3287 in the US including Alask
14. ay or disclose the Software also are restricted as provided by paragraphs b 2 and b 3 of the Rights in Noncommercial Technical Data and Computer Software Small Business Innovative Research SBIR Program clause at DFARS 252 227 7018 9 Acknowledgment You acknowledge that You have read and understand this agreement and agree to be bound by its terms You further agree that this agreement is the complete and exclusive statement of the agreement between You and GE and supersedes any proposal or prior agreement oral or written and any other communication relating to the subject matter of this agreement Use this product only for the purpose it was designed for refer to the data sheet and user documentation For the latest product information contact your local supplier or visit us online at www gesecurity com This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment The Eu
15. d From Set the hour and minute at which you would like the time to change and set the hour and minute you want the time to change to End on Select when daylight saving time ends Choose the month the week last 1st 2nd 3rd and 4th and the day of the week you want applied From Set the hour and minute at which you would like the time to change and set the hour and minute you want the time to change to Time synchronize Check if you want the Digia II to synchronize its time clock to an external source Time server Set the IP address of the external source you want to use as your time synchronizing server Time zone Choose between GMT GMT 1 2 3 3 30 4 4 30 5 5 30 5 45 6 6 30 7 8 9 9 30 10 11 12 and 13 and GMT 12 11 10 9 8 7 6 5 4 3 30 3 2 and 1 35 Digia II User Manual Time update by Select the time interval you want the system to update its time Choose between day week and month System admin Use the System admin submenu Figure 25 to set the system administration options Figure 25 System admin Digia 11 Menu System lt lt System Admin gt gt Language English OSD Color white Load Save Setting NO Firmware Upgrade NO Delete HDD NO Admin Pass Code Confirm User Pass Code Confirm Network Pass Code Confirm The menu options include the following Language English OSD color Select the color of your
16. d or deactivated in the Time periods submenu Figure 17 Figure 17 Time periods The menu options include the following Camera The list of schedules in numerical order Schedule Choose from Disable Weekday Weekend Daily and Monday through Friday Start Set the start time End Set the end time Chapter 4 29 User menus Camera The system administrator can assign a separate FPS and QL value for each camera that is recording by schedule in the Camera submenu Figure 18 Figure 18 Camera schedule Note The number of cameras for your Digia Il may be different from the number of cameras listed here The menu options include the following FPS frames per second Set between 0 and 30 QL quality level Set between 1 and 6 30 Digia User Manual Alarms Use the Alarms menu Figure 19 to control the alarm triggers for your Digia II Figure 19 Alarms Digia II Menu Alarms lt lt Alarm 1 gt gt Contact Alarm Disable Sensor Type NC Alarm Frame Rate 10 f s Alarm Quality Level 6 Highest Alarm Duration 05 Sec s Alarm to Full screen Motion Detection Disable Motion Sensitvity 7 Video Loss Event Buzzer Email Notification Select EXPORT to Copy Settings Select DISPLAY to Paste Settings The menu options include the following Alarm The current alarm being edited Contact alarm Select how you want the contact to funct
17. display Choose from white black red yellow magenta and cyan Load save setting Press Enter then up or down Select whether you d like to cancel the process load factory defaults load other settings or save settings Firmware upgrade Plug in a USB device that has the new firmware on it press Enter then use the directional buttons to select Firmware upgrade Enter the passcode default is 4444 Your USB device must have at least 5 MB of free space Delete HDD Press Enter then up or down Enter the passcode default is 4444 This will delete everything on the hard drive Admin passcode Change an admin passcode Confirm Reenter the passcode you entered as your Admin passcode to confirm User passcode Change a user passcode Confirm Reenter the passcode you entered as your User passcode to confirm Network passcode Change a network passcode Confirm Reenter the passcode you entered as your Network passcode to confirm Chapter 4 37 User menus Information Use the Information menu Figure 26 to update your unit information Figure 26 Information The menu options include the following DVR ID Enter a DVR ID Firmware version Displays your firmware version HDD size The size of the hard drive installed IP address The IP address of the unit MAC address The MAC address of the unit Model The model number of the unit Record time from The date the unit started recording Recording tim
