Home

IPPU Powered PV MobileGrid 3000-1600

image

Contents

1. F _ 548 12 h 618MM 134MM 50 SMM FIOM fr 30MM x Gem C cc cc cc c coco cococd 2 A8l1 9MIMM C 283MM e x 12MM Q D 8 Page UTICA 15 pages in total Produced by UTICA Singapore 6 Operating Scheme DC POWER OD ee AC POWER L o POWER CHARGE LOAD Q OQ Q Q Q MENU RESET DISPLAY The CPU Display WIND TURBINE SOLAR INPUT AC INPUT AC OUTPUT AC OUTPUT AC OUTPUT DC FUSE Back CPU Diagram Status Description The UTICA MobileGrid CPU is pre configured to be ready for operation therefore is not necessary to make any adjustments in order to be able to get it to operate fully automatic and feed power into the batteries AC indicator light indicates AC INPUT normal flashing that standby Inverter indicator light indicates the MobileGrid s CPU inverter is working Fault indicator lights or flashes to indicate the inverter failure overload output DC input exception CHARGE indicator light indicates normal charging the light does not flash that do not Charge LOAD LED light on the normal output Buzzer System normal no beeps overload fault DC input anomalies there is beep 9 Page UTICA 15 pages in total Produced by UTICA Singapore UTICA MobileGrid 3000 1600 HIM
2. 1 6kWp photovoltaic powered modules 10 UTICA pages in total Produced by UTICA Singapore 7 Controller Settings Service display Your UTICA MobileGrid is equipped with self diagnostic system which automatically identifies a large number of possible defects by itself and displays them on the screen It is thus possible to quickly ascertain defects in the CPU unit and in the PV array as well tt Button is down Startup Battery V Charge A SOLAR REGULATOR Menu Charge A MENU SOLAR REGULATOR d Check system temperature SOLAR REGULATOR MENU Temperature C Check the charging current Check the discharging current Charge Ah MENU Load Ah Check the Battery Capacity Load Ah MENU Battery SOC 11 Page UTICA 15 pages in total Produced by UTICA Singapore Check charge off voltage of battery Battery SOC MENU Charge off V Setup the Charge off voltage of Battery Charge off V Charge off V Check the load off voltage of loads Charge off V MENU Load off V Setup the Load off Voltage of Loads Load off V Load off V Check the load on voltage of loads Setup the load on voltage of loads Adjust Charge off voltage of Battery Load off Voltage of loads and Load on Voltage of loads into the Press down MENU for more than 5 seconds Startup for
3. Without permission repairs only by our certified technicians Any additions or modifications 2 Page UTICA pages in total Produced by UTICA Singapore Incorrect operation or use Not in accordance with the user manual for cleaning or maintenance Abnormal environmental conditions resulting in damage The deliberate destruction damage Natural disasters caused damage 2 Operation Safety In any case the operation cleaning or maintenance must comply with the following provisions if violated the UTICA will not be responsible Not in a volatile gas or combustible environment Do not use positive and negative pole at reverse Never remove the MobileGrid s CPU cover or touch the internal components Do not replacing parts of the equipment 3 Operating Instructions Installation by UTICA professionals or by the appointed integrator Verify that the same load voltage load power is not greater than the rated load Do not allow the liquid into the interior of the machine do not use wet cleaning machine For normal operating environment for the system System operating environment should be well ventilated temperature range 10 degrees to 45 degrees away from the fire not direct sunlight not in the condensation dust environments When the system boots if the input voltage is too low the machine is protected and displayed insufficient voltage Min
