Home

FX3G-CNV-ADP INSTALLATION MANUAL

image

Contents

1. 3 1 Applicable PLC Model name Applicability FX3G Series PLC Ver 1 00 or later from first production For details on the system configuration refer to the following manual Refer to the FX3G Series User s Manual Hardware Edition 3 2 General Specifications The general specifications are equivalent to the PLC main unit E For general specifications refer to the following manuals 3 Connect the connector conversion j h PA adapter to the optional equipment or Refer to the FX3G Series User s Manual Hardware Edition connector D in the figure on the right and fix it using the provided M3 tapping screws E in the figure on the right Safety Precaution Read these precautions before use This manual classifies the safety precautions into two categories DANGER and AACAUTION Indicates that incorrect handling may cause hazardous DANGER conditions resulting in death or severe injury Indicates that incorrect handling may cause hazardous Sr ne ie iti ia i ii ain unit connector CAUTION Sine ie in medium or slight personal injury als pecial adapter connector 4 Connector cover 5 Memory cassette Display module connector Depending on the circumstances procedures indicated by may 6 Special adapter slide lock also cause severe injury MASS Weight 0 1kg 0 22Ibs It is important to follow all precautions for personal safety Connector cover is removed MI
2. 7D3230 1 2 External Dimensions and Part Names fallewint mantial gt LE PRECAUTIONS CAU TION Refer to the FX3G Series User s E a 1 6 3 4 Unit mm inches Manual Hardware Edition i e Please contact a certified electronic waste disposal company for the November 2008 environmentally safe recycling and disposal of your device TRANSPORT AND STORAGE PRECAUTIONS CAUTION e The product is a precision instrument During transportation avoid any impacts Failure to do so may cause failures in the product After transportation verify the operations of the product This manual describes the part names dimensions mounting and specifications of the product Before use read this manual and the manuals of all relevant products fully to acquire proficiency in handling and operating the product Make sure to learn all the product information safety information and precautions Store this manual in a safe place so that it can be taken out and read whenever necessary Always forward it to the end user Registration The company and product names described in this manual are registered trademarks or the trademarks of their respective companies Effective November 2008 Specifications are subject to change without notice 2008 Mitsubishi Electric Corporation 2 Attach the provided side cover C in the figure on the right 90 3 55 For the 40 60 point types it is not necessary to attach the side cover
3. B JY997D32301C_ A B EA JAPANESE B ENGLISH 1 Outline The following section describes the installation method to the FX3G Series PLC 3 Specifications The FX3G CNV ADP special adapter connection conversion adapter hereinafter called FX3G 24MH In this example STARTUP AND MITSUBISHI Changes for the Better connector conversion adapter is a special adapter connection conversion adapter for For more details on installation and removal refer to the following manual 7 MAINTENANCE A CAUTION connecting the analog and communication special adaptors to the main unit of a PLC gt Refer to the FX3G Series User s Manual Hardware Edition PRECAUTIONS 1 1 Incorporated Items MELSEC IF p 1 Turn the power supply OFF Do not disassemble or modify the PLC Product Doing so may cause fire equipment failures or malfunctions FX3G CNV ADP Included For repair contact your local Mitsubishi Electric distributor INSTALLATION MANUAL tems FX3G CNV ADP special adapter connection conversion adapter Remove the top cover A in the figure on the right and peripheral equipment connector cover B in the figure on the right from the front of the main unit M3x8 tapping screws for installation 4 pcs Side cover Installation Manual This manual Do not drop the product or exert strong impact to it Doing so may cause damage A A For 40 60 point types refer to the j Zz mS DISPOSAL Manual Num Y997D32301 2 anual Number JY99
4. TSUBISHI A VOA AHH nma US 74 Tightening torque 0 3 to 0 6 N m jiii Ul UJ a Ul uy Associated Manuals 2 Installation Manual name Description INSTALLATION FX3G Series JY997D31301 Explains the FX3G Series PLC aa Qoen AFD me Conleston converts on adapten r i xplai i A E User s Manual MODEL CODE specifications for I O wiring e Make sure to cut off all phases of the power supply externally before attempting E A E Hardware Edition 09R521 installation and maintenance installation or wiring work Failure to do so may cause electric shock or damage to the product figure on the right This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual How to obtain manuals j i f INSTALLATION Tightening torque 0 3 to 0 6 N m For product manuals or documents consult with the Mitsubishi Electric dealer PRECAUTIONS CAUTION from who you purchased your product oe e Use the product within the generic environment specifications described in PLC ad i main unit manual Hardware Edition E x Never use the product in areas with excessive dust oily smoke conductive oN N VENN ANY Warranty Mitsubishi will not be he
5. ld liable for damage caused by factors found not to be the cause of Mitsubishi opportunity loss or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties NSE N XK WEN NS dusts corrosive gas salt air Cl2 H2S SO2 or NO2 flammable gas vibration or impacts or expose it high temperature condensation or rain and wind If the product is used in such conditions electric shock fire malfunctions deterioration or damage may occur When connecting a cable to the standard built in port RS 422 USB always cut off Use screwdrivers carefully when performing installation work thus avoiding the part A shown in the right figure using snippers etc For details refer to the F f accident or product damage following manual For sate use 2 2 Cable connection When drilling screw holes or wiring make sure cutting or wire debris does not Refer to the FX3G Series User s Manual Hardware Edition enter the ventilation slits Example of connection Failure to do so may cause fire equipment failures or malfunctions Do not touch the conductive parts of the product directly Doing so may cause device failures or malfunctions Connect the adapter securely to their designated connectors Loose connections may cause malfunctions e This product has been ma
6. nufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi Electric e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system a MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN HIMEJI WORKS 840 CHIYODA CHO HIMEJI JAPAN

Download Pdf Manuals

image

Related Search

Related Contents

manual de instalacion y uso calefactor electrico  Manual Instalação Inverter  3Com V7000 Owner's Manual  HP 574412-DOC User's Manual  BEDIENUNGSANLEITUNG  lavavajillas colectividades - Hiperlimpieza® Venta de productos de  Allied Telesis AT-GS950/8POE network switch  PT Manual de Instruções PPF 650  

Copyright © All rights reserved.
Failed to retrieve file