18. e 4444 Gives you access to all the menus User passcodes 1234 Gives you access to only the Display and Information menus Table 3 Main menu hierarchy User type Menus Submenus Admin and User Camera Admin and User Record Admin and User Schedule Time periods Camera Admin and User Alarms Admin and User Network Network configuration Network e mail Network DDNS Admin only Display Admin and User System System date amp time System admin Admin only Information Chapter 4 25 User menus Digia Il main menu To access the Digia II Main menu do the following 1 2 3 Press the Menu button Enter either your admin or user passcode See Passcodes on page 24 From the Main menu Figure 14 use the directional buttons on the Digia Ils front panel to navigate through the menus Press Enter to select a menu option See Table 3 for a layout of the Main menu submenus Figure 14 Main menu 26 Digia II User Manual Camera Use the Camera menu Figure 15 to configure your camera s options Figure 15 Camera Digia II Menu Camera lt lt Camera 1 gt gt WEG Emil 23 Recording Continuous Frame Rate 1 is Quality Level 6 Highest Covert Sequence List y DWELL time 03 Sec s Brightness 50 Contrast 50 Saturation 50 Select EXPORT to Copy Settings Select DISPLAY to Paste Settings The menu options include the following
19. e italic Electronic version Hyperlinks to cross references related topics and URL addresses Monospace Text that displays on the computer screen Programming or coding sequences Safety terms and symbols These terms may appear in this manual A CAUTION Cautions identify conditions or practices that may result in damage to the equipment or other property A WARNING Warnings identify conditions or practices that could result in equipment damage or serious personal injury viii Digia Il User Manual Chapter 1 Introduction This chapter provides an overview of your Digia II and describes how to configure and use your Digia II In this chapter Product 220444 paa dabas 4 PRONE lt 2 ban Dei ain PERS ir ile no ii E ened BOC DONE cies cages A whaaeeS eens Monitor onsereen MEDI A A A A YER SS Digia II User Manual Product overview Your Digia II makes use of the latest compression technology MPEG 4 which displays superior recorded video making the Digia Il ideal for your surveillance requirements Installation is simple and the Digia II operation is intuitive since video navigation is similar to that of other video playback devices Your Digia II allows you to e View record and playback images simultaneously e Record on MPEG 4 for digital playback quality in both NTSC and PAL formats e Listen to full duplex high quality audio e Set full or partial motion detection e Record up to a
20. e speakers or another audio output device to the audio output connector of the unit 4 Connect an Ethernet cable from a computer network to the LAN port Note If you connect point to point you must use a crossover ethernet cable 5 Connect a monitor to the main monitor BNC connector 6 Connect any alarm inputs to the alarm input connectors The alarm inputs can be Normally open NO Where the relay contact is in an open state When the contact is closed an alarm is triggered from 1 to 60 seconds in duration Normally closed NC Where the relay contact is in a closed state When the contact is open an alarm is triggered from 1 to 60 seconds in duration NO trans Where a relay is in an open state When the contact is closed an alarm is triggered and will remain until the contact is opened again NC tran Where a relay is in a closed state When the contact is opened an alarm is triggered and will remain until the contact is closed again 7 Connect your external device such as an alarm panel to the following alarm output connectors e ALM COM common ALM NO normally open ALM NC normally closed Note These connectors have a built in relay which can trigger your external device 8 Connect the 19 VDC power supply to the unit and then connect it to the wall outlet To install your Digia II in a standard 19 inch rack you need to order the rack mount kit Digia2RK separately Note Non LPS or TNV output connectors
21. e to Either the current date or the last date the unit was recording 38 Digia Il User Manual Chapter 5 Troubleshooting maintenance support This chapter provides information to help you troubleshoot problems and contact technical support in case you need assistance with your GE equipment In this chapter FOR ROUE idas de 40 Contacting technical support 24 4544809824008 ARA 42 40 Digia II User Manual Troubleshooting This section provides information to help you diagnose and solve various problems that may arise while configuring or using your GE product and offers technical support contacts in case you need assistance See Contacting technical support on page 42 Troubleshooting your Digia II e I cannot log onto the Digia IT main menu First verify that you are using the correct admin passcode the default is 4444 for user passcode the default is 1234 Note The admin passcode will grant you access to all of the menus and allow you to configure all of the options The user passcode will only allow you access to the search export display and information menus If the default passcodes do not work try 1111 If there are no passcodes that work contact technical support Once you have access to the menus set the admin passcode and user passcode I cannot upgrade the firmware on my Digia II When you download the firmware files Windows may add a DAT file extension or a similar extension that Wind