4. 3 4 1 92 FIXED OR MOBILE FIXED Inverters 7 5 44 TILT ANGLE 12 AC Current 2 3 5 1 50 80 04 MODULE UTICA 100Wp INVERTER MOBILECRID 3000 SERIES REDUCTION ANNUAL GREENHOUSE GASES EMISSION MAX POWER INPUT Kw 1 60 CO2 2 29 Ton POWER RELATION MAX NOMINAL 1 000 502 6 24 KWP INSTALLED 1 60 4 16 ma sp r rrnYasrra Irradiation over Energy Energy Ener 3 Generated Inclined Surface Generated Generated 3 Month whim2idia whldia oni Coe Epm x 1000 Epm Ep January 5 399 6 914 6 9 214 33 February 5 803 7 431 7 43 208 08 March 5 913 7 572 57 234 74 April 4 934 6 318 6 32 189 55 May 5 142 6 585 6 58 204 13 June 5 154 6 600 6 60 198 01 July 5 399 6 914 6 91 214 33 August 5 876 7 525 7 99 233 28 Setember 5 656 7 243 7 24 217 30 October 5 546 7 102 7 10 220 16 November 4 554 5 832 5 83 174 97 December 4 775 6 115 6 11 189 55 verage 343 5 8 5 85 498 KWH YEAR 186153 ENERGY KWh 250 00 200 00 150 00 4 co 100 00 4 50 00 2322225 Month 0 0 14 Page UTICA ages in total Produced by UTICA Singapore Common Faults and Diagnosis Common faults Approach Shutdown immediately after boot shutdown 1 Confirm the input DC voltage is correct immediately 2 2 sure the load is overloaded after Load Confirm the input DC voltage is within the normal range Eg 1000W input DC voltage range of the system 20VDC 27 5VDC Can not
5. current load Overload protection designed to protect the safe operation of the system when the load is greater than 5 to 20 about 30 seconds the system will automatically shut down when the load is greater than 20 of the system will automatically and immediately shut down DC power supply is less than 15 of the nominal value the system will automatically shut down AC input with this system when the system voltage protection the system will automatically switch to conventional electricity to ensure supply security 4 Page UTICA 15 pages In total Produced by UTICA Singapore 4 Suitable Applications The system can be used in the homes villas construction sites buildings ships areas without electricity the transmitter station and so on Pure sine wave inverter for all loads you can access the inductive load such as fluorescent lights motors refrigerators freezers electric fans transformers microwave ovens air conditioners etc but must be careful not to overload operation This product can not be used without permission of equipment to sustain life the system not suitable for high precision electronic equipment With high risk devices such as microwave ovens air conditioning reboot again 5 minutes later 5 Installation Instructions Connect the battery box Host cells within the battery case wiring has been connected at the factory the positive pole connected with the positive pole
6. over loads Reduce quantity in loads 12 Page UTICA defaults 15 pages in total Produced by UTICA Singapore Startup short circuit Remove malfunction 8 Technical amp Perfo Model Output capacity Output waveform Voltage Accuracy Frequency Accuracy Overload Overvoltage Protection Undervoltage Protection Efficiency Operating Temperature Operating Humidity Operating Altitude Electricity Switching Time Size Weight Battery Case Size H oolar Panels Power Solar Panel Size Battery Controller System PV Inverter Load Reference Name Of Load Est Color TV oatellite TV Receivers LCD Computer Energy saving Lamp Electrograph Printer 7 an Washing Machine Rice Cooker Water Pump V Air condition 13 Page UTICA pages rmance Data UTICA PV MobileGrid 3000 1600 3KVA Pure Sine Wave 220V 3 50HZx3HZ 120 305 gt 58V lt 40V gt 90 5 55 C 0 90 0 3 000m lt 5ms 555X500X200MM 25Kg 555X500X300MM 1600WP 1050 x 670 x 30mm 48V270AH 48V 40A 3000W 48V Power W Quantity Working Time Per Day H Working Days 3 Days in total Produced by UTICA Singapore ENERGY STUDY PROJECT INFORMATION C U U U COUNTRY SINGAPORE Nominal power tolerance values 3 40 CITY SINGAPORE Dust dirt 1 5 2 5 1 00 LATITUDE 1 17 49 Temperature 6 9 6 70 LONGITUDE 103 52 40 E Shadows 0 2 0 00 DC current