22. ecorded this video The first Y Y Y YMMDDHHMMSS is the start time in year month day hour minute and seconds that the recording started The second Y Y Y YMMDDHHMMSS is the end time in year month day hour minute and seconds that the recording ended Note Verify that the channel you choose for export has video recorded during the time range selected If you export nonexistent video you can get a empty and unusable exported file 20 Digia II User Manual Play DGA files Once you have a DGA file on your USB drive you can use DigiaPlayer to view those files To view the files do the following 1 Insert a compatible USB drive into your computer s USB port Open the USB directory on your computer Transfer the DigiaPlayer exe file to your PC gt pon Double click the DigiaPlayer exe icon Figure 11 The DigiaPlayer opens Figure 12 Figure 11 Digiaplayer icon DigiaPlayer exe Digia Player MFC Application Figure 12 DigiaPlayer Digia Player x ES Security 5 Click Load file 6 Navigate to and load the DGA file 7 Double click on the DGA file to begin playback Chapter 3 21 Digia Il features Convert DGA files to AVI To save AVI files which are compatible with the Windows Media Player do the following 1 Download the DivX codec if you have not done so See Download the required DivX codec on page 14 2 Open your DigiaPlayer 3 Click Load File and select the file you require
23. ee GE does warrant that the media on which the Software is furnished will be free from defects in materials and workmanship under normal use for a period of thirty 30 days from the date of delivery Media Warranty Period Except as specifically provided therein any other software and any hardware furnished with or accompanying the Software is not warranted by GE Your exclusive remedy under this limited warranty for nonconforming Software shall be repair or replacement of the Software at the sole discretion of GE To obtain a repair or replacement of nonconforming Software contact GE Customer Service toll free at 888 GESECURity or online at www gesecurity com during the Software Warranty Period Except as expressly provided above the licensed product is provided as is without warranty of any kind either expressed or implied including but not limited to implied warranties of merchantability or fitness for a particular purpose and except as expressly provided above You assume the entire risk as to the quality and performance of the licensed product 6 Limitation of liability GE s sole obligation or liability under this agreement is the repair or replacement of nonconforming software and or defective media according to the limited warranty above In no event will GE be liable for damages whether consequential incidental or indirect nor for loss of data loss of profits or lost savings arising from use or inability to use the
24. ense the Software d copy or modify the Licensed Product for any purpose including for backup purposes 3 Term This Agreement is effective until terminated You may terminate this Agreement by uninstalling all components of the Software from all Machines and returning the Software to GE GE may terminate this Agreement if You breach any of these terms and conditions Upon termination of this Agreement for any reason You agree to uninstall all components of the Software and return the Licensed Product to GE All provisions of this Agreement relating to i disclaimer of warranties ii limitations on liability remedies and damages and iii GE s proprietary rights shall survive termination of this Agreement 4 Object code The Software is delivered in object code only You may not alter merge modify adapt or translate the Software nor decompile disassemble reverse engineer or otherwise reduce the Software to a human perceivable form nor create derivative works or programs based on the Software 5 Limited warranty GE warrants that for one 1 year from the date of delivery of the Licensed Product Software Warranty Period the functions contained in the Software will be fit for their intended purpose as described in the applicable Documentation from GE and will conform in all material respects to the specifications stated in such Documentation GE does not warrant that the operation of the Software will be uninterrupted or error fr
25. ere DC19V Power connection Use to connect your power adapter Monitor onscreen display Chapter 1 Introduction Figure 3 shows the Digia II monitor display in full screen mode the default view when you first power on your Digia II You must select your onscreen display OSD See Display on page 34 Figure 3 Digia II onscreen display Channel Event signal Speed Percentage Playback icon Status Date Day Time The Digia II onscreen display includes the following Channel Indicates the channel that is onscreen Event signal Indicates system events as described in Table 1 Table 1 Event descriptions Playback status bar Recording status bar Event Description A A camera alarm has been triggered M Motion has triggered a camera s alarm V Video feed malfunction F Fan malfunction H Hard drive malfunction 5 6 Digia II User Manual Playback Record status bar Displays the playback or record video date the recorded channel events and the location of the video on the hard drive Table 2 lists all onscreen display items that appears on both the playback and recording status bar including system events and playback icons Table 2 Onscreen display items System events Item Description Mnn Motion camera nn Vnn Video loss camera nn Ann Alarm camera nn Ran Video was recorded PR Power r
26. eturn PL Power loss FAN Fan failure H Hard drive failure RU1 Remote admin login RU2 Remote user login LU1 Local admin login LU2 Local user login Time Displays the time when the video is played or was recorded Percentage Displays the amount of hard drive space remaining Day Displays the playback day or the day the video recording day Icon Name gt Play Il Pause 4 Play in reverse Fast forward Reverse slow motion gt Forward slow motion Chapter 1 Introduction Monitor configuration Your Digia II can display a number of configurations including the following Four channel units full screen and 2X2 Nine channel units full screen 2X2 and 3X3 Sixteen channel units full screen 2X2 3X3 and 4X4 Figure 4 shows the channel icon and playback status bar for a 2X2 configuration Figure 4 Two by two monitor configuration CHO2 CHO1 CHO3 Digia II User Manual Shuffle camera views You can reposition the channels to the configuration you want To shuffle the camera views do the following 1 Press Display repeatedly until you display the configuration you require 2 Press Enter Select displays in the upper right Figure 5 3 Use the directional buttons to move Select to the quadrant you require 4 Press the channel number button you want to view For example to swap channel 2 with channel 1 press Enter to display Select and press 2 see Figure 5 Ads T
27. full month of video with hard drives ranging from 160 to 640 GB Export archive with ThumbDrive USB flash drive CD RW or hard disk drive to USB 2 0 e Operate through easy to use VCR style control buttons Firmware Firmware is the software that is embedded in your Digia II and ensures your unit operates smoothly You must download the firmware from GE s website see Upgrade firmware on page 13 Front panel The Digia II front panel Figure 1 lets you monitor and enable Digia II functions Figure 1 Digia II front panel Digia II a F REV R PLAY PAUSE PLAY F ADV SEARCH LIVE EXPORT DISPLAY MENU A 1 2 3 4 5 6 7 8 9 10 1 12 13 14 15 16 POWER RECORD HOD ALARM NETWORK o o o o o Indicator Channel USB lights buttons Chapter 1 3 Introduction Front panel buttons The front panel gives you quick access to the more common Digia II functions and include the following F Rev Fast reverse starts or increases reverse slow motion Press this once to rewind or repeatedly for 1 32 1 16 1 8 1 4 and 1 2 slow motion increments You usually use this after you pause video R Play Reverse playback plays the video in reverse Press to reverse playback Pause Pause stills the video during playback Press to use with the F REV or F ADV function Play Play starts playback of the selected video Press to begin playback F Adv Fast advance controls forward slow motion Press once to advance or press repeatedly for 1 32
28. ion Choose one of the following Enable When the contact alarm is triggered the record settings defined in this menu item override any other settings Disable The contact alarm cannot be triggered Group When this contact alarm is triggered all other group alarms are triggered otherwise the alarm behaves as if it were enabled Sensor type Select how the contact function Choose one of the following e e NC The contact is normally closed and the alarm resets after the period that is set in alarm due NO The contact is normally open and the alarm resets according to the period set in the alarm due period NC Trans The contact is normally closed and the alarm does not reset until the contact is reopened NO Trans The contact is normally open by default and the alarm does not reset until the contact is reclosed Alarm frame rate Select between off 1 2 3 4 5 6 7 5 10 20 and 30 fps Alarm quality level Select between 1 lowest to 6 highest Alarm duration Choose between 1 and 60 seconds Alarm to full screen Check this box if you want the video to go to full screen when an alarm is triggered Motion detection Choose between Disable Partial and Full If you set it to Partial it will take you into the motion detection grid see Activate a motion detection grid on page 22 Motion sensitivity Choose between lowest to 9 highest Chapter 4 31 User menus Video loss Check thi
29. ired DIVX codec ativan said EEEE AA ERANO NON SERIE 14 Download Digia Player 12524 dds ini sis dt AMAR ae dean 14 Digia IIS IA AA Re tee 15 OU iii it id ae 16 A siichab nes A ba bbagiad EE AAEE 17 PIQVDOCK cota Enebi ea ee eia ioa i EET AA ida 18 Export video toa USB Cenar di Sash Gouna esas SS 19 Play DGA TIES a no rennais nds line tee gen 20 Convert DGA files to AVI teneur eee cmt ele een net 21 NANA ane VER se a dig wna OT 21 Activate a motion detection grid 22 vi Digia II User Manual Chapter 4 Chapter 5 Appendix A User menus cis 23 PaSsSCOdeS sanar sr aaa 24 Digia ll Main MENU cisco tai es 25 COM is AM da anne AR Re MAR ne Ne 26 NA 27 EST a 10 0 som ear a nnn o E 28 A A CTA 30 NE WORK stos ais ied ace tds O A A da id 31 DIS BIG aii it A RER REEE IA ded DAA AA eae IA e 34 SM A A A A AAA 35 Imorat eta de a M ee oe 37 Troubleshooting maintenance support 39 Troubleshoot cosest raias en Re Sn en TN Ne eee as 40 Troublesh oting you Didi nseries A a dires 40 Contacting technical SUPport o ooooooccccoccccconccr cr 42 Online publication libra Y dd 42 Reference ODE errar rr rr A c 43 Main menu default values 44444442 ee 44 Camera MEN A Ad e ne 44 Recordmen id een s nat 44 An MENT RE Ge ne CE 44 ANS aora 45 NETWORK MEN ac da as asada 45 Display A