7. UTICA Solar Mobile Grid Generator User Manual for 3000 Series Mobile Grid 3000 1600 Sales Support Tel 65 6296 7787 Email buy utica sg 1 Page UTICA 15 pages in total Produced by UTICA Singapore Warning Risk of high voltages Thank you for choosing UTICA and congratulations on your new technically high grade solar powered generator This instruction manual will help you get to know your new machine Please read the manual carefully and you will soon be familiar with all the many great features of your new UTICA product Please also take special note of the safety rules Do not remove the cover on the MobileGrid s CPU machine or phtovoltaic modules Incorrect operation and work performed incorrectly can cause serious injury and damage UTICA MobileGrid design and specification has taken into account the operator s safety strictly in accordance with our manual operation Any improper installation may cause personal injury MobileGrid s CPU with high loads does not allow hot plug or switch repeatedly especially with a compressor type loads such as motors refrigerators air conditioners etc 1 Terms of Use This system in the strict production control and precision testing during the warranty period of two years maintenance service contract up to10 years system warranty under normal use of any natural damage repair is free but if any of the following circumstances the warranty will be void
8. boot Confirm the input DC voltage is connected correctly ZBooting method is correct Can not shut down Shutdown method is correct kipas puten 38 seconds _ D using the system before you read the instructions 2 After wiring check to confirm correct before turning on power 3 long load the machine may have a fever and hot air blown out Updated 28 July 2011 specification is subjected to UTICA changes and terms amp conditions 10 years warranty is based on maintenance schedule service agreement from Utica Energy Pte Ltd Technical Support 65 62967780 15 Page UTICA pages in total Produced by UTICA Singapore
9. ors should not use this product 3 Page UTICA 15 pages In total Produced by UTICA Singapore Verify that the system reliable grounding wire size should meet the safety conditions of use cables as short as possible 80 of the load is better Pay attention to Inductive load started Boot sequence Turn on DC power and then turn on the system and finally open the load shutdown sequence off load shut down the CPU turn off the DC power supply Off Mode Off mode and switch the same way as mobile phone hold down the switch and so heard the beep about 3 seconds then the machine start began to work press power button for 3 seconds the system will be shut down 4 Product Features MobileGrid s CPU control systems intelligent pure sine wave output The system uses frequency inverter transform mode soft switch technology high performance MCU control digital and analog hybrid technology a boost with the completion of the advanced SPWM waveform modulation circuit high efficiency high reliability System output can load all types of single phase equipment such as motors air conditioning electric drill fluorescent lamps television computers fans refrigerators and other appliances communications equipment industrial equipment One Touch Intelligent switch design to facilitate the operation Excellent output short circuit protection design Ability to start to resist high
10. the negative pole connected with the negative pole Then connect to the host as below a 9 _ AG INPUT AG OUTPUT AG OU TPUT ac OU TPUT D FUSE System Wiring Diagram Pase UTICA 15 pages in total Produced by UTICA Singapore The installation of solar panels Tilt angle of solar panels please refer to the local latitude tilt angle is the local latitude The southern hemisphere solar panels toward the north of users users will be solar panels on the northern hemisphere towards the south UTICA MobileGrid 3000 1600 is DC 48V 48V system will be four solar panels connected in series and then each group will be connected in parallel to the system 1 6 Kwp Module Size mm 1050 670 30 Voc 214V Isc 6 564 Vpmax 18V Ipmax 5 764 Ppmax 100W UTICA PV CPU Output 3KW Connect to PV CPU system 48V system photovoltaic panels wiring sample diagram 6 Page UTICA pages in total Produced by UTICA Singapore Panel frame Right B gt Left amp Right C Left A Right A m p gt Left amp Right C S tep 4 Private UTICA rs mu Instruction For Installation 7 Page UTICA 15 pages in total Produced by UTICA Singapore ____ Stander Quantity Illustration __ Thick 3 MM Right 8 mes 3 _ Thick 3 MM Right x S 0 Thick 3 MM Thick 3 E M 48 12