30. is na 45 SYSE EN Uea ir id a e da AAA edb E US 46 Recording resolution 422422452042 nueet Mende Mn dent eee de aad Ebert 46 vii Preface This is the GE Digia II User Manual for models Digia 204 Digia 209 and Digia 216 This document includes an overview of the product and detailed instructions explaining how to install the unit and how to set up the unit There is also information describing how to contact technical support if you have questions or concerns To use this document effectively you should have the following minimum qualifications e abasic knowledge of CCTV systems and components and e abasic knowledge of electrical wiring and low voltage electrical connections Read these instructions and all ancillary documentation entirely before installing or operating this product The most current versions of this and related documentation may be found on our website Refer to Online publication library on page 42 for instructions on accessing our online publication library Note A qualified service person complying with all applicable codes should perform all required hardware installation Conventions used in this document The following conventions are used in this document Bold Menu items and buttons Italic Emphasis of an instruction or point special terms File names path names windows panes tabs fields variables and other GUI elements Titles of books and various documents Blu
31. o customize the display further continue with Step 3 6 When you finish press Enter The unit stores your customized views for all displays Figure 5 Shuffle views CHO1 CHO2 Select Select Chapter 1 Introduction Freeze or zoom video To freeze live video or zoom in on live video do the following 1 Press Display until you are in full screen mode or press the channel button you require 2 Press Enter to freeze the video The Freeze message displays Figure 6 Figure 6 Freeze CHOT 3 Press Enter to enable the zoom function The Zoom message displays Figure 7 Figure 7 Zoomin CHOT 4 Use the directional buttons to navigate through the screen 5 When you finish press Enter to exit back to the live video mode 10 Digia Il User Manual Chapter 2 Installation This chapter provides instructions for hardware and software installation In this chapter Peat Wis is rps ipara ETRE EEE ed dueeed 12 Leis HARO on cay dea ad 13 Sotware ISTRIA SOR ERED ERS 14 12 Digia II User Manual Hardware installation You must install your Digia II in an area that is secure and away from water heat dust dirt and other substances that may damage the unit To install your Digia II see Figure 8 and do the following 1 Connect a camera to any one of the camera BNC connections 2 Connect a microphone or another audio input device to the audio input connector 3 Connect th
32. ol port 01600 Authentication Disabled Client access Enabled DDNS services Disabled Bandwidth savings 8192 KB DDNS server tzo com Display menu Use Table 9 to reset the default values for the Display menu Table 9 Display menu default values Setting Default value Setting Default value OSD Enabled Event notifications Enabled Sequence Disabled Output type VGA 46 Digia II User Manual System menu Use Table 10 to reset the default values for the System menu Table 10 System menu default values Setting Default value Setting Default value Recording resolution Date format MM DD YYYY OSD color White Time format 12 hour Admin passcode 4444 Daylight saving Disabled User passcode 1234 Time synchronize Disabled Network passcode 11111111 Language English Use Table 11 to determine what recording resolution would work best for the number of channels you are recording on your system Table 11 Frames per second distribution chart 1 channel recording D1 4CIF Recording resolution 2CIF 120 fps 4 channels recording 9 channels recording 30 fps 16 channels recording 1 9 fps 3 8 fps 7 5 fps 1 The maximum number of frames that you can record on one channel is 30 frames per second real time recording even when there are options for 60 to 120 frames per second Appendix A 47 Reference tables
33. om live mode Log on to access the Export menu Select Player from Export Type Scroll down and select Start Export NA amp D Press Enter Note You must not leave the player on the USB thumbdrive Transfer the player to the desktop since the throughput of USB does not work well with video Download from Digia Browser Digia Browser operates through your PC s web browser to access your Digia II For complete instructions refer to the Digia Browser user manual To use your remote browser to download the DigiaPlayer do the following 1 Open the remote browser Select the Playback tab Select the Clip Info sub tab e poir Select Download DigiaPlayer refer to the Digia Browser user manual for more information Chapter 3 Digia II features This chapter describes the Digia II features In this chapter o Li sors iii door iites Export video to a USB device Piar PA AA Convert DGA files to AVI Activate a motion detection grid 16 Digia II User Manual Features To invoke any of these features use the directional buttons on the Digia II s front panel see Figure 1 on page 2 To make a selection use the directional buttons to navigate and press Enter to select the selection highlighted Download player software Refer to Download DigiaPlayer on page 14 Shuffle camera views For this you must have 2 X 2 multi channel display mode or greater See Shuffle camera views on p
34. ontrast level for this camera Default is 50 Saturation Set the saturation level for this camera Default is 50 Chapter 4 27 User menus Select EXPORT to copy settings Press Export to copy the settings from this camera submenu to the clipboard Everything but the title is copied Select DISPLAY to paste settings If you copied settings from another camera submenu press Display to paste those settings in the appropriate places on the current submenu Record Use the Record menu Figure 16 to set the Digia II recording features Figure 16 Record The menu options include the following Resolution Choose the resolution you want to record at Choose from CIF 2CIF and D1 4CIF Prealarm Select this box to record prealarm video Records five seconds of video before alarm Audio Select this box to record audio Timestamp Select how you want the system to use time stamps Choose between Disable Top or Bottom to enable timestamps Note Timestamp is a permanent part of the recording and cannot be removed Autodelete mode Choose the number of days the system begins to delete footage Choose disable or between 1 and 255 days Disk overwrite Choose between Continuous or No overwrite 28 Digia Il User Manual Schedule Use the Schedule menu including the Time periods and Camera submenus to configure your camera s scheduling options Time periods You can set the time period the camera is activate
35. ows does not recognize Edit the firmware s file name and remove the DAT file extension Verify there is at least 5 MB of free space on your USB device I cannot record at 30 fps The unit supports up to 30 fps recording at D1 resolution 60 fps recording at 2CIF resolution and 120 fps recording at CIF resolution The unit distributes these frames across all the enabled channels evenly when the recording mode is set to continuous schedule or alarms so that if you are recording at 2CIF 60 fps with four channels enabled each channel will be capable of recording up to 15 fps By default all channels are enabled and recording at 2CIF resolution If you have a four channel unit you can do one of the following e Disable two of the four channels to be able to record at 30 fps on any channel at the default resolution of 2CIF e Change the recording resolution from 2CIF to CIF If you decide to record at D1 resolution on that same four channel unit then you will need to disable three of the four channels to be able to record at 30 fps I cannot get my Digia II to recognize my USB device When you export video insert the USB device into the USB port just before the last step so the Digia II has time to recognize the device Some devices may not be compatible If the unit does not recognize the USB device reboot the unit with the USB drive inside the USB port If your PC still does not recognize the device try another USB brand or cont
36. r the SMTP server This is optional Sender e mail address Enter the e mail address you want the e mail to come from This is required for SMTP operation Receiver e mail address Enter the e mail address you want the e mail to go to This is required for SMTP operation Chapter 4 33 User menus Network dynamic domain naming system DDNS Use the Network DDNS submenu Figure 22 to set your DNS network options Figure 22 Network DDNS The menu options include the following DDNS services Check this box to enable DDNS on the Digia II DDNS server Choose between www tzo com www sitelutions com or www dyndns org To set up an account see those websites for more information User Enter the user name of the DDNS account Password Enter the password of the DDNS account Record ID A record ID that your DDNS service provides for you FODN This stands for fully qualified domain name Enter this domain name here for example digia2 dyndns com 34 Digia Il User Manual Display Use the Display menu Figure 23 to enable special features that display during recording and playback in Figure 23 Display menu The menu options include the following OSD Check this box if you want the playback and record status bars to display Sequence Check this box to enable sequencing Sequencing will automatically switch the live view to the next available video feed where you have enabled Sequence List
37. ront panel Camera menu Use Table 5 to reset the default values for the Camera menu Table 5 Camera menu default values Setting Default value Setting Default value Title CH Sequence list Enabled Recording mode Continuous Brightness 50 FPS 1 Contrast 50 Quality level 6 Saturation 50 Covert Disabled Record menu Use Table 6 to reset the default values for the Record menu Table 6 Record menu default values Setting Default value Setting Default value Resolution 2CIF Timestamp Disabled Pre alarms Enabled Autodelete mode Disabled Audio Enabled Disk overwrite Continuous Schedule menu The default values for Schedules is all time periods disabled Appendix A 45 Reference tables Alarms menu Use Table 7 to reset the default values for the Alarms menu Table 7 Alarms menu default value Setting Default value Setting Default value Contact alarm Disabled Motion detection Disabled Sensor type NC Motion sensitivity 7 Alarm frame rate 10 fps Video loss Disabled Alarm quality level 6 Event buzzer Disabled Alarm duration 5 seconds Email notification Disabled Alarm to full screen Disabled Network menu Use Table 8 to reset the default values for the Network menu Table 8 Network menu default values Setting Default value Setting Default value Data port 00554 Network type DHCP HTTP port 00080 SMTP port 25 Contr
38. ropean Union directive on electromagnetic compatibility 2004 108 EC requires non European manufacturers to designate an authorized representative in the Community Our European representative is GE Security Kelvinstraat 7 6003 DH Weert Nederland The European directive Waste Electrical and Electronic Equipment WEEE aims to minimize the impact of electrical and electronic equipment waste on the environment and human health For proper treatment recovery and recycling return the equipment marked with this symbol to your local supplier upon the purchase of equivalent new equipment or dispose of it in designated collection points For more information visit www recyclethis com ISO 9001 CE Contents Chapter 1 Chapter 2 Chapter 3 Prefate aiii dalt dunia a ideados vii Conventions us d in this doc ius A ss vii Safety terms and symbol ete ccd dc nement ane scene RENE ad vii izo AAA A II 1 Product oVervi W sisisi stts aska ra e ii Kabeea tes 2 A O IN 2 A A anne SAAE Puces ones 2 Back panel das ron sra antennes Mine estate 4 MOnitoronscr enaiSplay ci dad 5 Monitor configuration obvias naa aa 7 SUS Camera VIEWS seisnes A A ea SARA a 8 Freeze ON ZOOM VIO aci a A 9 NOM riadas corre 11 Hardware installation lt ooocooroncion sesi n raras enceinte da aa 12 Batter r placeMent ise sus it A a AA A 13 Upgrade TirmWaTe bossa ii aa a at lie te 13 Software installation iii is A A rd 14 Download the requ
39. s box if you want this event triggered when video is lost Event buzzer Check this box if you want to hear a buzzer on motion alarms and video loss Email notification Check this box if you want the Digia II to send an e mail to a predetermined e mail address when the alarm is triggered Network The Network menu includes three submenus Network configuration Network email and Network dynamic domain system DDNS Network configuration Use the Network configuration submenu Figure 20 to assign your network settings Figure 20 Network configuration Digia II Menu Network lt lt Network Configuration gt gt Data Port 00554 HTTP Port 00080 Control Port 01600 Client Access Bandwidth Saving 8192 Network type DHCP IP Address 000 000 000 000 Subnet Mask 000 000 000 000 Gateway 000 000 000 000 DNS Server 168 095 001 001 The menu options include the following Data port Default is 00554 HTTP port Default is 00080 Control port Default is 01600 Client access Check this box if you want to enable access to the Digia II over a network Bandwidth saving Limits the bandwidth of the network stream Default is 8192 KB Select between 10 and 8192 KB Network type Select your network type Choose between Static and DHCP DHCP will assign values to the IP subnet gateway and DNS server values automatically 32 Digia II User Manual IP The IP address of the unit If you choose
40. software or documentation or any hardware furnished with the software even if GE has been advised of the possibility of such damages nor for any claim by any third party 7 General Any materials provided to You by GE shall not be exported or reexported in violation of any export provisions of the USA or any other applicable jurisdiction Any attempt to sublicense assign or transfer any of the rights duties or obligations hereunder shall be void This Agreement shall be governed by and interpreted under the laws of the State of New York United States of America without regard to conflicts of law provisions You hereby consent to the exclusive jurisdiction of the state and federal courts located in Multnomah County Oregon to resolve any disputes arising under or in connection with this Agreement with venue in Portland Oregon iv Digia II User Manual Intended use FCC compliance EMC directive X Regulatory 8 Restricted rights legend The Licensed Product is provided with RESTRICTED RIGHTS In the event the United States Government or an agency thereof is granted a license the following additional terms apply Restricted Computer Software as defined in the Commercial Computer Software Restricted Rights clause at Federal Acquisition Regulations 52 227 19 and the restrictions as provided in subparagraphs c 1 and c 2 thereof and as applicable the Government s rights to use modify reproduce release perform displ
41. static as a network type you can set the IP address by highlighting the number you want to change click Enter and then use the directional buttons to change the values Click Enter again to set the number then use the left or right directional buttons to move to another position and repeat to change that number Subnet mask The subnet mask of the unit If you choose static as a network type you can set the subnet mask the same way as you set the IP address Gateway The IP address to the gateway router the unit is getting its network connection from If you choose static as a network type you can set the gateway the same was as you set the IP address DNS server The IP address to the DNS server you wish to use If you choose static as a network type you can set the DNS server address the same way as you set the IP address Network e mail Use the Network email submenu Figure 21 to configure your network e mail Figure 21 Network email Digia II Menu Network lt lt Network Email gt gt SMTP Server SMTP Port 0025 Authentication y User Password xxx Sender Email R CRIME RETENUE The menu options include the following SMTP server Enter the SMTP server address for your mail server SMTP port Default is 00025 Authentication Check this box if your mail server requires authentication User name Enter the user name for the SMTP server This is optional Password Enter the password fo
42. ter Scroll down to the System Admin menu NA a Press the right directional button to access the menu 10 Scroll down to Firmware Upgrade 11 Press Enter 12 Use the up and down directional buttons to toggle the value 13 Enter the default Admin Passcode The system begins the upgrade and starts the first of three downloads The system displays Phase 1 3 in the bottom right corner When the upgrade is complete the system reboots 14 You can now configure your unit 14 Digia II User Manual Software installation The DigiaPlayer software lets you view video you recorded from your Digia II You can also convert files for Windows Media Player for users who do not have the Digia Player To complete installation and ensure all items work correctly complete all items in this section Download the required DivX codec To play an AVI export on your PC with Windows Media Player v9 00 or greater you must have the DivX codec which you can download for free at the DivX for Windows page at http www divx com divx windows Click Free download and follow the on screen instructions to install the DivX codec Download DigiaPlayer To install the DigiaPlayer from the Digia II onto your PC use one of the following methods Download the Digia II Download from Digia Browser Download from Digia II To download from the Digia II do the following 1 Insert a compatible USB drive into your computers USB port Press Export fr
43. upgrade processes The approved USB devices include the following Corsair Imation Kingston Lexar PNY Samsung Sandisk Cruzer Titanium series and Sandisk Cruzer Mini series Digia II User Manual Back panel Figure 2 shows the back of the Digia II Figure 2 Digia Il back panel 1 2 3 4 5 6 7 8 9 10 a 12 13 14 15 16 0000000000000000 9 C10 one 14C15C16C AUDIO SS EEE IN eae may PEREA o LAN D als NC C NO ELE ICAC BECO YE HE 3 EE Te OUT The back panel connections include the following 1 to 16 Camera inputs so you can connect the camera to the corresponding BNC connector The unit can identify NTSC or PAL off Camera 1 so ensure to connect a camera to connection one USB USB 2 0 connection to connect compatible USB devices Use to export and upgrade firmware Main monitor Monitor BNC connection Use to connect to a CCTV type monitor SVGA connector VGA connection Use to connect to a computer monitor LAN Ethernet connection Use to connect your Ethernet cable to the Digia II Alarm out NC normally closed C closed and NO normally open connections Use to connect alarm output devices for example a siren Alarm in Alarm terminal strips Use to connect to your alarm triggers the triggers are based on the contact alarm you have set in the Alarms menu NO NC NO trans or NC trans Refer to Alarms on page 30 Audio in out RCA connection Use to connect external speakers and or microphone h
44. zed resellers value added resellers and original equipment manufacturers Customer may be referred to as You or Your whether an individual or a business entity of any kind f Machine means the computer workstation terminal or other hardware product on which the Software is installed 2 License All rights to and in the Licensed Product including but not limited to copyrights patents trademarks and trade secrets belong to GE and GE retains title to each copy of the Software You agree that GE at any time upon reasonable notice may audit Your use of the Software for compliance with the terms and conditions of this Agreement Subject to the terms and conditions of this Agreement GE grants You a nonexclusive license to use the Software but only in the country where acquired provided that You agree to the following You may a install and use the Software on a single Machine at one time unless You have purchased additional copies of the Software in which case You may install the software on the number of Machines for which You have purchased copies of the Software b use the original copy of the Software provided to You for backup purposes You may not a transfer or distribute the Licensed Product to others in electronic format or otherwise and this Agreement shall automatically terminate in the event of such a transfer or distribution b use the Software over a computer network c sell rent lease or sublic
Download Pdf Manuals
Related Search
Related Contents
Weatherables WKG-THDV42-S60 Instructions / Assembly SMC SMCWCB-G2 TP-Link TD-W8951NB User's Manual IFB 48 - RSF Elektronik Fujitsu LIFEBOOK S782 Samsung RF267AEBP User's Manual Glacier Bay FP4A4080SS Installation Guide Appareil de repérage de défauts d`isolation et de contact ISKO 1205 Descargar ficha de catálogo ARCTIC Accelero Xtreme III Copyright © All rights reserved.